• Title/Summary/Keyword: Medical optics

Search Result 160, Processing Time 0.018 seconds

The Research on the Optical Reliability of Spectacle Lens in Korea (국내 안경렌즈 광학적 요소 신뢰성 조사)

  • Kim, Tae-Hun;Ye, Ki-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.43-48
    • /
    • 2008
  • Purpose: This study is to evaluate reliability of geometrical optics properties of spectacle lenses by using ISO and the medical instrument standard of KFDA, which are being sold in Korea. Methods: We used samples of three hundred and ninety eight spectacle lenses of eight company in total. Refractive indices of each samples which were used in experiment were classified into three groups of medium index (1.55~1.56), high index (1.60~1.61) and extra high index (1.67). Results: Conformity of refractive power was 81.61% in total spectacle lenses. The results showed that thickness conformity 90%, appearance conformity 85.18%, size conformity 96.23% and optical center point conformity 99.50% in total. Conclusions: We found that they deviated from the permitting value in many spectacle lenses on refractive power. The results of errors on prism power, surface inspection and optical center point showed small values in total products. In experiment of lens size and thickness, the bulk of indication rates and conformities of samples deviated from the permitting errors.

  • PDF

A Study on the Improvement of Visual Acuity and Refractive Power According to General Characteristics of Cataract Surgery Patients

  • Cho, Seon Ahr;Lee, Seong Jae
    • International Journal of Advanced Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.71-79
    • /
    • 2018
  • For 299 patients who had undergone cataract surgeries we investigated the difference in visual acuity and refractive power before and after cataract surgery and the clinical change of the visual acuity and the refractive power according to age, gender, hospital visit time and specific medical history. We found the factors affecting preoperative and postoperative outcomes of the cataract patients in metropolitan hospitals by input, process, and outcome and analyzed medical characteristics and patient characteristics as the input variables. T-test and ANOVA have been performed for statistical analysis of functional status, and general status and the technical characteristic as the process variable and the outcome variable of diagnosis. Visual acuity improved significantly in patients who had undergone cataract surgery. However, the change in refractive power did not show a statistically significant difference but only a slight difference. The improvement of male patients was greater than that of female patients. The difference in age was more effective in patients under 50 years old and the effect of cataract surgery was relatively high in patients without the presence of specific medical history. Cataract surgery did not seem to help all of the patients, but it is more effective in improving visual acuity and refractive power. We conclude that simultaneous cataract surgery in both eyes is reasonable in order to have at least the better effect.

Optical System Design for Real-Time 3-Dimension Ophthalmoscope (실시간 3차원 검안경의 광학설계)

  • Lee, Soak-Hee;Yang, Yun-Sik;Choe, Oh-Mok;Sim, Sang-Hyun;Doo, Ha-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.35-39
    • /
    • 2003
  • The display technology on the retina is the key role in inspecting the condition of the patients. 2-dimensional retina image is widely used in the eye examination as of today. Recently, 3-dimensional retina image ones have been introduced to this area, but the quality of the image is not fully satisfied to the operator. For the purpose of developing 3-D retina imaging instrument, the optimization of a 3-D retina imaging system using Code-V tool was investigated in this thesis. He-Ne laser having the wavelength 632.8 nm was used to make a power source to detect the retina. Several lenses and mirrors installed on sledge which were developed to perform focus control on 3-D device were designed to make a beam focusing and direct line. Polygon scanner having 24 mirror facets and galvanometer making tilting movement were utilized to make a 2-D laser plane. Also, design of eye ball had been fulfilled to see the focus of the 2-D plane. Reflected ray from retina detected on the sensor array with the same path. All cognitive components were optimized for aberration correction in order to focus on retina. Results of optimization were compared to those of initial designed optics system. On the basis of above results, the result of third aberration has been corrected to stable values to the optical system. MTF evaluating the resolution of an image has been closely correlated to the diffraction limit and PSF indicating the strength distribution of an image has shown the SR value as 0.9998 having high performance. The possibility of new and powerful 3-D retina image instrument was verified by simulating each component of the instrument by Code-V.

  • PDF

Time-Phased Implementation of a Large-Scale PACS at Samsung Medical Center

  • Ro, Duk-Woo;Choi, Hyung-Sik;Lim, Jae-Hoon;Kim, Won-Ki
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.26-27
    • /
    • 1994
  • The first step implementation of a hospital-wide Picture Archiving Communications System (PACS) at a newly built hospital Samsung Medical Center (SMC), is described. Current clinical operation encompasses the fiber optics delivery of direct-interfaced magnetic resonance imager (LRI), X-ray computed tomography (CT). digital subtraction angiography (DSA) and computed radiography (CR) digital images via high performance file server to the departments of radiology, neurosurgery, orthopedics surgery, neurology, emergency room and the surgical intensive care unit.

  • PDF

A Study on Glasses Design about Construction of an End Piece (안경디자인의 엔드피스 구조에 관한 연구)

  • Kang, Min-Soo;Kim, In-Soo;Kang, Sung-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.249-258
    • /
    • 2006
  • There are many functions of glasses. Not only as a medical instrument but also for decorative purpose and individuality as a mean of expression. The concept of glasses applied according to various purposes and use. Following the designers' point of view, the most important research task is to make products substantial and convenient rather than external beauty after analysis problems and the needs of customers. Because customers ask for the best quality of design all the time. The best design of glass includes essential conditions like; creativity, satisfaction, convenience of use, identity. These conditions are common elements of glasses in both domestic and foreign markets. Also they can be a catalyst to stimulate glasses industry in Korea. First of all to study tho parts of glasses "End Piece", it is essential to consider for a better design. Because it adjusts the center of glasses weight balance for user's comfort. Since many brands are imitated, the significance of "End piece" is of a great importance resulting in a more successful competitiveness.

  • PDF

The Study on Refractive Amblyopia (굴절성 약시안에 대한 고찰)

  • Park, Hyun-Ju;Lee, Seok-Ju;Yim, Tae-Jun;Kim, Jai-Min;Lee, Ki-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.345-352
    • /
    • 2004
  • We investigated the effect of age at initial correction, of 44 refractive amblyopic patients duration of correction on corrected visual acuity with the lapse of time for mean 33months(3months-59months). Full cycloplegic corrections were prescribed at the initial visit to all subjects. The distribution of initial corrected visual acuity was 0.02 to 0.5. Age at initial correction varied from 3 years to 12 years. The refractive error appeared to have the greatest influence on the visual outcome, showing continuous visual improvement after initial correction. But the age at initial correction did not appear to influence on the initial and final corrected visual acuity showed a significant difference, irrespective of age at the initial correction Or degree of anisometropia.

  • PDF

마이크로머시닝 기술의 의학 및 생물학 응용

  • 장준근;김용권
    • The Magazine of the IEIE
    • /
    • v.24 no.10
    • /
    • pp.63-72
    • /
    • 1997
  • Application of MEMS to biologic system mainly categorized into bio-electronics and micro-medical systems, Bio-electronics concerns on the biocompatible electronic device, in-vivo sensors, the sensors based on biological materials, biological materials for electronics and optics, the concepts and materials Inspired by biology and useful for electronics, the algorithm inspired by biology, artificial sense, and the biologic-inorganic hybrids. Micro-medical systems are utilited into the drug delivery systems, micro patient monitoring systems, micro prosthesis and artificial organs, cardiology related prothesis, analysis systems, and the minimal invasive surgery tools based on the m icrom achining technology.

  • PDF

Medical Laser (의료용 Laser)

  • 김덕원
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.107-113
    • /
    • 1990
  • Characteristics and applications of three major types of lasers are discussed. They are chemical-metabolic, thermal destructive, and nonthermal mechanical lasers. The thermal destructive lasers ($CO_2$, Argon, and Nd:YAG) are especially explained in detail with regard to energy density, wavelength, fluence, stage of thermal destruction, and advantages of laser surgery. Excimer and Q-swiched lasers are discussed as nonthermal mechanical ones. Delivery system, optical fiber and articulated arm, is also discussed. Finally, recent advancements of medical laser are included in the conclusion.

  • PDF

A Study on the Difference of Cataract Surgery Prognosis between Adult Diseases and Non-adult Diseases (성인병 여부에 따른 백내장 수술 효과의 차이 연구)

  • Cho, Seon-Ahr
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.275-280
    • /
    • 2016
  • Purpose: This study is intended to look into the difference in surgery effects through the analysis of risk factors on how the common adult diseases among Korean adults diseases (glaucoma, hypertension and diabetes) are affecting cataract. Methods: Cataract surgery patients' daily records at hospitals in Jeonnam were used as analysis data. Factors - which can affect the results of medical treatment before and after an operation - were classified into the input, process and outcome of medical treatment. The medical treatment and patient characteristics were reflected as the input of medical treatment, and clinical results, functional status and general status as the process of medical treatment. Results: There was a close relationship between adult diseases of glaucoma, diabetes and hypertension, and cataract. Visual acuity of adult diseases patients was 10% lower than of non-adult diseases patients. And for post-surgery it was around 16% difference in refractive error and visual acuity between two groups. Conclusions: According to a study result, the cataract has been confirmed that there is a close relationship of Adult disease patients's glaucoma, diabetes and hypertension. Depending on the type about these adult diseases, before and after cataract surgery, vision and refractive power was found to indicate a significant difference when compared with conventional low normal adult control.

A Review on the paradiam of Eyewear Design Concept (안경 design concept의 paradigm에 관한 고찰)

  • Kang, Hyunshik;Jang, Woo-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.189-195
    • /
    • 2004
  • Eyewear must not be judged only by the skill of the designer who created it. For production of successful eyewear, we must always take into account the point of view of the wearer. Because eyewear is above all a means to correct of the visual acuity, it is a medical instrument. Therefore in any case, it should not submit to the dictatorship of fashion designer. The eyewear designer's role may therefore be summarized in following way: to have a subtle sensitivity and inspiration, and originality, know-how to develop a symbiosis between functionality and technical know-how, harmonious production of the design and concept of the human engineering. At present, the way of designing has undergone a big change to enabling us to supply the customer with technical design and rapid prototyping of eyewear with assistance to computer processing such as computer graphic and cad/cam.

  • PDF