• Title/Summary/Keyword: Mercury measurement

Search Result 88, Processing Time 0.028 seconds

Development of soil certified reference material for determination of the hazardous elements (유해원소 측정용 토양 인증표준물질 개발)

  • Kim, In-Jung;Min, Hyung-Sik;Suh, Jung-Ki;Han, Myung-Sub;Lim, Myung-Chul;Kim, Young-Hee;Shin, Sun-Kyoung;Cho, Kyung-Haeng
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.485-491
    • /
    • 2010
  • A certified reference material (CRM) of KRISS 109-03-SSD was developed for the analysis of hazardous elements in soil. The target elements were As, Cd, Cr, Cu, Hg, Ni, Pb, Zn being regulated by the Soil Environment Conservation Act. Starting material was collected from tailing dump of an unworked tungsten mine at Sangdong (Gangwon-do, Korea). The starting material under-went through a series of fabricating process steps of screening, drying, grinding, sieving, blending, bottling, sterilization and was certified according to the ISO Guide 35. Isotope dilution-inductively coupled mass spectrometry (ID-ICP/MS) and instrumental neutron activation analysis (INAA) were used for the measurement. Homogeneity was tested according to ISO 13528 annex B. The certified values were determined using the results from two different methods or from two independent measurements using a method. Finally, certified values of seven elements of arsenic, cadmium, chromium, copper, lead, nickel and zinc were determined. Mercury did not satisfied the criteria of homogeneity and the result would be provided for information only, together with iron and tungsten. It was also studied, the extractable fraction of elements by aqua regia according to the ISO 11466 protocol being frequently studied for the purpose of environmental monitoring. It was performed as a inter-laboratory study by 6 laboratories of a public institute and universities. Standard deviation among the laboratories was much bigger than the uncertainty of the certified value. The result of inter-laboratory study on the extractable fraction will be provided for information, only.

Characterization of New Avalanche Photodiode Arrays for Positron Emission Tomography

  • Song, Tae-Yong;Park, Yong;Chung, Yong-Hyun;Jung, Jin-Ho;Jeong, Myung-Hwan;Min, Byung-Jun;Hong, Key-Jo;Choe, Yearn-Seong;Lee, Kyung-Han
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.45-45
    • /
    • 2003
  • The aim of this study was the characterization and performance validation of new prototype avalanche photodiode (APD) arrays for positron emission tomography (PET). Two different APD array prototypes (noted A and B) developed by Radiation Monitoring Device (RMD) have been investigated. Principal characteristics of the two APD array were measured and compared. In order to characterize and evaluate the APD performance, capacitance, doping concentration, quantum efficiency, gain and dark current were measured. The doping concentration that shows the impurity distribution within an APD pixel as a function of depth was derived from the relationship between capacitance and bias voltage. Quantum efficiency was measured using a mercury vapor light source and a monochromator used to select a wavelength within the range of 300 to 700 nm. Quantum efficiency measurements were done at 500 V, for which the APD gain is equal to one. For the gain measurements, a pencil beam with 450 nm in wavelength was illuminating the center of each pixel. The APD dark currents were measured as a function of gain and bias. A linear fitting method was used to determine the value of surface and bulk leakage currents. Mean quantum efficiencies measured at 400 and 450 nm were 0.41 and 0.54, for array A, and 0.50 and 0.65 for array B. Mean gain at a bias voltage of 1700 V, was 617.6 for array A and 515.7 for type B. The values based on linear fitting were 0.08${\pm}$0.02 nA 38.40${\pm}$6.26 nA, 0.08${\pm}$0.0l nA 36.87${\pm}$5.19 nA, and 0.05${\pm}$0.00 nA, 21.80${\pm}$1.30 nA in bulk surface leakage current for array A and B respectively. Results of characterization demonstrate the importance of performance measurement validating the capability of APD array as the detector for PET imaging.

  • PDF

Preparation and Characterization of Hyaluronic Acid Loaded PLGA Scaffold by Emulsion Freeze-Drying Method (히알루론산을 함유한 PLGA 지지체의 제조 및 특성결정)

  • Ko, Youn-Kyung;Kim, Soon-Hee;Jeong, Jae-Soo;Park, Jung-Soo;Lim, Ji-Ye;Kim, Moon-Suk;Lee, Hae-Bang;Khang, Gil-Son
    • Polymer(Korea)
    • /
    • v.31 no.6
    • /
    • pp.505-511
    • /
    • 2007
  • Poly(lactide-co-glycolide)(PLGA) and hyaluronic acid (HA) has been widely used as biocompatible scaffold materials to regenerate tissue. In this present study, we fabricated microporous PLGA and HA loaded PLGA scaffolds by a emusion freeze-drying method. In order to confirm that the release profile of cytokine or water-soluble drugs, we manufactured the granulocyte macrophage colony stimulating factor(GM-CSF) loaded PLGA and HA-PLGA scaffold. All scaffolds were characterized using scanning electron microscope(SEM), mercury porosimeter and wettability measurement. Cell proliferation and viability were assessed by a 3-(4,5-dimethylthiazole-2-yl)-2,5-diphenyltetrazolium-bromide (MTT) test. The porosity of HA-PLGA scaffold was greater than 95% with the total pore area of $261\;m^2/g$. The HA-FLGA scaffold exhibited well interconnected pores to allow greater cell adhesion and prolixferation. It was proven by higher cell viability in the HA-PLGA scaffold than PLGA alone. This may be due to the enhanced natural properties and higher water retention capacity of HA.

Study on Optical Characteristics of 8-Hydroxyquinoline Synthesized Derivative as Sensing Material of the Fiber-Optic Copper Ion Sensor in Aqueous Environment (수질환경에서 광섬유 센서의 구리 이온 감지 물질로서 8-Hydroxyquinoline 합성유도체의 광학적 반응 특성 연구)

  • Kim, Beom Kyu;Park, Byung Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.100-105
    • /
    • 2017
  • An 8-hydroxyquinoline compound that was synthesized with 8-hydroxyquinoline-2-carboxaldehyde and 4-aminoantipyrine was investigated for use as the sensing material of a fiber-optic copper ion sensor in an aqueous environment. The experiment was conducted with a fiber-optic measurement system, in order to evaluate the relationship between the absorbance peak and copper ion concentration. The synthesized derivative exhibited a (highly selective) chromogenic phenomenon for copper ions among various metal ions in an aqueous environment and showed a specific absorbance peak at a wavelength of 530 nm for copper ions. The effect of mercury ions was investigated to evaluate the selectivity of the prepared synthesized derivatives toward Cu ions. The absorbance was measured at various concentration ratios of Cu and Hg ions (Cu:Hg ratios from 0.05 to 20), and it was found that the absorbance at 530 nm tended to increase with increasing Cu ion concentration. The experimental results also showed the linear relationship between the logarithmic concentration of copper ions and the specific absorbance peak at a wavelength of 530 nm. These results indicate that the synthesized 8-hydroxyquinoline compound has selectivity for copper ions and can be used as a sensing material for fiber-optic copper ion sensors.

Study on the Production Methods and Conservation Treatment of the Gold Earrings Excavated from the Ancient Tombs in Seokchon-dong in Seoul (석촌동 고분군 출토 금제이식의 제작기법 연구 및 보존처리)

  • Kim, Yeseung;Jeong, Seri;Lee, Dahye;Jang, Minkyeong;Kim, Naeun;Yang, Seokjin
    • Conservation Science in Museum
    • /
    • v.26
    • /
    • pp.143-160
    • /
    • 2021
  • The Seoul Baekje Museum has been conducting excavations at the Ancient Tomb Complex in Seokchon-dong, Seoul (Historic Site No. 243), known to be tombs of the royal family and the ruling class during the Hanseong period of the Baekje Kingdom. In this study, gold earrings that were revealed during the excavation underwent scientific analysis and conservation treatment. Stereo microscopy, SEM, X-ray imaging, CT, and XRF were applied in the analysis, and the characteristics, internal structure, and composition of the earrings as well as their production method were investigated. The results confirmed that the main hoops of the gilt-bronze earrings were made of copper cores gilt using mercury amalgamation. The findings also revealed that the hexahedron in the middle pendant was made by connecting small rings using molten gold powder, and the pendant sphere at the end was formed by soldering two hemispheres. As for the two thin-hoop earrings, they showed similar surface compositions but were made using different methods, with one made from a copper core wrapped with a gold plate and the other made by bending a gold rod. The gold content varied depending on the item and the place of measurement, but overall the earrings showed a relatively high gold content of approximately 19 to 21K. The purity of the golden earrings and the sophisticated manufacturing techniques applied indicate the high status of the buried person and of the tomb complex in Seokchong-dong.

An Experimental Study on Electromagnetic Properties in Early-Aged Cement Mortar under Different Curing Conditions (양생조건에 따른 초기재령 시멘트 모르타르의 전자기 특성에 대한 실험적 연구)

  • Kwon, Seung-Jun;Song, Ha-Won;Maria, Q. Feng
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.737-746
    • /
    • 2008
  • Recently, NDTs (Non-Destructive Techniques) using electromagnetic(EM) properties are applied to the performance evaluation for RC (Reinforced Concrete) structures. Since nonmetallic materials which are cement-based system have their unique dielectric constant and conductivity, they can be characterized and changed with different mixture conditions like W/C (water to cement) ratios and unit cement weight. In a room condition, cement mortar is generally dry so that porosity plays a major role in EM properties, which is determined at early-aged stage and also be affected by curing condition. In this paper, EM properties (dielectric constant and conductivity) in cement mortar specimens with 4 different W/C ratios are measured in the wide region of 0.2 GHz~20 GHz. Each specimen has different submerged curing period from 0 to 28 days and then EM measurement is performed after 4 weeks. Furthermore, porosity at the age of 28 days is measured through MIP (Mercury Intrusion Porosimeter) and saturation is also measured through amount of water loss in room condition. In order to evaluate the porosity from the initial curing stage, numerical analysis based on the modeling for the behavior in early-aged concrete is performed and the calculated results of porosity and measured EM properties are analyzed. For the convenient comparison with influencing parameters like W/C ratios and curing period, EM properties from 5 GHz to 15 GHz are averaged as one value. For 4 weeks, the averaged dielectric constant and conductivity in cement mortar are linearly decrease with higher W/C ratios and they increase in proportion to the square root of curing period regardless of W/C ratios.

Case Study on Determination of the Level of New RoHS II Substances in Domestic Electronic and Electrical Equipments (국내 전기전자 제품에 함유된 신규 RoHS II 물질 검출 사례 연구)

  • Song, Moon-Hwan;Son, Seung-Hwan;Cho, Young-Dal;Choe, Eun-Kyung
    • Clean Technology
    • /
    • v.17 no.2
    • /
    • pp.124-133
    • /
    • 2011
  • In addition to six substances regulated in EU RoHS including lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) and polybrominated diphenyl ethers (PBDE), priority substances are identified in new RoHS II as hexabromocyclododecane (HBCDD), dibutyl phthalate (DBP), butyl benzyl phthalate (BBP) and diethylhexyl phthalate (DEHP). In this study, 20 plastic samples were collected from 12 domestic electrotechnical companies and levels of four restricted substances were determined by gas chromatography-mass spectrometry, Among 20 parts that compose washer, refrigerator or microwave oven, HBCDD was detected in three samples of NBR material with the amount of 42~381 mg/kg while DBP and BBP was not detected in any samples collected respectively, implying that these substance may not be used widely in plastic materials for EEE. However, DEHP was detected in all samples of NBR, PP, PBT, EPDM and PVC materials with the amount of 42 up to 59,400 mg/kg that exceeds the limit value of 0.1 wt% (1,000 mg/kg). Presence of a restricted substance in polymer material makes a great negative influence on a number of final product. To cope with coming RoHS II as well as REACH, action not to use DEHP in plastic material or the relevant notification in case of REACH seems to be needed. Screening test of Arsenic compounds such as diarsenic pentaoxide, diarsenic trioxide, lead hydrogen arsenate, triethyl arsenate that are included in REACH SVHC was done by ICP measurement Arsenium was detected in four samples made of NBR and PBT materials in the level of 15~700 mg/kg. By considering the screening method used in this study, the amount of arsenium compounds in the thermistor made of PBT material has a high chance of exceeding the regulated limit value.

Evaluating and managing hypertension in children: a survey of Korean cardiologists and nephrologists (소아 고혈압의 평가와 관리 방법; 한국 소아심장 전문의와 소아신장 전문의 설문)

  • Lee, Eun Hee;Yim, Hyung Eun;Jang, Gi Young;Yoo, Kee Hwan;Son, Chang Sung;Hong, Young Sook;Lee, Joo Won
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.9
    • /
    • pp.992-997
    • /
    • 2008
  • Purpose : Hypertension (HTN) is no longer an exclusively adult disease; the prevalence of pediatric HTN is increasing. To understand the evaluation and treatment of childhood HTN in Korea, we investigated, via a questionnaire, how hypertensive children are currently assessed and managed by pediatric cardiologists (CA) and nephrologists (NE). Methods : We surveyed 82 pediatric CA and 77 NE, regarding how they manage hypertensive children in Korea. Results : A total 75 replies were received to our questionnaire request (response rate: 47.15%). Routine blood pressure (BP) checks were more frequently performed by NE (CA: 5.7%, NE: 25%, P=0.03), but most respondents (86%) did not check BP routinely. Mercury sphygmomanometers were the most commonly used devices and ambulatory blood pressure monitoring was not frequently used. The goal BP in treated patients was set at the 95th percentile by 61% of respondents. NE used a lower BP goal in hypertensive children with renal disease (CA: 24%, NE: 64%, P=0.004) or DM (CA: 12.5%, NE: 50%, P=0.003). Angiotensin converting enzyme (ACE) inhibitors were the most commonly used agents (mean: 59%); following ACE inhibitors, CA preferred diuretics for hypertensive children with renal disease or cardiovascular disease, and NE preferred calcium channel blockers, regardless of underlying disease. Self-monitoring was the most frequent method for BP monitoring at home. Conclusion : In Korea, BP measurement is not yet a routine examination in treating hypertension. There are some differences in management strategies vis-$\grave{a}$-vis hypertension, between pediatric cardiologists and nephrologists. For the appropriate management and prevention of secondary disease in long-term studies, standard guidelines and education are needed for pediatricians.