• Title/Summary/Keyword: Medical radiation

Search Result 3,787, Processing Time 0.044 seconds

Fenofibrate Increases Radiosensitivity in Head and Neck Squamous Cell Carcinoma via Inducing G2/M Arrest and Apoptosis

  • Liu, Jia;Ge, Yang-Yang;Zhu, Hong-Cheng;Yang, Xi;Cai, Jing;Zhang, Chi;Lu, Jing;Zhan, Liang-Liang;Qin, Qin;Yang, Yan;Yang, Yue-Hua;Zhang, Hao;Chen, Xiao-Chen;Liu, Zhe-Ming;Ma, Jian-Xin;Cheng, Hong-Yan;Sun, Xin-Chen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.16
    • /
    • pp.6649-6655
    • /
    • 2014
  • Radiation therapy is an important treatment for head and neck squamous cell carcinoma (HNSCC). However, how to promote radiation sensitivity in HNSCC remains a challenge. This study aimed to investigate the radiosensitizing effects of fenofibrate on HNSCC and explore the underlying mechanisms. HNSCC cell lines CNE-2 and KB were subjected to ionizing radiation (IR), in the presence or absence of fenofibrate treatment. Cell growth and survival, apoptosis and cell cycle were evaluated. In addition, CNE-2 cells were xenografted into nude mice and subjected to IR and/or fenofibrate treatment. The expression of cyclinB and CDK1 was detected by Western blotting. Our results showed that fenofibrate efficiently radiosensitized HNSCC cells and xenografts in mice, and induced apoptosis and G2/M arrest via reducing the activity of the CDK1/cyclinB1 kinase complex. These data suggest that fenofibrate could be a promising radiosensitizer for HNSCC radiotherapy.

Environmental Radiation Protection in Medical Institutions

  • Han, Eun-Ok;Dong, Kyung-Rae
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.91-95
    • /
    • 2010
  • The study aimed to measure the levels of radiation protection for radiologists in medical institutions in three environmental categories (physical, administrative and social) and to establish a data base which can be used to increase awareness of environmental radiation protection in medical institutions within Korea. The study surveyed 10% of radiologists working in radiology departments in medical institutions which are supervised by the National Dose Registry overseen by the Korean Food and Drug Administration(KFDA). This study found that the level of environmental radiation protection was higher in the capital area and in larger hospitals. On the other hand, the study shows environmental radiation protection was lower in the Youngnam area and in clinics. Results from the questionnaires indicate the level of environmental radiation protection was higher when radiologists were given an individual dosimeter but lowest when the radiation protection apron quality test was conducted. Environmental radiation protection is an important factor for radiologists to conduct activities in a safe and protected environment. However, this study shows there are differences in the level of environmental radiation protection in medical institutions and location within Korea. In particular, the level of environmental radiation protection was lower in clinics, appropriate intervention strategies befitting these conditions are needed based on medical institution classification and location in order to improve the level of environmental protection.

Patterns of recurrence after radiation therapy for high-risk neuroblastoma

  • Jo, Ji Hwan;Ahn, Seung Do;Koh, Minji;Kim, Jong Hoon;Lee, Sang-wook;Song, Si Yeol;Yoon, Sang Min;Kim, Young Seok;Kim, Su Ssan;Park, Jin-hong;Jung, Jinhong;Choi, Eun Kyung
    • Radiation Oncology Journal
    • /
    • v.37 no.3
    • /
    • pp.224-231
    • /
    • 2019
  • Purpose: To investigate the patterns of recurrence in patients with neuroblastoma treated with radiation therapy to the primary tumor site. Materials and Methods: We retrospectively analyzed patients with high-risk neuroblastoma managed with definitive treatment with radiation therapy to the primary tumor site between January 2003 and June 2017. These patients underwent three-dimensional conformal radiation therapy or intensity-modulated radiation therapy. A total of 14-36 Gy was delivered to the planning target volume, which included the primary tumor bed and the selected metastatic site. The disease stage was determined according to the International Neuroblastoma Staging System (INSS). We evaluated the recurrence pattern (i.e., local or systemic), progression-free survival, and overall survival. Results: A total of 40 patients with high-risk neuroblastoma were included in this study. The median patient age was 4 years (range, 1 to 11 years). Thirty patients (75%) had INSS stage 4 neuroblastoma. At the median follow-up of 58 months, there were 6 cases of local recurrence and 10 cases of systemic recurrence. Among the 6 local failure cases, 4 relapsed adjacent to the radiation field. The other 2 relapsed in the radiation field (i.e., para-aortic and retroperitoneal areas). The main sites of distant metastasis were the bone, lymph nodes, and bone marrow. The 5-year progression-free survival was 70.9% and the 5-year overall survival was 74.3%. Conclusion: Radiation therapy directed at the primary tumor site provides good local control. It seems to be adequate for disease control in patients with high-risk neuroblastoma after chemotherapy and surgical resection.

Analysis of Treatment and Delay Times by Disease Site and Delivery Technique at Samsung Medical Center - Proton Therapy Center

  • Jo, Kwanghyun;Ahn, Sung Hwan;Chung, Kwangzoo;Cho, Sungkoo;Shin, Eunhyuk;Hong, Chae-Seon;Park, Seyjoon;Kim, Dae-Hyun;Lee, Boram;Lee, Woo-Jin;Seo, Se-Kwang;Jang, Jun-Young;Choi, Doo Ho;Lim, Do Hoon;Han, Youngyih
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.258-266
    • /
    • 2016
  • We have treated various disease sites using wobbling and scanning proton therapy techniques since December 2015 at the Samsung Medical Center. In this study, we analyze the treatment time for each disease site in 65 wobbling and 50 scanning patient treatments. Treatment times are longest for liver and lung patients using the respiratory gating technique in the wobbling treatment and for cranio-spinal irradiation in pediatric patients with anesthesia in the scanning treatment. Moreover, we analyze the number of incidents causing treatment delays and the corresponding treatment delay time. The X-ray panel was the main reason for delays in the wobbling treatment; this decreased continually from January to June 2016, related closely to the proficiency of the human operators involved. The main reason for delays in the scanning treatment was interlocks during scanning pattern delivery; this was resolved by proton machine engineers. Through this work, we hope to provide other institutes with useful insight for initial operation of their proton therapy machines.

Organ dose reconstruction for the radiation epidemiological study of Korean radiation workers: The first dose evaluation for the Korean Radiation Worker Study (KRWS)

  • Tae-Eun Kwon;Areum Jeong;Wi-Ho Ha;Dalnim Lee;Songwon Seo;Junik Cho;Euidam Kim;Yoonsun Chung;Sunhoo Park
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.725-733
    • /
    • 2023
  • The Korea Institute of Radiological and Medical Sciences has started a radiation epidemiological study, titled "Korean Radiation Worker Study," to evaluate the health effects of occupational exposure to radiation. As a part of this study, we investigated the methodologies and results of reconstructing organ-specific absorbed doses based on personal dose equivalent, Hp(10), reported from 1984 to 2019 for 20,605 Korean radiation workers. For the organ dose reconstruction, representative exposure scenarios (i.e., radiation energy and exposure geometry) were first determined according to occupational groups, and dose coefficients for converting Hp(10) to organ absorbed doses were then appropriately taken based on the exposure scenarios. Individual annual doses and individual cumulative doses were reconstructed for 27 organs, and the highest values were observed in the thyroid doses (on average 0.77 mGy/y and 10.47 mGy, respectively). Mean values of individual cumulative absorbed doses for the red bone marrow, colon, and lungs were 7.83, 8.78, and 8.43 mSv, respectively. Most of the organ doses were maximum for industrial radiographers, followed by nuclear power plant workers, medical workers, and other facility workers. The organ dose database established in this study will be utilized for organ-specific risk estimation in the Korean Radiation Worker Study.

Research of Awareness for Medical Radiation Safety in Radiography (방사선검사 시 의료방사선 안전성에 대한 인식도 조사)

  • Kim, Gyoo-Hyung
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.255-260
    • /
    • 2018
  • Most patients and parents and guardians display frequent anxiety due to radiation exposure during outpatient, ward, and pediatric general radiographic examinations. This is a behavior that perceives only the harmfulness of radiation. For the recognition of medical radiation, we conduct surveys on outpatients, inpatients, and pediatric parents and guardians to identify their awareness, and then use the radiation dose promotional materials After providing accurate information on the use of radiation, the outpatient, inpatient, and pediatric parents and guardians were asked to explain the change in awareness. The questionnaire items were classified into five categories: repetitive radiation awareness for diagnosis, awareness of exposure dose, availability of exposure information, awareness of radiation risk, and awareness of health problems caused by radiation. There was a statistically significant difference in the items of recognition result of medical radiation, although there was a slight difference in the individual items in the pre and post-recognition results of providing information about the radiologists of the protector and the outpatient(p<0.05). Therefore, through the installation of these promotional materials, we will improve our awareness of medical radiation safety during general radiography surveillance in the Department of Radiology to provide better quality medical information and medical services, thereby contributing to strengthening the competitiveness of the hospital.