• 제목/요약/키워드: Membrane Contactors

검색결과 17건 처리시간 0.034초

Membrane Contactors for Water Carbonation

  • Alessandra Criscuoli;Enrico Drioli
    • 멤브레인
    • /
    • 제1권1호
    • /
    • pp.59-59
    • /
    • 1991
  • A theoretical and experimental study made in order to determine the performance of mem-brane contactors in water carbonation is presented. In particular on the basis of experimental results pre-viously obtained it has been derived an expression in which the effect of some parameters as temprera-ture water and CO₂ flow rate CO₂ pressure trans-membrane pressure on the performance of the process is taken into account. The study refers to hollow fiber membrane contactors used for the experimental tests. The main scope has been to verify if by membrane contactors it is possible to reach the same de-gree of water carbonation as by trditional methods (1-5 g/1) and to derive for the module used a cor-relation able to describe the performance of the process at several operating conditions. The high CO₂ removal observed confirms the interesting potentialties of membrane contactors also in gas streams purification.

Membrane Contactors for Water Carbonation

  • Alessandra Criscuoli;Enrico Drioli
    • Korean Membrane Journal
    • /
    • 제1권1호
    • /
    • pp.59-64
    • /
    • 1999
  • A theoretical and experimental study made in order to determine the performance of mem-brane contactors in water carbonation is presented. In particular on the basis of experimental results pre-viously obtained it has been derived an expression in which the effect of some parameters as temprera-ture water and {{{{{CO }_{2 } }}}}} flow rate {{{{{CO }_{2 } }}}}} pressure trans-membrane pressure on the performance of the process is taken into account. The study refers to hollow fiber membrane contactors used for the experimental tests. The main scope has been to verify if by membrane contactors it is possible to reach the same de-gree of water carbonation as by trditional methods (1-5 g/1) and to derive for the module used a cor-relation able to describe the performance of the process at several operating conditions. The high {{{{{CO }_{2 } } }}}} removal observed confirms the interesting potentialties of membrane contactors also in gas streams purification.

  • PDF

SO2 제거를 위한 중공사막 기-액 접촉기의 모사 및 분리막 물질 전달 계수 추정 (The Computer Simulation and Estimation of Membrane Mass Transfer Coefficients of Hollow Fiber Membrane G-L Contactors for SO2 Removal)

  • 김용국;송희열;이형근;김인원
    • Korean Chemical Engineering Research
    • /
    • 제45권1호
    • /
    • pp.81-86
    • /
    • 2007
  • 산업 시설에서 발생하는 $SO_2$를 제거하기 위해 중공사막 기-액 접촉기를 사용하고 있다. 본 연구에서는 기-액 접촉기 내의 중공사막에서의 $SO_2$ 흡수거동 대하여 수학적으로 모델링하고, 그 모델을 유한 요소 분석법을 이용하여 모사하였다. $SO_2$의 분리에 영향을 주는 변수인 기체 유량, 분리막의 물질 전달 계수 및 접촉기의 물리적 특성에 따른 $SO_2$의 분리 효율 및 물질 전달 특성을 알아보았다. 기체의 유속 변화에 따른 중공사막을 통한 $SO_2$ 제거 효율 실험값으로부터 분리막의 물질 전달 계수를 추정하였다. 또한 중공사막 설계에 도움이 되는 자료를 계산할 수 있는 방법을 제시하였다.

MEMBRANE CONTACTORS IN INTEGRATED SYSTEMS

  • Criscuoli, Alessandra;Drioli, Enrico
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1999년도 The 7th Summer Workshop of the Membrane Society of Korea
    • /
    • pp.52-54
    • /
    • 1999
  • In the present work, results of simulation studies carried out for the water carbonation process are presented and compared with experimental data obtained for the same system. Furthermore, the use of membrane contactors in integrated membrane operations is proposed and discussed as a mean to enhance the performance of processes.

  • PDF

Advanced Membrane Systems for Seawater Desalination. Kinetics of Salts Crystallization from RO Brines Promoted by Polymeric Membranes

  • Curcio, Efrem;Obaidani, Sulaiman Al;Macedonio, Francesca;Profio, Gianluca Di;Gualtieri, Silvia;Drioli, Enrico
    • 멤브레인
    • /
    • 제17권2호
    • /
    • pp.93-98
    • /
    • 2007
  • The reliability of innovative membrane contactors technology (i.e. Gas/Liquid Membrane Contactors, Membrane Distillation/Crystallization) is today increasing for seawater desalination processes, where traditional pressure-driven membrane separation units are routinely operated. Furthermore, conventional membrane operations can be integrated with membrane contactors in order to promote possible improvements in process efficiency, operational stability, environmental impact, water quality and cost. Seawater is the most abundant aqueous solution on the earth: the amount of dissolved salts covers about 3% of its composition, and six elements (Na, Mg, Ca, K, Cl, S) account for more than 90% of ionic species. Recent investigations on Membrane Distillation-Crystallization have shown the possibility to achieve significant overall water recovery factors, to limit the brine disposal problem, and to recover valuable salts (i.e. calcium sulphate, sodium chloride, magnesium sulphate) by combining this technology with conventional RO trains. In this work, the kinetics of $CaSO_4{\cdot}2H_2O,\;NaCl\;and\;MgSO_4{\cdot}7H_2O$ crystallization is experimentally investigated in order to improve the design of the membrane-based crystallization unit.

다공성 중공사막 기액 접촉기틀 이용한 $SO_2$ 제거에서 막재질과 흡수제의 영향 (Effect of Membrane Material and Absorbent Type on $SO_2$ Removal Using Microporous Hollow-fiber Membrane G-L Contactors)

  • 송희열;김인원;박현희;임춘원;조항대;이형근
    • 한국가스학회지
    • /
    • 제10권2호
    • /
    • pp.14-21
    • /
    • 2006
  • 다공성 중공사막 분리막 기액접촉기을 이용한 황산화물 제거장치를 제작하고 다양한 상용 분리막과 자체 제작한 분리막을 이용하여 황산화물 제거 성능 실험을 수행하였다. 분리막을 이용한 황산화물 제거 성능 평가 결과 대단히 우수한 제거효율을 보였다. 중공사막을 이용하여 $SO_2$를 제거할 경우에 액막 저항을 낮출 수 있는 흡수제와 첨가제의 선정, 막 재질, 막 제조조건 등이 최적의 G-L Contactor개발에 중요한 변수로 나타났다. 향후 보다 소형화되고, 경제적이며 효율이 우수한 G-L Contactor System 개발에 대한 연구를 진행할 것이다.

  • PDF

분리막 접촉기의 기술 동향 (Thends in Membrane Contactors)

  • 이규호;김민정;서봉국;박유인;이기섭
    • 멤브레인
    • /
    • 제15권3호
    • /
    • pp.187-197
    • /
    • 2005
  • 분리막 접촉기는 액체-액체, 기체-액체와 같이 두 개의 다른 상 사이에 막이 상계면 혹은 상 장벽의 역할을 수행하여 두 상간의 물질전달이 이루어지게 하는 장치이다 분리막 접촉기는 기체-액체 또는 액체-액체 간에 접촉을 통해 안정된 계면을 형성시켜줌으로써 인위적으로 물질전달속도 조절이 가능할 뿐만 아니라 접촉면적이 크고 기존 분리정제 공정의 운전 시 발생할 수 있는 유화(emulsion), 범람(flooding), 편류(channeling), 기포생성(foaming), 그리고 부하(unloading) 등과 같은 기술적 문제점을 보완할 수 있어 이에 대한 연구가 활발히 진행되고 있다. 이에 본 논문에서는 분리막 접촉기가 이용되는 공정과 분리막 접촉기에 사용되는 막의 제조방법, 국내외의 연구동향을 고찰하여 분리공정으로써의 분리막 접촉기에 관한 이해를 높이고자 한다.

Mathematical modeling of humidification process by means of hollow fiber membrane contactor

  • Marjani, Azam;Baghdadi, Ali;Ghadiri, Mehdi
    • Membrane and Water Treatment
    • /
    • 제7권4호
    • /
    • pp.297-311
    • /
    • 2016
  • Modeling and simulation of air humidification by hollow fiber membrane contactors are investigated in the current study. A computational fluid dynamic model was developed by solving the k-epsilon turbulence 2D Navier-Stokes equations as well as mass conservation equations for steady-state conditions in membrane contactors. Finite element method is used for the study of the air humidification under different operating conditions, with a focus on the humidity density, total mass transfer flux and velocity field. There has been good agreement between simulation results and experimental data obtained from literature. It is found that the enhancement of air stream decreases the outlet humidity from 0.392 to 0.340 (module 1) and from 0.467 to 0.337 (module 2). The results also indicated that there has been an increase in air velocity in the narrow space of shell side compared with air velocity wide space of shell side. Also, irregular arrangement has lower dead zones than regular arrangement which leads to higher water flux.

CO2/CH4 분리를 위한 프로필렌카보네이트/물 흡수제 특성 평가 및 막접촉기의 적용 (Evaluation of Propylenecarbonate/water Physical Absorbents and its Application in Membrane Contactors for CO2/CH4 Separation)

  • 박아름이;김성중;이평수;남승은;박유인
    • 멤브레인
    • /
    • 제26권2호
    • /
    • pp.126-134
    • /
    • 2016
  • 바이오 가스로부터 바이오 메탄을 생산하기 위해 물리흡수제 특성평가 및 $CO_2/CH_4$흡수 연구를 진행하였고, poly-propylene(PP) 중공사막 막접촉기에 적용해보았다. 물리흡수제 중 propylene carbonate (PC)는 PP 중공사막과 가장 높은 $58.3^{\circ}$ 접촉각을 보였고, 5 wt% PC를 물과 혼합할 경우 $90^{\circ}$ 이상의 접촉각이 관찰되었다. 또한 $CO_2$ 흡수실험에서 PC/물 혼합 흡수제는 물 흡수량(0.121 mmol/g) 보다 높은 0.148-0.157 mmol/g의 흡수량을 보이며, 막접촉기에 가장 적합한 물리흡수제로 선정되었다. PC/물 혼합 흡수제를 막접촉기에 적용 후 얻어진 $CO_2$ 제거율(98.0-97.8%)과 $CH_4$ 순도(98.5-98.3%)는 바이오 메탄으로서 매우 높은 가능성을 보여주었다. 하지만 PC/물 혼합 흡수제의 경우에는 물 흡수제와 비교하여 성능 변화가 매우 미비하였다. 이는 물보다 우수한 PC 흡수능과 함께 그에 따른 막접촉기 탈기 막 모듈 및 시스템 개선과 공급 유량 조절을 통해 $CH_4$ 손실 최소화 등 공정 최적화가 필요한 것으로 분석된다.