• Title/Summary/Keyword: Mercury emission

Search Result 87, Processing Time 0.035 seconds

Realization of Readout Circuit Through Integrator to Average MCT Photodetector Signals of Noncontact Chemical Agent Detector (비접촉 화학작용제 검출기의 MCT 광검출기를 위한 적분기 기반의 리드아웃 회로 구현)

  • Park, Jae-Hyoun
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.115-119
    • /
    • 2022
  • A readout circuit for a mercury-cadmium-telluride (MCT)-amplified mid-wave infrared (IR) photodetector was realized and applied to noncontact chemical agent detectors based on a quantum cascade laser (QCL). The QCL emitted 250 times for each wavelength in 0.2-㎛ steps from 8 to 12 ㎛ with a frequency of 100 kHz and duty ratio of 10%. Because of the nonconstant QCL emission power during on-duty, averaging the photodetector signals is essential. Averaging can be performed in digital back-end processing through a high-speed analog-to-digital converter (ADC) or in analog front-end processing through an integrator circuit. In addition, it should be considered that the 250 IR data points should be completely transferred to a PC during each wavelength tuning period of the QCL. To average and minimize the IR data, we designed a readout circuit using the analog front-end processing method. The proposed readout circuit consisted of a switched-capacitor integrator, voltage level shifter, relatively low-speed analog-to-digital converter, and micro-control unit. We confirmed that the MCT photodetector signal according to the QCL source can be accurately read and transferred to the PC without omissions.

Determination of Heavy Metal Contents in Various Packaging Boards (지류 포장재 종류에 따른 중금속 함량 측정)

  • Kim, Jin-Woo;Seo, Joo-Hwan;Youn, Hye-Jung;Lee, Hak-Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.41 no.2
    • /
    • pp.55-63
    • /
    • 2009
  • This study was performed to evaluate the heavy metal contents in various packaging board. Domestic and foreign OCC (old corrugated containers) and old duplex boards were used as raw materials. Tests were made for the printed and unprinted parts of the sample. Heavy metal contents of old food packaging boards made from virgin pulp fibers were also evaluated. The contents of heavy metals including lead (Pb), cadmium (Cd), barium (Ba), arsenic (As), antimony (Sb), selenium (Se), and mercury (Hg) were determined using ICP-AES (Inductively Coupled Plasma - Atomic Emission Spectrometer), and CV-AAS (Cold vapor-atomic absorption spectrometer) after digesting the samples in a microwave oven. The contents of heavy metals contained in domestic packaging board were higher than those in overseas samples, and OCC showed higher contents of heavy metals than old duplex boards. Printed parts gave greater heavy metal contents than unprinted parts. Results indicate that recycling of paper and paperboard products increases the heavy metal contamination of the paper packaging products and this derives mostly from the heavy metals contained in printing inks. Recycling processes that decrease heavy metals in recycled fibers and new printing inks that contains less heavy metals should be developed to solve the problem associated with the heavy metals in packaging paper products.

Hazardous Characteristics of metals in Bottom Ash from Municipal Solid Waste Combustors(MSWC) of Korea (도시폐기물 소각로에서 발생되는 바닥재중의 금속류 유해특성에 관한 연구)

  • Chung, David;Kim, Yu-Nung;Yun, Young-Ja;Kim, Yoen-Ho
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.253-258
    • /
    • 2001
  • This is a research on hazardous characteristics and potentials of bottom ash from 9 municipal solid waste combustors(200 tons/day) of Korea by the test methods of leaching and content. The leaching method was performed by Waste Test Method of Korea. In case of the content method, mercury was determined by thermal decomposition amalgamation atomic absorption spectrometer, other 9 elemets including Pb, which were pretreated by U.S.EPA SW-846 3050B method, were determined by flame atomic absorption spectrometer(FAAS) or inductively coupled plasma atomic emission spectrometer(ICP-AES). Results of leaching test showed that Pb and Cu was main pollutants. It was interested that the distribution rate of metals' contents of each combustors was similar and the rank of concentration was Fe>Zn>Cu>Mn>Pb>Cr>As>Cd>Hg.

  • PDF

A study on the accommodation of common LED to shipboard (육상용 LED 램프의 선박 적응력에 관한 연구)

  • Jeong, Ji-Hyun;Park, Hwan-Chul;Kim, Yong-Joo;Seo, Sang-Do;Han, Seung-Jae;Kim, Min-Sok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.4
    • /
    • pp.503-508
    • /
    • 2010
  • Common LED (Light Emitting Diode) lamp has many advantages to compare with fluorescent lamp, long life and no pollution matter like the mercury. The LED lamp is a good light source especially for shipboard lighting because of its compact structure which prevents explosion and shock. Also, low maintenance cost is expected due to its longer life time in comparison with conventional lamps. The LED lamp, however, need some estimates that change of voltage and frequency, vibration, moisture on board to definite accommodation of the LED lamp to shipboard. The purpose of this study is to compare physical properties of a fluorescent lamp with one of the common LED lamp so as to analyze accommodation of common LED lamp on board. This study was carried out in two stages. First, temperature, humidity of illumination, voltage, electric current, frequency and electric power were measured by using experimental equipments. Second, a comparative analysis of consumption electric power, annual oil charge, annual CO2 emission and lamp life time, etc of the fluorescent lamp and common LED one was made. As a result of the study, the consumption electric power of fluorescent lamp was 50% higher than one of the common LED lamp. As a result of measuring life time, it was found that life time of common LED lamp was more about 3.5 fold than one of the fluorescent lamp. Considering these results, it's thought that common LED lamp is verified that energy saving is possible and using is possible as substitute for fluorescent lamp on board.

Colloidal synthesis of IR-Iuminescent HgTe quantum dots (콜로이드 합성법에 의한 HgTe 양자점의 제조와 특성 분석)

  • Song, Hyun-Woo;Cho, Kyoung-Ah;Kim, Hyun-Suk;Kim, Sang-Sig
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.31-34
    • /
    • 2002
  • HgTe quantum dots were synthesized in aqueous solution at room temperature by colloidal method. The synthesized materials were identified to be zincblende cubic structured HgTe quantum dots by X-ray diffraction and transmission electron microscopy image revealed that these quantum dots are agglomerate of a individual particle. The colloidally prepared HgTe quantum dots have the sphere-like shape with a diameter of approximately 4 nm. The optical properties of the HgTe quantum dots were investigated with photoluminescence(PL). The PL appears in the near-infrared region, which represent a dramatic shift from bulk HgTe behavior. The analytic results revealed that HgTe quantum dots have the broad size distribution, as PL emission spectrum covers the spectral region from 900 to 1400 nm. In this study, the factors affecting PL of HgTe quantum dots and particle size distributiont are described.會Ā᐀䁇?⨀젲岒Ā㰀會Ā㰀顇?⨀끩Ā㈀會Ā㈀?⨀䡪ఀĀ᐀會Ā᐀䡈?⨀Ā᐀會Ā᐀ꁈ?⨀硫ᜀĀ저會Ā저?⨀샟ගऀĀ저會Ā저偉?⨀栰岒ఀĀ저會Ā저ꡉ?⨀1岒Ā저會Ā저J?⨀惝ග؀Ā؀會Ā؀塊?⨀ග嘀Ā切會Ā切끊?⨀⣟ගĀ搀會Ā搀ࡋ?⨀큭킢Ā저會Ā저恋?⨀桮킢Ā저會Ā저롋?⨀⣅沥ࠀĀࠀ會Āࠀ၌?⨀샅沥Ā저會Ā저桌?⨀壆沥ሀĀ저會Ā저쁌?⨀o킢瀀ꀏ會Āᡍ?⨀棤좗ĀĀĀ會ĀĀ灍?⨀å좗ĀĀĀ會ĀĀ졍?⨀飥좗ĀĀĀ會ĀĀ⁎?⨀?ꆟᤀ

  • PDF

Elemental Composition of the Soils using LIBS Laser Induced Breakdown Spectroscopy

  • Muhammad Aslam Khoso;Seher Saleem;Altaf H. Nizamani;Hussain Saleem;Abdul Majid Soomro;Waseem Ahmed Bhutto;Saifullah Jamali;Nek Muhammad Shaikh
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.6
    • /
    • pp.200-206
    • /
    • 2024
  • Laser induced breakdown spectroscopy (LIBS) technique has been used for the elemental composition of the soils. In this technique, a high energy laser pulse is focused on a sample to produce plasma. From the spectroscopic analysis of such plasma plume, we have determined the different elements present in the soil. This technique is effective and rapid for the qualitative and quantitative analysis of all type of samples. In this work a Q-switched Nd: YAG laser operating with its fundamental mode (1064 nm laser wavelength), 5 nanosecond pulse width, and 10 Hz repetition rate was focused on soil samples using 10 cm quartz lens. The emission spectra of soil consist of Iron (Fe), Calcium (Ca), Titanium (Ti), Silicon (Si), Aluminum (Al), Magnesium (Mg), Manganese (Mn), Potassium (K), Nickel (Ni), Chromium (Cr), Copper (Cu), Mercury (Hg), Barium (Ba), Vanadium (V), Lead (Pb), Nitrogen (N), Scandium (Sc), Hydrogen (H), Strontium (Sr), and Lithium (Li) with different finger-prints of the transition lines. The maximum intensity of the transition lines was observed close to the surface of the sample and it was decreased along the axial direction of the plasma expansion due to the thermalization and the recombination process. We have also determined the plasma parameters such as electron temperature and the electron number density of the plasma using Boltzmann's plot method as well as the Stark broadening of the transition lines respectively. The electron temperature is estimated at 14611 °K, whereas the electron number density i.e. 4.1 × 1016 cm-3 lies close to the surface.

Heavy Metal Contents of Vegetables Available on the Markets in Seoul (서울에서 유통 중인 채소류의 중금속 함량에 관한 연구)

  • Choi, Chae-Man;Choi, Eun-Jung;Kim, Tae-Rang;Hong, Chae-Kyu;Kim, Jung-Hun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.12
    • /
    • pp.1873-1879
    • /
    • 2010
  • This study was conducted to estimate the heavy metal contents of vegetables available on the markets in Seoul area. Concentrations of mercury (Hg), lead (Pb), cadmium (Cd), arsenic (As), chrome (Cr), nickel (Ni), copper (Cu), and zinc (Zn) were measured in 300 samples using a mercury analyzer and inductively coupled plasma optical emission spectrometer (ICP-OES) after wet digestion. The average values of heavy metals in vegetables were as follows [mean (minimum~maximum), mg/kg]; Hg: 0.0005 (N.D~0.007), Pb: 0.011 (N.D~0.259), Cd: 0.012 (N.D~0.188), As: 0.002 (N.D~0.142), Cr: 0.100 (0.019~0.954), Ni: 0.093 (0.003~1.231), Cu: 1.098 (0.072~36.29), and Zn: 3.48 (0.485~21.31). The heavy metal contents of vegetables available on the markets in Seoul were almost the same as or lower than those reported in other studies. The weekly average intakes of mercury, lead and cadmium from vegetables take 0.44~7.71% of PTWI (Provisional Tolerable Weekly Intakes) that the FAO/WHO Joint Food Additive and Contaminants Committee sets for evaluation of food safety.

Characterization of New Avalanche Photodiode Arrays for Positron Emission Tomography

  • Song, Tae-Yong;Park, Yong;Chung, Yong-Hyun;Jung, Jin-Ho;Jeong, Myung-Hwan;Min, Byung-Jun;Hong, Key-Jo;Choe, Yearn-Seong;Lee, Kyung-Han
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.45-45
    • /
    • 2003
  • The aim of this study was the characterization and performance validation of new prototype avalanche photodiode (APD) arrays for positron emission tomography (PET). Two different APD array prototypes (noted A and B) developed by Radiation Monitoring Device (RMD) have been investigated. Principal characteristics of the two APD array were measured and compared. In order to characterize and evaluate the APD performance, capacitance, doping concentration, quantum efficiency, gain and dark current were measured. The doping concentration that shows the impurity distribution within an APD pixel as a function of depth was derived from the relationship between capacitance and bias voltage. Quantum efficiency was measured using a mercury vapor light source and a monochromator used to select a wavelength within the range of 300 to 700 nm. Quantum efficiency measurements were done at 500 V, for which the APD gain is equal to one. For the gain measurements, a pencil beam with 450 nm in wavelength was illuminating the center of each pixel. The APD dark currents were measured as a function of gain and bias. A linear fitting method was used to determine the value of surface and bulk leakage currents. Mean quantum efficiencies measured at 400 and 450 nm were 0.41 and 0.54, for array A, and 0.50 and 0.65 for array B. Mean gain at a bias voltage of 1700 V, was 617.6 for array A and 515.7 for type B. The values based on linear fitting were 0.08${\pm}$0.02 nA 38.40${\pm}$6.26 nA, 0.08${\pm}$0.0l nA 36.87${\pm}$5.19 nA, and 0.05${\pm}$0.00 nA, 21.80${\pm}$1.30 nA in bulk surface leakage current for array A and B respectively. Results of characterization demonstrate the importance of performance measurement validating the capability of APD array as the detector for PET imaging.

  • PDF

Heavy Metal Contents and Safety Evaluation of Commercial Salts in Seoul (서울시 유통 소금의 중금속 함량 및 안전성 평가)

  • Kim, Ae-Kyung;Cho, Sung-Ja;Kwak, Jae-Eun;Kum, Jin-Young;Kim, Il-Young;Kim, Jung-Hun;Chae, Young-Zoo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.1
    • /
    • pp.129-135
    • /
    • 2012
  • This study was to investigate the heavy metal content of 55 commercial salts in the Seoul area. There were 22 types of solar sea salt, 17 types of processed salt and 16 types of reworked salt. Looked at another way, there were 22 types of domestic salt and 33 types of salt imported from France, the U.S., Japan, Australia, New Zealand, and Argentina. The samples were measured using both a mercury analyzer and an Inductively-Coupled Plasma Optical Emission Spectrometer (ICP-OES). The average heavy metal contents for commercial salts were Pb $0.281{\pm}0.344$, Cd $0.035{\pm}0.221$, Cr $0.364{\pm}0.635$, Cu $0.182{\pm}0.313$, As $0.046{\pm}0.062$, Ni $0.155{\pm}0.247$, Al $5.753{\pm}10.746$, Co $0.028{\pm}0.211$ and Hg $0.001{\pm}0.001$ mg/kg. The leads were detected highly in solar sea salt rather than in processed salt or reworked salt. Also chrome, arsenic and nickel were found more in processed salt. There were large differences in aluminum content between imported solar sea salt and processed salt. Aluminum was highly detected in French products, showing that salt can be affected by regional differences. The weekly average intakes of Pb, Cd, Cr, Cu, and Hg from commercial salt were 1.652% (0.000~6.754), 0.372% (0.000~7.214), 3.177% (0.000~26.279), 0.008% (0.001~0.049), and 0.031% (0.000~0.094) respectively compared with Provisional Tolerable Weekly Intakes established by the Joint FAO/WHO Expert Committee for the evaluation of food safety. The content of heavy metals from commercial salts was determined to be at safe levels.

A Study on Migration of Heavy Metals from Kitchen Utensils Including Glassware, Ceramics, Enamel, Earthenware and Plastics (유리제 등 조리기구 중 중금속 이행에 관한 연구)

  • Choi, Jae-Chon;Park, Se-Jong;Goh, Hyeah;Lee, Ju Yeun;Eom, Mi Ok;Kim, Meehye
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.4
    • /
    • pp.334-339
    • /
    • 2014
  • The purpose of our study was to investigate the migration level of lead (Pb), cadmium (Cd), antimony (Sb), arsenic (As), hexavalent chromium ($Cr^{6+}$) and mercury (Hg) from cookwares into food simulants and to evaluate the safety of each heavy metals. The test articles for heavy metals were glassware, ceramics, enamel, earthenware, polypropylene and polyethylene cookwares for Pb and Cd, enamel for Sb, earthenware for As, polyethylene and polypropylene cookwares for $Cr^{6+}$ and Hg. All the article samples of 391 intended for contact with foods were purchased in domestic markets. Pb, Cd, Sb and As were analyzed by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES), $Cr^{6+}$ by UV visible spectrophotometer and Hg by mercury analyzer. The migration levels of heavy metals in all the samples were within the migration limits of Ministry of Food and Drug Safety (MFDS). As a result of safety evaluation, our results showed that the estimated daily intakes (EDI, mg/kg bw/day) were $9.12{\times}10^{-6}$ and $8.83{\times}10^{-7}$ for Pb and Cd from ceramics and $1.19{\times}10^{-5}$, $1.23{\times}10^{-5}$ and $7.52{\times}10^{-6}$ for Pb, Cd and Sb from enamel. Tolerable daily intakes (TDI, mg/kg bw/day) were established respectively as 0.0036, 0.00081, 0.0021, and 0.0006 for Pb, Cd, As and Hg by JECFA (Joint FAO/WHO Expert Committee on Food Additives), as 0.0060 for Sb by WHO (World Health Organization). When comparing with TDIs, the EDIs accounted for 0.25% and 0.11% for Pb and Cd from ceramics and 0.33%, 1.52% and 0.13% for Pb, Cd and Sb from enamel.