• Title/Summary/Keyword: Medical ultrasound system

Search Result 160, Processing Time 0.024 seconds

의무 기록용 워크스테이션 개발에 관한 연구

  • Kim, Won-Gi;Kim, Nam-Hyeon;Huh, Jae-Man
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.277-282
    • /
    • 1990
  • A workstation for archiving and communication of medical records is developed for clinical use in hospital. In this system, handwritten diagnostic reports, medical recording papers such as ECG and EEG etc., and ultrasound images are stored in optical disks instead of papers. This system improves medical service owing to speedy diagnosis by fast finding the patient's medical chart, and curtails the cost of archiving medical charts economically. If this system can be combined with already developed MPACS, then integrated medical image di- agnosis will be possible.

  • PDF

Feasibility for Ultrasound Pad Material for the Evaluation Axillary Region of Automated Breast Ultrasound Equipment (자동유방초음파 장비의 액와부 평가를 위한 초음파 패드 물질의 타당성)

  • Seo, Eun-Hee;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.231-240
    • /
    • 2018
  • Automated breast ultrasound (ABUS) equipment is a new innovative technique for 3D automatic breast scanning, but limited for the examination in the concave axillary region. The purpose of this study was to determine feasible candidate materials for the ultrasonic wave propagation media in ABUS, enabling the evaluation of the axillary region. Ultrasonography was performed using an ABUS system ($Invenia^{TM}ABUS$, GE, USA) on the ultrasound-specific phantom (UC-551M-0.5, ATS Laboratories, USA) covered by different candidate materials. The validity of feasible candidate materials was evaluated by image quality. Three independent radiological technologists, with more than 10 years of experience, visually assessed on the images. The inter-observer agreements according to the candidate materials were tested using Cronbach's alpha. Unenveloped solidified carrageenan can be a feasible material for the use of ABUS with excellent test reliability. Therefore, the coverage of the axillary region with carrageenan may be effective for ABUS which was originally developed for the convex anatomic structure as female breast.

A Review of the Clinical Use of Ultrasound in Korean Traditional Medicine

  • Kim, Seok Hee;Yook, Tae Han;Song, Beom Yong;Choi, Yoo Min;Shin, Jin Hyeon;Shin, Hye Jeong;Lee, Sanghun;Jeon, Young Ju;Kim, Jong Uk
    • Journal of Acupuncture Research
    • /
    • v.36 no.4
    • /
    • pp.204-210
    • /
    • 2019
  • This study was performed to evaluate research studies utilizing ultrasound diagnostic units, the practitioners who performed the ultrasound assessments, and how they had been used primarily in tandem with the Korean Medicine Advanced Searching Integrated System. This study identified 46 studies following a literature search, and discovered that a Korean medicine doctor led the ultrasonography in 13 studies, a medical technician was responsible in 6 studies, a roentgenologist carried it out in 5, and 19 of the studies did not specify who had conducted it. Ultrasonography had been actively used in the course of the clinical practice of Korean medicine, and it may serve as a useful and reliable diagnostic tool for evaluating the effectiveness of Korean medicine. The results of this study will help to promote more ultrasound studies in the future.

A Study on the Stationary Canceler in the Ultrasonic Pulse Doppler System (초음파 펄스 도플러 시스템의 Stationary Conceler에 대한 연구)

  • 김영길
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.1
    • /
    • pp.47-54
    • /
    • 1985
  • In this paper, clutter in ultrasound pulsed Doppler system is analyzed mathematically. And stationary canceler which reduce the clutter is designed. The operating characteristics of the stationary canceler is investigated in body (in vivo) by audio signal and spectrum analyzer.

  • PDF

Suppression of side lobe and grating lobe in ultrasound medical imaging system (의료용 초음파 영상 시스템에서 부엽과 격자엽의 억제)

  • Jeong, Mok Kun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.525-533
    • /
    • 2022
  • We propose an effective method for suppressing both side and grating lobes by applying 2-dimensional Fourier Transform to the received channel data during the receive focusing process of an ultrasound imaging system. When the signal from the image point is focused, the channel signals have the same DC value across the channels. However, even after echoes from outside an imaging point are focused, they are manifested as having different spatial frequencies depending on their incident angles. Therefore, after the receive focusing delay time is applied, 2-D Fourier Transform is performed on the time-channel data to separate the DC component and other frequency components in the spectral domain, and the weighting value is defined using the ratio of the two values. The side lobe and grating lobe were suppressed by multiplying the ultrasound image by a weighting value. Ultrasound images with a frequency of 5 MHz were simulated in a 64-channel linear array. The grating lobe appearing in the ultrasound image was completely removed by applying the proposed method. In addition, the side lobe was reduced and the lateral resolution was greatly increased. Results of computer simulation on a human organ mimicking image show that the proposed method can aid in better lesion diagnosis by increasing the image contrast.

Development of Ultrasound Phantom for Volume Calibration (부피 측정을 위한 초음파 팬텀 개발)

  • Kim, Hye-Young;Lee, Ji-Hae;Lee, Kyung-Ja;Suh, Hyun-Suk;Lee, Re-Na
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.227-230
    • /
    • 2008
  • The purpose of this study was to design and construct an ultrasound phantom for volume calibration and evaluate the volume measurement accuracy of a 2 dimensional ultrasonic system. Ultrasound phantom was designed, constructed and tested. The phantom consisted of a background material and a target. The background was made by mixing agarose gel with water. A target, made with an elastic material, was filled with water to vary its volume and shape and inserted into background material. To evaluate accuracy of a 2 dimensional ultrasonic system (128XP, ACUSON), three different shapes of targets (a sphere, 2 ellipsoids and a triangular prism) were constructed. In case of ellipsoid shape, two targets, one with same size length and width (ellipsoid 1) and another with the length 2 times longer than width (ellipsoid 2) were examined. The target volumes of each shape were varied from 94cc to 450cc and measurement accuracy was examined. The volume difference between the real and measured target of the sphere shape ranged between 6.7 and 11%. For the ellipsoid targets, the differences ranged from 9.2 to 10.5% with ellipsoid 1 and 25.7% with ellipsoid 2. The volume difference of the triangular prism target ranged between 20.8 and 35%. An easy and simple method of constructing an ultrasound phantom was introduced and it was possible to check the volume measurement accuracy of an ultrasound system.

  • PDF

A Scope of Work of Radiological Technologists for Ultrasound Examinations (초음파검사에 대한 방사선사 업무범위의 법적 고찰)

  • Lim, Chang Seon;Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.481-490
    • /
    • 2021
  • There is no qualification system for sonographers in Korea. But the MEDICAL SERVICE TECHNOLOGISTS, ETC. ACT stipulates that radiological technologists can handle ultrasound equipment. However, there is controversy about the scope of the work allowed for radiological technologists to perform ultrasound examinations. Accordingly, the authoritative interpretation of the Ministry of Health and Welfare of Korea, the adjudication of administrative judgment, and the judgment of the courts were analyzed. As a result, the authoritative interpretation expresses that when a radiological technologist performs an ultrasound examination, a diagnosis and specific guidance should be made in real time while the doctor simultaneously watches the radiological technologist's images. In the adjudication of administrative judgment, it was decided that the handling of ultrasound-related equipment was the work of the radiological technologist. The court ruled that it was illegal for a radiological technologist to make a medical judgment on ultrasound examination. In the United States, Canada, etc., the sonographer independently conducts ultrasound examination according to the doctor's prescription, prepares a summary of what they saw and this is passed on to the doctor. Therefore, in Korea, there is a need for institutional improvement so that radiological technologists can perform ultrasound examinations according to doctors' prescriptions without real-time guidance.

Breast Ultrasound Microvascular Imaging and Radiogenomics

  • Ah Young Park;Bo Kyoung Seo;Mi-Ryung Han
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.677-687
    • /
    • 2021
  • Microvascular ultrasound (US) techniques are advanced Doppler techniques that provide high sensitivity and spatial resolution for detailed visualization of low-flow vessels. Microvascular US imaging can be applied to breast lesion evaluation with or without US contrast agents. Microvascular US imaging without a contrast agent uses a sophisticated wall filtering system to selectively obtain low-flow Doppler signals from overlapped artifacts. Microvascular US imaging with second-generation contrast agents amplifies flow signals and makes them last longer, which facilitates hemodynamic evaluation of breast lesions. In this review article, we will introduce various microvascular US techniques, explain their clinical applications in breast cancer diagnosis and radiologic-histopathologic correlation, and provide a summary of a recent radiogenomic study using microvascular US.

Development of an image processing system to detect automatically intimal and adventitial contours from intravascular ultrasound images (관상동맥 혈관내부 초음파 영상에서 내벽 및 외벽 윤곽선 자동추출을 위한 영상처리 알고리즘 개발)

  • Kim, H.S.;Dove, E.L.;Chandran, K.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.05
    • /
    • pp.27-31
    • /
    • 1994
  • Intravascular ultrasound images of coranary artery contain very important informations on heart disease. The intimal contours on the image show informations and data to examine intravascular problems of patients. A new computation algorithm to detect the intimal and adventitial contours from the intravascular images was developed. An Image processing on gray level image was used. It uses arrays of pixels in each radial lines on the images. A "Robert" filter was adopted at first step for one dimensional image processing. Some other calculation techniques were developed to inclose the accuracy of automatically detected contours. The standard contour data to compare with automatically detected contour data were obtained through manually tracing by experienced cardiological medical doctors. The result of the new algorithm shows high accuracy of 80 % matching with the standard contour data.

  • PDF

Development of Ultrasound B-scanner(I)-System and Analog Part- (초음파 B스캔너의 개발(I) -시스템 및 아나로그부분-)

  • 김진하;신동희
    • Journal of Biomedical Engineering Research
    • /
    • v.5 no.1
    • /
    • pp.77-84
    • /
    • 1984
  • A prototype of a linear real-time ultrasound B-scanner has been developed which has an axial resolution of 1-2mm and lateral resolution of 2-3mm. In the actual hardware and software implementations of the B-scanner, the following features were emphasized; (1) a dynamic focusing to improve resolution; (2) signal processing to obtain low noise image; (3) various functions for the user's convenience' (4) simplification of the system by an extensive use of recently developed LSI's; (5) development of a prototype at the level of a commercial product. This paper reports the experimental results of the overall system and the design approach of the analog part. The work on the digital part of the B-scanner is reported in part (II) seperately.

  • PDF