• Title/Summary/Keyword: Medical radioisotope

Search Result 115, Processing Time 0.018 seconds

Proposal of a New Estimation Method of Colonization Rate of Arbuscular Mycorrhizal Fungi in the Roots of Chengiopanax sciadophylloides

  • Deguchi, Seitaro;Matsuda, Yosuke;Takenaka, Chisato;Sugiura, Yuki;Ozawa, Hajime;Ogata, Yoshimune
    • Mycobiology
    • /
    • v.45 no.1
    • /
    • pp.15-19
    • /
    • 2017
  • This study proposed a rapid method to quantify the colonization rate of arbuscular mycorrhizal fungi (AMF) in plant roots. The method involved the use of an image analysis software (WinRHIZO Pro). The colonization rate is defined as the ratio of the fungal body to the plant root area in a micrograph. Three seedlings of Chengiopanax sciadophylloides, a woody species that accumulates radiocesium, were collected from a secondary forest in the Yamakiya district of Kawamata, Fukushima Prefecture during May-September 2014. The colonization of AMF structures was examined under a light microscope, and the percentage of colonization was determined using the WinRHIZO method. The superiority of the new method was verified by comparing with a modified grid-line intersect method. The colonization of AMF was confirmed in all the seedlings, and a significant coefficient of determination ($R^2=0.94$) was found with both the methods. The results suggested that the WinRHIZO method is reliable for estimating the colonization of AMF in C. sciadophylloides.

A Study on the Radioactive Products of Components in Proton Accelerator on Short Term Usage Using Computed Simulation (몬테칼로 시뮬레이션을 활용한 양성자가속기 단기사용 시 구성품의 방사화 평가)

  • Bae, Sang-Il;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.389-395
    • /
    • 2020
  • The evaluation of radioactivated components of heavy-ion accelerator facilities affects the safety of radiation management and the exposure dose for workers. and this is an important issue when predicting the disposal cost of waste during maintenance and dismantling of accelerator facilities. In this study, the FLUKA code was used to simulate the proton treatment device nozzle and classify the radio-nuclides and total radioactivity generated by each component over a short period of time. The source term was evaluated using NIST reference beam data, and the neutron flux generated for each component was calculated using the evaluated beam data. Radioactive isotopes caused by generated neutrons were compared and evaluated using nuclide information from the International Radiation Protection Association and the Korea Radioisotope association. Most of the nuclides produced form of beta rays and electron capture, and short-lived nuclides dominated. However, In the case of 54Mn, which is a radioactive product of iron, the effect of gamma rays should be considered. In the case of tritium generated from a material with a low atomic number, it is considered that handling care should be taken due to its long half-life.

FABRICATION OF NEO-OSSEOUS FLAP USING DEMINERALIZED ALLOGENEIC BONE (탈회동종골을 이용한 신혈류화골판 형성에 관한 연구)

  • Lee, Jong-Ho;Kim, Hyeon-Tae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.17 no.3
    • /
    • pp.253-263
    • /
    • 1995
  • Microsurgical vascularized bone transfer has the disadvantages of limitation of available donor sites, loss of donor function, and the possibility of donor site defects or deformity. To overcome these shortage of current microsurgical tissue transfer, the method of creating the neovascularized free flap has been introduced. Potentially, this technique must be an innovation in providing the free vascularized bone grafts that are not limited by natural vascular anatomy. But, as could be imagined technique resulted in unavoidable donor bone defect and additional operation for harvesting the autologous bone. The purpose of this study was to evaluate the efficacy of demineralized allogeneic bone as a possible substitute for autologous bone in fabricating the neo-osseous flap. By histologic, microangiographic and radioisotope method, the viability and vascularity of neo-osseous flap, which has been fabricated using allogeneic bone or autologous bone, was assessed in rat model. After 6 weeks, demineralized allogeneic bone showed consistent bone formation and neovascularization. The clinical and microscopic findings of demineralized allogeneic bone group were inferior to those of autogenous bone with regard to bone regeneration. The amount of bone blood floow per dry weight of demineralized allogeneic bone group was significantly higher than that of autogenous bone, even higher that of control intact iliac bone. In conclusion, findings supported that allogeneic bone could be the potential substitute for autologous bone source in creating a prefabricated neo-osseous flap.

  • PDF

Implementation of waste silicate glass into composition of ordinary cement for radiation shielding applications

  • Eid, Mohanad S.;Bondouk, I.I.;Saleh, Hosam M.;Omar, Khaled M.;Sayyed, M.I.;El-Khatib, Ahmed M.;Elsafi, Mohamed
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1456-1463
    • /
    • 2022
  • The aim of this work is to study the radiation shielding properties of cement samples with waste glass incortated into its composition. The mass attenuation coefficient (MAC) of the samples were experimentally determined to evaluate their radiation shielding ability. The experimental coefficient was evaluated using NaI detector for gamma energies between 59.53 keV and 1408.01 keV using different radioactive point sources Am-241, Eu-152, Co-60, and Cs-137, and the gamma transmission parameters half-value layer, mean free path, and transmission factor were calculated. The theoretical coefficient of the composites was determined using Geant4 and XCOM software. The results were also compared against Geant4 and XCOM simulations by calculating the relative deviation between the values to determine the accuracy of the results. In addition the mechanical properties (including Compressive and porosity) as well as the thermogravimetric analysis were tested for the present samples. Overall, it was concluded that the cement sample with 50% waste glass has the greatest shielding potential for radiation shielding applications and is a useful way to reuse waste glass.

Cu-64 as a Cancer Theranostics Agent

  • Kwang Il Kim
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.2
    • /
    • pp.139-150
    • /
    • 2022
  • Theranostics, a composite word of therapy and diagnosis, is known as personalized medicine and the concept of diagnosis and treatment at the same time. In nuclear medicine, it means performing both therapeutic and diagnostic radioisotope therapy using the same target molecule. The increased production and utilization of 64Cu opens a new era of theranostics. The studies introduced here have shown that 64CuCl2 and various compounds or biomolecules labeled with 64Cu are unique radiopharmaceuticals with physiological properties suitable for use as diagnostic and therapeutic agents. So far, these two abilities have been described only for radioactive iodine. Although 64Cu has complex chemical properties compared to other PET radioisotopes such as 68Ga, it has an appropriate half-life and enables high-quality PET images similar to 18F, which is an advantage in terms of diagnosis. In addition, since it also has therapeutic properties through the release of β- particles and Auger electrons by electron capture, radiopharmaceuticals using 64Cu stand for innovative radiopharmaceuticals for theranostic purposes. Therefore, based on the initial results obtained using 64Cu as a therapeutic agent, it is expected that additional research on the application of 64Cu will lead to a new era in the theranostics field.

The rapid synthetic strategy of [11C]PIB via disposable column cartridge purification

  • Jihye Lee;Yansheng Li;Sang-Yoon Lee;Tatsuo Ido
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.6 no.2
    • /
    • pp.69-74
    • /
    • 2020
  • PIB is the first amyloid plaque PET image tracer reported for the first time in 2003, and is considered to be the best and is still being utilized due to its very high uptake and kinetic properties. Initially, it was synthesized by radioisotope labeling using a precursor containing a methoxy methyl protection group, but now it is synthesized using a 6-OH precursor that can be easily synthesized in one step using [11C]methyl triflate. Carbon-11 has several limitations in clinical studies using PET because its half-life is as short as 20 minutes. In this study, in order to overcome the difficulty of this half-life, a rapid method using Sep-Pak was adopted instead of HPLC purification to significantly reduce the burden of the purification process and attempted synthesis. As a result, the synthesis time was shortened by more than 50%, and the yield of the final compound was higher than the previous result and showed relatively high specific radioactivity, confirming that it is a strategic method with high applicability for various precursors having primary amines.

Quantitation of Plasma Apolipoprotein A-I with a Sandwich Type Enzyme-Linked Immunosorbent Assay Using Monoclonal Antibodies

  • Lee, Min-Gyu;Kang, Jae-Seon;Jeong, Jae-Yeon;Jue, Dae-Myung;Kim, Hack-Joo
    • BMB Reports
    • /
    • v.30 no.6
    • /
    • pp.390-396
    • /
    • 1997
  • A sandwich-type enzyme-linked immunosorbent assay (ELISA) for the quantification of human apolipoprotein A-I (apoA-I) was developed using monoclonal antibodies. For this assay, we used three monoclonal antibodies to trap and detect apo A-I. HDAI16 and HDA15 monoclonal antibodies were used for trapping apoA-I and HDAI8 monoclonal antibody was for detecting apoA-I. These three monoclonal antibodies were produced by immunizing mice with high density lipoprotein (HDL) isolated from human plasma. By immunoblot analysis, these three monoclonal antibodies were specific to apoA-I and showed no cross-reactivities with other plasma proteins. The results of competition assays for epitope cross-reactivity test also verified that these monoclonal antibodies identified separate and distinct epitopes on HDL and apoA-I. Affinity constants of monoclonal antibodies were measured by ELISA. Their association constants ranged from $10^7$ to $10^8$ $M^{-1}$. For this assay, pure apoA-I was isolated by affinity chromatography using monoclonal antibodies. In this sandwich assay, the amount of HRP-labeled HDAI8 bound to apoA-I trapped by HDAI16 and HDAI5 was proportional to apoA-I concentration in the range of 0 to 500ng/ml. ApoA-I concentration in plasma was calculated from the linear regression equation of standard curve. The precision and reliability of the assays are reflected in the low intra-and interassay coefficients of variation that averaged 3.25% and 4.30%, respectively. This assay is sensitive, simple, reproducible, convenient in incubation interval, and does not use radioisotope: thus it can be widely applied in clinical laboratories.

  • PDF

Study on the Compatibility for an Ir-192 Source Manufactured by Korea Atomic Energy Research Institute (KAERI) in GammaMed Brachytherapy Machine (한국원자력연구소에서 개발한 Ir-192 선원의 감마메드 치료기 호환성 연구)

  • Jeong, Dong-Hyeok;Lee, Kang-Kyoo;Kim, Soo-Kon;Moon, Sun-Rock
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.78-85
    • /
    • 2010
  • The compatibility with GammaMed-12i brachytherapy machine for an Ir-192 encapsulated source (IRRS20, KAERI, Korea) manufactured by Korea atomic energy research institute (KAERI) has been investigated. As a mechanical testing of compatibility, precise measurement of step movement with channels, measurement of curvature of radius for wire, and emergency return testing were performed. Periodic measurements of air kerma strength for 45 days were carried out to evaluate decay characteristics of Ir-192 radioisotope and comparison of dose distributions in phantom between KAERI and old sources previously used were performed by film dosimetry. KAERI source has a good compatibility with GammaMed12i machine as a result of mechanical testing. There are in good agreement with calculated values in activity characteristics and there were small differences in dose distributions around the source in comparison between KAERI and old source.

Absorbed Dose from Large Balloon Filled with Liquid Ho-166

  • Joh, Chul-Woo;Park, Chan H.;Lee, Myoung-Hoon;Yoon, Seok-Nam;Kim, Mi-Hwa;Jang, Ji-Sun;Park, Kyung-Bae
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.328-330
    • /
    • 2002
  • Large balloon angio catheter is used for Percutaneous Transluminal Angioplsty(TPA) of the iliac, femoral and renal arteries as well as after Transjugular Intrahepatic portosystemic shunt(TIPS). The use of angioplasty balloon filled with liquid form of radioisotope reduces the rate of restenosis after PTA. The purpose of this study was to evaluate the absorbed dose to the target vessels from various sized large balloon filled with liquid form of Ho-166-DTPA. Four balloons of balloon dilatation catheters evaluated were 5, 6, 8 and 10 mm in diameter. GafChromic film was used for the estimation of the absorbed dose near the surface of the balloon catheters. Absorbed dose rates are plotted in units of Gy/min/GBq/ml as a function of radial distance in mm from the surface of balloon. The absorbed dose rate was 1.1, 1.6, 2.2 and 2.3 Gy/min/GBq/ml at a balloon surface, 0.3, 0.4, 0.5 and 0.6 Gy/min/GBq/ml at 1 mm depth for various balloon diameter 5, 6, 8 and 10 mm in diameter respectively. The study was conducted to estimate the absorbed doses to the vessels from various sized large balloons filled with liquid form of Ho-166-DTPA for clinical trial of radiation therapy after the PTA. The absorbed dose distribution of Ho-166 appeared to be nearly ideal for vascular irradiation since beta range is very short avoiding unnecessary radiation to surrounding normal tissues.

  • PDF

Evaluation of Scintillation Camera Applications of 3D Printing Phantom (3D 프린팅 팬텀의 섬광카메라 적용 평가)

  • Park, Hoon-Hee;Lee, Ju-young;Kim, Ji-Hyeon
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.343-350
    • /
    • 2021
  • 3D printing technology is an additive manufacturing technology produced through 3D scanning or modeling method. This technology can be produced in a short time without mold, which has recently been applied in earnest in various fields. In the medical field, 3D printing technology is used in various fields of radiology and radiation therapy, but related research is insufficient in the field of nuclear medicine. In this study, we compare the characteristics of traditional nuclear medicine phantom with 3D printing technology and evaluate its applicability in clinical trials. We manufactured the same size phantom of poly methyl meta acrylate(PMMA) and acrylonitrile butadiene styrene(ABS) based on the aluminum step wedge. We used BrightView XCT(Philips Health Care, Cleveland, USA) SPECT/CT. We acquired 60 min list mode for Aluminum, PMMA and ABS phantoms using Rectangular Flood Phantom (Biodex, New York, USA) 99mTcO4 3 mCi(111 MBq), 6 mCi (222MBq) and 57Co Flood phantom(adq, New Hampshire, USA). For the analysis of acquired images, the region of interest(ROI) were drawn and evaluated step by step for each phantom. Depending on the type of radioisotope and radiation dose, the counts of the ABS phantom was similar to that of the PMMA phantom. And as the step thickness increased, the counts decreased linearly. When comparing the linear attenuation coefficient of Aluminum, PMMA and ABS phantom, the linear attenuation coefficient of the aluminium phantom was higher than that of the others, and the PMMA and ABS phantom had similar the linear attenuation coefficient. Based on ABS phantom manufactured by 3D printing technology, as the thickness of the PMMA phantom increased, the counts and linear attenuation coefficient decreased linearly. It has been confirmed that ABS phantom is applicable in the clinical field of nuclear medicine. If the calibration factor is applied through further research, it is believed that practical application will be possible.