• Title/Summary/Keyword: Metal ceramic

Search Result 1,483, Processing Time 0.034 seconds

THE EFFECT OF SURFACE FINISHES ON FLEXURAL STRENGTH, FRACTURE TOUGHNESS OF FELDSPATHIC DENTAL PORCELAIN

  • Chang, Il-Sung;Lee, Sun-Hyung;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.293-305
    • /
    • 2005
  • Statement of problems. Conventional feldspathic porcelain is used extensively as a restorative material and it is subjected to grinding and polishing during fabrication and delivery procedures. There is still considerable controversy concerning the best methods to achieve the strongest porcelain restorations after such adjustments. Purpose. The objective of this study was to investigate the effects of (1) overglazing, (2) selfglazing, and (3) fine polishing on the flexural strength and fracture toughness of feldspathic dental porcelain. Material and method. Ninety porcelain disks were prepared for flexural strength test and sixty porcelain disks were fabricated for fracture toughness test. Specimens were divided into three groups for each test as follows: 1) overglazed 2) self-glazed 3) polished. The flexural strength of feldspathic porcelains was determined by ring-on-ring biaxial flexural strength test. The fracture toughness values of three experimental groups were obtained by indentation fracture toughness test. Results. The flexural strength of overglazed group was significantly higher than that of selfglazed and polished group (P<0.05), while the difference between self-glazed and polished group was not significant (P>0.05). The fracture toughness values of overglazed and polished group were significantly higher than that of self-glazed group (P<0.05), while the difference between overglazed and polished group was not significant (P>0.05). Conclusions. This results supported the use of polishing as an alternative to glazing metal ceramic restorations, as it was not detrimental in flexural strength and fracture toughness. But, under the conditions of this study, overglazing was the ideal surface finishing method of feldspathic dental porcelain.

Time series analysis of patients seeking orthodontic treatment at Seoul National University Dental Hospital over the past decade

  • Lim, Hyun-Woo;Park, Ji-Hoon;Park, Hyun-Hee;Lee, Shin-Jae
    • The korean journal of orthodontics
    • /
    • v.47 no.5
    • /
    • pp.298-305
    • /
    • 2017
  • Objective: This paper describes changes in the characteristics of patients seeking orthodontic treatment over the past decade and the treatment they received, to identify any seasonal variations or trends. Methods: This single-center retrospective cohort study included all patients who presented to Seoul National University Dental Hospital for orthodontic diagnosis and treatment between January 1, 2005 and December 31, 2015. The study analyzed a set of heterogeneous variables grouped into the following categories: demographic (age, gender, and address), clinical (Angle Classification, anomaly, mode of orthodontic treatment, removable appliances for Phase 1 treatment, fixed appliances for Phase 2 treatment, orthognathic surgery, extraction, mini-plate, mini-implant, and patient transfer) and time-related variables (date of first visit and orthodontic treatment time). Time series analysis was applied to each variable. Results: The sample included 14,510 patients with a median age of 19.5 years. The number of patients and their ages demonstrated a clear seasonal variation, which peaked in the summer and winter. Increasing trends were observed for the proportion of male patients, use of non-extraction treatment modality, use of ceramic brackets, patients from provinces outside the Seoul region at large, patients transferred from private practitioners, and patients who underwent orthognathic surgery performed by university surgeons. Decreasing trends included the use of metal brackets and orthodontic treatment time. Conclusions: Time series analysis revealed a seasonal variation in some characteristics, and several variables showed changing trends over the past decade.

Effects of crown retrieval on implants and the surrounding bone: a finite element analysis

  • Ozkir, Serhat Emre;Unal, Server Mutluay;Yurekli, Emel;Guven, Sedat
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.131-136
    • /
    • 2016
  • PURPOSE. The aim of this study was to observe stress concentration in the implant, the surrounding bone, and other components under the pull-out force during the crown removal. MATERIALS AND METHODS. Two 3-dimensional models of implant-supported conventional metal ceramic crowns were digitally constructed. One model was designed as a vertically placed implant ($3.7mm{\times}10mm$) with a straight abutment, and the other model was designed as a 30-degree inclined implant ($3.7mm{\times}10mm$) with an angled abutment. A pull-out force of 40 N was applied to the crown. The stress values were calculated within the dental implant, the abutment, the abutment screw, and the surrounding bone. RESULTS. The highest stress concentration was observed at the coronal portion of the straight implant (9.29 MPa). The stress concentrations at the cortical bone were lower than at the implants, and maximum stress concentration in bone structure was 1.73 MPa. At the abutment screws, the stress concentration levels were similiar (3.09 MPa and 3.44 MPa), but the localizations were different. The stress at the angled abutment was higher than the stress at the straight abutment. CONCLUSION. The pull-out force, applied during a crown removal, did not show an evident effect in bone structure. The higher stress concentrations were mostly observed at the implant and the abutment collar. In addition, the abutment screw, which is the weakest part of an implant system, also showed stress concentrations. Implant angulation affected the stress concentration levels and localizations. CLINICAL IMPLICATIONS. These results will help clinicians understand the mechanical behavior of cement-retained implant-supported crowns during crown retrieval.

Synthesis of Poly(alkylene carbonate) from Carbon Dioxide (이산화탄소로부터 Poly(alkylene carbonate)의 합성)

  • Lee, Yoon-Bae;Choi, Jeong-Hyun
    • Applied Chemistry for Engineering
    • /
    • v.7 no.5
    • /
    • pp.813-822
    • /
    • 1996
  • In order to reduce carbon dioxide, one of the major greenhouse gases, a new type of copolymer, poly(alkylene carbonate) has been synthesized. The alternating copolymers have been obtained from carbon dioxide and various epoxides with zinc carboxylate as a catalyst. The number-average molecular weight of the polymer is about 50,000 and polydispersity is rather broad(5~10). The polymers are amorphous, and glass-clear materials that exhibit unusually facile and clean thermal decomposition behavior. Complete decomposition with no carbon residue is observed at elevated temperature even in an inert atmosphere. Terpolymers with bulkier epoxides improve the physical properties of the copolymer with simple epoxides. The decomposition properties of the polymer provide versatile applications such as ceramic, metal, and electronic binders and lost-foam casting. Further application of the polymer for the barrier film or the plasticizer will be investigated.

  • PDF

Fabrication and Stability of Pd Coated Ta/YSZ Cermet Membrane for Hydrogen Separation (Pd 코팅된 Ta/YSZ 수소분리막의 제조 및 안정성)

  • Lee, Sang-Jin;Jeon, Sung-Il;Park, Jung-Hoon
    • Membrane Journal
    • /
    • v.20 no.1
    • /
    • pp.69-75
    • /
    • 2010
  • Cermet membrane was fabricated with tantalum as hydrogen-permeable metal and $Y_2O_3$-stabilized $ZrO_2$ (YSZ) as ceramic supporter. Ta/YSZ cermet membrane was prepared through pre-sintering in He atmosphere and then main sintering under high vacuum and the impurities to originate from sintering and brazing could be removed by mechanical polishing. As-prepared membrane showed dense structure with continuous channel of tantalum. Hydrogen permeation experiment was conducted in the region of $200{\sim}350^{\circ}C$ using Ta/YSZ membrane coated with Pd for hydrogen dissociation. The crack in membrane was formed at $300^{\circ}C$ and the Pd coating layer has flaked off in spots. XRD results showed that tantalum reacted with hydrogen to form $Ta_2H$. The lattice expansion by $Ta_2H$ caused deterioration for membrane.

Experimental Investigations into the Precision Cutting of High-pressured Jet for Thin Multi-layered Material (다층박판재료의 초고압 젯 정밀가공에 대한 실험적 연구)

  • Park, Kang-Su;Bahk, Yeon-Kyeung;Lee, Jung-Han;Lee, Chae-Moon;Go, Jeung-Sang;Shin, Bo-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.7
    • /
    • pp.44-50
    • /
    • 2009
  • High-pressured jetting is now widely used in the advanced cutting processes of polymers, metals, glass, ceramics and composite materials because of some advantages such as heatless and non-contacting cutting. Similarly to the focused laser beam machining, it is well known as a type of high-density energy processes. High-pressured jetting is going to be developed not only to minimize the cutting line width but also to achieve the short cutting time as soon as possible. However, the interaction behavior between a work piece and high-velocity abrasive particles during the high-pressured jet cutting makes the impact mechanism even more complicated. Conventional high-pressured jetting is still difficult to apply to precision cutting of micro-scaled thin work piece such as thin metal sheets, thin ceramic substrates, thin glass plates and TMM (Thin multi-layered materials). In this paper, we proposed the advanced high-pressured jetting technology by introducing a new abrasives supplying method and investigated the optimal process conditions of the cutting pressure, the cutting velocity and SOD (Standoff distance).

A Deterministic Safety Assessment of a Pyro-processed Waste Repository (A-KRS 처분 시스템 결정론적 안전성 평가)

  • Lee, Youn-Myoung;Jeong, Jongtae;Choi, Jongwon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.3
    • /
    • pp.171-188
    • /
    • 2012
  • A GoldSim template program for a safety assessment of a hybrid-typed repository system, called "A-KRS," in which two kinds of pyro-processed radioactive wastes, low-level metal wastes and ceramic high-level wastes that arise from the pyro-processing of PWR nuclear spent fuels are disposed of, has been developed. This program is ready both for a deterministic and probabilistic total system performance assessment which is able to evaluate nuclide release from the repository and farther transport into the geosphere and biosphere under various normal, disruptive natural and manmade events, and scenarios. The A-KRS has been deterministically assessed with 5 various normal and abnormal scenarios associated with nuclide release and transport in and around the repository. Dose exposure rates to the farming exposure group have been evaluated in accordance with all the scenarios and then compared among other.

Evaluation of Mechanical Properties and Microstructural Behavior of Sintered WC-7.5wt%Co and WC-12wt%Co Cemented Carbides

  • Raihanuzzaman, Rumman Md.;Song, Jun-U;Tak, Byeong-Jin;Hong, Hyeon-Seon;Hong, Sun-Jik
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.58.1-58.1
    • /
    • 2011
  • WC-Co and other similar cemented carbides have been widely used as hard materials in industrial cutting tools and as mould metals; and a number of techniques have been applied to improve its microstructural characteristics, hardness and ear resistance. Cobalt is used primarily to facilitate liquid phase sintering and acts as a matrix, i.e. a cementing phase between WC grains. A uniform distribution of metal phase in a ceramic is beneficial for improved mechanical properties of the composite. WC-Co, starting from initial powders, is vastly used for a variety of machining, cutting, drilling, and other applications because of its unique combination of high strength, high hardness, high toughness, and moderate modulus of elasticity, especially with fine grained WC and finely distributed cobalt. In this study, that started with two different compositions of initial powders, WC-7.5wt%Co and WC-12wt%Co with initial powder size being 1~3 ${\mu}m$, magnetic pulsed compaction followed by subsequent vacuum sintering were carried out to produce consolidated preforms. Magnetic Pulsed Compaction (MPC), a very short duration (~600 ${\mu}s$), high pressure (~4 Gpa), high-density preform molding method was used with varied pressure between 0.5 and 3.0 Gpa, in order to reach an initial high density that would help improve the sintering behavior. For both compositions and varied MPC pressure, before and after sintering, changes in microstructural behavior and mechanical properties were analyzed. With proper combination of MPC pressure and sintering, samples were obtained with better mechanical properties, densification and microstructural behavior, and considerably improved than other conventional processes.

  • PDF

Research for the Standard Model of the Items of the National Qualification Examination for the Dental Technician (치과기공사국가시험 문항개발기준안연구)

  • Lee, Duck-Hye;Chung, In-Sung;Han, Chang-Sik
    • Journal of Technologic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.75-93
    • /
    • 2002
  • This research was preformed for the purpose of preparing the items of standard model of the national dental technician test base on the duty analysis of the dental technician. The results of the duty analysis for the dental technician follows. 1. The dental technician is a profession to make the oral function smooth through the dental supplement and equipment in a scientific method and the skilled technique. 2. The duty of the dental technician are determined as A. preparation for manufacture B. manufacture C. management of the place of the dental technology D. self-development. A. The field of "the preparation for manufacture" are determined as 1. to confirm work authorization 2. To confirm the working model, B. The field of "In manufacture" are determined as 1. to manufacture the temporary crown 2. to manufacture the inlay and crown & bridge prosthesis 3. to manufacture the porcelain fused metal crown prosthesis 4. to manufacture the all ceramic crown prosthesis 5. to manufacture the temporary denture prosthesis 6. to manufacture the partial denture prosthesis 7. to manufacture the complete denture prosthesis 8. to manufacture the attachment prosthesis 9. to manufacture implant prosthesis 10. to manufacture the removable orthodontic device, 11. to manufacture the fixed orthodontic device, 12. to manufacture the orthodontic study cast C. The field of "in management of the dental lab." are determined as 1. management 2. to control the dental lab. D. The field of "In the self-development" are determined as 1. to improve the professionalism 2. self-control. 3. The developing items selected under the duty evaluation of the dental technician are l7s in the manufacture preparation, 1,011s in the manufacture, 7s in the management for the dental technology, 5s in self-development, and in all together 1,040s

  • PDF

Effects of Microstructure on Thermoelectric Properties of $FeSi_2$

  • Park, Joon-Young;Song, Tae-Ho;Lee, Hong-Lim;Pai, Chul-Hoon
    • The Korean Journal of Ceramics
    • /
    • v.2 no.1
    • /
    • pp.11-18
    • /
    • 1996
  • The variation of electrical conductively and Seebeck coefficient of FeSi2 according to the density of the specimen has been observed over the temperature range 50 to $700^{\circ}C$. A conventional pressureless sintering method with various sintering time (0, 0.5, 1, 5h) at $1190^{\circ}C$ and/or various sintering temperatures(1160, 1175, 1190, $1200^{\circ}C$) for 2 h was carried out to prepare $FeSi_2$ specimens having various densities. The relationship between the electrical conductivity and Seebeck coefficient was investigated after two steps of annealing (at $865^{\circ}C$ and then $800^{\circ}C$ for total 160h) and thermoelectric measurement. The electrical conductivity for the specimens showed a typical tendency of semiconductor, the average activation energy of which in the intrinsic region (above $300^{\circ}C$) was observed approximately as 0.452 eV, and increased slightly with density. On the other hand, the specimen of the lower density showed the higher value of Seebeck coefficient in the intrinsic region. As the temperature fell into the non-degenerate region, the highly densified specimen which had relatively little residual metal phase showed the higher value of Seeback coefficient. The power factor of all specimens showed the optimum value at $200^{\circ}C$. However, the power factor of the specimen of the lower density increased again from $400^{\circ}C$ and that of the higher dense specimen increased from $500^{\circ}C$. The power factor was more affected by Seebeck coefficient than electrical conductivity over all temperature range.

  • PDF