• 제목/요약/키워드: Metal Ion

검색결과 2,179건 처리시간 0.03초

Synthesis of Poly(N-methylol Methacrylamide/Vinyl Sulfonic Acid) Hydrogels for Heavy Metal Ion Removal

  • Yakar, Arzu
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권10호
    • /
    • pp.3063-3070
    • /
    • 2014
  • In this study, poly(N-methylol methacrylamide) (NMMAAm) and poly(N-methylol methacrylamide/vinyl sulphonic acid) (NMMAAm-VSA) hydrogels were synthesized by $^{60}Co-{\gamma}$ ray irradiation at an ambient temperature. The graphs belonging to the gelation percent- percent-dose and swelling curves were drawn by using data which were obtained from water and different pH solutions. Characterization of hydrogels was performed by FTIR and DSC-TGA analysis. Heavy metal ion ($Ni^{2+}$, $Co^{2+}$) removal capacities of hydrogels were investigated in aqueous solutions, which had different concentrations (100-1500 mg/L). In metal ion removal studies, pH value of aqueous medium was kept constant at 5.0. Maximum metal ion removal values were obtained for NMMAAm-VSA (1:3 mole ratio) hydrogels. Metal ion removal capacities of NMMAAm-VSA (1:3 mole ratio) hydrogels were found as 82 mg/g and 98 mg/g for $Ni^{2+}$ and $Co^{2+}$ ions, respectively.

A calculation on the Metal-Film Mixing by Intense Pulse Ion Beam (IPIB)

  • Le, X.Y.;Yan, S.;Zhao, W.J.;Wang, Y.G.;Xue, J.M.
    • 한국진공학회지
    • /
    • 제12권S1호
    • /
    • pp.74-78
    • /
    • 2003
  • In this paper, we studied, by numerical calculation, a system, which was composed of metal-film and metal-substrate irradiated by IPIB with beam ion energy 250 keV, current density 10 to 250 A/$\textrm{cm}^2$. While the IPIB irradiation was going on, an induced effect named mixing occurred. In this case, metal-film and part of metal-substrate melted and mixed. The mixing state was kept as it was in melting phase due to the fast cooling rate. Our works were simulating the heating and cooling process via our STEIPIB program and tried to find proper parameters for a specific film-substrate system, 500 nmtitanium film coated on aluminum, to get best mixing results. The parameters calculated for such Ti-Al system were compared with the experimental results and were in good accordance to the experimental results.

Glass strengthening and coloring using PIIID technology

  • Han, Seung-Hee;An, Se-Hoon;Lee, Geun-Hyuk;Jang, Seong-Woo;Whang, Se-Hoon;Yoon, Jung-Hyeon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.178-178
    • /
    • 2016
  • Every display is equipped with a cover glass to protect the underneath displaying devices from mechanical and environmental impact during its use. The strengthened glass such as Gorilla glass.$^{TM}$ has been exclusively adopted as a cover glass in many displays. Conventionally, the strengthened glass has been manufactured via ion-exchange process in wet salt bath at high temperature of around $500^{\circ}C$ for hours of treatment time. During ion-exchange process, Na ions with smaller diameter are substituted with larger-diameter K ions, resulting in high compressive stress in near-surface region and making the treated glass very resistant to scratch or impact during its use. In this study, PIIID (plasma immersion ion implantation and deposition) technique was used to implant metal ions into the glass surface for strengthening. In addition, due to the plasmonic effect of the implanted metal ions, the metal-ion implanted glass samples got colored. To implant metal ions, plasma immersion ion implantation technique combined with HiPIMS method was adopted. The HiPIMS pulse voltage of up to 1.4 kV was applied to the 3" magnetron sputtering targets (Cu, Ag, Au, Al). At the same time, the sample stage with glass samples was synchronously pulse-biased via -50 kV high voltage pulse modulator. The frequency and pulse width of 100 Hz and 15 usec, respectively, were used during metal ion implantation. In addition, nitrogen ions were implanted to study the strengthening effect of gas ion implantation. The mechanical and optical properties of implanted glass samples were investigated using micro-hardness tester and UV-Vis spectrometer. The implanted ion distribution and the chemical states along depth was studied with XPS (X-ray photo-electron spectroscopy). A cross-sectional TEM study was also conducted to investigate the nature of implanted metal ions. The ion-implanted glass samples showed increased hardness of ~1.5 times at short implantation times. However, with increasing the implantation time, the surface hardness was decreased due to the accumulation of implantation damage.

  • PDF

산화·환원 전위 변화에 따른 도시폐기물 매립지 침출수의 수질 변화 특성 (The Characteristics of water Quality on MSW Landfill Leachate with variation of the Oxidation-Reduction Potential)

  • 허목
    • 유기물자원화
    • /
    • 제9권1호
    • /
    • pp.127-133
    • /
    • 2001
  • 미분해 유기물이 다량 존재하는 매립초기에 발생되는 침출수는 미생물에 의한 혐기성 소화가 진행됨에 따라 침출수중의 유황성분이 유황환원세균 등에 의해 황화물이온으로 환원되고, 이것이 금속이온의 양보다 과잉으로 많을 경우 sol화된 금속황화물이 되어 침출수를 검은색으로 변색시킴을 알 수 있었으며, 이들은 검은색의 입자상 물질을 형성하여 침전물을 생성함을 알 수 있었다. 따라서 이와 같은 침출수 처리를 위해 과잉의 황화물이온을 당량이상의 금속이온과 반응시킨다면 부동태화시킬 수 있다는 향후의 경제적 효율적인 처리를 위한 중요한 가능성을 확인할 수 있었다.

  • PDF

금속이온 착체에 의한 IMI-O 고분잔 LB막의 전기적 특성 (Electrical Properties of IMI-O Polymer LB Films in Complexed Metal Ion)

  • 정상범;유승엽;박재철;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1519-1521
    • /
    • 1997
  • In this paper, poly (N-(2-4-imidazolyl) ethyl) maleimide-alt-1-octadecene (IMI-O) polymer which can complex metal ion was used to confirm the possibility of molecular device made by Langmuir-Blodgett method. Metal/Insulator/Metal (MIM) device was fabricated for investigation of electric properties. In the ${\pi}$-A isotherm, surface pressure at collapse point was different as to the molecular weight of metal ion complexed respectively, In I-V characteristics, currents of MiM devices were different at the same voltage. It was thought that phenomena was occurred by interaction between function group and metal ion.

  • PDF

새로운 DBPDA 이온교환체를 사용한 알칼리 및 알칼리 토금속 이온들의 분리와 그의 이온교환 성질 (Separation of Alkali and Alkaline Earth Metal Ions Using Novel DBPDA Ion Exchanger and Its Ion Exchange Properties)

  • 김동원;김창석;최기영;전영신
    • 분석과학
    • /
    • 제6권3호
    • /
    • pp.261-265
    • /
    • 1993
  • 새로운 DBPDA이온교체, {(4,5):(13,14)-dibenzo-6, 9, 12-trioxa-3, 15, 21-triazabicyclo [15.3.1] heneicosa-1(21), 17, 19-triene-2, 16-dione : DBPDA 이온교환체}의 이온교환용량은 4.2meq/g이었다. 그리고 이 이온교환체에 대한 알칼리 및 알칼리 토금속 이온들의 분배계수를 여러 농도의 염산용액 중에서 측정하였다. 또한 DBPDA 이온교환체를 사용하여 알칼리 및 알칼리 토금속 이온들을 이온교환 컬럼 크로마토그라피로 분리하였다. 이러한 결과로부터 알칼리 및 알칼리 토금속 이온들의 분배계수에 미치는 용액의 pH와 금속 이온들의 이온반경 효과를 고찰하였다.

  • PDF

중금속(重金屬) 이온의 토양(土壤) 흡착에 관한 연구 -(제1보) CEC 및 유기탄소 함량이 낮은 광물토양에의 Cd, Cu, Ni, 및 Zn의 흡착과 이에 미치는 pH 및 인산의 효과- (Studies on Heavy Metal Ion Adsorption by Soils. -(Part 1) PH and phosphate effects on the adsorption of Cd, Cu, Ni and Zn by mineral soils with low CEC and low organic carbon content)

  • 김명종;해리.엘.마토
    • Applied Biological Chemistry
    • /
    • 제20권3호
    • /
    • pp.300-309
    • /
    • 1977
  • The information related to the heavy metal pollution in the environment was obtained from studies on the effects of pH, phosphate and soil properties on the adsorption of metal ions (Cd, Cu, Ni, and Zn) by soils. Three soil materials; soil 1 with low CEC (8.2 me/100g) and low organic carbon content (0.34%); soil 2 with high CEC (36.4 me/100g) and low organic carbon content (1.8%) and soil 3 with high CEC (49.9 me/100g) and high organic carbon content (14.7%) were used. Soils were adjusted to several pH's and equilibrated with metal ion mixtures of 4 different concentrations, each having equal equivalents of each metal ion (0.63, 1.88, 3.12 and 4.38 micromoles per one gram soil with and without 10 micromoles of phosphate per one gram soil). Reported here are the results of the equilibrium study on soil I. The rest of the results on soil 2 and soil 3 will be repoted subsequeutly. Generally higher metal ion concentration solution resulted in higher final metal ion concentrations in the equilibrated solution and phosphate had minimal effect except it tended to enhance removal of cadmium and zinc from equilibrated solutions while it tended to decrease the removal of copper and nickel. In soil 1, percentages of added metal ions removed at pH 5.10 were; Cu 97, Ni 69, Cd 63, and Zn 55, while increasing pH to 6.40, they were increased to Cu 90.9, Zn 99, Ni 96, and Cd 92 per As initial metal ion concentration increased, final metal ion concentrations in the equilibrated solution showed a relationship with pH of the system as they fit to the equation $p[M^{++}]=a$ pH+b where $p[M^{++}]=-log$[metal ion concentration in Mol/liter]. The magnitude of pH and soil effects were reflected in slope (a) of the equation, and were different among metal ions and soils. Slopes (a) for metal ions in the aqueous system are all 2. In soil 1 they were; Zn 1.23, Cu 0.99, Ni 0.69 and Cd 0.59 at highest concentration. The adsorption of Cd, Ni, and Zn in soil 1 could be represented by the Iangmuir isotherm. However, construction of the Iangmuir isotherm required the correction for pH differences.

  • PDF

초내식성 스테인레스강의 금속이온용출특성 및 세포적합성 (Metal Ion Release Behaviour and Cytotoxicity of a Super Stainless Steel)

  • 김철생;박진수;허억;강곤
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.11-18
    • /
    • 1996
  • The toxic metal ion release behaviour and the cytotoxicity of a super stainless steel (S.S.S, 22cr-20Ni -6Mo-0.25N) were investigated The measurement of the amount of static and wear- induced trace metal ion released from the steels was conducted in Hank's balanced salt solution using an electrothermal atomic absdrption spectrometry equiped with Uaphite furnace. And the in vitro cytotoxicity of the materials was assesed in cell culture. The static dissolution rates of Fe and Cr ions from the S.S.S were significantly lower than those of 316L SS. However, the Ni ion release from the S.S.S during the first 4 weeks was yester than that from 316L 55 by 15-45%. Also, the wear-in- duces dissolution rates from the steels were not correlated either with their elemental composition rates or with the static metal ion release rates. The S.S.S did not deteriorate the osteoblasts viability. And no toxic response was observed from the macrophages cultured for 7 days in RFMI 1640 medium immersed with the S.S.S specimens.

  • PDF

Metal Ion Selectivity of Surface Templated Resins Carrying Phosphate Groups

  • Murata, Masaharu;Maeda, Mizuo;Takagi, Makoto
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.529-534
    • /
    • 1995
  • The metal ion selective resins were prepared by surface template polymerization using monooleyl phosphoric acid (1), oleyl methyl phosphoric acid (2) or oleyl ethyl phosphoric acid (3) as an amphiphilic host surfactant. The $Cu^{2+}$-imprinted resins prepared in the presence of $Cu^{2+}$ adsorbed $Cu^{2+}$ much more effectively than did their reference resins. On the other hand, the $Cu^{2+}$-imprinted resins showed much less binding ability to $Zn^{2+}$. The template-dependent selectivity should be ascribed to a favorable placement of the surface-anchored metallophilic groups for multidentate coordination to specific metal ion.

  • PDF