• Title/Summary/Keyword: Medical image equipment

Search Result 177, Processing Time 0.026 seconds

A development of Intelligent Parking Control System Using Sensor-based on Arduino

  • LIM, Myung-Jae;JUNG, Dong-Kun;KWON, Young-Man
    • Korean Journal of Artificial Intelligence
    • /
    • v.9 no.2
    • /
    • pp.29-34
    • /
    • 2021
  • In this paper, for efficient parking control, in an Arduino environment, an intelligent parking control prototype was implemented to provide parking control and parking guidance information using HC-SR2O4 and RC522. The main elements of intelligent parking control are vehicle recognition sensors, parking control facilities, and integrated operating software. Whether the vehicle is parked on the parking surface may be confirmed through sensor or intelligent camera image analysis. Parking control equipment products include parking guidance and parking available display devices, vehicle number recognition cameras, and intelligent parking assistance systems. This paper applies and implements ultrasonic sensors and RFID concepts based on Arduino, recognizes registered vehicles, and displays empty spaces. When a vehicle enters a parking space to handle this function, the automatic parking management system distinguishes the registered vehicle from the external vehicle through the RC522 sensor. In addition, after checking whether the parking slot is empty, the HC-SR204 sensor is displayed through the LED so that the driver can visually check it. RFID is designed to check the parking status of the server in real time and provide the driver with optimal route service to the parking slot.

Quantitative and Qualitative Evaluation according to Radiation Dose Conditions when using MAR function in Implant examination from Cone Beam CT (ConeBeam CT로 임플란트 검사 시 MAR 기능 유무와 선량조건에 따른 정량적 및 정성적 평가)

  • Hyun-Jun, Ahn;Sang-Hyun, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.905-917
    • /
    • 2022
  • This study was conducted to evaluate the use of the MAR function and the image quality of the image when examining with each radiation dose. A simple Periapical phantom was made to set up an implant, and images were obtained and analyzed according to the presence or absence of MAR function for each radiation dose using CBCT equipment. In this study, MEAN, SNR, and CNR values were obtained using the Image J program, and through statistical analysis, images were the most quantitative and suitable values when the Abutment of Implant was 100 kVp and 8 mA, and when the Center of Implant and Apex of Implant were 100 kVp and 9 mA. As a result, it was confirmed that if the radiation dose increased, the Pixel Value, SNR, and CNR values of the image rose up so that the quality of the image improved, and using the MAR function reduced artifacts.

Evaluation of Image Quality using ATS-539 Phantom and SNR in the Ultrasonographic Equipment (ATS-539 다목적 팬텀과 SNR을 이용한 초음파 영상평가)

  • Kim, Min-Ju;Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.284-291
    • /
    • 2013
  • The importance of ultrasound examination in the field of medical imaging has been emphasized and the interest in sonographic image evaluation is growing. However image evaluations by the non-standardized criteria and methods, so establishment of legal provisions and objective evaluation criteria are needed. In this study, we used SNR to find out more quantitative way and supplement the limitations of the existing phantom image evaluation. The results of acquired 8 images using ATS-539 multipurpose phantom were compared in SNR of sensitivity and gray-scale dynamic range. In the result of the experiment, excellent equipment of existing phantom images are G1, S1 and G2 in regular sequence. In SNR of sensitivity, G1, S1 and G2 and in SNR of gray-scale dynamic range, S1 G1 and G2 in order. In the conclusion, all the experiment results did not show big difference and regular pattern neither. Therefore, the new evaluation measures should be used with the existing phantom image evaluation method for more objective and quantitative evaluation of the ultrasound imaging device.

The Influence of the Change of Patient Radiation Exposure Dose Distribution on the Grid Condition and Detector Acquisition Dose on the Exposure Distance in the Use of Amorphous Silicon Thin Film Transistor Detector with AEC (자동노출제어장치를 이용한 비정질 실리콘 평판형 검출기에서 격자의 조건에 따른 환자선량 변화와 촬영 거리의 변화가 검출기 획득선량에 미치는 영향)

  • Yoon, Seok-Hwan;Choi, Jun-Gu;Han, Dong-Kyoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.23-30
    • /
    • 2007
  • This study attempts to propose an appropriate method of using digital medical imaging equipments, by studying the effects of automatic exposure control(AEC), grid ratio and the change of radiography distance on the patient dose and detertor acquisition dose during the procedure of acquiring image through a digital medical imaging detector. The change of dose following the change of grid ratio's exposure and radiography distance was measured, by using an abdominal phantom organized with tissue equivalent materials in an amorphous silicon thin film transistor detecter installed with AWC. The case to use grid ratio 12 : 1, focal distance 180cm to radiography distance 110cm in AEC, the patient dose increased rather when we used grid ration 10 : 1, focal distance 110cm. When AEC was not used,the dose necessary for image acquisition decreased as the grid ratio became higher and the distance became further. but detector acquisition dose was not reduced when in applied AEC. When purchasing digiral medical imaging equipments, optional items such as AEC and grid shall be accurately selected to satisfy the use of the equipments. Radiography error made by radiation technologist and unnenessary patient dose can be reduced by selecting equipments with a radiography distance marker equipment when it did not apply AEC. These equipments can also be helpful in maintaining high imaging quality, one of the merits of digital detectors.

  • PDF

X-선 발생장치 정류방식에 따른 출력특성에 관한 연구

  • Na, Gil-Ju;Baek, Su-Ung;Yang, Hyeon-Hun;Park, Gye-Chun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.126-126
    • /
    • 2009
  • X-ray high-voltage generator is the most important part that can decide the radiation exposure dose affecting a patient or operator according to the characteristic. If decrease of X-ray radiation exposure dose and output characteristic of high-voltage generator is unstable, a patient or operator must be exposed to more radiation. This study measures and analyzes the exposure dose reproducibility and output characteristic according to a change of tube current on the various rectification methods of diagnostic X-ray equipment. It can find that quality bastardize and output is increased if voltage of X-ray tube is increased. Exposure dose reproducibility according to output of X-ray equipment is extremely excellent in inverter type, and is stable in order of following three-phase, a single-phase and condenser method. This study can find that the reply incidence of high-voltage generator is generated due to difference in rectification method, noise occurs in X-ray due to that, quality of an image is decreased due to that, and medical diagnosis can be failed due to that.

  • PDF

Feasibility for Ultrasound Pad Material for the Evaluation Axillary Region of Automated Breast Ultrasound Equipment (자동유방초음파 장비의 액와부 평가를 위한 초음파 패드 물질의 타당성)

  • Seo, Eun-Hee;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.231-240
    • /
    • 2018
  • Automated breast ultrasound (ABUS) equipment is a new innovative technique for 3D automatic breast scanning, but limited for the examination in the concave axillary region. The purpose of this study was to determine feasible candidate materials for the ultrasonic wave propagation media in ABUS, enabling the evaluation of the axillary region. Ultrasonography was performed using an ABUS system ($Invenia^{TM}ABUS$, GE, USA) on the ultrasound-specific phantom (UC-551M-0.5, ATS Laboratories, USA) covered by different candidate materials. The validity of feasible candidate materials was evaluated by image quality. Three independent radiological technologists, with more than 10 years of experience, visually assessed on the images. The inter-observer agreements according to the candidate materials were tested using Cronbach's alpha. Unenveloped solidified carrageenan can be a feasible material for the use of ABUS with excellent test reliability. Therefore, the coverage of the axillary region with carrageenan may be effective for ABUS which was originally developed for the convex anatomic structure as female breast.

About dentistry infection from dentistry medical institution recognition research of patient (치과내원환자의 감염관리에 관한 인식도 조사)

  • Lee, Youn-Kyung;Kim, Soon-Duck
    • Journal of Korean society of Dental Hygiene
    • /
    • v.10 no.4
    • /
    • pp.617-625
    • /
    • 2010
  • Objectives : The research which sees collected information about dentistry infection management recognition of the patients and the infection management which the medical treatment consumer does in necessity is what, grasped and satisfaction and became the fundamental data which makes the hospital will be able to trust about dentistry image rise and dentistry environment of the medical treatment consumer who assists a dentistry character executed. Methods : From 2009 April 1st until May 28th 233 people common people who have the experience which visits a Gyeongsangnam-do area dentistry the object with the entry question law which sleeps did and the data analysis SPSS, 12.0 For Window under using produced each question item by frequency and a ratio, the analytical degree of infection management One - Way ANOVA stamps and executed t-test. Results : Information experience experienced about dentistry infection of the investigation object person to be, appeared with 74.7% and the after that dentistry assistance at the time of conduct change which experiences the answer back regarding of Former times attentively observes organization disinfecting' was most with 46.6%. The protective equipments wearing goal of the dentistry medical attendance appeared the dentistry medical attendance and patient protection 77.7%, dentistry medical attendance protection 12.9%, by patient protection 9.4% order. Before medical treatment starting of the dentistry medical attendance the hand Does not confirm' appeared 72.1%, with. The hand washing, is whole and the degree which appears is high with 4.11 points the stamp. Is high there was a possibility of knowing the thing about the recording infection where the educational background will be high and considers statistically the difference which was visible Conclusions : The education which is active and continuous is necessary about infection management and sets the guides which are standardized to the patients and about infection management and about infection prevention and exposes from dentistry practices well to emboss the thing is thought that there is a necessity to plant a trust feeling about the dentistry where the patients assist.

Evaluation of HalcyonTM Fast kV CBCT effectiveness in radiation therapy in cervical cancer patients of childbearing age who performed ovarian transposition (난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 난소선량 감소를 위한 HalcyonTM Fast kV CBCT의 유용성 평가 : Phantom study)

  • Lee Sung Jae;Shin Chung Hun;Choi So Young;Lee Dong Hyeong;Yoo Soon Mi;Song Heung Gwon;Yoon In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.73-82
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of reducing the absorbed dose to the ovaries and the quality of the CBCT image when using the HalcyonTM Fast kV CBCT of cervical cancer patients of child-bearing age who performed ovarian transposition Materials and Methods : Contouring of the cervix and ovaries required for measurement was performed on the computed tomography images of the human phantom (Alderson Rando Phantom, USA), and three Optically Stimulated Luminescence Dosimeter(OSLD) were attached to the selected organ cross-section, respectively. In order to measure the absorbed dose to the cervix and ovaries in the TruebeamTM pelvis mode (Hereinafter referred to as TP), The HalcyonTM Pelvis mode (Hereinafter referred to as HP) and The HalcyonTM Pelvis Fast mode (Hereinafter referred to as HPF), An image was taken with a scan range of 17.5 cm and also taken an image that reduced the Scan range to 12.5cm. A total of 10 cumulative doses were summed, It was replaced with a value of 23 Fx, the number of cervical cancer treatments, and compared In additon, uniformity, low contrast visibility, spatial resolution, and geometric distortion were compared and analyzed using Catphan 504 phantom to compare CBCT image quality between equipment. Each factor was repeatedly measured three times, and the average value was obtained by analysing with the Doselab (Mobius Medical Systems, LP. Versions: 6.8) program. Results: As a result of measuring absorbed dose by CBCT with OSLD, TP and HP did not obtain significant results under the same conditions. The mode showing the greatest reduction value was HPF versus TP. In HPF, the absorbed dose was reduced by 39.8% in the cervix and 19.8% in the ovary compared to the TP in the scan range of 17.5 cm. the scan range was reduced to 12.5 cm, absorbed dose was reduced by 34.2% in the cervix and 50.5% in the ovary. In addition, result of evaluating the quality of the image used in the above experiment, it complied with the equipment manufacturer's standards with Geometric Distortion within 1mm (SBRT standard), Uniformity HU, LCV within 2.0%, Spatial Resolution more than 3 lp/mm. Conclusion: According to the results of this experiment, HalcyonTM can select more various conditions than TruebeamTM in treatment of fertility woman who have undergone ovarian Transposition , because it is important to reduce the radiation dose by CBCT during radiation therapy. So finally we recommend HalcyonTM Fast kV CBCT which maintains image quality even at low mAs. However, it is consider that the additional exposure to low doses can be reduced by controlling the imaging range for patients who have undergone ovarian transposition in other treatment machines.

Quality Control and Image Quality Comparison according to Ultrasonic Equipment (초음파 장비에 따른 정도관리와 화질 비교)

  • Dong-Hee, Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.935-942
    • /
    • 2022
  • In doing interventional treatment under the guidance of ultrasonography, the medical team detects the legion site with ultrasonic equipment at first, and insert angio needle. In this situation, if the position of legion and the depth of inserted needle on the ultrasonographic screen are different from real position and depth, the needle is likely to damage a major blood vessel or tissue. Accordingly, we had wondered how much such differences between screen image and reality, and so decided to examine them. Using five ultrasonographic equipments manufactured from different companies in different years, this study tried to compare the lengths of the needle on the screen images and real lengths of it, and find out the factors affecting skewness of them. This study used hog meat chunk to mimic human flesh, and sausages as the target of needle. It compared penetrating depths of the needle as the images on the five equipments using single sample t test in the SPSS 22 statistical program. It was found that all the errors were statistically significant(<.05). So, this study decided that it was wrong to evaluate performances of the equipments by the makers and ages of them. It is necessary to do periodic quality controls of equipments and improve the skillfulness of sonographers to reduce error rates between real treatment areas and the images of them.

A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index (Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구)

  • Kim, Jae-In;Lee, Yang-Sub;Jang, Dong-Soo;Jung, Min-Cheol;Bae, Seung-Ho;Lee, Kwan-Sub;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF