• Title/Summary/Keyword: Mercury ion

Search Result 92, Processing Time 0.022 seconds

Mercury ion detection technique using KPFM (KPFM을 통한 수은이온 검출 방법)

  • Park, Chanho;Jang, Kwewhan;Lee, Sangmyung;You, Juneseok;Na, Sungsoo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.358-360
    • /
    • 2014
  • For the several decades, various nanomaterials are broadly used in industry and research. With the growth of nanotechnology, the study of nanotoxicity is being accelerated. Particularly, mercury ion is widely used in real life. Because the mercury is representative high toxic material, it is highly recommended to detect the mercury ion. In previous reported work, thymine-thymine mismatches (T-T) capture mercury ion and create very stable base pair ($T-Hg^{2+}-T$). Here, we performed the high sensitive sensing method for direct label free detection of mercury ions and DNA binding using Kelvin Probe Force Microscope (KPFM). In this method, 30 base pairs of thymine (T-30) is used for mercury specific DNA binding ($T-Hg^{2+}-T$). KPFM is able to detect the mercury ion because there is difference between bare T-30 DNA and mercury mediated DNA ($T-Hg^{2+}-T$).

  • PDF

Mercury Ion Monitoring in Mercury Plating Bath by Anodic Stripping Voltammetry

  • Park, Mijung;Yoon, Sumi;Shin, Woonsup
    • Journal of Electrochemical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.241-244
    • /
    • 2016
  • Anodic stripping voltammetry (ASV) is successfully applied in mM level detection of mercury ion in an electroplating bath which is currently used in preparing a cathodic electrolyzer. Glassy carbon electrode is used for the detection and the optimum condition obtained is 10 s deposition at −1.4 V vs. Ag/AgCl and stripping by scanning from −1.4 to +0.4 V vs Ag/AgCl at 50 mV/s. By applying the method, the mercury ion concentration in the electroplating bath could be successfully monitored during the plating.

Selective determination of mercury (II) ion in aqueous solution by chemiluminescence method (화학발광법에 의한 수용액 중의 선택적 수은(II) 이온 정량)

  • Kim, Kyung-Min;Jang, Taek-Gyun;Kim, Young-Ho;Oh, Sang-Huyb;Lee, Sang-Hak
    • Analytical Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.243-248
    • /
    • 2011
  • A selective determination method of mercury (II) ion in aqueous solution by luminol-based chemiluminescence system (luminol CL system) has been developed. Determination of metal ions such as copper (II), iron (III), chromium (III) ion in solution by the luminol CL system using its catalytic role in the reaction of luminol and hydrogen peroxide has been reported by several groups. In this study, the catalytic activity of mercury (II) ion in the reaction of luminol and hydrogen peroxide was observed by the enhanced CL intensity of the luminol CL system. Based on this phenomenon, experimental conditions of the luminol CL system were investigated and optimized to determine mercury (II) ion in aqueous solution. While mercury (II) ion in mixed sample solution containing mercury (I) and (II) ions highly enhanced the CL intensity of the luminol CL system, the mercury (I) ion could not enhanced the CL intensity. Thus selective determination of the mercury (II) ions in a mixture containing mercury (I) and (II) ions could be achieved. Each concentration of mercury (I) and (II) ions in aqueous solution can be obtained from the results of the CL method that give the concentration of only mercury (II) ion and the inductively coupled plasma (ICP) method that give the total concentration of mercury ions. On the optimized conditions, the calibration curve of mercury (II) ion was linear over the range from $1.25{\times}10^{-5}$ to $2.50{\times}10^{-3}M$ with correlation coefficient of 0.991. The detection limit of mercury (II) ion in aqueous solution was calculated to be $1.25{\times}10^{-7}M$.

Determination of Mercury Ion in Contaminated Soil by Rhodamine B Hydrazide (형광화학센서를 이용한 용출기반 토양 수은 오염조사)

  • Kim, Kyungtae;Park, Junboum
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.3
    • /
    • pp.1-5
    • /
    • 2016
  • Rhodamine B Hydrazide as a novel fluorescent and colorimetric probe exhibiting remarkably selective fluorescence enhancement toward Hg2+ ion over other 16 metal ions is herein introduced. The probe reacts with Hg2+ ion followed by its spirolactam ring-opening to give a remarkable enhancement of absorption maximum at 550 nm as well as an enhanced fluorescence intensity at 580 nm in aqueous media. Upon titration with Hg2+ ion in various concentration of 10~200 uM, we found that the probe shows a marked color change from colorless to pink, enabling naked-eye detection toward mercury ion. In addition, in the presence of Hg2+ ion, the probe gave rise to change from non-florescence to strong orange fluorescence (Off-On) with a good linearity of R2=0.97. This preliminary results demonstrate that the fluorescent chemosensor we herein introduced can open a new strategy for marked selective and sensitive detection of mercury ions in contaminated soil containing various metal ions.

A Study on the Adsorption of Hg(II) Ion by Activated Carbon(1) (活性炭에 依한 Hg(II) 이온의 吸着에 관한 조사연구(1))

  • Lee, Hyun;Lee, Jong-Hang;Yun, O. Sub
    • Journal of Environmental Health Sciences
    • /
    • v.14 no.2
    • /
    • pp.65-71
    • /
    • 1988
  • In this study, the method of adsorption by activated carbon in the removal of Hg(II) ion in waste water was treated. The influence of kinds of activated carbon and effect of temperature and the influence of coexistent salt on adsorption rates, the influence of pH in the adsorption, equilibrium and adsorption of mercury from activated carbon were investigated. From the adsorption on activated carbon of mercury(II) ion in the presence of cyanide or thiocyanate ion was found that mercury(II) was easily adsorved onto the activated carbon in the form of complex artion such as Hg(CN)$_4^{2-}$, Hg(SCN)$_4^{2-}$ respectively. ZnCl$_2$ activation method had a higher adsorptive ability than steam activation method in adsorption of Hg on activated carbon. Activated carbon adsorbed iodide ion is very effective on adsorption of Hg.

  • PDF

The Potentiometric Performance of Mercury (II) Ion-Selective Electrode Based on Tetracycline Antibiotics

  • Baek, Jong-Gyu;Rhee Paeng, In-Sook
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.1
    • /
    • pp.59-63
    • /
    • 2008
  • Poly (vinylchloride) (PVC) membrane electrodes based on neutral carrier, tetracycline was prepared as an active sensor for Hg(II) ion, and tested in different contents of the potassium tetrakis (4-chlorophenyl) borate (KTpClPB) as lipophilic salt. Bis (2-ethylhexyl) sebacate (DOS), bis(l-butylpentyl) adipate (BBPA), 2-nitrophenyl octyl ether (NPOE) and dibutyl phthalate (DBP) were used as diverse plasticizing solvent mediators. This electrode shows excellent potentiometric response characteristics and display good linearity with log $[Hg^{+2}]$ versus EMF response, over a range of concentrations between $10^{-7}$ and $10^{-3}M$. With 30.8mV/decade Nernstian slope, the detection limit was $6.9{\times}10^{-9}M$ and the response time was less than 20s. The proposed electrode yields very good selectivity for mercury (II) ion over many cations such as alkali, alkaline earth, transition and heavy metal ions. And it shows a very stable potential values in a wide pH range. This reliable electrode prepared was kept at least a month without considerable alteration in their response to Hg (II) ion.

A highly effective route for removal of Hg2+ from the waste water using 3-nitrobenzelidenemalononitrile as a modifier of Fe3O4@SiO2 nanoparticles

  • Mosleh Mehryar;Ghasem Marandi
    • Advances in nano research
    • /
    • v.16 no.1
    • /
    • pp.1-9
    • /
    • 2024
  • SiO2-coated magnetic nanoparticles (Fe3O4@SiO2 NPs) were modified by 3-nitrobenzelidenmalononitrile and used as green linkages for removal of Hg2+ form the wastewater. In this research, it has been attempted to refer to the harmful effects of mercury ions for living things and how to remove such ions using very easy and practical technique. This study shows that by optimizing the test conditions, the efficiency of the removal of harmful ions such as mercury from the water contaminated with these ions can be increased. Conditions such as temperature, speed of agitation, pH of solution were tested for removal of mercury ions. The advantages of this method over other methods listed in the article are the rapid and easy nanocry synthesis. The generated and modified Fe3O4@SiO2 nanoparticles were characterized by X-ray diffraction, fourier transform infrared and scanning electron microscopy spectroscopy. The results show that the synthesized magnetic nanoparticles have the excellent performance for the removal of mercury(II) ion from the waste water.

Real-Time Voltammetric Assay of Lead Ion in Biological Cell Systems

  • Ly, Suw-Young
    • Toxicological Research
    • /
    • v.25 no.4
    • /
    • pp.231-235
    • /
    • 2009
  • Trace lead detection for cyclic voltammetry (CV) and square-wave (SW) stripping voltammetry was performed using mercury immobilized onto a carbon nanotube electrode (HNPE). Using the characteristics of mercury and the catalytic carbon nanotube structure, a modified technique, the $0.45{\mu}g/l$ detection limit of lead ion was attained. The developed method can be applied to pond water, fish tissue, plant tissue, and in vivo direct assay.

Effects of Mercuric Ion on Lactic Dehydrogenase Isozyme in the Organs of Albino Rats. (수은 Ion이 백서장기내 Lactic Dehydrogenase Isozyme에 미치는 영향)

  • 이해금
    • YAKHAK HOEJI
    • /
    • v.19 no.1
    • /
    • pp.36-46
    • /
    • 1975
  • In the rats administered mercuric chloride (1mg/kg/48 hrs i.p.), it was found that LDH$_{1}$ and LDH$_{2}$ were increased in heart, brain and kidney as well as LDH$_{5}$ increased in liver and muscle in the duration of sixteen days. After the sixteen days of administration, the LDH isozyme patterns in the above mentioned organs were found to be irregularly changed. Considerable amount of mercury accumulation in liver and kidney were found, and especially the mercury accumulation in kidney was notable.

  • PDF

Characteristics of Mercury-resistant Bacteria Isolated from River Water (하천에서 분리한 수은 내성세균의 특성)

  • 정현미;김상종;고영희
    • Korean Journal of Microbiology
    • /
    • v.28 no.1
    • /
    • pp.76-82
    • /
    • 1990
  • In samples taken from mouth of the Nakdong River, mercury-resistant bacteria grown on the media supplemented with over 20 ppm of mercuric chlorice were below 0.3% of all aerobic heterotrophs. Among them, seven strains grown over 100 ppm of mercuric chloride were isolated and all were identified as Pseudomonas. The toxic effect of mercury on the growth of the most resistant strain N14 was influenced by the organic compounds and concentration. The growth and physiological activity to N14 strain were affected by toxic mercury in the early stage: The viable count and glucose turn over rate of N14 strain dropped to the lowest level as soon as the bacteria came into contact with mercury. During the extended lag period, however, bacteria accommodated to the stress and the viable count and glucose turnover rate increased. After the lag period, bacteria began to proliferate and their growth reached similar level to that of control. In crude extracts of N14 strain grown in nutrient browth containing. $10{\mu}M$ $HgCl_{2}$, a mercuric ion dependent oxidation of NADPH was demonstrated. Therefore the mechanism of mercury-resistance of the N14 strain involved the elimination of the mercury from growth media. In the N14 strain which a wide range of resistance to antibiotics was observed in, four multiple plasmids were detected. As a result, the supposition that N14 strain has a plasmid-encoded enzyme system may be quite within the realms of possobility.

  • PDF