A Preliminary Study for the Development of Diagnostic X-ray Simulator using Visible Light Source (일반광원을 이용한 진단용 X선 모사 실험장치 개발을 위한 예비 연구)

  • 정광호;서태석;이형구;최보영;윤세철
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.169-175
    • /
    • 2002
  • The purpose of this study is to verify the usefulness of X-ray simulator which uses a visible light source for further study. We developed a small experimental equipment which is composed of three main components - source, localizer and detector. Cartesian coordinate was set in 3D space, and the position of target was assumed the origin of the coordinate. The light from the source passes directly through the target, and projection image is formed on the screen, which can be taken with the digital camera. Since projection images were acquired behind the screen, they were flipped over right and left. By examining the characters of visual light source and equipments, it could be concluded that developed system was useful for experimental purpose.

  • PDF

The Evaluation of Image Quality According to the Change of Reconstruction Algorithm of CT Images (재구성 알고리즘 변화에 따른 CT 영상의 화질 평가)

  • Han, Dong-Kyoon;Park, Kun-Jin;Ko, Shin-Kwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • In this study, the correlation among the changes of Modulation Transfer Function(MTF) in the noise and high-contrast resolution and the change of Contrast to noise ratio(CNR) in the low-contrast resolution will be examined to investigate the estimation of image quality according to the type of algorithms. The image data obtained by scanning American Association of Physicists in Medicine(AAPM) phantom was applied to each algorithm and the exposure condition of 120 kVp, 250 mAs, and then the CT number and noise were measured. The MTF curved line of the high-contrast resolution was calculated with Point Spread Function(PSF) by using the analysis program by Philips, resulting in 0.5 MTF, 0.1 MTF and 0.02 MTF respectively. The low-contrast resolution was calculated with CNR and the uniformity was measured to each algorithm. Since the measurement value for the uniformity of the equipment was below ${\pm}$ 5 HU, which is the criterion figure, it was found to belong to the normal range. As the algorithm got closer from soft to edge, the standard deviation of CT number increased, which indicates that the noise increased as well. As for MTF, 0.5 MTF, 0.1 MTF and 0.02 MTF were all sharp algorithms, and as the algorithm got closer from soft to edge, it was possible to distinguish more clearly with the naked eye. On the other hand, CNR gradually decreased, because the difference between the contrast hole CT number and the acrylic CT number was the same while the noise of hole increased.

  • PDF

A Study of Image Characteristics due to Focus-Grid and Head Phantom Decentering from the Armorphos Silicon Thin Film Transistor Detector the Fixed Focus-Grid is Applied (고정식 초점형 격자가 적용된 비정절 실리콘 평판형 검출기에서 초점-격자와 두부 팬텀의 중심 변위에 의한 화질 특성에 관한 연구)

  • Choi, Jun-Gu;Kim, Byeong-Gi;Cha, Seon-Hwa;Kim, Gyeong-Su
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.7-15
    • /
    • 2007
  • This study aim to investigate image characteristics due to focus-grid and head phantom decentering from the armorphos silicon thin film transistor detector the fixed focus-grid is applied, wish to propose right use method of digital medical equipment. Acquired image according to focus-grid and head phantom position decentering using head phantom on armorphos silicon thin film transistor detector the fixed focus-grid is applied. acquired image evaluate pixel value, histogram, plot profile, surface plot using NIB (Image J) image analysis program and compared decentering image with standard image. Mean value and standard deviation value of focus-grid lateral decentering and duplex decentering of focus-grid and head phantom decreased by ratio, consequently increase of horizontality, diagonal decentering. also, deteriorated contrast of image because frequency of high pixel value decreases fairly. according increases decentering, image distortion phenomenon was increase, by next time, pixel mean value of head phantom decentering was no big change but horizontality, diagonal, mean value and standard deviation value of pixel decreased by ratio. Even if increase pixel noise of image because wide latitude and post processing ability of digital detector, radiotechnologist can not recognize. Therefore, radiotechnologist must recognize correctly the photographing factors which increases pixel noise on the grid system installation digital detector and should exam.

  • PDF

Correction Method of Slit Modulation Transfer function on Digital Medical Imaging System (디지털 의료영상에서 슬릿법에 의한 Modulation Transfer Function의 보정방법)

  • Kim, Jung-Min;Jung, Hoi-Woun;Min, Jung-Whan;Im, Eon-Kyung
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.133-139
    • /
    • 2006
  • By using CR image pixel data, We examined the way how to calculate the MTF and digital characteristic curve. It can be changed to the text-file(Excel) from a pixel data which was printed with a digital x-ray equipment. In this place, We described the way how to figure out and correct the sharpness of a digital images of the MTF from FUJITA. Excel program was utilized to calculate from radiography of slit. Digital characteristic curve, Line Spread Function, Discrete Fourier Transform, Fast Fourier Transform digital specification curve, were indicated in regular sequence. A big advantage of this method, It can be understood easily and you can get results without costly program and without full knowledge of computer language. It shows many different values by using different correction methods. Therefore we need to be handy with appropriate correction method and we should try many experiments to get a precise MTF figures.

  • PDF

A Study on the Minimization of Spatial Error in 3-Demensional Neuronavigator (3차원 영상지원 뇌수술장비의 공간오차 최소화에 관한 연구)

  • 이동준;다영신;이정교
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.19-26
    • /
    • 1997
  • 3-dimensional Neuronavigator, Viewing Wand(ISG Technologies, Toronto, Cannda) is the surgery aid equipment for real time image (CT or MRI) guided surgery. The assurance of spatial accuracy of this system is important for clinical application. In this study, we have designed the acrylic brain phantom and measured the spatial error with that phantom. The phantom has designed to have capability to simulate image guided surgery. The phantom has 22 vertical rods whose diameters are 5mm and each rods has different length. CT scans were performed by 2.0mm slice and reconstructed for 3-Dimensional analysis. End point of rods can be obtained using reconstructed 3- Dimensional images and they are compared to actual position data. Average deviation was less than 2mm for various situations. Spatial error of Viewing Wand is acceptable in the clinical points of view, while cosmetics of the software needs to be modified to more user friend. Better accuracy can be expected when we apply the mixed fiducial fit registration and surface fit registration method. And even better results can be obtained if registration points distributed even and symetric around the target.

  • PDF

Comparison of Quality Control for Chest Radiography between Special Examination and Medical Institution for Pneumoconiosis (진폐 정밀/요양기관과 요양기관의 흉부 방사선분야 정도관리 비교)

  • Lee, Won-Jeong
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.2
    • /
    • pp.322-330
    • /
    • 2011
  • To compare of quality control for chest radiography between special examination (SEP) and medical institution for pneumoconiosis (MIP). For the first time, we had visited at 33 institutions (SEP; 17 institutions, MIP; 16 institutions) to evaluate the quality control of chest radiography which is used in diagnosis of patients with pneumoconiotic complications. Image quality was rated by two experienced chest radiologists, and evaluated for radiological technique (RT), reading environment (RE) and image quality (IQ) between SEP and MIP according to the guideline published by OSHRI. Generator capacity, used duration and modality of chest radiography equipment were not signigicant difference between SEP and MIP, but there were signigicant difference in tube voltage and grid ratio used for chest radiography except to tube current and exposure time. SEP was statistically significant higher in RT (71.2 vs. 54.5, p=0.015), RE (78.8 vs. 51.5, p=0.007) to MIP, but not significant difference in IQ (64.8 vs. 59.3, p=0.180). For reliable and precisional diagnosis of patients with pneumoconiotic complications, the MIP requires the evaluation and education of quality control for improving chest radiography.

Acceptance Test and Quality Control of Radiotherapy Treatment Simulator (의료용 모의치료기의 품질관리에 관한 연구)

  • 신동호;박성용;신동오;최진호;김유현;권수일
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.90-97
    • /
    • 2002
  • The simulator which has a identical geometry with radiotherapy equipments, is a essential equipment to accomplish optimized radiotherapy plan through simulation by using diagnostic low energy X-ray. A Radiotherapy simulator has a combined technology from the therapeutic and diagnostic radiology and needs a periodical test for mechanical and optical properties, X-ray generator, image intensifier of simulator to keep the proper maintenance and radiation safety. Hence, tests were done and classified as i) mechanical and optical parameter for the gantry, collimator, and couch ii) key performance of the X-ray generator such as a kVp, mAs, and timer iii) performance of the image intensifier such as a resolution and contrast for three kinds of simulator, common use in clinic. The above result of tests will be applied to the acceptance test and periodical quality assurance procedure.

  • PDF

Smart Glasses Cannula Guide System Development for Interventional Cardiology Procedures (중재적 심장 질환 시술을 위한 스마트 글래스 삽입관 가이드 시스템 개발)

  • Jang, Ik Gyu;Heo, Yeong Jun;Jeon, Geum Sang;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.173-178
    • /
    • 2020
  • Remote control intervention surgery robotic system improves treatment effect on cardiovascular patients and reduces X-ray exposure. However, at the time of the first procedure, CT (computerized tomography) and other ultrasound diagnostic equipment should be used because the operator must insert the cannula directly into the patient's leg. Improvements to this have been un-met-needs of hospitals. In this paper, we developed a system that can insert the cannula intuitively and quickly by displaying blood vessels at a glance through the system using smart wearable glasses. The core development method is as follows. In order to project augmented reality onto the surgical image, CT scan angiography image is extracted and processed. In the process, three CT-Markers are used to create a coordinate system of blood vessel images. Additionally, a reference marker is photographed on a single camera to obtain a camera coordinate system. Since the CT marker and the reference marker are in the same position, 3D registration is performed. In the text, a detailed explanation will be given.

When Evaluated Using CT Imaging Phantoms AAPM Phantom Studies on the Quantitative Analysis Method (AAPM Phantom을 이용한 CT 팬텀 영상 평가 시 정량적 분석 방법에 관한 연구)

  • Kim, Young-Su;Ye, Soo-Young;Kim, Dong-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.8
    • /
    • pp.592-600
    • /
    • 2016
  • AAPM CT performance for special medical equipment quality control checks using a standard phantom for evaluation, using the evaluator's subjective assessment as to minimize errors due computerized assessment program to evaluate their usefulness. Phantom for evaluation AAPM CT Performance Phantom: was used, the default shooting conditions are the same as quality control checks. And, we use IMAGE J to evaluate the program. Quantitative evaluation with CT attenuation coefficient and the noise measurement, the uniformity measurement, the slice thickness measurement, contrast resolution of the measurement, a phantom image of the spatial resolution determined by the evaluation program is evaluated as self-extracting the result after processing the image, CT uniformity measurement for the evaluation that was smaller and the standard deviation of a video image processing more uniform slice thickness measurements it is difficult to evaluate due to the difference of the ratio of the measured value of the phantom image. Contrast resolution was measured cylindrical diameter 6th evaluate the shape of a circle obtained a mean value and a standard deviation of diameters, the spatial resolution of the group of source, including acceptance criteria automatically extracted result as a result of both the number of the extracted circularIt appeared. Evaluate the source image and video processing, and video to qualitative evaluation by gross were processed video image is shown excellent results. If the evaluators in order to minimize the errors of subjective judgment based on the results of the above should be done with a quantitative evaluation and qualitative evaluation utilizes a computerized assessment program is considered that further evaluation be made more efficient.

Phantom of the AAPM CT imaging evaluation Studies on the quantitative analysis method (CT 정도관리 영상의 정량적 분석방법에 관한 연구)

  • Kim, Young-su;Ko, Seong-Jin;Kang, Se-Sik;Ye, Soo-young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.271-274
    • /
    • 2016
  • CT quality assurance imaging evaluation and enforcement as quantitative assessment by phantom image evaluation, assessment items include There are also contrasting the water attenuation coefficient, uniformity, noise, resolution, spatial resolution, 10mm slice thickness evaluation, contrast resolution, space for the resolution, the slice thickness evaluation, it is possible to estimate the error due to the evaluation by the subjective judgment of the tester, using a subjective error image processing program to be computed to minimize the objective evaluation. Basic recording conditions of the CT image quality control assessment is the same as special medical equipment quality control checks, the images were evaluated quantitatively using IMAGE J. For a CT attenuation coefficient, the uniformity, noise evaluation, were evaluated as CT quality control image the standard deviation of the measured value of the digital processing of image smaller and less noise uniform images than the, contrast and resolution assessment is the size of the diameter of a circle having a large the 1 inch, 0.75 inch, 0.5 inch quality if the diameter of the circle, was evaluated in the small circle in the near circle ellipse. Spatial resolution is evaluated by using a self-extracting features of an image processing program, all of the groups of members comprising the acceptance criteria to automatically extract, was evaluated to be very useful for the quantitative assessment. When CT image quality control assessment on the basis of the results such as the above, if using an image processing program to minimize the subjective judgment of the error evaluator and is determined more efficient than would be made quantitative evaluation.