A Study on the Architectural Planning of the Angiography Unit in General Hospital (종합병원 혈관조영촬영유니트의 건축계획에 관한 연구)

  • Yun, Woo-Yong;Chai, Choul-Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.12 no.2
    • /
    • pp.69-77
    • /
    • 2006
  • Angiography means that a check up to know an abnormal condition in all the blood vessels include from the heart, aortae, cerobrovascular and abdonominal artery to hands and feet. Main examples of this are cerebral angiography, abdominal, liver for urinary anomaly, renovascular angiography, and artery and vein in arms and legs. Angiography uses radial rays or angiography equipment for an image output during interventional procedure and compositive diagnosis. The acts which performed in a projection room have changed drastically. In general, it is performed by using equipment which is attached one or two C-arms and the method of inserting catheter in vein after anesthesia. For this reason, some rooms that consist of angiography room units should be planned not only for expensiveness equipment and facilities also to be germ-free. Nowadays, in the angiography unit case, it is placed independently as the central part of many hospitals. It does not belong to the imaging medical department any more as considering raising filming times and the relation between C.C.U.(coronary care unit) and operation unit. This means the acts performed are diversified and well-organized rooms in support of diagnosis are required. However, it is difficult to plan the angiography room unit due to domestic researches and data on this unit are not enough. Therefore, this study aims at bringing up basic issue for architectural planning of the angiography unit in general hospital.

  • PDF

A Study on a Long-term Demand Forecasting and Characterization of Diffusion Process for Medical Equipments based on Diffusion Model (확산 모형에 의한 고가 의료기기의 수요 확산의 특성분석 및 중장기 수요예측에 관한 연구)

  • Hong, Jung-Sik;Kim, Tae-Gu;Lim, Dar-Oh
    • Health Policy and Management
    • /
    • v.18 no.4
    • /
    • pp.85-110
    • /
    • 2008
  • In this study, we explore the long-term demand forecasting of high-price medical equipments based on logistic and Bass diffusion model. We analyze the specific pattern of each equipment's diffusion curve by interpreting the parameter estimates of Bass diffusion model. Our findings are as follows. First, ultrasonic imaging system, CT are in the stage of maturity and so, the future demands of them are not too large. Second, medical image processing unit is between growth stage and maturity stage and so, the demand is expected to increase considerably for two or three years. Third, MRI is in the stage of take-off and Mammmography X-ray system is in the stage of maturity but, estimates of the potential number of adopters based on logistic model is considerably different to that based on Bass diffusion model. It means that additional data for these two equipments should be collected and analyzed to obtain the reliable estimates of their demands. Fourth, medical image processing unit have the largest q value. It means that the word-of-mouth effect is important in the diffusion of this equipment. Fifth, for MRI and Ultrasonic system, q/p values have the relatively large value. It means that collective power has an important role in adopting these two equipments.

Evaluation of the Resolution Characteristics by Using ATS 535H Phantom for Ultrasound Medical Imaging (초음파 의료영상에서 ATS 535H 팬텀을 이용한 해상력 특성 평가)

  • Jung-Whan, Min;Hoi-Woun, Jeong;Hea-Kyung, Kang
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.15-21
    • /
    • 2023
  • This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.

The Evaluation about the Information Fidelity in the External Image Information Input - Using DICOM Validation Tool - (외부영상정보 입력 시 DICOM정보 충실성에 대한 평가 - DICOM Validation Tool 이용 -)

  • Lee, Song-Woo;Lee, Ho-Yeon;Do, Ji-Hoon;Jang, Hye-Won
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.33-38
    • /
    • 2011
  • Now a days, there's many change over for PACS among the most of hospital and it standard for DICOM 3.0. These kind of using of DICOM 3.0 improves increasing of medical imaging exchange and service for patient. However, there's some problems of compatibility caused during carry out CD and DVD from hospital. For this reason, this thesis analyzed patients image targeting those storages requested to hospitals in Seoul by using Validation Toolkit which is recommended from KFDA. The analyze type is like this. Make 100 data, total 500, each of MRI CT Plain x-ray Ultrasound PET-CT images and analyzed type of error occurred and loyalty of information. If express percentage of error occurred statistically, we can get a result as follows MRI 5%, Plain x-ray 11%, CT 18%, US 25%, PET-CT 30%. The reson why percentage of error occurred in PET-CT is because of imperfective support and we could notice that we weren't devoted to information. Even though, PET-CT showed highest percentage of error occurred, currently DICOM data improved a lot compare to past. Moreover, it should be devoted to rule of IHE TOOL or DICOM. In conclusion, we can help radiographer to analyze information of image by providing clues for solving primary problem and further more, each of PACS company or equipment company can enhance fidelity for following standard of image information through realizing the actual problem during transfer of image information.

  • PDF

Effect of Temperature on T1 and T2 Relaxation Time in 3.0T MRI (3.0T MRI에서 온도변화가 T1 및 T2 이완시간에 미치는 영향)

  • Kim, Ho-Hyun;Kwon, Soon-Yong;Lim, Woo-Teak;Kang, Chung-Hwan;Kim, Kyung-Soo;Kim, Soon-Bae;Baek, Moon-Young
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.63-68
    • /
    • 2013
  • Purpose : The relaxation times of tissue in MRI depend on strength of magnetic field, morphology of nuclear, viscosity, size of molecules and temperature. This study intended to analyze quantitatively that materials' temperatures have effects on T1 and T2 relaxation times without changing of other conditions. Materials and Methods : The equipment was used MAGNETOM SKYRA of 3.0T(SIEMENS, Erlagen, Germany), 32 channel spine coil and Gd-DTPA water concentration phantom. To find out T1 relaxation time, Inversion Recovery Spin Echo sequences were used at 50, 400, 1100, 2500 ms of TI. To find out T2 relaxation time, Multi Echo Spin Echo sequences were used at 30, 60, 90, 120, 150, 180, 210, 240, 270 ms of TE. This experiment was scanned with 5 steps from 25 to $45^{\circ}C$. next, using MRmap(Messroghli, BMC Medical Imaging, 2012) T1 and T2 relaxation times were mapped. on the Piview STAR v5.0(Infinitt, Seoul, Korea) 5 steps were measured as the same ROI, and then mean values were calculated. Correlation between the temperatures and relaxation times were analyzed by SPSS(version 17.0, Chicago, IL, USA). Results : According to increase of temperatures, T1 relaxation times were $214.39{\pm}0.25$, $236.02{\pm}0.87$, $267.47{\pm}0.48$, $299.44{\pm}0.64$, $330.19{\pm}1.72$ ms. T2 relaxation times were $180.17{\pm}0.27$, $197.17{\pm}0.44$, $217.92{\pm}0.39$, $239.89{\pm}0.53$, $257.40{\pm}1.77$ ms. With the correlation analysis, the correlation coefficients of T1 and T2 relaxation times were statistically significant at 0.998 and 0.999 (p< 0.05). Conclusion : T1 and T2 relaxation times are increased as temperature of tissue goes up. In conclusion, we suggest to recognize errors of relaxation time caused local temperature's differences, and consider external factors as well in the quantitative analysis of relaxation time or clinical tests.

  • PDF

Design and Implementation of Medical Information System using QR Code (QR 코드를 이용한 의료정보 시스템 설계 및 구현)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • The new medical device technologies for bio-signal information and medical information which developed in various forms have been increasing. Information gathering techniques and the increasing of the bio-signal information device are being used as the main information of the medical service in everyday life. Hence, there is increasing in utilization of the various bio-signals, but it has a problem that does not account for security reasons. Furthermore, the medical image information and bio-signal of the patient in medical field is generated by the individual device, that make the situation cannot be managed and integrated. In order to solve that problem, in this paper we integrated the QR code signal associated with the medial image information including the finding of the doctor and the bio-signal information. bio-signal. System implementation environment for medical imaging devices and bio-signal acquisition was configured through bio-signal measurement, smart device and PC. For the ROI extraction of bio-signal and the receiving of image information that transfer from the medical equipment or bio-signal measurement, .NET Framework was used to operate the QR server module on Window Server 2008 operating system. The main function of the QR server module is to parse the DICOM file generated from the medical imaging device and extract the identified ROI information to store and manage in the database. Additionally, EMR, patient health information such as OCS, extracted ROI information needed for basic information and emergency situation is managed by QR code. QR code and ROI management and the bio-signal information file also store and manage depending on the size of receiving the bio-singnal information case with a PID (patient identification) to be used by the bio-signal device. If the receiving of information is not less than the maximum size to be converted into a QR code, the QR code and the URL information can access the bio-signal information through the server. Likewise, .Net Framework is installed to provide the information in the form of the QR code, so the client can check and find the relevant information through PC and android-based smart device. Finally, the existing medical imaging information, bio-signal information and the health information of the patient are integrated over the result of executing the application service in order to provide a medical information service which is suitable in medical field.

Study on Radiation dose in according to Magnification's rate in fluoroscopy (투시 조영 검사 시 확대율에 따른 피폭선량에 관한 고찰)

  • Kang, Kyeong-Mi;Hong, Seon-Sook;Seong, Min-Sook;Song, Woon Heung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.39-44
    • /
    • 2013
  • Purpose : The purpose of this study is the magnification rates depending on the area of patient dose (DAP) and glass dosimeter see the change of the dose according to the dose characteristics of low-magnification aims to raise standards. Materials and Method : Direct DR equipment Sonialvision DAR-8000f, Shimadzu was used, the patient entrance dose measurements to the surface of the Rando Phantom of the neck and the abdomen was placed on the Xi unfors. glass dosimeter for measuring organ doses at the same time the Rando Phantom of the major organs in place by inserting a 9 ", 12", 15 ", 17" and 30 seconds for each magnification were measured according in fluoroscopy. DAP meter area of the patient dose was measured. Result : Esophagography at 17" 143% than 9"magnification the average area dose was increased. Organ dose of Esophagography at 17" was decreased 25.32% than 9" magnification. UGI at 17" was increased 129.73% DAP than 9" magnification. Organ dose of UGI at 17" was decreased 23.32% than 9" magnification. Where the major organs of magnification at 17" were decreased(lung -25.96%, stomach -33.09%, spleen -27.81%, liver -4.92%) than 9" magnification. Conclusion : Expected to get better quality image While using the proper magnification, and have recognition that difference Organ doses and DAP meter in fluoroscopy.

  • PDF

Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy (복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구)

  • Hong, Seon Sook;Kang, Kyeong Mi;Seong, Min Suk;Lee, Jong Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

Survey on Utilization of Ultrasonographic Machine in Small Animal Clinics in South Korea (전국 소동물 병원의 초음파 진단기기 및 활용도 현황조사)

  • Chang, Jin-Hwa;Paik, Min-Ji;Chang, Dong-Woo
    • Journal of Veterinary Clinics
    • /
    • v.28 no.4
    • /
    • pp.408-414
    • /
    • 2011
  • This study was carried out to analyze the utilization of ultrasound machines in animal hospitals and focused on surveying the present condition of diagnostic ultrasound on veterinary medicine in South Korea. Total 279 veterinary hospitals were surveyed with e-mail questionnaires or telephone survey. E-mail questionnaires consist of 17 items of questions including existence of ultrasound machine, types of ultrasound machine, ultrasound examination costs, frequency, purposes, other diagnostic imaging equipments, and referring system of ultrasound. Telephone surveys asked about the existence of the ultrasound machine and types of the ultrasound machine to 279 animal hospitals. Two hundred and seventy-one out of 279 animal hospitals holds ultrasound machine. Seventy-two percents clinics purchased used ultrasonographic machines and mean years after the date of manufacture is 7.5 years and the proportion of superannuated machines are relatively high. Also many clinicians prefer single organ scanning rather than general scan technique and more than 60% of clinics perform ultrasonographic examination less than 5 times a week. Clinics located in Seoul area tend to have more expensive and brand-new ultrasonographic machines and the distribution of radiology specialist are higher in this area. Problems associated with the present condition were oversupply of machines, unequal distribution of the medical equipment in different localities, ineffective use of the medical equipment, and high percentage of old poor-quality medical equipments. There should be a viable alternative proposal to control amount and quality of the ultrasound machines. Also, the improved management system for the ultrasound machine is required.

A low noise, wideband signal receiver for photoacoustic microscopy (광음향 현미경 영상을 위한 저잡음 광대역 수신 시스템)

  • Han, Wonkook;Moon, Ju-Young;Park, Sunghun;Chang, Jin Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.507-517
    • /
    • 2022
  • The PhotoAcoustic Microscopy (PAM) has been proved to be a useful tool for biological and medical applications due to its high spatial and contrast resolution. PAM is based on transmission of laser pulses and reception of PA signals. Since the strength of PA signals is generally low, not only are high-performance optical and acoustic modules required, but high-performance electronics for imaging are also particularly needed for high-quality PAM imaging. Most PAM systems are implemented with a combination of several pieces of equipment commercially available to receive, amplify, enhance, and digitize PA signals. To this end, PAM systems are inevitably bulky and not optimal because general purpose equipment is used. This paper reports a PA signal receiving system recently developed to attain the capability of improved Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of PAM images; the main module of this system is a low noise, wideband signal receiver that consists of two low-noise amplifiers, two variable gain amplifiers, analog filters, an Analog to Digital Converter (ADC), and control logic. From phantom imaging experiments, it was found that the developed system can improve SNR by 6.7 dB and CNR by 3 dB, compared to a combination of several pieces of commercially available equipment.