• 제목/요약/키워드: Mercury ion

검색결과 92건 처리시간 0.011초

KPFM을 통한 수은이온 검출 방법 (Mercury ion detection technique using KPFM)

  • 박찬호;장규환;이상명;유준석;나성수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.358-360
    • /
    • 2014
  • For the several decades, various nanomaterials are broadly used in industry and research. With the growth of nanotechnology, the study of nanotoxicity is being accelerated. Particularly, mercury ion is widely used in real life. Because the mercury is representative high toxic material, it is highly recommended to detect the mercury ion. In previous reported work, thymine-thymine mismatches (T-T) capture mercury ion and create very stable base pair ($T-Hg^{2+}-T$). Here, we performed the high sensitive sensing method for direct label free detection of mercury ions and DNA binding using Kelvin Probe Force Microscope (KPFM). In this method, 30 base pairs of thymine (T-30) is used for mercury specific DNA binding ($T-Hg^{2+}-T$). KPFM is able to detect the mercury ion because there is difference between bare T-30 DNA and mercury mediated DNA ($T-Hg^{2+}-T$).

  • PDF

Mercury Ion Monitoring in Mercury Plating Bath by Anodic Stripping Voltammetry

  • Park, Mijung;Yoon, Sumi;Shin, Woonsup
    • Journal of Electrochemical Science and Technology
    • /
    • 제7권3호
    • /
    • pp.241-244
    • /
    • 2016
  • Anodic stripping voltammetry (ASV) is successfully applied in mM level detection of mercury ion in an electroplating bath which is currently used in preparing a cathodic electrolyzer. Glassy carbon electrode is used for the detection and the optimum condition obtained is 10 s deposition at −1.4 V vs. Ag/AgCl and stripping by scanning from −1.4 to +0.4 V vs Ag/AgCl at 50 mV/s. By applying the method, the mercury ion concentration in the electroplating bath could be successfully monitored during the plating.

화학발광법에 의한 수용액 중의 선택적 수은(II) 이온 정량 (Selective determination of mercury (II) ion in aqueous solution by chemiluminescence method)

  • 김경민;장택균;김영호;오상협;이상학
    • 분석과학
    • /
    • 제24권4호
    • /
    • pp.243-248
    • /
    • 2011
  • 루미놀 화학발광 시스템(luminol-$H_2O_2$)을 이용하여 수용액 중의 수은(II) 이온을 선택적으로 정량분석 하였다. 루미놀과 과산화수소의 반응에서 촉매작용을 하는 구리(II), 철(III), 크롬(III) 이온 등 다양한 금속이온의 농도를 정량분석한 연구결과가 보고되어 있다. 본 연구에서는 수은(II) 이온이 루미놀과 과산화수소의 반응에서 다른 금속이온과 같이 촉매작용을 하는 것을 관찰하였으며, 수용액 중 수은(II) 이온의 정량분석 조건을 최적화하기 위하여 반응시간, pH등에 따른 영향을 조사하였다. 또한 수은이온이 갖는 1가와 2가 산화수 중에서 수은(I) 이온은 루미놀과 과산화수소의 반응에 있어서 촉매작용을 하지 않았을 뿐만 아니라 반응에 어떠한 영향도 미치지 않았다. 또한 수은(I)과 수은(II) 이온이 공존하는 수용액 중의 수은(II) 이온의 분석과정에서 수은(I) 이온의 방해 효과는 관찰되지 않았다. 이를 바탕으로 하여 루미놀 화학발광 시스템을 이용하여 수용액 중의 수은(II) 이온만 선택적으로 분석하는 것이 가능하다는 결과와 함께 화학발광분석법과 ICP분석법으로부터 얻은 실험결과를 비교하여 수용액 내에 존재하는 수은 이온의 산화수별 농도를 확인할 수 있다. 루미놀 화학발광 시스템의 최적 분석조건 하에서, 수용액 중의 선택적 수은(II) 이온의 정량분석을 위해 얻은 검정곡선에서 직선성이 성립하는 농도범위는 $1.25{\times}10^{-5}{\sim}2.50{\times}10^{-3}M$이며, 이때 상관계수는 0.991이고, 검출한계는 $1.25{\times}10^{-7}M$이었다.

형광화학센서를 이용한 용출기반 토양 수은 오염조사 (Determination of Mercury Ion in Contaminated Soil by Rhodamine B Hydrazide)

  • 김경태;박준범
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제21권3호
    • /
    • pp.1-5
    • /
    • 2016
  • Rhodamine B Hydrazide as a novel fluorescent and colorimetric probe exhibiting remarkably selective fluorescence enhancement toward Hg2+ ion over other 16 metal ions is herein introduced. The probe reacts with Hg2+ ion followed by its spirolactam ring-opening to give a remarkable enhancement of absorption maximum at 550 nm as well as an enhanced fluorescence intensity at 580 nm in aqueous media. Upon titration with Hg2+ ion in various concentration of 10~200 uM, we found that the probe shows a marked color change from colorless to pink, enabling naked-eye detection toward mercury ion. In addition, in the presence of Hg2+ ion, the probe gave rise to change from non-florescence to strong orange fluorescence (Off-On) with a good linearity of R2=0.97. This preliminary results demonstrate that the fluorescent chemosensor we herein introduced can open a new strategy for marked selective and sensitive detection of mercury ions in contaminated soil containing various metal ions.

活性炭에 依한 Hg(II) 이온의 吸着에 관한 조사연구(1) (A Study on the Adsorption of Hg(II) Ion by Activated Carbon(1))

  • Lee, Hyun;Lee, Jong-Hang;Yun, O. Sub
    • 한국환경보건학회지
    • /
    • 제14권2호
    • /
    • pp.65-71
    • /
    • 1988
  • In this study, the method of adsorption by activated carbon in the removal of Hg(II) ion in waste water was treated. The influence of kinds of activated carbon and effect of temperature and the influence of coexistent salt on adsorption rates, the influence of pH in the adsorption, equilibrium and adsorption of mercury from activated carbon were investigated. From the adsorption on activated carbon of mercury(II) ion in the presence of cyanide or thiocyanate ion was found that mercury(II) was easily adsorved onto the activated carbon in the form of complex artion such as Hg(CN)$_4^{2-}$, Hg(SCN)$_4^{2-}$ respectively. ZnCl$_2$ activation method had a higher adsorptive ability than steam activation method in adsorption of Hg on activated carbon. Activated carbon adsorbed iodide ion is very effective on adsorption of Hg.

  • PDF

The Potentiometric Performance of Mercury (II) Ion-Selective Electrode Based on Tetracycline Antibiotics

  • Baek, Jong-Gyu;Rhee Paeng, In-Sook
    • 전기화학회지
    • /
    • 제11권1호
    • /
    • pp.59-63
    • /
    • 2008
  • Poly (vinylchloride) (PVC) membrane electrodes based on neutral carrier, tetracycline was prepared as an active sensor for Hg(II) ion, and tested in different contents of the potassium tetrakis (4-chlorophenyl) borate (KTpClPB) as lipophilic salt. Bis (2-ethylhexyl) sebacate (DOS), bis(l-butylpentyl) adipate (BBPA), 2-nitrophenyl octyl ether (NPOE) and dibutyl phthalate (DBP) were used as diverse plasticizing solvent mediators. This electrode shows excellent potentiometric response characteristics and display good linearity with log $[Hg^{+2}]$ versus EMF response, over a range of concentrations between $10^{-7}$ and $10^{-3}M$. With 30.8mV/decade Nernstian slope, the detection limit was $6.9{\times}10^{-9}M$ and the response time was less than 20s. The proposed electrode yields very good selectivity for mercury (II) ion over many cations such as alkali, alkaline earth, transition and heavy metal ions. And it shows a very stable potential values in a wide pH range. This reliable electrode prepared was kept at least a month without considerable alteration in their response to Hg (II) ion.

A highly effective route for removal of Hg2+ from the waste water using 3-nitrobenzelidenemalononitrile as a modifier of Fe3O4@SiO2 nanoparticles

  • Mosleh Mehryar;Ghasem Marandi
    • Advances in nano research
    • /
    • 제16권1호
    • /
    • pp.1-9
    • /
    • 2024
  • SiO2-coated magnetic nanoparticles (Fe3O4@SiO2 NPs) were modified by 3-nitrobenzelidenmalononitrile and used as green linkages for removal of Hg2+ form the wastewater. In this research, it has been attempted to refer to the harmful effects of mercury ions for living things and how to remove such ions using very easy and practical technique. This study shows that by optimizing the test conditions, the efficiency of the removal of harmful ions such as mercury from the water contaminated with these ions can be increased. Conditions such as temperature, speed of agitation, pH of solution were tested for removal of mercury ions. The advantages of this method over other methods listed in the article are the rapid and easy nanocry synthesis. The generated and modified Fe3O4@SiO2 nanoparticles were characterized by X-ray diffraction, fourier transform infrared and scanning electron microscopy spectroscopy. The results show that the synthesized magnetic nanoparticles have the excellent performance for the removal of mercury(II) ion from the waste water.

Real-Time Voltammetric Assay of Lead Ion in Biological Cell Systems

  • Ly, Suw-Young
    • Toxicological Research
    • /
    • 제25권4호
    • /
    • pp.231-235
    • /
    • 2009
  • Trace lead detection for cyclic voltammetry (CV) and square-wave (SW) stripping voltammetry was performed using mercury immobilized onto a carbon nanotube electrode (HNPE). Using the characteristics of mercury and the catalytic carbon nanotube structure, a modified technique, the $0.45{\mu}g/l$ detection limit of lead ion was attained. The developed method can be applied to pond water, fish tissue, plant tissue, and in vivo direct assay.

수은 Ion이 백서장기내 Lactic Dehydrogenase Isozyme에 미치는 영향 (Effects of Mercuric Ion on Lactic Dehydrogenase Isozyme in the Organs of Albino Rats.)

  • 이해금
    • 약학회지
    • /
    • 제19권1호
    • /
    • pp.36-46
    • /
    • 1975
  • In the rats administered mercuric chloride (1mg/kg/48 hrs i.p.), it was found that LDH$_{1}$ and LDH$_{2}$ were increased in heart, brain and kidney as well as LDH$_{5}$ increased in liver and muscle in the duration of sixteen days. After the sixteen days of administration, the LDH isozyme patterns in the above mentioned organs were found to be irregularly changed. Considerable amount of mercury accumulation in liver and kidney were found, and especially the mercury accumulation in kidney was notable.

  • PDF