• Title/Summary/Keyword: Medical measurement

Search Result 2,717, Processing Time 0.038 seconds

Adaptive Control of Multiplexed Closed Circuit Anesthesia

  • Jee, Gyu-In;Roy, Rob
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.79-81
    • /
    • 1992
  • This paper describes the design of an adaptive closed circuit anesthesia controller based on a multiplexed mass spectrometer system. The controller deals with measurement deterioration caused by measurement delay and rise time through a tong catheter as well as long sampling times due to the multiplexed measurements. Measurement data is extrapolated between sampling periods to increase the estimation convergence rate. A multiple-step-ahead predictive control algorithm is used to calculate intermediatc control inputs between sampling intervals. Simulations are used to validate the designed controller.

  • PDF

A Study on Measurement of Electroencephalogram Using Micro-Computer (Micro-Computer를 이용한 뇌파측정에 관한 연구)

  • 김현욱;박명규
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.6 no.8
    • /
    • pp.27-34
    • /
    • 1983
  • Bioelectrical measurement has long been an important area in medical researches and practices, and contributed valueable data to the field of human engineering. In particular, the measurement of EEG has been widely used for the study of brain function as well as for the diagnosis of various brain disorders. The present study tried to improve conventional measurements of EEG in that FFT algorithm with microcomputer machine language was applied to facilitate the computation of various aspects of the EEG.

  • PDF

CHANGE OF LIP CANTING AFTER BIMAXILLARY ORTHOGNATHIC SURGERY (상하악 악교정수술 후 입술 기울기변화)

  • Lee, Jun-Hee;Hong, Jong-Rak;Kim, Young-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.6
    • /
    • pp.643-647
    • /
    • 2007
  • Purpose: The purpose of study was to investigate the correlationship between lip canting change and occlusal canting change after bimaxillary orthognathic surgery, and the ratio of lip canting change and occlusal canting change after the surgery. Patients and methods: The subjects for this study was obtained from a group of 25 patients who took bimaxillary orthognathic surgery for occlusal canting correction at the Department of the Oral and Maxillofacial Surgery, Samsung Medical Center in Seoul, Korea between January 2000 and December 2005 and a patient's chart had to contain a resting frontal facial photograph in natural head position and a corresponding PA cephalogram in occlusion on the same day before the surgery and post-op 6 months later. The lip canting change was assessed with the angle each labial commissure and the bipupilary reference line. And, the occlusal caning change in the frontal plane was assessed with the angle between the each maxillary first molar occulasal surface and the bi-frontozygomatic suture reference line. Results: In angular measurement, average occlusal canting change was $3.09^{\circ}$ and standard deviation was $1.05^{\circ}$, average lip canting change was $1.56^{\circ}$ and standard deviation was $1.05^{\circ}$. In linear measurement, average occlusal canting change was 2.41mm and standard deviation was 2.75mm, average lip canting change was 1.18mm and standard deviation was 0.43mm. Lip canting correction ration to occlusal canting correction was 51.5(${\pm}8.4$)% in angular measurement and 48.8(${\pm}9.1$)% in linear measurement. Under Pearson's correlation analysis, Pearson's correlation coefficient was 0.869 in angular measurement and 0.887 in linear measurement(p-value < 0.01). High correlationship was shown between occlusal canting change and lip canting change. Conclusion: First, Bimaxillary orthognathic surgery can correct lip canting as well as occlusal canting. Second, The average amount of lip canting correction is $51.5{\pm}8.4%,\;48.8{\pm}9.1%$ of occlusal canting correction in the study.

Evaluation of Dose Distribution Using a Radiophotoluminescence Glass Dosimeter in Biobeam8000 Gamma Irradiation Device (유리선량계를 이용한 Biobeam8000 감마선 조사장치의 선량평가)

  • Shin, Sang-Hun;Lee, Sung-Hyun;Son, Ki-Hong;Lee, Hyun-Ho;Kim, Kum-Bae;Jung, Hai-Jo;Ji, Young-Hoon
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.198-205
    • /
    • 2011
  • Gamma irradiator is widely used for cell, animal experiment, irradiation for blood, dose measurement, and education. Biobeam8000 gamma irradiator (STS Steuerungstechnik &. Strahlenschutz GmbH, Braunschweig, Germany, Cs137, 81.4 TBq) that KIRAMS (Korea Institute of Radiological and Medical Science) has is a irradiation device that enables to be used in large-capacity of 7.5 L and extensive area. Cs-137 source moves range of 24 cm back-and-forth in a regular cycle in beaker for uniform irradiation and a beaker that puts a specimen like existing radiation irradiator such as Gammacell3000 rotates $360^{\circ}$ during irradiation. Precise dose information according to the location of radiation source would be needed because of the movement of radiation source, whereas radiation could be uniformly irradiated in comparison with existing gamma irradiator. In this study, dose distribution of the inside beaker located in Biomeam8000 gamma irradiator was measured using glass dosimeter, and dose evaluation and distribution regarding dose linearity and dose reproducibility were implemented based on measurement results. This aims to show guideline for efficient use of irradiator based on measurement result when doing experiment or radiation exposure.

The correlation of bone probing, radiographic and histometric measurements (골탐침과 방사선학적 및 조직학적 계측의 상관관계)

  • Hwang, Sung-Joon;Kim, Chang-Sung;Lee, Doug-Youn;Lee, Yong-Keun;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.4
    • /
    • pp.615-624
    • /
    • 2003
  • The most accurate method to assess bone level is the histometric measurement. However it causes discomfort in patients and damage to the regenerated tissues. in the present study, we used 4 type regenerative therapies, The present study evaluated the clinical reliability and accuracy of bone probing measurements and radiographic bone level in the assessment of bone level by comparing those results with histometric confirmed bone level. Twentyfour(24) intrabony defects(4${\times}$4mm 1-wall intrabony defects) were surgically created in the mandibular second and fourth premolars of 6 beagle dogs. The control group underwent a conventional flap operation. Experimental group I was treated with calcium phosphate glass only, and while experimental group 2 was treated with GTR and experimental group 3 was treated with calcium phosphate glass and GTR. The subjects were sacrificed 8 weeks after the operation and a bone probing measurements, radiographic measurement and histometric measurement was performed. The correlation between bone probing measurements(BP) and histometric measurement(HL), and radiographic measurement(RL) and histometric measurement(HL) were analyzed with Spearman's rank correlation analysis and the statistical significance with respect to the type of regenerative therapies was analyzed with the Kruskal Wallis test. The coefficient of correlation to HL was 0.73 for RL and 0.90 for BP. The type of regenerative therapies had no significant effect on the difference between HL and other measurements. The results of this study suggests that bone probing measurements most closely represents actual bone level. So bone probing measurements may be a good clinical method for assessing the hone level following any type of periodontal regenerative therapies.

A Study on the Calibration of Shape Measurement System Using Digital moire (Digital moire 형상측정 시스템의 보정에 관한 연구)

  • 유원재;김도훈;안재웅;강영준;노형민
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.199-202
    • /
    • 2002
  • Moire topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using digital projection moire topography is very attractive because of its high measuring speed and high sensitivity. In this paper, using different N-bucket algorithm method of digital projection moire topography is tested to measuring object with the 2$\pi$-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding measurement errors that decreased more by using the flour-three step algorithm method than the same step in the phase shifting of different pitchs.

  • PDF

Development of Measurement System of Public Strength for Physical Fitness (체격 및 체력층정을 위한 국민체력 층정시스템의 개발)

  • 한영환;이응혁
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.1
    • /
    • pp.85-94
    • /
    • 1995
  • We have developed MSPF (measurement system for physical fitness) which measures physical strength and body dimensions. This system has two main features, one is an automatic measurement of physical fitness, and the other is reducement of reading and writing errors caused by human during measurement. Using the MSPF, total ten items can be measured such as weight, height, sit up, push up,. etc. Since the system which have objectification and high precision has been needed, we used a memory card. By using this, it was easy to save and archive data by computer.

  • PDF