• Title/Summary/Keyword: Mesurement

Search Result 78, Processing Time 0.022 seconds

Implementation and Performance Analysis of Real-Time DGPS & RTK Error Correction Data Transmission System for Long-Distance in Mobile Environments (모바일 환경에서 DGPS 및 RTK 보정 데이터 실시간 장거리 전송 시스템의 구현 및 성능 분석)

  • 조익성;임재홍
    • Korean Journal of Remote Sensing
    • /
    • v.18 no.6
    • /
    • pp.345-358
    • /
    • 2002
  • DGPS(Differential Global Positioning System) and RTK(Real time Kinematic) are in one of today's most widely used surveying techniques. However surveying with these techniques is restricted by the distance between reference and rover station, and it is difficult to process data in realtime by their own organizational limitation in precise measurement of positioning. To meet these new demands, in this paper, new DGPS and RTK correction data services through the Internet and PSTN(Public Switched Telephony Network) have been proposed. For this purpose, a DGPS and RTK error correction data transmission system is implemented for long-distance using the Internet and PSTN which allows a mobile user at which the rover receiver is located to receive the correction data from the reference in realtime, and analyzed and compared with DGPS and RTK performances by experiments through the Internet and PSTN for the distance and the time.

Aplication of the Thermodynamic Measurement Method for On-site Performance Evaluation of Hot Water Pumps Used in District Heating (지역난방 중온수 펌프의 현장 성능평가를 위한 열역학적 측정법 적용)

  • Park, Cheol Gyu;Yoo, Hoseon
    • Plant Journal
    • /
    • v.17 no.1
    • /
    • pp.50-57
    • /
    • 2021
  • It is very difficult to accurately calculate efficiency of each accessory device constituting the pump system and pump efficiency by the Conventional efficiency measurement method only. Therefore, this study introduced the lastest Thermodynamic pump efficiency measurement method in the district heating pump system for the first time in Korea. As a result, data uncertainty was high by the Conventional method, but the pump and Hydraulic Coupling efficiency values applied the Thermodynamic and Conventional method parallel measurement data were able to derive meaningful results that verified the reliability and adequancy of the pump performance measurement method by performing complementary roles. In additon, as a result of applying the Thermodynamic method to the distirct heating pump system, despite the high temperature environment of up to 120 ℃, it was possible to verify the reliability of the Thermodynamic method, such as high stable data mesurement, and durability of the measurement equipment.

Design of Facial Image Data Collection System for Heart Rate Measurement (심박수 측정을 위한 안면 얼굴 영상 데이터 수집 시스템 설계)

  • Jang, Seung-Ju
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.7
    • /
    • pp.971-976
    • /
    • 2021
  • In this paper, we design a facial facial image data collection system for heart rate measurement using a web camera. The design content of this paper is a function of collecting user face image information using a web camera and measuring heart rate using the user's face image information. There is a possibility that an error may occur due to non-contact heart rate measurement using a web camera. Therefore, in this paper, it is to be used for correcting heart rate program errors through classification of data in cases of error and normal. The data in case of error can be used for the purpose of reducing the error. Experiments were conducted on the proposed ideas and designed in this paper. As a result of the experiment, it was confirmed that it operates normally.

Comparative Study About The Indirect Blood Pressure (measured by different Instruments and Methods) (측정도구와 방법에 따른 간접혈압측정치의 비교연구)

  • Suh Gil-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.1 no.1
    • /
    • pp.51-68
    • /
    • 1994
  • One aim of this study was to find out the difference of indirect blood pressure between the types of instruments. The difference of indirect blood pressure was measured with mercury sphygomomanometer and electronic blood pressuremeter. Another was to determine the difference of indirect blood pressure according to width of cuff and site of cuff. Indirect blood pressures were measured with the diaphragmatic side of sphygomomanometer. The subjects were 40 female volunteers, whose arm circumferences were from 22 to 34cm. The data were analyzed by SPSS-PC program and pared t-test was used. The results are summarized as follows ; 1. Mercury sphygomomanometer systolic pressure was higher(average 2.20mmhg) than electronic blood pressuremeter. It was statistically significant(p=0.026). 2. The value of Mercury sphygomomanometer diastolic pressure was lower(2.00mmhg) than electronic's. It was statistically significant(p=0.03) 3. In the mercury sphygomomanometer systolic pressure, the value of standard cuff($12{\times}23cm$) was higher(2.40mmhg) than large one's($14{\times}45cm$). It was statistically significant(p=0.007). 4. In diastolic pressure(K4), the value of standard cuff was higher(0.65mmhg) than large cuff's. It was not statistically significant(p=0.481). In K5, the value of standard cuff($12{\times}23cm$) was higher(0.55mmhg) than large cuff's. It was not statistically significant(p=0.541). 5. Difference according to site of showed that the values of systolic pressure over elbow joint were higher(20.00mmhg, 26.45mmhg) than ones at site of elbow joint. It was significant statistically(p=0.000) and clinically. 6. The values of diastolic pressure(K4) over elbow joint were higher(17.10mmhg, 21.60mmhg) than ones at site of elbow joint. It was significant statistically (p=0.000) and clinically. The values of K5 over elbow joint were higher(17.25mmhg, 22.15mmhg) than ones at site of elbow joint. It was significant statistically(p=0.000) and clinically. I think similar studies about indirect blood pressure according to diseases and positions are necessary. In addition, similar studies, are required about accuracy of method electronic blood pressuremeter according to site of mesurement.

  • PDF

A Study on the Provenance of the Stones and the Surface Cracks in the Suljeongri East Three-story Stone Pagoda, Changnyeong, Korea (창녕 술정리 동삼층석탑 석재의 원산지 해석 및 표면균열에 관한 연구)

  • Kim, Jae-Hwan;Jwa, Yong-Joo
    • The Journal of the Petrological Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.283-292
    • /
    • 2010
  • The Suljeongri east three-story stone pagoda in Changnyeong (National Treasure No. 34) has been damaged mainly by lots of cracks. The stones used for this pagoda are medium-granied equigranular pinkish biotite granite. Measured magnetic susceptibility values are of from 2 to 9 (${\times}10^{-3}$ SI unit). From the ${\gamma}$-ray spectrometer mesurement K, eU, and eTh contents of the stones are 3 to 7%, 8 to 19 ppm, and 11 to 35 ppm, respectively. Comparing the petrographical and chemical characteristics between the stones of the pagoda and the country rocks near Suljeongri, it is suggested that the most similar rock could be equigranular biotite granite in the western slope of the Mt. Hwawangsan. Vertical, horizontal and diagonal cracks are intensely developed at the lower part of the stone pagoda. Biotite granite has intrinsic microcracks defined as rift and grain rock cleavages. Both rock cleavages are assumed to have led to the crack growth and consequent mechanical damage of the pagoda. It seems that vertical cracks have been grown parallel to the principal compressional stress, and that horizontal cracks to the reacting tensional stress. Diagonal cracks seems likely to have been resulted from conjugate rift and grain rock cleavages.

Studies on Scintillation Proximity Assay for the mesurement of alpha-hCG (Alpha-hCG 측정을 위한 섬광 근접 측정법 (Scintillation Proximity Assay)에 관한 연구)

  • Choi, Tae-Hyun;Lim, Sang-Moo;Choi, Chang-Woon;Chung, Wee-Sup;Lim, Soo-Jeong;Lee, Su-Jin;Lee, Tae-Sup;Awh, Ok-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.2
    • /
    • pp.133-139
    • /
    • 2002
  • Purpose: Scintillation Proximity Assay (SPA) does not require the physical separation of receptor bound form from free form. SPA was applied to the study of interaction of human chorionic gonadotropin (hCG) and $anti-{\alpha}$ hCG in serum. Materials and methods: $Anti-{\alpha}$ hCG was biotinylated for the binding to streptavidin. The assay was based on the simple competitive binding method between $[^{125}I]hCG$ and the hCG in sample serum, with $anti-{\alpha}$ hCG-coated beads. Aliquots of biotinylated $anti-{\alpha}$ hCG were dispensed into scintillation vials containing $100{\mu}{\ell}\;[^125}I]hCG\;and\;200{\mu}{\ell}$ of either a standard concentration of hCG for preparation of standard curve or unknown sample, and incubated for 20 min. at room temperature. Then $20{\mu}{\ell}$ streptavidin-coated beads were added to vials, and finally incubated for 10 min at room temperature. Values for unknown samples were then calculated from the standard curve. Results: Optimal background counts were certificated using varied radioactivity of radionuclides. Appropriate standard curve was obtained from SPA method successively, and the concentration of hCG from unknown serum was determined by standard curve. The result from SPA assay was similar to that of RIA. Conclusion: This observation confirms that SPA method could be useful for clinical diagnosis.

The Analysis of the Factors and Weights for the Performance Mesurement of Hospital CRM System (병원의 CRM시스템 성과측정을 위한 주요요인 및 가중치 분석)

  • Hong, Hyun-Gi;Chun, Je-Ran
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.4
    • /
    • pp.915-923
    • /
    • 2007
  • Recently we can see many cases that the CRM Systems are implemented and operated in Hospitals. The reason for such situation is the management environments in medical service market is changing rapidly one hand, and on the other hand the competitions among the Hospitals became more severe. In this paper we try to present the factors and weights as index for the measurement of Hospital CRM's System Performance. To achieve this goal, we derived the primary factors for the success of the CRM Systems based on the precedent researches, and futhermore carry out the verification of the rightness of those factors. For the verification of the rightness of the factors, we employ the Structured-Model-Analysis Method of AMOS. This enhance the meaning of the analysis result of the factors. And we use the AHP method to compare the importance grade of each success factors, because the comparison of importance level of each success factor is very crucial for the measurement of the Hospital CRM's system performance. As a result, we derived the primary factors and analyzed the weights in this paper, which might be used as the guiding Index for the measurement of the Hospital CRM' System Performance.

  • PDF

A Study on the Development of Capacitor Exchange Type GDU of Propulsion Control Device of Electric Railway Vehicle Capable of Life Diagnosis (수명진단이 가능한 전기철도차량 추진제어장치의 커패시터 교환 형 GDU 개발에 관한 연구)

  • Kim, Sung Joon;Chae, Eun Kyung;Kang, Jeong Won
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.7
    • /
    • pp.475-484
    • /
    • 2018
  • The propulsion control device of an electric railway vehicle is a key main component corresponding to an engine of an automobile, and a device for controlling this is a device called a GDU (Gate Drive Unit). Also, when the frequency of failure of the propulsion control system was analyzed, the nonconformity ratio of GDU was the highest. GDU was not able to access core technologies due to the introduction of foreign products, and there were general problems with overall maintenance activities due to discontinuation of GDU of the manufacturer. The GDU has reached the end of its life with 23 to 14 years of long-term use.In order to solve these problems, this study was designed to identify the proper life span by analyzing compatible GDU's acquisition and failure, and to improve the existing system of maintenance focusing on health inspection. Maintenance of the components with a short life span compared to the entire service life is essential. Most foreign parts introduced at the beginning of the construction are not replaced due to technical problems or long-term operation. However, due to the characteristics of railway vehicles with a long life span of more than 25 years, it is necessary to maintain them for a long period of time. The study should be more concrete and empirical. The replacement type GDU of capacitors was able to easily measure the life of the capacitance by removing the capacitor modules, measure the life span of each unit test, and accurately perform preventive maintenance of the capacitor.