• Title/Summary/Keyword: Medical laser

Search Result 721, Processing Time 0.023 seconds

In-vitro Study on Hemorheological Behaviors of Blood Flow Through a Micro Tube (미세튜브 내부를 흐르는 혈액유동의 유변학적 특성에 대한 in-vitro 연구)

  • Kang, Myung-Jin;Ji, Ho-Seong
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.99-105
    • /
    • 2010
  • In order to obtain velocity profile of blood flow with high spatial resolution, a micro PIV technique consisted of a fluorescent microscope, double-pulsed YAG laser, cooled CCD camera was applied to in-vitro blood flow experiment through a micro round tube of a diameter $100{\mu}m$. Velocity distributions of blood flow for rabbit were obtained. The viscosity profiles for shear rate were found at flowing condition. To provide hemorheological characteristics of blood flow, the viscosities for shear rate were evaluated. The viscosity of blood also steeply increase by decreasing shear rate resulting in Non-Newtonian flow, especially in low shear rate region caused by RBC rheological properties. The results show typical characteristics of Non-Newtonian characteristics from the results of velocity profile and viscosity for blood flow. From the inflection points, cell free layer and two-phase flow consisted with plasma and suspensions including RBCs can be separated.

Two Cases of Stroke in Childhood (소아(小兒) 중풍(中風) 환자(患者) 2례(例)에 대(對)한 증례(證例))

  • Lee, Jin-Yong;Kim, Deog-Gon;Shin, Dong-Gil
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.17 no.1
    • /
    • pp.87-97
    • /
    • 2003
  • Cerebrovascular disease in children is more common than once recognized and the etiology and prognosis of the disease in children are quite different from those of adults. In Korea, the most common cause of stroke is moyamoya disease in ischemic stroke, arteriovenous malformation in hemorrhagic stroke. We experienced two cases of ischemic stroke in childhood whose symptoms are similar to that of adults. They had cerebrovascular malformation(narrowing of ICA, MCA, basilar artery). we treated them with herb medicine, acupuncture treatment, laser acupuncture treatment and physical treatment. After treatment, they recovered from the stroke symptoms, but the primary cause of stroke was not eliminated, so it is thought that more follow up is needed. We report that we had good effects of oriental medical treatment on two case of cerebral infarction in children.

  • PDF

The distribution of Hyperlipemia and sequential changes of serum lipid levels to cerebral vascular accident (뇌졸중(腦卒中) 환자(患者)에 있어 고지혈증(高脂血症)의 분포(分布) 및 혈중지질(血中脂質)의 경시적(經時的) 변화(變化))

  • Jeon, Sang-Yun;Gang, Hwa-Jeong;Hong, Seok;Jeong, Yeong-Hae
    • The Journal of Internal Korean Medicine
    • /
    • v.19 no.2
    • /
    • pp.60-80
    • /
    • 1998
  • In 123 examples of admission patients at Dongshin university oriental medical hospital circulatory internal medicine, we sequently investigated serum lipid, at admission state, 2th and 4th weeks. The results were as follows; 1. In the case of 123 stroke patients, only 12cases were related to Hyperlipemia. So stroke was not related to Hyperlipemia significantly. 2. According to sex, woman has more significant results in the T-cholesterol and LDL-cholesterol. 3. According to the living Zone, Triglyceride of the city zone group washigher than that of the contryside zone significantly. 4. According to the history of drinking and smoke, the patients who have the history of drinking and smoke had a significant remark in T-cholesterol and LDL-cholesterol. 5. In the case of patients like eating meat, it was significant gain of HDL-cholesterol. 6. In the patients who had past history of Hypertension, the value of Triglyceride is significantly low, and sequently as blood pressure decreased, serum lipid value decreased too. 7. In the patients who had past history of D.M., the value of Triglyceride is significantly high, and sequently as blood sugar value decreased, serum lipid value decreased too. 8. In the case of patients treated He-Ne laser, Triglyceride was decreased significantly. 9. In the case of treating the stroke patients, serum lipid had non-significant decrease value.

  • PDF

SELDI-TOF MS Combined with Magnetic Beads for Detecting Serum Protein Biomarkers and Establishment of a Boosting Decision Tree Model for Diagnosis of Pancreatic Cancer

  • Qian, Jing-Yi;Mou, Si-Hua;Liu, Chi-Bo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.1911-1915
    • /
    • 2012
  • Aim: New technologies for the early detection of pancreatic cancer (PC) are urgently needed. The aim of the present study was to screen for the potential protein biomarkers in serum using proteomic fingerprint technology. Methods: Magnetic beads combined with surface-enhanced laser desorption/ionization (SELDI) TOF MS were used to profile and compare the protein spectra of serum samples from 85 patients with pancreatic cancer, 50 patients with acute-on-chronic pancreatitis and 98 healthy blood donors. Proteomic patterns associated with pancreatic cancer were identified with Biomarker Patterns Software. Results: A total of 37 differential m/z peaks were identified that were related to PC (P < 0.01). A tree model of biomarkers was constructed with the software based on the three biomarkers (7762 Da, 8560 Da, 11654 Da), this showing excellent separation between pancreatic cancer and non-cancer., with a sensitivity of 93.3% and a specificity of 95.6%. Blind test data showed a sensitivity of 88% and a specificity of 91.4%. Conclusions: The results suggested that serum biomarkers for pancreatic cancer can be detected using SELDI-TOF-MS combined with magnetic beads. Application of combined biomarkers may provide a powerful and reliable diagnostic method for pancreatic cancer with a high sensitivity and specificity.

Simulation and evaluation of fiber optics for hand-piece using ray tracing method (광선추적법을 이용한 핸드피스용 광섬유 광학계 시뮬레이션 및 특성 평가)

  • Park, J.H.;Kim, H.;Yang, B.C.;Lee, B.H.;Yoo, Y.J.;Kim, D.W.;Lee, C.W.;Lee, C.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1962-1963
    • /
    • 2002
  • The hand-piece fiber optics is applied to medical appliances such as glaucoma theraphy to focus semiconductor laser on the affected parts efficiently. In this paper, we evaluate optical properties such as beam power and radius of a hand-piece probe by experiments and we also simulate the hand-piece optics by ray tracing method in order to study major parameters to optimize focalization ability. As results, we show experimental and simulation results of the hand-piece optics and also summarize several requirements that have to be considered in optimizing the hand-piece optics.

  • PDF

Study of the capability of metallic coils immersed with protein solution as embolic masterials (색전용 금속 코일 개발과 단백질 처리 후 혈전성에 대한 연구)

  • Lee, Y.S.;Kim, T.S.;Kim, H.C.;Shin, K.M.;Park, J.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.347-349
    • /
    • 1997
  • In this study, we designed a vascular occlusion device based on the principle that slowing blood flow would induce thrombosis. Tungsten, stainless steel and platinum were tested for finding a good embolic metallic coil. The primary coil and the second coil were done with heat treatment or different time. The pitch distance and the shape retention capability of second coil were characterized by SEM. To increase thrombogenicity, we tried to treat different proteins on steel coils: thrombin, gelatin and both gelatin and thrombin. To verify protein materials treated on coils, the surface of coil treated with different proteins were characterized using Laser Raman Spectrophotometer. After observation of embolic coils, the peptides bonds on theirs' surface were found. In order to compare the thrombogenicity of different embolic agents, we measured whole blood clotting time.

  • PDF

Handheld OCT probe for Evaluation of Tympanic Membrane Status (OCT용 손잡이 형 프로브를 이용한 고막 상태 평가)

  • Kwon, Hyeong-Il;Kim, Yee-Hyuk;Cho, Nam-Hyun;Jeong, Hyo-Sang;Kim, Jee-Hyun;Lee, Sang-Heun
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.4
    • /
    • pp.285-288
    • /
    • 2011
  • In this study, we developed an optical coherence tomography(OCT) using a sweep-source laser whose center wavelength is 1310 nm and a probe of hand-held type. The developed hand-held probe targets to diagnose the middle ear, so it is miniaturized for ease and convenience of control. For the first time, we performed in-vivo clinical experiments on tympanic membrane(TM) perforation patients not reported from previous studies about OCT. The high-resolution sectional images of tympanic membrane perforation can be obtained. There aren't many studies about diagnostic instrument of the middle ear and diagnosis with sectional image of the middle ear, so the developed OCT system and hand-held probe are applicable to tympanic membrane perforation and other pathologic diagnosis in the middle ear.

PIV measurement of oscillatory flow in a micro-channel as a bronchiole model

  • LEE Won-je;KAWAHASHI Massaki;HIRAHARA Hiroyuki
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.125-134
    • /
    • 2004
  • The improvement of artificial respiration method has brought about the decrease in mortality of pulmonary diseases patients. Various respiratory curative methods, inclusive of HFOV (High Frequency Oscillatory Ventilation), have been developed for more effectual and less harmful management of acute respiratory failure. However, the mechanism of gas transfer and diffusion in a bronchiole has not yet been clarified in detail. As a first approach to the problem, we measured oscillatory flows in a Y-shaped micro-channels as bronchiole model by micro Particle Image Velocimetry(micro PIV). In order to establish the fundamental technique of PIV measurements on oscillatory air flow in a micro-channel, we used about 500-nm-diameter incense smoke particles, a diode laser, a high speed camera including an objective lens, and a HFOV, which is effective technique for medical care of pulmonary disease patients, especially, infants. The bronchiole model size is that parent tube is $500\{mu}m$ width and $500\{mu}m$ depth, and daughter tubes are $450\{mu}m$ width and $500\{mu}m$ depth. From this study made on the phenomenon of fluid in micro size bronchus branch of a lung, we succeeded to get time series velocity distribution in a micro scale bronchial mode. The experimental results of velocity distribution changing with time obtained by micro PIV can give fundamental knowledge on oscillatory airflow in micro-channel.

  • PDF

Transport Properties of Conversion Materials for Digital Radiography

  • Kim, Jae-Hyung;Park, Chang-Hee;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.6
    • /
    • pp.250-254
    • /
    • 2007
  • Applying the moving photo-carrier grating(MPG) technique and time-of-flight(TOF) measurements, we studied the transport properties of stabilized amorphous selenium typical of the material used in direct conversion X-ray imaging devices. For MPG measurement, we obtained electron and hole mobility and the recombination lifetime of $\alpha-Se$ films with arsenic(As) additions. We found an apparent increase in hole drift mobility and recombination lifetime, especially when 0.3 % As was added into $\alpha-Se$ film, whereas electron mobility decreased with the addition of As due to the defect density. For TOF measurement, a laser beam with pulse duration of 5 ns and wavelength of 350 nm was illuminated on the surface of $\alpha-Se$ with a thickness of 400 ${\mu}m$. The measured hole and electron transit times were about 8.73 ${\mu}s$ and 229.17 ${\mu}s$, respectively.

Development of FK506-hyperproducing strain and optimization of culture conditions in solid-state fermentation for the hyper-production of FK506

  • Mo, SangJoon;Yang, Hyeong Seok
    • Journal of Applied Biological Chemistry
    • /
    • v.59 no.4
    • /
    • pp.289-298
    • /
    • 2016
  • FK506 hyper-yielding mutant, called the TCM8594 strain, was made from Streptomyces tsukubaensis NRRL 18488 by mutagenesis using N-methyl-N'-nitro-N-nitrosoguanidine, ultraviolet irradiation, and FK506 sequential resistance selection. FK506 production by the TCM8594 strain improved 45.1-fold ($505.4{\mu}g/mL$) compared to that of S. tsukubaensis NRRL 18488 ($11.2{\mu}g/mL$). Among the five substrates, wheat bran was selected as the best solid substrate to produce optimum quantities of FK506 ($382.7{\mu}g/g$ substrate) under solid-state fermentation, and the process parameters affecting FK506 production were optimized. Maximum FK506 yield ($897.4{\mu}g/g$ substrate) was achieved by optimizing process parameters, such as wheat bran with 5 % (w/w) dextrin and yeast extract as additional nutrients, 70 % (v/w) initial solid substrate moisture content, initial medium pH of 7.2, $30^{\circ}C$ incubation temperature, inoculum level that was 10 % (v/w) of the cell mass equivalent, and a 10 day incubation. The results showed an overall 234 % increase in FK506 production after optimizing the process parameters.