• 제목/요약/키워드: Membrane fouling

검색결과 651건 처리시간 0.03초

Happel Cell 모델을 이용한 막오염 지수 예측 (Prediction of Membrane Fouling Index by Using Happel Cell Model)

  • 박찬혁;김하나;홍승관
    • 상하수도학회지
    • /
    • 제19권5호
    • /
    • pp.632-638
    • /
    • 2005
  • Membrane fouling index such as Silt Density Index (SDI) and Modified Fouling Index (MFI) is an important parameter in design of the integrated RO/NF membrane processes for drinking water treatment. In this study, the effect of particle, membrane and feed water characteristics on membrane fouling index were investigated systematically. Higher fouling index values were observed when filtering suspensions with smaller particle size and higher feed particle concentration. Larger membrane resistance due to smaller pore size resulted in an increased membrane fouling index. The variations of feed water hardness and TDS concentrations did not show any impact on fouling index, suggesting that there were no significant colloidal interactions among particles and thus the porosity of particle cake layer accumulated on the membrane surface could be assumed to be 0.36 according to random packing density. Based on the experimental observations, fundamental membrane fouling index model was developed using Happel Cell. The effect of primary model parameters including particle size ($a_p$), particle concentration ($C_o$), membrane resistance ($R_m$), were accurately assessed without any fitting parameters, and the prediction of membrane fouling index such as MFI exhibited very good agreement with the experimental results.

Utilization of aerobic granulation to mitigate membrane fouling in MBRs

  • Iorhemen, Oliver T.;Hamza, Rania A.;Tay, Joo Hwa
    • Membrane and Water Treatment
    • /
    • 제8권5호
    • /
    • pp.395-409
    • /
    • 2017
  • Membrane bioreactor (MBR) is a compact and efficient wastewater treatment and reclamation technology; but, it is limited by membrane fouling. The control of membrane fouling significantly increases operational and maintenance costs. Bacteria and their byproducts - extracellular polymeric substances (EPS) - are major contributors to membrane fouling in MBRs. A recent attempt at fouling mitigation is the development of aerobic granular sludge membrane bioreactor (AGMBR) through the integration of a novel biotechnology - aerobic granulation - and MBR. This paper provides an overview on the development of AGMBR to mitigate membrane fouling caused by bacteria and EPS. In AGMBR, EPS are used up in granule formation; and, the rigid structure of granules provides a surface for bacteria to attach to rather than the membrane surface. Preliminary research on AGMBR using synthetic wastewater show remarkable membrane fouling reduction compared to conventional MBR, thus improved membrane filtration. Enhanced performance in AGMBR using actual municipal wastewater at pilot-scale has also been reported. Therefore, further research is needed to determine AGMBR optimal operational conditions to enhance granule stability in long-term operations and in full-scale applications.

오염물질의 특성이 막오염 지수에 미치는 영향 (Effect of Foulant Characteristics on Membrane Fouling Index)

  • 박찬혁;김하나;홍승관
    • 상하수도학회지
    • /
    • 제19권6호
    • /
    • pp.775-780
    • /
    • 2005
  • This study was performed to investigate the effect of foulant characteristics on Membrane fouling index such as Silt Density Index (SDI) and Modified Fouling Index (MFI). A linear relationship was found relating the fouling index (both SDI and MFI) on particle concentration, but fouling index values were nonlinearly (exponentially) with increasing organic concentration. When organic matter was the primary cause of fouling, the MFI was not accurately predicted due to internal fouling such as pore adsorption. The fouling index was determined mainly by particle characteristics when both particle and organic coexisted in the feed water. This observation was attributed to lessening of organic pore adsorption by particle cake layer formed on the membrane surface. Bench-scale actual fouling experiments demonstrated that permeate flux declines much faster with feed water containing particles than organic matters although fouling potential predicted by SDI values were identical, indicating that the accurate prediction of fouling potential requires the development of fouling index reflecting different foulant characteristics.

Fouling characteristics of humic substances on tight polysulfone-based ultrafiltration membrane

  • Ariono, Danu;Aryanti, Putu T.P.;Wardani, Anita K.;Wenten, I.G.
    • Membrane and Water Treatment
    • /
    • 제9권5호
    • /
    • pp.353-361
    • /
    • 2018
  • Fouling characteristics of humic substances on tight ultrafiltration (UF) membrane have been investigated. The tight UF membrane was prepared by blending polysulfone (PSf) in N.N-dimethylacetamide (DMAc) with 25%wt of Polyethylene glycol (PEG400) and 4%wt of acetone. Fouling characteristic of the modified PSf membrane was observed during peat water filtration in different trans-membrane pressure (TMP). It was found that the acetone modified membrane provided 13% increase in TMP during five hours of peat water filtration, where a stable flux was reached within 150 minutes. Meanwhile, the increase of TMP from 10 psig to 30 psig resulted in a fouling resistance enhancement of 60%. Furthermore, based on the fouling analysis, fouling mechanism at the first phase of filtration was attributed to intermediate blocking while the second phase was cake formation.

Performance and characterization of PEG400 modified PVC ultrafiltration membrane

  • Aryanti, P.T.P.;Yustiana, R.;Purnama, R.E.D.;Wenten, I.G.
    • Membrane and Water Treatment
    • /
    • 제6권5호
    • /
    • pp.379-392
    • /
    • 2015
  • Polyvinyl chloride (PVC) ultrafiltration membrane was prepared by blending 12 wt.% of PVC in N, N-dimethylacetimide (DMAc) with polyethylene glycol 400 (PEG400) as an additive. The influence of PEG400 concentration on the PVC membrane morphology, permeability, fouling and rejection were investigated. Fouling and rejection of the PVC membrane were characterized by dextran T-100 filtration. The results showed that membrane water flux was increased up to $682Lm^{-2}h^{-1}$ when 28 wt.% of PEG400 was added into the PVC membrane solution. The best membrane performance with a low fouling and a high selectivity was achieved by adding 12 wt.% concentration of PEG400, which resulted in 90% rejection of dextran and 90% of flux recovery ratio. At further addition of PEG400 concentration, irreversible fouling was starting to increase. A 90% of irreversible fouling was formed in the PVC membrane when more than 22 wt.% of PEG400 is added.

RO Chemicals 종류 및 운영

  • Martinson, Tom
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1998년도 심포지움시리즈 Jan-98 역삼투용 분리막 기술 및 응용
    • /
    • pp.57-85
    • /
    • 1998
  • RO System & Membrance Support Technology Membrance Fouling -Colloidal Fouling -Scale Fouling -Biological Fouling -Chemical Fouling

  • PDF

침지형 분리막을 이용한 오수고도처리 공정의 막오염 원인물질 및 제어에 관한 연구 (A Study on Membrane Fouling Contaminants and Control in Enhanced Sewage Treatment by Submerged Membrane Bioreactor)

  • 박철휘;윤재곤
    • 상하수도학회지
    • /
    • 제18권5호
    • /
    • pp.619-627
    • /
    • 2004
  • Purposes of this study were to examine closely the extracellular polymeric substances (EPS) which was a membrane fouling contaminant, to control detected EPS by powdered activated carbon (PAC) dosage etc. and to evaluate the possibility of practical reuse facility. With high removal efficiency of general pollutants, when the PAC is added to MBR, improvement of removal efficiency of $COD_{cr}$, and color was expected and treated wastewater can be reused. It was judged that the correlation between EPS and membrane fouling was very high. Carbohydrate and DNA in the EPS were judged to be cause of membrane fouling. If EPS could be controled, not only membrane fouling would be decreased but also operation time would be extended. In experiment of powdered activated carbon (PAC), characteristics of the best PAC for membrane fouling control were the particle size of $7{\mu}m$, lodine Number of 1,050, surface area of peat of $1,150m^2/g$. In lab test, operation time of MBR by PAC dosage of 200mg/gVSS was longer than one of MBR by without PAC dosage. Because EPS, especially carbohydrate and DNA, was controled successfully by PAC, membrane fouling in MBR could be decreased.

Nitrifying membrane bioreactor에서의 막 오염 및 질산화 특성 (Characteristics of Membrane Fouling and Nitrification in Nitrifying Membrane Bioreactor)

  • 임경조;홍순호;유익근
    • 한국환경과학회지
    • /
    • 제20권9호
    • /
    • pp.1079-1085
    • /
    • 2011
  • The purpose of this study is to find the operational characteristics of nitrifier-dominated membrane bioreactor (MBR), which has been extensively studied for organic removal, especially in terms of nitrite ($NO_2$-N) build-up and membrane fouling. Membrane fouling is one of the important factor which determines the economics of MBR system. The characteristics of membrane fouling was monitored in terms of the fouling indices such as sludge volume index (SVI), the concentration of total organic carbon (TOC) and extracellular polymeric substances (EPS) in a membrane permeate or sludge extract, the absorbance of supernatant at 260 nm. Most of index values except for protein concentration in EPS had a close relation with the increase of suction pressure and SVI value. Nitrifying MBR was superior to the conventional organic-oxidizing MBR in terms of membrane fouling since the fouling index value of nitrifying MBR was lower than that of BOD-oxidizing MBR.

막 오염 저항성이 우수한 나노 소재 정밀 여과막의 특성 연구 (Characterization of the Nano-material U Membranes with Excellent Fouling Resistance)

  • 최정환;이정빈;김인철
    • 멤브레인
    • /
    • 제15권4호
    • /
    • pp.289-296
    • /
    • 2005
  • MBR 공정에서 가장 문제시되는 부분은 실제 공정상에서 막 표면에 오염이 발생하는 문제이다. 일반적으로 막 오염은 활성 슬러지들이 막 표면에 퇴적되어서 일어나며 이로 인해 심각한 투과 유량의 감소를 야기하게 된다. 본 연구에서는 막 오염 저항성이 뛰어난 나노 입자를 분리막 표면에 함침시켜 MBR 막을 제작하였으며 이 입자들은 막 표면에서 활성 슬러지들이 쉽게 달라 붙지 못하는 역할을 수행하게 된다. 즉, 뛰어난 투수량을 지닌 정밀여과막에 나노 입자를 첨가함으로서 실제 MBR 공정에서 막 오염을 저감시킴으로서 투수량을 보전할 수 있게 하였다. 이들을 이용하여 MBR 공정에서 막 오염이 휠씬 적게 일어나는 것을 확인하였으며 이를 바탕으로 현장에 적용하여 막 오염 저항성을 확인하였다.

이온교환막의 막오염 및 오염저감 (Fouling of Ion Exchange Membranes and Their Fouling Mitigation)

  • 문승현;이홍주
    • 멤브레인
    • /
    • 제12권2호
    • /
    • pp.55-66
    • /
    • 2002
  • 본 총설에서는 전기투석 공정의 운전과 설계 능력 향상을 위해 이온교환막의 막오염현상에 관한 연구를 조사하였다. 이온교환막의 막오염현상을 정량적으로 평가하기 위해 압력차를 구동력으로 하는 막공정의 막오염지수와 유사한 전기투석 막오염지수(EDMFI)를 정의하였다. 막오염현상은 무기오염원인 실리카졸과 유기 오염원인 휴믹산과 BSA를 함유한 전기 투석 실험 결과를 비교하여 연구되었다. 이 비교에서 EDMFI는 전기투석 공정의 막오염경향을 정량적인 척도로 유용하게 이용될 수 있음을 보여주었다. 새로운 오염저감 기술로 사각파 전원이 유효함이 유기 오염물을 포함한 전기투석 실험결과에서 보고되었다. 이펄스 형태의 사각파 전원은 최적주파수에서 막오염현상을 현저하게 감소시킬 수 있었다.