• 제목/요약/키워드: Metal Surface

검색결과 5,299건 처리시간 0.035초

Short Channel SB-FETs의 Schottky 장벽 Overlapping (Schottky barrier overlapping in short channel SB-MOSFETs)

  • 최창용;조원주;정홍배;구상모
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.133-133
    • /
    • 2008
  • Recently, as the down-scailing of field-effect transistor devices continues, Schottky-barrier field-effect transistors (SB-FETs) have attracted much attention as an alternative to conventional MOSFETs. SB-FETs have advantages over conventional devices, such as low parasitic source/drain resistance due to their metallic characteristics, low temperature processing for source/drain formation and physical scalability to the sub-10nm regime. The good scalability of SB-FETs is due to their metallic characteristics of source/drain, which leads to the low resistance and the atomically abrupt junctions at metal (silicide)-silicon interface. Nevertheless, some reports show that SB-FETs suffer from short channel effect (SCE) that would cause severe problems in the sub 20nm regime.[Ouyang et al. IEEE Trans. Electron Devices 53, 8, 1732 (2007)] Because source/drain barriers induce a depletion region, it is possible that the barriers are overlapped in short channel SB-FETs. In order to analyze the SCE of SB-FETs, we carried out systematic studies on the Schottky barrier overlapping in short channel SB-FETs using a SILVACO ATLAS numerical simulator. We have investigated the variation of surface channel band profiles depending on the doping, barrier height and the effective channel length using 2D simulation. Because the source/drain depletion regions start to be overlapped each other in the condition of the $L_{ch}$~80nm with $N_D{\sim}1\times10^{18}cm^{-3}$ and $\phi_{Bn}$ $\approx$ 0.6eV, the band profile varies as the decrease of effective channel length $L_{ch}$. With the $L_{ch}$~80nm as a starting point, the built-in potential of source/drain schottky contacts gradually decreases as the decrease of $L_{ch}$, then the conduction and valence band edges are consequently flattened at $L_{ch}$~5nm. These results may allow us to understand the performance related interdependent parameters in nanoscale SB-FETs such as channel length, the barrier height and channel doping.

  • PDF

생활폐기물(生活廢棄物) 소각(燒却) 바닥재의 자력선별(磁力選別)에 따른 크롬과 니켈의 거동(擧動) (Effect of magnetic separation in removal of Cr and Ni from municipal solid waste incineration (MSWI) bottom ash)

  • 안지환;엄남일;조계홍;오명환;유광석;한기천;조희찬;한춘;김병곤
    • 자원리싸이클링
    • /
    • 제16권6호
    • /
    • pp.3-9
    • /
    • 2007
  • 생활 폐기물은 대부분 유리류와 자기류뿐만 아니라 많은 양의 iron을 함유하고 있으며 약 $3{\sim}11%$에 달한다. 대부분의 iron은 Ni-Fe와 Ni-Cr-Fe 같은 합금으로 존재하거나, 부식방지와 광택을 위해 Ni와 Cr로 도금된 iron으로 존재하고 있기 때문에 소각로에서 소각될 경우 철 재품 표면에 심하게 파손된 $Fe_3O_4$층과 함께 $NiFe_2O_4$FeCr_2O_4$을 형성하게 되어 바닥재에 존재하게 되어 중금속산화물 층을 형성시킬 수 있다. iron은 자력이 매우 강해 자력선별에 의해 쉽게 선별되며 이러한 효과로 인해 중금속 산화물의 선별까지 얻을 수 있다. 또한 바닥재는 다양한 Ni와 Cr 산화물들을 함유하고 있으며, Ni와 Cr은 강자성을 띈 물질이기 때문에 자력선별에 의해 큰 영향을 받을 수 있다. 따라서 자력선별에 따른 Ni와 Cr의 거동에 대해 조사하였으며 그 밖의 다른 중금속(Cu, Pb, Cd, As)들의 거동 또한 확인해 보았다. 그 결과 Ni와 Cr은 약 $45{\sim}50%$의 선별율을 보였으며, Cu와 Pb는 $15{\sim}20%$을 나타냈다. 또한 자력선별 전과 후의 바닥재에 대해 Ni와 Cr의 용출량을 확인해본 결과 자력선별 후 바닥재의 용출량이 더 낮음을 확인할 수 있었다.

Principal Component Analysis와 Multi-Dimensional Scaling 분석을 이용한 시화공단 시흥천의 수질지표 및 미생물 군집 분포 연구 (Assessing Water Quality of Siheung Stream in Shihwa Industrial Complex Using Both Principal Component Analysis and Multi-Dimensional Scaling Analysis of Korean Water Quality Index and Microbial Community Data)

  • 서경진;김주미;김민정;김성근;이지은;김인영;조경덕;고광표
    • 한국환경보건학회지
    • /
    • 제35권6호
    • /
    • pp.517-525
    • /
    • 2009
  • The water quality of Lake Shihwa had been rapidly deteriorating since 1994 due to wastewater input from the watersheds, limited water circulation and the lack of a wastewater treatment policy. In 2000, the government decided to open the tidal embankment and make a comprehensive management plan to improve the water quality, especially inflowing stream water around Shihwa and Banwol industrial complex. However, the water quality and microbial community have not as yet been fully evaluated. The purpose of this study is to investigate the influent water quality around the industrial area based on chemical and biological analysis, and collected surface water sample from the Siheung Stream, up-stream to down-stream through the industrial complex, Samples were collected in July 2009. The results show that the downstream site near the industrial complex had higher concentrations of heavy metals (Cu, Mn, Fe, Mg, and Zn) and organic matter than upstream sites. A combination of DGGE (Denaturing Gradient Gel Electrophoresis) gels, lists of K-WQI (Korean Water Quality Index), cluster analysis, MDS (Multi-Dimensional Scaling) and PCA (Principal Component Analysis) has demonstrated clear clustering between Siheung stream 3 and 4 and with a high similarity and detected metal reducing bacteria (Shewanella spp.) and biodegrading bacteria (Acinetobacter spp.). These results suggest that use of both chemical and microbiological marker would be useful to fully evaluate the water quality.

물리탐사를 이용한 국내 유류오염지역 조사 사례 (A geophysical survey result over a hydrocarbon contaminated site)

  • 송윤호;박삼규;설순지;조성준;정승환
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2001년도 정기총회 및 제3회 특별지포지움
    • /
    • pp.122-140
    • /
    • 2001
  • 유류오염물질의 매립 및 국부적인 유류누출에 의한 토양오염지역에서 시험탐사구역을 설정하고 전기, 전자탐사 기술을 위주로 물리탐사 기술을 적용하여 매설물 탐지 및 오염범위 규명 가능성을 시험하였다. 먼저 매설관로 및 매립지역의 탐지에는 GPR 탐사와 더불어 다중주파수 이동송수신 전자탐사가 매우 효과적인 것으로 판명되었다 한편 수직 및 수평구배 측정방식 자력탐사의 경우 지표에 많이 존재하는 금속 파편 등에 의한 반응이 우세하여 매설관로 등의 탐지는 어려웠다. 유류오염 범위의 규명을 위해서는 전기비저항 탐사와 전자탐사, GPR 탐사가 적용되었다. 먼저 전기비저항 탐사자료의 2차원 역산 결과 및 공간 필터링을 적용한 후의 전자탐사 자료의 1차원 역산 결과로부터 각각 심도별 전기비저항 분포 영상을 작성하였다. 유류오염대가 주변 실트층에 비해 전기비저항이 높다는 가정하에 고비저항 이상대의 분포범위를 해석하였는데, 전기비저항 탐사와 전자탐사자료가 서로 잘 일치하였으며, 시료분석에 의한 오염범위와 대체적으로 일치하였다. GPR 탐사에서는 이 지역의 오염 특성상 유류오염 Plume에 의한 반사신호 등은 기록되지 않았으며, 단지 신호 에너지의 투과심도로부터 오염지역을 추정하였는데, 전기 및 전자탐사자료 해석의 보조적인 정보 제공 수준이었다 이러한 결과로부터 유류오염부지 조사를 위한 물리탐사기술의 적용성을 정리하였고 효과적인 탐사 흐름도를 제시하였다.

  • PDF

국부의치 제작을 위한 보철의뢰 서식의 기록에 관한 임상적 연구 (A Study of Prosthetic Prescriptions sent to the Laboratories for Removable Partial Denture Framework)

  • 장익태
    • 대한치과보철학회지
    • /
    • 제18권1호
    • /
    • pp.7-13
    • /
    • 1980
  • The purpose of this study was to evaluate the removable partial denture prescriptions including surveyed crowns and design of component parts sent to the laboratory technician. A total of 351 casess with prescription forms and master cast in maxillary and mandibular semi-edentulous situations collected from dental laboratory by random sampling were selected for this study. The evaluation and study observed here involved the classification of edentulous situations, status of abutment splinting, form of rest seats and guiding plane of surveyed crows, location of maxillary major connectors and tripodig marks on the master casts. Removable partial denture prescriptions contained (1) general request (upper and lower cast framework), (2) types of metal, (3) location of retainer(retention, lingual bracing, rest area, guiding plane surface), (4) location and type of major connector, (5) relief area and amount, (6) and other specific instructions. The following informations based on the classified groups such as Group I was those cases sent with no real prescriptions. They say 'make a partial.' No prescriptions, no thought beforehand, Group II was those cases sent with a minimal prescriptions. They say 'make a partial with clasps on May be some preparations, usually inadequate. Group III was those cases sent with a moderately good prescription. Adequate but could be much better. No tripoding but it tell what clasps go where. Still not good prescriptions. Group IV was good cases, tripoded with adequate prescriptions and a prescription which exactly describes what is expected from the laboratory. The analyzed results were as follows: 1. The normal form of rest seats and guiding plane of surveyed crowns in Class. I and Class. II edentulous situations on the maxillary cast were observed 31.9% and 27.89%, respectively. The abutment teeth and retainer without occlusal rests of Class. I and Class. II were showed 11.58% and 8.86%, respectively. In mandibular cases, the normal form of rest seats and guiding plane of surveyed crowns showed 27.54% and 8.82% in Class. I and Class. II situation. The abutment teeth and retainer without rest seats were showed 15.19%, respectively. 2. The splinted surveyed crowns of Class. I and Class. II maxillary edentulous situations in distal extension cases were showed 34.51% and 28.85%, but 28.52% and 10.29%, respectively. 3. The location and type of maxillary major connector delineated on the master cast were 66 cases (44.89%). 4. The results of 351 cases were classified as Group I 146(41.59%), Group II 115 (32.76%), Group III 57 (16.23%), and Group IV 33 (9.48%). 5. The delineation of abutment tooth for clasping were 176 cases (50.14%) among total of 351 cases. 6. The delineation of height of contour line were showed 45 cases (12.8%) in Group II, 14 cases (3.98%) in Group III and 33 cases (9.40%) in Group IV with total 92 cases (26.21%). 7. In surveying procedure, the delineation of tripoding marks and reference line were showed 17 cases (4.84%).

  • PDF

기-액 계면에서 Palmitic Acid 단분자막에 대한 pH, 알칼리토금속 이온의 영향 및 Hexadecanol 분자와의 섞임성 (pH, Alkaline Earth Metal Ion Effects and Miscibility with Hexadecanol on the Monolayer of Palmitic Acid at the Air-Water Interface)

  • 정종재;서병일;이해원;주민영
    • 대한화학회지
    • /
    • 제37권3호
    • /
    • pp.294-301
    • /
    • 1993
  • 기-액 계면에서 Palmitic acid(PA) 단분자막의 ${\pi}$-A(surface pressure-area) 등온선 변화는 pH가 높을수록 가용화로 인하여 단위분자면적(${\AA}^2$/molecule)이 낮은 쪽으로 이동되었다. 바탕용액속에 Mg$^{2+}$, Ca$^{2+}$ 및 Ba$^{2+}$ 이온들을 각각 첨가했을 때 PA 분자는 압축되는 현상을 보였으며 이 효과는 이온의 농도 증가와 더불어 증가하였다. Langmuir-blodgett(LB) 다층막으로 IR 분광분석을 한 결과, PA는 이들이온과 각각 Mg, Ca, Ba-Palmitate 착물을 형성한다는 것을 알 수 있었다. 알칼리토금속 이온들에 의한 PA의 압축효과는 pH 8에서 Ca$^{2+}$ > Ba$^{2+}$ > Mg$^{2+}$ 순으로 나타났으며 Mg$^{2+}$ 을 제외하고는 원자번호 증가에 따라 감소되었다. 반면, 중성인 초순수 물에서는 Ba$^{2+}$ > Ca$^{2+}$ > Mg$^{2+}$ 순으로 나타났으며 이 현상은 원자번호가 낮아짐에 따라 감소하였다. 단분자막 상에서 PA와 HD(hexadecanol), 2성분계의 섞임성은 초순수 물인 계인 경우는 섞임성이 좋았으며 pH 8인 계의 경우는 섞임성이 나쁨을 알 수 있었다.

  • PDF

가간섭 영역 외의 배경 잡음성 간섭무늬 신호 필터링을 통한 백색광 주사간섭계의 성능 향상 (Interference Fringe Signal Filtering Method for Performance Enhancing of White Light Interfrometry)

  • 임해동;이민우;이승걸;박세근;이일항;오범환
    • 한국광학회지
    • /
    • 제20권5호
    • /
    • pp.272-275
    • /
    • 2009
  • 본 논문에서는 백색광 간섭계(White Light Interferometry, WLI)의 데이터 처리 과정에서 가간섭 영역 외의 배경 잡음성 신호 필터링을 통하여 백색광 주사 간섭계의 성능을 향상시켰다. 광학계의 개구수(Numerical Aperture, NA)가 유한한 백색광 간섭계의 경우, 단차가 크고 표면 굴곡이 심한 시료를 측정하게 되면 유한한 초점심도(Depth Of Focus, DOF)에 의하여 배경 잡음이 발생하며, 반사가 심한 경면의 경우에는 간섭무늬 신호보다 배경 잡음의 영향을 많이 받게 된다. 따라서 배경 잡음을 제거하기 위하여 간섭무늬 신호 자체 형상에 영향을 주지 않으면서 효율적으로 배경 잡음 필터링이 가능한 전후 구간 평균법을 제시하였다. 전후구간 평균법은 원 데이터와 그 이동평균과의 차이를 이용하는 방법으로, 고속으로 대략적인 정점의 위치를 파악한 후 정밀도가 높은 가시도 정점 검출 알고리즘으로 처리하여 측정 속도와 정밀도를 높였다. 전후구간 평균법을 이용하여 배경 잡음을 제거한 경우, 제거하지 않은 경우와 비교하여 잡음 화소가 약 1/4로 감소되었다.

PCITS에 의해 소손된 1Φ 2 W MCCB의 탄화 패턴 및 작동 특성 (Carbonization Patten and Operation Characteristics of a 1Φ 2 W MCCB Damaged by PCITS)

  • 이재혁;최충석
    • 한국화재소방학회논문지
    • /
    • 제28권5호
    • /
    • pp.8-13
    • /
    • 2014
  • 본 연구에서는 대전류공급장치시스템(PCITS)을 이용하여 열동전자식 배선용차단기(MCCB)에 과전류를 인가하였을 때 소손된 패턴을 해석하는 데 있다. MCCB의 트립바가 소손된 상태에서 PCITS로 과전류 150 A를 5 s 동안 흘렀을 때 우측에 위치한 온도 조절 장치의 표면이 심하게 탄화되었다. 동일한 조건에서 300 A의 과전류를 5 s 동안 흘렸을 때 온도 조절 장치의 전체가 열화(劣化)되어 납작하게 밀착되었다. 과전류 450 A를 5 s 동안 흘렸을 때 온도 조절 장치의 코일은 융융 및 단선이 발생하였다. 또한 접점, 외함 및 상부 덮개 등에서 탄화 흔적 및 변형이 확인되었다. 과전류600 A를 공급하고 3 s 정도가 경과되었을 때 MCCB의 내부에서 흰색 연기가 발생하였고, 불꽃이 외부로 방사되었다. 그리고 탁(딱)하는 소리와 동시에 과전류의 공급이 중단되었다. 동일한 MCCB를 일반 화염으로 소손시켰을 때 작동 손잡이, 단자, 소호 장치 및 온도 조절 장치 등의 표면에 탄화가 고르게 형성된 것을 알 수 있다. 또한 작동 기구부의 트립바는 녹아 흘러 내렸으며, 작동 금속핀은 트립 상태로 이동된 것이 확인된다.

경주(慶州) 황남동(皇南洞) 출토(出土) 철부(鐵釜)의 보존처리(保存處理) 및 과학적분석(科學的分析) (Scientific Analysis and Conservation Treatment of the Kettle Excavated from Hwangnam-dong, Gyeongju)

  • 문선영;전익환;유혜선
    • 박물관보존과학
    • /
    • 제4권
    • /
    • pp.23-32
    • /
    • 2003
  • 경주 황남동의 통일신라시대 생활유적에서 출토된 철솥을 유리공방에서 사용된 도가니로 추정하고 있어, 이에 대한 과학적인 분석을 통해 철솥의 용도를 밝혀보기로 하였다. 우선 보존처리를 실시해 철솥의 원형을 찾아주고, 철솥 표면에 발생한 부식물 5점에 대해 SEM-EDS 분석 및 XRD 분석을 수행하였다. 철솥의 외형에 있어 도가니로 추정하는 데 가장 큰 역할을 했던 주구부분의 편이 보존처리 과정에서 발견되어 구연부는 완전한 상태로 복원되었다. 금속시편의 조직을 관찰한 결과 열처리없이 서서히 냉각시킨 주조철제로 밝혀졌다. 부식물의 성분원소는 Fe과 O를 주성분으로 한 P, Si, Ca, S 등으로서, 주요 구성 화화물은 quartz, vivianite, goethite, akaganeite, lepidocrocite, hematite 등이었다. 이와 같은 구성 성분들은 유리의 제조원료로서 이들이 철솥 외부표면의 부식물층에서 용융상태가 아닌 원료로 확인되었다는 것은 철솥이 출토된 유적이 유리제조와 관련된 공방지였다는 것을 알려주는 증거가 될 수는 있으나, 철솥이 유리 용융 도가니로 사용되었다는 증거가 될 수는 없다. 또한 철솥 출토 당시 우물지 안에 퇴적되어 있던 유기물 부식토와 사질점토 등을 고려해 보면 이들이 철솥의 부식물 형성인자로 작용한 것으로 볼 수도 있다. 따라서 철솥은 전형적인 주조철제로 도가니로 사용되지는 않은 것으로 결론지을 수 있다.

불활성 가스하 열건조에 따른 금속시험편의 수소잔류물 거동 분석 (Variation of Hydrogen Residue on Metallic Samples by Thermal Soaking in an Inert Gas Environment)

  • 이윤희;박종서;백운봉;남승훈
    • 한국수소및신에너지학회논문집
    • /
    • 제24권1호
    • /
    • pp.44-49
    • /
    • 2013
  • Hydrogen penetration into a metal leads to damages and mechanical degradations and its content measurement is of importance. For a precise measurement, a sample preparation procedure must be optimized through a series of studies on sample washing and drying. In this study, two-step washing with organic solvents and thermal soaking in inert gas were tried with a rod-shaped, API X65 steel sample. The samples were machined from a steel plate and then washed in acetone and etyl-alcohol for 5 minute each and dried with compressed air. After then, the samples were thermally soaked in a home-made nitrogen gas chamber during 10 minute at different heat gun temperatures from 100 to $400^{\circ}C$ and corresponding temperature range in the soaking chamber was from 77 to $266^{\circ}C$ according to the temperature calibration. Hydrogen residue in the samples was measured with a hot extraction system after each soaking step; hydrogen residue of $0.70{\pm}0.12$ wppm after the thermal soaking at $77^{\circ}C$ decayed with increase of the soaking temperature. By adopting the heat transfer model, decay behavior of the hydrogen residue was fitted into an exponential decay function of the soaking temperature. Saturated value or lower bound of the hydrogen residue was 0.36 wppm and chamber temperature required to lower the hydrogen residue about 95% of the lower bound was $360^{\circ}C$. Furthermore, a thermal desorption spectroscopy was done for the fully soaked samples at $360^{\circ}C$. Weak hydrogen peak was observed for whole temperature range and it means that hydrogen-related contaminants of the sample surface are steadily removed by heating. In addition, a broad peak found around $400^{\circ}C$ means that parts of the hydrogen residue are irreversibly trapped in the steel microstructure.