• 제목/요약/키워드: Medical technologists

검색결과 238건 처리시간 0.025초

병리추가조직검사 정보전달을 위한 업무프로세스 연구 (Study Focused on Task Process regarding Effective Information Transfer of Ancillary Tests in Diagnostic Pathology)

  • 고재남;박윤익;정진경;안상호;김재호;신화정;현지숙;김경호
    • 한국의료질향상학회지
    • /
    • 제22권2호
    • /
    • pp.95-108
    • /
    • 2016
  • Purpose: Ancillary tests such as immunohistochemistry or molecular testing for pathologic diagnosis are performed using ready-made tissue blocks for a histological examination. Various methods and processes during ancillary testing cause some of issues, particularly in the time required and the results reporting scheme. Methods: To solve these issues, we constructed real-time management software. When a pathologist or a clinician had ancillary tests examined using this software by selecting the codes of the needed ancillary tests on site and the system assigned the tests to each laboratory. Then, pathology technologists checked the referred tests and performed the examination. In clinical departments, serial number of each ancillary test can be matched the original pathologic ID. In the department of pathology, numbers of tissue blocks that needed additional tests could be indicated and detected using one-click detection system when a clinician referred the test. Results: Using this system resulted in simplifying the referral procedures from nine-steps to three-steps in each clinical department and from seven-steps to two-steps in department of pathology. Errors that happened on the paper-based request system were also reduced. Furthermore, the time required was saved by seven hours in pathologic laboratory on average. Mean durations from requesting to reporting of the ancillary test was reduced by three days for specimens of health promotion center. Conclusion: Construction of an effective information transfer system may be helpful for shortening the time required, reducing errors, and checking processing information of the tests in real time.

보수교육에 대한 의원방사선사의 만족도와 문제점 분석 (Analysis of Satisfaction and Problems of Clinic Radiological Technologist on the Supplementary Education)

  • 정봉재;박준홍;송재흥;노시철
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.861-868
    • /
    • 2018
  • 본 연구는 의원에 근무하는 방사선사의 보수교육에 관한 연구로 보수교육에 대한 만족도와 문제점을 분석하여 보수교육에서 개선하여야 할 사항을 연구하기 위해 실시하였다. 연구에 사용한 도구는 설문지로 2016년 11월 01일부터 2017년 04월30일까지 경남 창원에 소재하는 의원에 근무하는 방사선사를 대상으로 교육참석 및 방문을 통한 조사로 이루어 졌으며, 설문지 총150부를 배부하여 연구에 적합한 106부를 SPSS 18.0 통계 프로그램을 이용하여 분석하였다. 인구사회학적 특성으로는 연령, 성별, 근무경력, 학력, 근무부서로 하였으며, 보수교육에 대한 만족요인으로는 제도, 주제, 도움, 강사선택의 적절성, 전문성 등, 총 21가지 요인으로 하였으며, 보수교육의 문제점으로는 장소, 교통편, 다양성, 행정처리, 홍보, 방법 등, 총18가지 요인으로 분석하였다. 보수교육에 대한 만족도 (3.02점)와 보수교육에 대한 문제점(3.18점)은 보통수준으로 보수교육에 대한 문제점이 조금 높게 분석되었다. 보수교육은 보건의료인이면 누구나 이수해야 하는 교육이며, 보수교육 이수 시간으로 3년마다 면허 재 신고를 해야 하는 주요한 교육이다. 다양한 의료기관에 근무하는 방사선사를 대상으로 하는 보수교육은 의원에 근무하는 방사선사의 교육수준에 부합하지 못하다는 의견이 많았다. 그러므로 의원방사선사의 보수교육에 대한 만족도를 높이기 위한 방안으로 보수교육에 대한 다양한 의견과 개선사항을 현실성 있는 교육 프로그램으로 반영하여, 교육의 질적 향상을 통한 보수교육에 대한 만족도를 높여야 할 것이다.

진단용 방사선 관련 업무 종사자의 피폭관리에 관한 연구 (A Study on the Management of Exposure of Workers and Assistants Related to Diagnostic Radiation)

  • 임창선
    • 의료법학
    • /
    • 제22권3호
    • /
    • pp.97-124
    • /
    • 2021
  • 의료기관에는 진단용 방사선 발생장치를 취급하는 방사선사, 의사, 치과의사, 치과위생사 등 방사선 관계 종사자가 있다. 그리고 간호사, 간호조무사 등 방사선진료를 보조하거나 방사선 검사실로 환자이송 등을 하는 업무 보조자들이 있다. 방사선 관계 종사자는「의료법」 등에 의해 방사선 피폭관리가 이루어지고 있으나 방사선 진료업무 보조자 등은 이에 대한 법적 근거가 없는 실정이다. 또한 진단용 방사선 피폭관리는 의료법령에 의해 규율되고 있고, 치료용 방사선과 핵의학검사에 의한 방사선 피폭관리는「원자력안전법」의 규율을 받고 있다. 이에 진단용 방사선에 의한 피폭관리를 개선하기 위하여「의료법」 상 진단용 방사선 피폭관리에 관한 규정과「원자력안전법」 상 관련 규정들을 비교·검토하여 보았다. 그 결과로 얻은 주요 내용은 다음과 같다. 첫째, 진단용 방사선에 의한 피폭관리 대상으로 방사선 관계 종사자 외에 방사선 피폭 우려가 있는 간호사, 간호조무사, 임상실습 학생 등을 포함시켜 입법적으로 해결할 필요가 있다. 둘째,「원자력안전법」에서처럼 진단용 방사선 관계 종사자가 임신이 확인된 경우에는 피폭선량 한도를 명문으로 규정해야 한다. 셋째,「진단용 방사선 발생장치의 안전관리에 관한 규칙」의 개인피폭선량계의 종류에 관한 규정을 현실에 맞게 개정할 필요가 있다. 넷째, 방사선 관계 종사자, 방사선작업종사자와 수시출입자에 대한 건강진단의 검사항목은 동일해야 할 것으로 보인다. 다섯째, 의료기관에서 진단용 방사선뿐만 아니라 치료용 방사선과 핵의학을 포함한 의료용 방사선 전체를 하나의 법체계에서 통일하여 규율하는 것이 필요하다고 본다.

진단용 방사선안전관리 현황에 관한 연구 (A Study on Enforcement Effects of Radiation Safety Control Regulations for Diagnostic X-ray Equipments)

  • 성모일;박명환;권덕문;이준일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권1호
    • /
    • pp.73-78
    • /
    • 1999
  • The purposes of this study are to analyze the realities after enforcements of safety control regulations for diagnostic X-ray equipments and to suggest means for an improvement of low radiation safety control. A questionnaire survey for medical radiologic technologists was carried out to determine enforcement effects of the safety control regulations. The results of analysis from the survey are as follows. That is, most of the respondents realized the importance of the radiation safety control system, but about a half of them revealed that the regulations were not well observed in accordance with their purposes. Only 43.9% of the respondents took an active part in quality control and safety control of radiation. And respondents responsibility, sex, age, and knowledge for safety control were important indicators for observations of the regulations. Trainings for the safety control regulations are needed to ensure safety control and proper usage of diagnostic X-ray equipments. And management of organizations using diagnostic X-ray equipments have to understand and stress the importance of radiation safety control system.

  • PDF

자동유방초음파 장비의 액와부 평가를 위한 초음파 패드 물질의 타당성 (Feasibility for Ultrasound Pad Material for the Evaluation Axillary Region of Automated Breast Ultrasound Equipment)

  • 서은희;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권3호
    • /
    • pp.231-240
    • /
    • 2018
  • Automated breast ultrasound (ABUS) equipment is a new innovative technique for 3D automatic breast scanning, but limited for the examination in the concave axillary region. The purpose of this study was to determine feasible candidate materials for the ultrasonic wave propagation media in ABUS, enabling the evaluation of the axillary region. Ultrasonography was performed using an ABUS system ($Invenia^{TM}ABUS$, GE, USA) on the ultrasound-specific phantom (UC-551M-0.5, ATS Laboratories, USA) covered by different candidate materials. The validity of feasible candidate materials was evaluated by image quality. Three independent radiological technologists, with more than 10 years of experience, visually assessed on the images. The inter-observer agreements according to the candidate materials were tested using Cronbach's alpha. Unenveloped solidified carrageenan can be a feasible material for the use of ABUS with excellent test reliability. Therefore, the coverage of the axillary region with carrageenan may be effective for ABUS which was originally developed for the convex anatomic structure as female breast.

방사선사의 직무만족도와 이직의도와의 관계 (A Study on Relationship between Radiologists' Job Satisfaction and Intention of Separation)

  • 여진동;고인호
    • 보건의료산업학회지
    • /
    • 제4권1호
    • /
    • pp.111-123
    • /
    • 2010
  • The purpose of this study is to examine relations between the job satisfaction and separation intent of radiologists from secondary medical institutes, providing basic information needed to earlier prevent radiologists' separation, improve their quality and effectively manage them. 1. The subjects' job satisfaction was 2.32 points in mean score, which was below the average. 2. Concerning difference in job satisfaction among the subjects in accordance with their demographic characteristics, it was found that radiologists are significantly different among them in job satisfaction according to their age and position. 3. The surveyed radiologists' intent of separation was 2.89 points in mean score, which was not significantly high. 4. Concerning difference in the intent of separation among the participants in accordance with their demographic characteristics, it was found that radiologists are significantly different among them in the intent of separation according to their age, marital status, position and average monthly income. 5. There were significant correlations between the subjects' job satisfaction and intent of separation. In other words, the higher radiologists are in job satisfaction, the lower they are in the intent of separation.

ALVIM Phantom을 이용한 화질관리 (Image Quality Management Using ALVIM Phantom)

  • 임득춘;동경래;박용순;김창복;류영환
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.63-68
    • /
    • 2009
  • Among various physical or subjective assessments of the quality of X-ray images, physical assessments can be quantitative but they are eventually judged by the view of observers thus subjective assessments including the aspect of observers are required. The changes in the ability to detect lesions caused by changes in the thickness of acrylic plates were tested with the ROC interpretation method that has taken into consideration, all the features of physical assessments as well as observers' ability to observe and mental stages and even surrounding environments using an Alvim phantom and the result indicated that as the thickness of acrylic plates increased, the amount of noises occurred increased compared to signals and thus the ability to detect signals as well as the sensitivity that is an ability to signals accurately and the ability to distinguish noises from signals thus it is considered that more efforts of radiologic technologists will be required to detect small lesions of fat patients with diagnostic X-ray generating apparatus.

  • PDF

수술실 내 C-arm 장치의 산란선 분포에 대한 연구 (The Study on Scattered Ray by C-arm in Operation Room)

  • 박성현;박주미;김현수
    • 대한디지털의료영상학회논문지
    • /
    • 제13권1호
    • /
    • pp.21-26
    • /
    • 2011
  • A radiation imaging system used in a surgery room is mainly using C-arm which is purposed to fluoroscope. C-arm is often use to watch an operation's accuracy and progress, but not only being bombed to this first beam but also affected to this scattered beam, so now we are look for the way to reduce bombed amount of doctor, nurses and radiological technologists. We measured the exposure dose in $0^{\circ}$ spot according to the distance to find out frequency distribution of scattered ray in an operation room and found the spot which has the same exposure dose from $30^{\circ}$ distance of all directions and wrote isodose curve. We analyzed the data and found out the sudden reduction of scattered ray according to the long direction also found out that scattered ray was not related to the directions. Operators must recognize the reduction of exposure dose. Because reducing scattered ray from all directions in an operation room is really difficult. So every operators must use shelters to reduce the exposure dose and notice the safety.

  • PDF

응급실에서의 채혈로 인한 용혈 및 재채혈 관련요인 (Factors Affecting Hemolysis in Blood Sampling and Repeated Sampling in the Emergency Department)

  • 조명숙;황문숙
    • 임상간호연구
    • /
    • 제17권3호
    • /
    • pp.399-410
    • /
    • 2011
  • Purpose: This study was conducted to investigate the incidence of blood hemolysis and repeated blood sampling and to identify factors contributing to hemolysis and repeated blood sampling in the emergency department. Methods: A cross-sectional descriptive design was used. Participants were the patients who came to emergency department and are required a blood sampling for electrolyte level. All blood samples were collected by emergency department nurses and determined for hemolysis by experienced laboratory technologists. Data were analyzed using $x^2$-test, Fisher's exact test, Mann-Whitney u test and Binary Logistic Regression to determine significant differences. Results: A total of 402 valid samples were collected. Of these, 30 blood samples (7.5%) were found to be hemolyzed and 9 (2.2%) to be recollected. Statistically significant factors affecting on hemolysis and repeated blood sampling included the time of bloods sampling (night), the time of tourniquet application, and too-fast blood draw into the test tube. Conclusion: We recommend that nurses who take the blood sampling to consider the findings of the study and take the related factors into account as they set up the standardized care protocol in order for nursing quality improvement.

전산화단층촬영검사실 방사선사의 방사선피폭 방어행위에 영향을 미치는 요인 분석 (Factors Influencing Protective Behavior against Radiation Exposure of Radiological Technologist in Computed Tomography Examination Room)

  • 김기정;정홍량;홍동희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.581-586
    • /
    • 2018
  • This study was conducted to analyze factors Influencing Protective Behavior against Radiation Exposure using questionnaires for 231 radiological technologists working in Computed Tomography(CT) examination room with high radiation dose in diagnostic radiology field. Statistical analysis of the collected data revealed that the reasons for partially shielding the examination part in the CT scan were the lack of protective equipment, securing of radiation justification, being annoying and maybe not being harm to adults in order. It was also revealed that the variables influencing the protective behavior were protective behavior against radiation harm, self-efficacy, protective environment, organization culture, protective knowledge and protective instrument in order. The higher the radiological protective environment(${\beta}=0.245$) and the lower the radiological protective knowledge(${\beta}=-0.034$), the more influential the protective behavior against radiation harm was. In this study, it was shown that non examination parts were not shielded in the CT scan. Therefore, it is necessary to improve the level of protective environment, to cultivate knowledge to improve the protective behavior against radiation harm and to have an intervention strategy for concrete action.