• Title/Summary/Keyword: Megapixel

Search Result 18, Processing Time 0.023 seconds

Distortion Calibration and Image Analysis of Megapixel Ultrawide-angle Lens (메가픽셀급 초광각 렌즈의 왜곡영상 보정과 화질분석)

  • Kang, Min-Goo;Lee, Jae-Son;Lee, Ou-Seob
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.3
    • /
    • pp.597-602
    • /
    • 2013
  • In this paper, the lens module of mega pixel type was designed for barrel distortion calibration due to the barrel distortion of ultra wide angle. And the performance of this camera module was improved with the images from wide dynamic range 2 megapixel CMOS image sensor.

Development of 360° Omnidirectional IP Camera with High Resolution of 12Million Pixels (1200만 화소의 고해상도 360° 전방위 IP 카메라 개발)

  • Lee, Hee-Yeol;Lee, Sun-Gu;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.21 no.3
    • /
    • pp.268-271
    • /
    • 2017
  • In this paper, we propose the development of high resolution $360^{\circ}$ omnidirectional IP camera with 12 million pixels. The proposed 12-megapixel high-resolution $360^{\circ}$ omnidirectional IP camera consists of a lens unit with $360^{\circ}$ omnidirectional viewing angle and a 12-megapixel high-resolution IP camera unit. The lens section of $360^{\circ}$ omnidirectional viewing angle adopts the isochronous lens design method and the catadioptric facet production method to obtain the image without peripheral distortion which is inevitably generated in the fisheye lens. The 12 megapixel high-resolution IP camera unit consists of a CMOS sensor & ISP unit, a DSP unit, and an I / O unit, and converts the image input to the camera into a digital image to perform image distortion correction, image correction and image compression And then transmits it to the NVR (Network Video Recorder). In order to evaluate the performance of the proposed 12-megapixel high-resolution $360^{\circ}$ omnidirectional IP camera, 12.3 million pixel image efficiency, $360^{\circ}$ omnidirectional lens angle of view, and electromagnetic certification standard were measured.

The Study of Gigapixel Camera Technology and the Stunning High-Resolution Gigapixel Image Created by Utilizing a Robotic Panoramic Head and an Image-Stitching Technique (로봇파노라마헤드와 스티칭 기법을 활용한 기가픽셀 이미지의 생성과 기가픽셀카메라 기술)

  • Choi, Yeon Chan;Moon, Hee Jun;Kim, Dong Young;Ryu, Jae Yun;Shin, Ye Rang;Rim, Cheon-Seog
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.1
    • /
    • pp.44-53
    • /
    • 2015
  • Since the technology of current image sensors is limited to the megapixel class, it is necessary to use an image-stitching technique to create a gigapixel image from hundreds or thousands of photos taken by a megapixel image sensor. In this paper, we investigate the entire process of gigapixel camera technology employing a robotic panoramic head plus a stitching technique, and analyze the gigapixel camera technologies of Duke University and BAE Systems from the viewpoint of optical design structure. Hopefully this knowledge will lead to a new optical structure for a gigapixel camera. Meanwhile, we also perceive the need for additional image processing to reduce the noise of photos with a background of fog and mist, taken far from the camera lens.

Molding and Optical Evaluation of Aspheric Glass Lenses for Camera Phone Module (카메라폰 모듈용 비구면 Glass렌즈의 성형 및 광학특성 평가)

  • Kim, Hye-Jeong;Cha, Du-Hwan;Kim, Jeong-Ho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.12 no.3
    • /
    • pp.124-131
    • /
    • 2007
  • Aspheric glass lenses was fabricated by glass molding press(GMP), which is a plano-aspheric convox shape and intended for use as an optical design of 3 megapixel and 2.5 magnifications zoom in a camera phone module. Transcription ratio of form accuracy (PV) as well as resolution properties was measured for evaluation the molded lens. Form accuracy (PV) of the mold surface was $0.127\;{\mu}m$ in an aspheric and $0.168\;{\mu}m$ in a plano, in case of the molded lens it shows $0.205\;{\mu}m$ and $0.223\;{\mu}m$, respectively. Resolution of the molded lens was measured as a MTF[Contrast]. The molded lens shows contrast of 32.9% at 80 1p/mm and the value is similar with contrast of 33% obtained simulation.

  • PDF

Suftla Flexible Active-Matrix Electrophoretic Displays

  • Miyasaka, Mitsutoshi;Nebashi, Satoshi;Shimoda, Tatsuya
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.466-469
    • /
    • 2006
  • We have developed the world's thinnest flexible electrophoretic displays (EPDs). The thin-film displays are 95 ..m thick, which is nearly the same thickness as a standard sheet of paper. Weighing 0.44g including external connection cables, these displays are also probably the world's lightest. We have also developed 7.1-inch-diagonal(paperback-sized) high-resolution flexible EPDs. The displays are large enough to be used as practical e-paper. More than 7 million transistors work correctly on plastic, enabling us to see 3-megapixel images. These flexible displays include active-matrix TFT devices that are fabricated using Suftla transfer technology. Suftla technology demonstrates the potential to achieve thin, flexible displays that will be used as an e-paper in the near future.

  • PDF

Three-dimensional Flow Structure inside a Plastic Microfluidic Element (미소유체요소 내부유동의 3차원 측정 및 수치해석)

  • Lee Inwon;An Kwang Hyup;Nam Young Sok;Lee In-seop
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.419-422
    • /
    • 2002
  • A three-dimensional inlet flow structure inside a microfluidic element has been investigated using a micro-PIV(particle image velocimetry) measurement as well as a numerical analysis. The present study employs a state-of-art micro-PIV system which consists of epi-fluorescence microscope, 620nm diameter fluorescent seed particles and an 8-bit megapixel CCD camera. For the numerical analysis, a commercial software CFD-ACE+(V6.6) was employed for comparison with experimental data. Fixed pressure boundary condition and a 39900 structured grid system was used for numerical analysis. Velocity vector fields with a resolution of $6.7{\times}6.7{\mu}m$ has been obtained, and the attention has been paid on the effect of varying measurement conditions of particle diameter and particle concentration on the resulting PIV results. In this study, the microfluidic elements were fabricated on plastic chips by means of MEMS processes and a subsequent melding process.

  • PDF

PIV measurements of a microfluidic elements fabricated in a plastic chip (플라스틱 미소유체요소 내부유동의 PIV 측정)

  • Lee, In-Won;Choi, Jay-Ho;Lee, In-Seop
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.400-404
    • /
    • 2001
  • A micro-PIV(particle image velocimetry) measurement has been conducted to investigate flow fields in such microfluidic devices as microchannels and micronozzle. The present study employs a state-of-art micro-PIV system which consists of epi-fluorescence microscope, 620nm diameter fluorescent seed particles and an 8-bit megapixel CCD camera. Velocity vector fields with a resolution of $6.7\times6.7{\mu}m$ has been obtained, and the attention has been paid on the effect of varying measurement conditions of particle diameter and particle concentration on the resulting PIV results. In this study, the microfluidic elements were fabricated on plastic chips by means of MEMS processes and a subsequent molding process. Flow fields in a variety of microchannels as well as micronozzle have been investigated.

  • PDF

Measurements of a microchannel flow using micro-PIV

  • Lee Inwon;Choi Jayho;Lee In-Seop
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.44-52
    • /
    • 2001
  • A micro-PIV(particle image velocimetry) measurement has been conducted to investigate flow fields in such microfluidic devices as microchannels and micronozzle. The present study employs a state-of-art micro-PIV system which consists of epi-fluorescence microscope, 620nm diameter fluorescent seed particles and an 8-bit megapixel CCD camera. Velocity vector fields with a resolution of $6.8\;\times\;6.8{\mu}m$ has been obtained, and the attention has been paid on the effect of varying measurement conditions of particle diameter and particle concentration on the resulting PIV results. In this study, the microfluidic elements were fabricated on plastic chips by means of MEMS processes and a subsequent molding process. Flow fields in a variety of microchannels as well as micronozzle have been investigated.

  • PDF

A Study on Influence of PV and Ra with Re-Ir Coating of WC Core Surface for Glass Molding Lens (성형용 초경합금(WC) 코어면의 Re-Ir 코팅이 형상정도와 표면조도에 미치는 영향에 관한 연구)

  • Kim, Hyun-Uk;Kim, Sang-Suk;Kim, Hye-Jeong;Kim, Jeong-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.9
    • /
    • pp.808-811
    • /
    • 2007
  • Aspheric glass lens have recently been used in camera phone module because they are more effective than spherical ones. In this paper, the grinding condition of the tungsten carbide molding core has been found after applying DOE to the development of the aspheric glass lens for the 3 Megapixel and 2.5x camera-phone module. Also, the ultra precision grinding process was investigated under this condition by experiment. Re-Ir coating was applied on the ground surface of the tungsten carbide molding core. The influence of Re-Ir coating on the form accuracy and surface roughness of molding core was compared and evaluated. The form accuracy and surface roughness of the molding core were improved by application of Re-Ir coating on the surface of the tungsten carbide molding core.