• Title/Summary/Keyword: Melting depth

Search Result 88, Processing Time 0.024 seconds

A Study on Snow Melting System for the Anti-freezing Testing Road (시험선로 결빙방지를 위한 융설시스템에 관한 연구)

  • Han, K.I.;Lee, A.H.;Cho, D.H.
    • Journal of Power System Engineering
    • /
    • v.10 no.1
    • /
    • pp.34-40
    • /
    • 2006
  • The snow melting system by electric heating wires which is adopted in this study is a part of road facilities to keep surface temperature of the road higher than freezing point of water for melting the snow accumulated on it. The system is designed to increase traffic safety and capacity. The electric heating wires are buried under paved road at a certain depth and operated automatically and manually. Design theory, amount of heating, and installation standard vary according to economic situation, weather condition, and installation place where the system applies. It is tried to figure out that the appropriate range of required heat capacity and installation depth and intervals for solving snowdrifts and freezing problems with the minimum electric power consumption. The most important factors to design the system are calculation of heating capacity depending on weather condition and depth and interval of the electric heating wires depending on air condition respectively. The study were performed under the range of the air temperatures($-2^{\circ}C,\;-5^{\circ}C,\;-8^{\circ}C$), the intervals of the electric heating wires(70mm, 100mm, 125mm), and the installation depths(50mm, 70mm, 100mm). The ready made commercial program package was used to verify the experimental results.

  • PDF

A Study on the Recycling of Aluminum Chip by Vortex Melting Method (Vortex melting법에 의한 알루미늄 chip의 재활용에 관한 연구)

  • 김정호;김경민;윤의박
    • Resources Recycling
    • /
    • v.6 no.4
    • /
    • pp.24-30
    • /
    • 1997
  • The recent trend of recycle of mold scrap is to make high quality secondary ingot which can be used as raw malerial undcr intensive control of scrap. In this study, recycle of aluminum chlp generated atter machinmg process of castings was performed by vortex melting melhod Vortex melting technique was adopted for chip mclting process. The condition far optimal vortcx depth was decided using water mndellng experiment varying the shape, location, rotating speed of stlircr and watcr levcl. Before melting, chips were preheated at room temperame, 200, 300, $ 400^{\circ}C$and then submerged in the mirldle of vortex. The lecovery rale depending on the temperature was examined. As a result vortex depth was influenccd only by shape and rotating speed of stirrer, and the hlghest recovery rate oI 97% was obta~nedw hcn the submerged chip was preheated at $300^{\circ}C.$

  • PDF

Time-dependent natural convection in a glass melting furnace (유리용융로의 시간종속 자연대류)

  • Im, Gwang-Ok;Lee, Gwan-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.7
    • /
    • pp.919-927
    • /
    • 1997
  • The main purpose of this study is to determine bifurcation as the primary instability of a glass melting furnace. Steady-state and unsteady characteristics of natural convection in the partially open cavity as appeared in a glass melting furnace is investigated by using numerical analysis. Three types of convection, such as steady laminar, unsteady periodic or unsteady quasi-periodic convection may occur according to the temperature difference between upper two isothermal surfaces along the depth of cavity in a glass melting furnace. In the temperature difference of 150-900 K between batch and free surface, the larger the temperature difference, the weaker the convection strength and unsteadiness. Since the glass viscosity is increasing exponentially in the lower temperature, the batch freezes the thermofluidic field especially below the surface of it. If the depth of cavity is 0.5 m, the bifurcation to time-dependent natural convection may occur in the range of 60-650 K. If that is 1.0 m, it may occur in the whole range of temperature difference.

Process Analysis of Melting Behaviors in Selective Laser Melting Process (선택적 레이저 용융 공정시 용융 거동에 대한 공정 분석)

  • Sung, M.Y.;Joo, B.D.;Kim, S.H.;Moon, Y.H.
    • Transactions of Materials Processing
    • /
    • v.19 no.8
    • /
    • pp.517-522
    • /
    • 2010
  • Selective laser melting (SLM) is emerged as a new manufacturing technique to directly fabricate precise parts using metallic materials. The final characteristics of a component fabricated through the SLM process are strongly dependent upon various parameters such as laser power, scan rate and pulse duration, etc. This paper, therefore, focuses on the dimensional characteristics of melted $20{\mu}m$ Fe-Cr-Ni powder by fiber laser for the selective laser melting process. With energy density decrease, the height and depth were decreased. Although the conditions are of the same energy density, the shape is different by laser power and scan rate. The shapes at various laser parameters were divided into 3 groups based on depth over height. The smooth regular shape is obtained under the conditions of $50{\mu}m$ of powder height and $15-20{\mu}s$ of pulse duration. And the laser power influenced the variation of shape more significantly than the scan rate.

Microstructure and Hardness of Surface Melting Hardened Zone of Mold Steel, SM45C using Yb:YAG Disk Laser

  • Lee, Kwang-Hyeon;Choi, Seong-Won;Yoon, Tae-Jin;Kang, Chung-Yun
    • Journal of Welding and Joining
    • /
    • v.34 no.1
    • /
    • pp.75-81
    • /
    • 2016
  • This study applied laser surface melting process using CW(Continuous wave) Yb:YAG laser and cold-work die steel SM45C and investigated microstructure and hardness. Laser beam speed, power and beam interval are fixed at 70 mm/sec, 2.8 kW and $800{\mu}m$ respectively. Depth of Hardening layer(Melting zone) was a minimum of 0.8 mm and a maximum of 1.0 mm that exceeds the limit of minimum depth 0.5 mm applying trimming die. In all weld zone, macrostructure was dendrite structure. At the dendrite boundary, Mn, Al, S and O was segregated and MnS and Al oxide existed. However, this inclusion didn't observe in the heat-affected zone (HAZ). As a result of interpreting phase transformation of binary diagram, MnS crystallizes from liquid. Also, it estimated that Al oxide forms by reacting with oxygen in the atmosphere. The hardness of the melting zone was from 650 Hv to 660 Hv regardless of the location that higher 60 Hv than the hardness of the HAZ that had maximum 600 Hv. In comparison with the size of microstructure using electron backscatter diffraction(EBSD), the size of microstructure in the melting zone was smaller than HAZ. Because it estimated that cooling rate of laser surface melting process is faster than water quenching.

A Study on Productivity Improvement in Narrow Gap TIG Welding (Narrow Gap 맞대기 TIG 용접에서 생산성 향상을 위한 연구)

  • Jun, Jae-Ho;Kim, Sung-Ryul;Cho, Sang-Myung
    • Journal of Welding and Joining
    • /
    • v.34 no.1
    • /
    • pp.68-74
    • /
    • 2016
  • Adoption of narrow gap welding shall be increased for the butt joint of thick plate, because the deformation and welding cost is reduced by decrease of cross-sectional area. However, sometimes narrow gap causes defects such as lack of fusion since it has small groove angle and narrow groove width. Therefore, GMAW, GTAW and SAW process shall be adopted to narrow gap welding with small bead hight and low deposition rate. In this study, Super-TIG welding using C-type strip was applied to semi-narrow gap butt joint in order to increase the welding productivity. High deposition rate 10kg/hr was obtained by high current 600A without undercut, humping bead and other welding defects. Measuring the mean and standard deviation of the melting depth to evaluate the developed processes, the fusion line type was determined by measuring the difference between maximum and minium melting depth. Furthermore, a model on arch fusion line and linear fusion line was suggested in order to prevent LF on groove wall in narrow gap butt welding.

Finite Element Analysis of Large-Electron-Beam Polishing-Induced Temperature Distribution (대면적 전자빔 폴리싱 공정 시 발생하는 온도 분포 유한요소해석 연구)

  • Kim, J.S.;Kim, J.S.;Kang, E.G.;Lee, S.W.;Park, H.W.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.6
    • /
    • pp.931-936
    • /
    • 2013
  • Recently, the use of large-electron-beam polishing for polishing complex metal surfaces has been proposed. In this study, the temperature induced by a large electron beam was predicted using the heat transfer theory. A finite element (FE) model of a continuous wave (CW) electron beam was constructed assuming Gaussian distribution. The temperature distribution and melting depth of an SUS304 sample were predicted by changing electron-beam polishing process parameters such as energy density and beam velocity. The results obtained using the developed FE model were compared with experimental results for verifying the melting depth prediction capability of the developed FE model.

A Study on the Surfaces Modification of Tool Steel by YAG LASER (YAG LASER에 의한공구강의 표면개질에 관한 연구)

  • 강형식
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.2
    • /
    • pp.66-71
    • /
    • 2000
  • Laser induced surface hardening of Tool steel(STC5) can be achieved either with or without surface melting. In trans-formation hardening as the surface is heated to a temperature below its melting point and is rapidly cooled solidified microstructures are usually much finer and stronger than those of the base matals. For this reason surface modification of tool steel by YAG laser irradiation has been studied as a function of processing parameters such as power density pulse width defocusing distance and molten depth. The high energy density changes and refines the microstructure of the near surface layer. In the case of beam passes martensite formed in the melt zone exhibited very high vickers hardness values. Molten depth and width depend on defocusing distance and energy of black color painting is more absorptive than other color painting.

  • PDF

A study on the optimum condition of electric snow melting and deicing system for the anti-freezing testing road (시험 선로 결빙 방지를 위한 전기 가열식 융설 및 융빙 시스템의 최적 조건에 관한 연구)

  • Han, Kyu-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.44 no.4
    • /
    • pp.362-369
    • /
    • 2008
  • The snow melting system by electric heating wires which is adopted in this research is a part of road facilities to keep surface temperature of the road higher than freezing point of water for melting the snow accumulated on it. The electric heating wires are buried under paved road at a certain depth and operated automatically and manually. Design theory, amount of heating, and installation standard vary according to economic situation, weather condition, installation place and each country applying the system. A main purpose of this study is figuring out the appropriate range of required heat capacity and installation depth and pitch for solving snowdrifts and freezing problems with minimum electric power consumption. This study was performed under the ambient air temperature($-2^{\circ}C$, $-5^{\circ}C$), the pitches of the electric heating wires(200 mm, 300 mm), heating value($250\;W/m^2$, $300\;W/m^2$, $350\;W/m^2$).

A study on the anti-freezing of light weight electric traction system testing road (경량전철 시스템 선로 결빙방지에 관한 연구)

  • Woo, Jae-Ho;Han, Kyu-Il;Kim, Jong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2256-2261
    • /
    • 2008
  • The electric snow melting and deicing system by electric heating cable which is adopted in this study is a part of road facilities to keep surface temperature of the road higher than freezing point of water for melting the snow or ice accumulated on it. The electric heating cables are buried under paved road at a certain depth and a certain pitch and operated automatically and manually. Design theory, amount of heating, and installation standard vary according to economic situation, weather condition, and installation place. A main purpose of this study is figuring out the appropriate range of required heat capacity and installation depth and pitches for solving snowdrifts and freezing problems with minimum electric power consumption. This study was performed under the ambient air temperature($-2^{\circ}C$, $-5^{\circ}C$), the pitches of the electric heating cables (200 mm, 300 mm), heating value ($250\;W/m^2$, $300\;W/m^2$, $350\;W/m^2$).

  • PDF