• 제목/요약/키워드: Metal carbide

검색결과 268건 처리시간 0.026초

레진강화형 글라스아이오노머의 2 축 굽힘강도 (BI-AXIAL FRACTURE STRENGTH OF RESIN MODIFIED GLASS IONOMERS)

  • 이용근;임미경;구대회;이정식
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.751-760
    • /
    • 1997
  • Resin-modified glass ionomers were introduced in 1988 to overcome the problems of moisture sensitivity and low early mechanical strengths of the conventional glass ionomers, and to maintain their dinical advantages. The purpose of this study was to evaluate the bi-axial fracture strength of four resinmodified glass-ionomers(Fuji II LC, Vitremer, Dyract, VariGlass), one resin composite material(Z-100), and one conventional glass-ionomer(Fuji II). Three specimens of each material and shade combination were made according to the manufacturers' instructions. Materials were condensed into metal mold with a diameter of 10mm and a thickness of 2.0mm and pressed between two glass plates. Resin-modified glass ionomers were polymerized using a Visilux II light curing unit by irradiating for 60 seconds from both sides, and conventional glass ionomer was cured chemically. After specimens were removed from the molds, surfaces were polished sequentially on wet sandpapers up to No. 600 silicone carbide paper. The specimens were thermocycled for 2,000 cycles between $5^{\circ}C$ and $55^{\circ}C$ distilled water. After thermocycling, bi-axial fracture strengths were measured using a compressive-tensile tester(Zwick 1456 Z020, Germany) with the cross head speed of 0.5mm/minute. The results were as follows: 1. Two factors of the kind and color of materials had a main effect on bi-axial fracture strength (p<0.01), and bi-axial fracture strength was influenced significantly by the kinds of materials (p<0.01). But there was no significant interaction between two variables of the kind and color of materials (p>0.05). 2. Comparing the mechanical properties of the materials, the elastic modulus of Z100 was higher than any other material, and there was no difference in the displacement at fracture among materials. The bi-axial fracture strength of Z100 was significantly higher than any other material, and that of resin-modified glass ionomers was significantly higher than that of conventional glass ionomer (p<0.05). 3. In the same material group, the color of material had little influence on the mechanical properties.

  • PDF

2급(級) 와동(窩洞) 수복시(修復時) 치아파괴(齒牙破壞) 저항성(抵抗性) 및 귀열양상(龜裂樣相)에 관(關)한 연구(硏究) (A STUDY ON THE FRACTURE RESISTANCE AND CHARACTERISTICS OF TEETH IN CLASS II CAVITY RESTORATIONS)

  • 주익남;박상진;민병순;최호영
    • Restorative Dentistry and Endodontics
    • /
    • 제13권2호
    • /
    • pp.337-348
    • /
    • 1988
  • The purpose of this study was to examine the fracture strength and characteristics of teeth with MOD cavity preparation. Freshly extracted sound maxillary premolars were cleaned and stored in normal saline solution $37^{\circ}C$ for 72 hours before experiments. The roots of teeth were embedded in a self-curing resin, and the exposed crown were maintained in a vertical position by a modelling wax in a brass ring. The MOD cavities were prepared with No. 57 carbide bur under high speed to a depth of 2.0mm and a width of 2.0mm(Fig.1). All the prepared teeth specimens were divided into 7 groups according to the mode of cavity form and restorative materials (Table 1, 2): Group I, unpreapred, intact teeth as control Group II, prepared cavity without restoration Group III, prepared teeth restored with amalgam Group IV, prepared teeth restored with composite resin (P-10) Group V, prepared teeth with beveled enamel margins restored with composite resin (P-10) Group VI, prepared teeth restored with light-cured composite resin (P-30) Group VII, prepard teeth with beveled enamel margins restored with light-cured composite resin (P-30) After placement of restorations, all of the specimens were stored in water at $37^{\circ}C$ for 72 hours before testing. All of the specimens were tested on the Instron Universal Testing machine (No. 6025) in order to evaluate the strength of fracture. One metal ball 5.0mm in diameter contacting the specimens parallel to the occlusal surface was used to in this study (Fig. 1). The fracture characteristics of the specimens were examined with naked eye and in the scanning electron microscope (JSM-20). The results obtained from this study were as follows: 1. The mean fracture strength was the highest in group VI and that in group II was the lowest. 2. The progress of crack of teeth propagated into the pulp cavity. 3. In case of the group of the restored teeth, the crack occurred to be accompanied with cuspal fracture. 4. The crack of restored teeth was initiated along the pulpo-axial line angle of the cavity.

  • PDF

APT(S) 제조 시 전기투석법을 이용한 H2WO4(Aq)내의 Na 제거 방법에 관한 연구 (A Study on Na Removal Method in H2WO4(Aq) by Electrodialysis in APT(S) Manufacturing)

  • 강용호;현승균
    • 자원리싸이클링
    • /
    • 제26권6호
    • /
    • pp.65-72
    • /
    • 2017
  • APT (Ammonium paratungstate)는 금속절단 공구, 드릴의 날, 광산공구, 군사무기 재료 등 산업 전반에 다양한 용도로 사용되며, 고순도의 APT(S)를 제조하기 위해서는 $Na_2WO_4$ 수용액으로부터 전환된 $H_2WO_4$ 내의 불순물 정제 공정이 필요하다. 이미 널리 알려진 기존의 습식방법인 $Na_2WO_4$ 수용액에 HCl(Aq)을 첨가하여 $H_2WO_4(S)$을 제조하는 경우에는 불순물인 Na를 200 ppm 이하로 제거하는데 어려움이 있다. 이러한 점을 개선하기 위하여 본 연구에서는 양이온 격막을 이용한 전기투석 공정을 통해 Na를 제거하는 보다 경제적이고 효율적인 방법을 연구하였다. 폐 텅스텐 초경드릴 및 스크랩을 용해하기 위해 첨가되었던 $Na_2CO_3(S)$로 인한 $H_2WO_4$ 수용액 내의 다량의 Na를 전기투석 공정을 통해 20 ppm 이내로 제거함으로써 전기투석법 이용 시 Na 제거 효과가 큼을 확인하였다.

INNOVATIVE CONCEPT FOR AN ULTRA-SMALL NUCLEAR THERMAL ROCKET UTILIZING A NEW MODERATED REACTOR

  • NAM, SEUNG HYUN;VENNERI, PAOLO;KIM, YONGHEE;LEE, JEONG IK;CHANG, SOON HEUNG;JEONG, YONG HOON
    • Nuclear Engineering and Technology
    • /
    • 제47권6호
    • /
    • pp.678-699
    • /
    • 2015
  • Although the harsh space environment imposes many severe challenges to space pioneers, space exploration is a realistic and profitable goal for long-term humanity survival. One of the viable and promising options to overcome the harsh environment of space is nuclear propulsion. Particularly, the Nuclear Thermal Rocket (NTR) is a leading candidate for nearterm human missions to Mars and beyond due to its relatively high thrust and efficiency. Traditional NTR designs use typically high power reactors with fast or epithermal neutron spectrums to simplify core design and to maximize thrust. In parallel there are a series of new NTR designs with lower thrust and higher efficiency, designed to enhance mission versatility and safety through the use of redundant engines (when used in a clustered engine arrangement) for future commercialization. This paper proposes a new NTR design of the second design philosophy, Korea Advanced NUclear Thermal Engine Rocket (KANUTER), for future space applications. The KANUTER consists of an Extremely High Temperature Gas cooled Reactor (EHTGR) utilizing hydrogen propellant, a propulsion system, and an optional electricity generation system to provide propulsion as well as electricity generation. The innovatively small engine has the characteristics of high efficiency, being compact and lightweight, and bimodal capability. The notable characteristics result from the moderated EHTGR design, uniquely utilizing the integrated fuel element with an ultra heat-resistant carbide fuel, an efficient metal hydride moderator, protectively cooling channels and an individual pressure tube in an all-in-one package. The EHTGR can be bimodally operated in a propulsion mode of $100MW_{th}$ and an electricity generation mode of $100MW_{th}$, equipped with a dynamic energy conversion system. To investigate the design features of the new reactor and to estimate referential engine performance, a preliminary design study in terms of neutronics and thermohydraulics was carried out. The result indicates that the innovative design has great potential for high propellant efficiency and thrust-to-weight of engine ratio, compared with the existing NTR designs. However, the build-up of fission products in fuel has a significant impact on the bimodal operation of the moderated reactor such as xenon-induced dead time. This issue can be overcome by building in excess reactivity and control margin for the reactor design.

NaOH 처리한 Fe 첨가된 Ti alloys의 아파타이트 형성관찰 (A study of apatite formation on NaOH treated Ti alloys with different Iron content)

  • 이승우;김윤종;류재경;김택남
    • 공학논문집
    • /
    • 제6권2호
    • /
    • pp.23-32
    • /
    • 2004
  • 현재까지 사용되어가지고 있는 임플란트 재료 중 commercially pure titanium (순수티탄; Cp-Ti)과 Ti-alloy들은 생체재료로 폭넓게 사용되어지고 있는데, Ti 금속들은 경도가 강하고 점도가 높기 때문에, 치과나 정형외과 등의 하중에 잘 견디는 곳에 이용되어지고 있다고 한다. 이것들은 생체적합성과 부식에 대한 저항성도 좋은 것으로 알려져 있다. 일반적으로 Ti은 4종류의 Grade로 강도의 차이에 의하여 분류되고 Ti의 강도에 영향을 미치는 것으로는 산소, 철, 질소등이 있다. 따라서 본 연구에서는 O와 Fe의 함량을 달리한 Ti alloy시편을 사용하여 생체적합성 실험을 하였다. 먼저 실험은 시편을 micropolishing하고 5M NaOH에서 $60^{\circ}C$에서24시간 처리하여서 비표면적을 넓혔으며, 표면의 $TiO_2$을 만들어주기 위하여 $600^{\circ}C$에서 열처리하였다. 그런 시편을 $36.5^{\circ}C$의 SBF에 넣어 1~14일까지 침적한 후에 표면에 형성된 apatite를 SEM과 EDAX로 조사하였다. 조사 결과 모든 시편에서 apatite가 생성되었지만, 시편의 조성에 따라서 apatite의 형성양이 다름을 확인하였다.

  • PDF

최적 고속화염용사코팅 공정기술에 의하여 제조된 WC-CoCr 코팅의 마모 특성 (Wear Property of HVOF WC-CoCr Coating Manufactured by Optimal Coating Process)

  • 송기오;조동율;윤재홍;방위;윤석조;윤국태;서창희;황순영;하성식
    • 대한금속재료학회지
    • /
    • 제46권6호
    • /
    • pp.351-356
    • /
    • 2008
  • Thermally sprayed tungsten carbide-based powder coatings are being widely used for a variety of wear resistance applications. The coating deposited by high velocity processes such as high velocity oxy-fuel (HVOF) thermal spraying is known to provide improved wear resistant property. In this study, optimal coating process (OCP) is obtained by the study of coating properties such as surface hardness, porosity, surface roughness and microstructure of 9 coatings prepared by Taguchi program for 3 levels of four spray parameters. The Friction and wear behaviors of HVOF WC-CoCr coating prepared by OCP, electrolytic hard chrome (EHC) plating and Inconel718 (In718) are investigated by reciprocating sliding wear test at $25^{\circ}C$, $450^{\circ}C$. Friction coefficients (FC) of all of the 3 samples are decreased as increasing sliding surface temperature from $25^{\circ}C$ to $450^{\circ}C$. FC of WC-CoCr decreases as increasing the surface temperature from $0.33{\pm}0.02$ at $25^{\circ}C$ to $0.26{\pm}0.02$ at $450^{\circ}C$, showing the lowest FC among the 3 samples. Wear trace (WT) and wear depth (WD) of WC-CoCr are smaller than those of EHC and In718 both at $25^{\circ}C$ and $450^{\circ}C$. These show that WC-CoCr is highly recommendable for protective coating on In718 and other metal components.

cBN 입자상 강화재 첨가에 따른 중성자 흡수용 B4C/Al 복합재의 열전도도 변화 연구 (Improving Thermal Conductivity of Neutron Absorbing B4C/Al Composites by Introducing cBN Reinforcement)

  • 강민우;이동현;이태규;김정환;이상복;권한상;조승찬
    • Composites Research
    • /
    • 제36권6호
    • /
    • pp.435-440
    • /
    • 2023
  • 본 연구에서는 기존 사용후핵연료(Spent nuclear fuel) 운반/저장 용기에 사용되는 중성자 흡수용 B4C/Al 복합소재의 열전도도를 개선하기 위해 탄화붕소(B4C)와 입방정 질화붕소(cBN)를 동시에 강화재로 사용한 알루미늄(Al) 기지 복합소재를 제조하고 평가를 진행하였다. 이를 위해서 교반주조 공정을 통해 복합재 잉곳을 제조하고 이를 압연하여 중성자 흡수용 소재를 성공적으로 제조하였다. 제조된 소재의 평가를 위해 cBN 첨가에 따른 열전도도와 중성자 흡수능 변화를 관찰하였다. 열전도도 측정 결과, B4C 단일 입자만을 사용한 복합소재 대비 B4C, cBN을 함께 사용한 복합소재가 동일 체적률 조건 하에서 약 3%의 열전도도 증가가 발생하는 것을 확인하였으며 중성자 흡수 단면적 계산을 통해 중성자 흡수능이 무시할 수 있는 수준으로 저하가 발생하는 것을 확인하였다. 본 연구의 결과를 바탕으로, 중성자 흡수 소재의 새로운 설계 방안을 제시하고 고성능 운반/저장 용기의 개발에 기여할 수 있을 것으로 기대된다.

코팅된 지대주 나사의 반복 착탈 후 풀림력과 표면변화에 대한 연구 (Detorque force and surface change of coated abutment screw after repeated closing and opening)

  • 장종석;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.500-510
    • /
    • 2008
  • 연구목적: 최근 지대주 나사에 WC/C 또는 TiN 코팅이 연구되고 있으며, 이들을 금속표면에 코팅 시 마찰계수의 감소와 부식에 대한 저항, 물리적 취약함의 해소 등의 효과를 얻을 수 있으며. 코팅된 지대주 나사에서 마모와 적합도, 풀림력이 향상되었다는 결과들이 보고되고 있다. 본 연구에서는 지대주 나사에 적용된 코팅이 나사 풀림에 미치는 영향을 알아보아 임상적으로 문제가 되고 있는 지대주 나사의 풀림현상을 해소하는데 그 목적이 있다. 연구재료 및 방법: 코팅되지 않은 타이타늄 지대주 나사와 (그룹 A) WC/C (그룹 B)와 TiN (그룹 C)으로 코팅된 지대주 나사의 10회 반복 착탈시 풀림력 및 표면의 변화를 비교해본 결과 다음과 같은 결론을 얻었다. 결과: 1. 반복 착탈 전, 그룹 A는 일정한 방향성을 가진 다소 거친 표면이 관찰되었으 나 그룹 B와 그룹 C는 코팅된 입자들이 관찰되었으며 코팅층이 전체적으로 균일하고 매끈한 모양을 나타내었다. 2. 반복 착탈 전, 그룹 B에 비해 그룹 C의 표면에서 코팅 입자의 크기가 더 크고 두껍게 코팅 된 모양을 나타내었다. 3. 반복 착탈 후, 그룹 A와 그룹 B에서는 지대주 나사 표면의 마모와 변형이 관찰 되었으며 그룹 B에서는 코팅 입자의 탈락 현상을 볼 수 있었다. 4. 반복 착탈 전과 후의 지대주 나사 무게의 변화를 측정한 결과 그룹 A가 가장 큰 감소를 보였으며, 그룹 C가 그룹 B 보다 무게의 변화가 적었으나 두 그룹간 통계적으로 유의한 차이는 없었다. 5. 그룹 B와 그룹 C는 그룹 A에 비해 높은 평균 풀림력을 나타내었고 통계학적으로 유의할 만한 차이가 있었다. 6. 그룹 A에서 그룹B 와 그룹 C보다 평균 풀림력의 감소 경향이 더욱 현저 하게 나타났다. 결론: 결론적으로, WC/C 또는 TiN 코팅된 지대주 나사는 반복적인 사용 후에도 코팅되지 않은 타이타늄 지대주 나사에 비해 뚜렷한 표면 변화를 보이지 않았으며 마모에 대한 저항성이 우수하였고 높은 풀림력을 나타내었다. 따라서 지대주 나사에 WC/C 또는 TiN 코팅을 적용 시 나사 풀림의 문제점을 개선할 수 있을 것으로 사료된다.