• Title/Summary/Keyword: Medical equipment

Search Result 1,262, Processing Time 0.028 seconds

A Study on the Quantitative Evaluation Method of Quality Control using Ultrasound Phantom in Ultrasound Imaging System based on Artificial Intelligence (인공지능을 활용한 초음파영상진단장치에서 초음파 팬텀 영상을 이용한 정도관리의 정량적 평가방법 연구)

  • Yeon Jin, Im;Ho Seong, Hwang;Dong Hyun, Kim;Ho Chul, Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.390-398
    • /
    • 2022
  • Ultrasound examination using ultrasound equipment is an ultrasound device that images human organs using sound waves and is used in various areas such as diagnosis, follow-up, and treatment of diseases. However, if the quality of ultrasound equipment is not guaranteed, the possibility of misdiagnosis increases, and the diagnosis rate decreases. Accordingly, The Korean Society of Radiology and Korea society of Ultrasound in Medicine presented guidelines for quality management of ultrasound equipment using ATS-539 phantom. The DenseNet201 classification algorithm shows 99.25% accuracy and 5.17% loss in the Dead Zone, 97.52% loss in Axial/Lateral Resolution, 96.98% accuracy and 20.64% loss in Sensitivity, 93.44% accuracy and 22.07% loss in the Gray scale and Dynamic Range. As a result, it is the best and is judged to be an algorithm that can be used for quantitative evaluation. Through this study, it can be seen that if quantitative evaluation using artificial intelligence is conducted in the qualitative evaluation item of ultrasonic equipment, the reliability of ultrasonic equipment can be increased with high accuracy.

Factors Influencing Compliance on the Use of Personal Protective Equipment during Cleaning of Medical Device Reprocessing Staffs (의료기기 재처리 세척 직원의 개인보호구 착용 이행의 영향요인)

  • Park, Hyun Hee;Hong, Jung Hwa;Jeong, Gye Seon;Lee, Kwang Ok
    • Journal of muscle and joint health
    • /
    • v.31 no.1
    • /
    • pp.42-52
    • /
    • 2024
  • Purpose: This study aimed to identify the factors affecting compliance with personal protective equipment (PPE) use among medical device reprocessing staff. Methods: This descriptive cross-sectional study included 163 cleaning staff members from ten general hospitals in Seoul and Gyeonggi. Data were collected using self-report questionnaires administered between July and September 2023. Analysis included t-tests, ANOVA, Pearson's correlation coefficient, Bonferroni correction, and multiple regression, conducted using SAS ver.9.4. Results: Statistically significant differences in compliance with PPE were found based on department and exposure to contamination within six months (t=-2.82, p=.007). Attitudes toward PPE (r=.22, p=.006) and awareness of the safety climate (r=.22, p=.006) showed a statistically significant positive correlation with PPE compliance. Factors influencing use of personal protective equipment by cleaning staff during medical device reprocessing were department, compliance with PPE, and awareness of the safety climate. The explanatory power of these factors was 58.0%. Conclusion: Improving PPE compliance and creating a safe cleaning environment entails fostering a supportive safety climate. Additionally, regular training that takes into consideration the characteristics of the cleaning staff, alongside continuous monitoring, is required.

Amendment of the Inspection Standard for Diagnostic Radiation Equipment Applying IEC 60601-1-3: Medical Electrical Equipment - Part 1-3: General Requirements for Basic Safety and Essential Performance - Collateral Standard: Radiation Protection in Diagnostic X-ray Equipment (KS C IEC60601-1-3: 의료용 전기기기-제1-3부: 기본 안전 및 필수 성능에 관한 일반 요구사항-보조표준: 진단용 X선 장치의 방사선 방어를 적용한 진단용 방사선 발생장치의 검사기준 개선안)

  • Park, Hye-Min;Kim, Jung-Min;Kim, Jung-Su;Kim, Seong-Ok;Choi, Young-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.493-504
    • /
    • 2018
  • The diagnostic radiation equipment is managed in accordance with the "Rules for Safety Management of Diagnostic Radiation Equipment" enacted in 1995. The equipments should be inspected before use and every three years after use in accordance with the [Appendix 1] of the same rule. The inspection standard has been maintained without particular revision since enacted. But, over the past two decades new types of equipments have been manufactured and used. So, it is necessary to revise [Appendix 1] by making inspection items and inspection standards. In this study, we revised the classification system of equipments and reviewed international standards of IEC 60601 series, IEC 61223 series and AAPM TG 18 On-line Report No.03. And identified the problem of current inspection standards. Through this, we revised, deleted and added the inspection items and inspection standard of each equipment to meet the domestic circumstances. As a result of the study, we reorganized the classification system of equipment which are current classified as 5 classes into 22 classes as X-ray system etc. (7 classes), CT system etc. (5 classes) and Dental X-ray system etc. (10 classes). And then, we developed 70 inspection items for 6 types of equipments according to the reorganized classification system of equipments. The inspection items and inspection standards derived from this study have been proposed to the KCDC and will be applied to the revision of the Rule's [Appendix 1]. Therefore, we expect to be used as reference materials for domestic medical center, inspection institutions, and equipment manufacturing import companies.

A Break-Even Analysis that Helps with Decision Making involving the Introduction of Ultrasonography (초음파기기 도입 시 의사결정 지원을 위한 손익 분석)

  • Yeo, Seong-Hee;Lee, Hae-Jong;Seo, Young-Joon;Kim, Young-Hoon
    • Korea Journal of Hospital Management
    • /
    • v.14 no.3
    • /
    • pp.23-48
    • /
    • 2009
  • The purpose of this study was to provide criteria which help executives to make decisions through the analysis of profitability of ultrasonography conducted in each medical department. In order to achieve such purpose, the study conducted break-even analyses on three medical departments of a university hospital in which has used ultrasonography was largely conducted in diagnosing diseases and performing surgeries. The research was carried out from January to June 2008. The data necessary for calculating cost, were collected using by computerized data. The results of the study were summarized as follows. 1. The Cost structure of each medical department: The Cost of ultrasonography was divided into direct cost and indirect cost through the categorization by cost object. Labor cost accounted for the largest portion of the direct cost with 69.3% in the department of obstetrics and gynecology, 67.4% in the department of radiology and 58.2% in the cardiac ultrasonography center, which followed by the depreciation cost of ultrasonography equipment. The calculation of the average material cost of each ultrasonographic test by medical test found that the cardiac ultrasonography center took first place with 2,355 won, followed by the department of obstetrics and gynecology with 266 won and the department of radiology with 233 won. As for the power cost of ultrasonography equipment, the department of radiology took fist place with 442,000 won. The power cost, however, did not affect much the cost price, because it accounted for only a small portion of the cost. As for indirect cost, the cardiac ultrasonography center ranked first with 7,156,000 won. Building depreciation cost accounted for the largest portion of the indirect cost. 2. Break-even analysis: Under the supposition that cost price can be divided into fixed cost and variable cost, a break-even analysis was conducted using the cost price confirmed through the cost structure of each medical department. As for the average customary charge of ultrasonography test conducted in each medical department, the department of obstetrics and gynecology charged 24,627 won, the department of radiology 53,179 won and the cardiac ultrasonography center 65,174 won. According to these results, the charges of ultrasonography test imposed by the department of radiology and the cardiac ultrasonography center wre enough to surpass break-even levels, but the charge imposed by the department of obstetrics and gynecology was not enough to offset the cost price. In conclusion, labor cost accounted for the largest proportion of cost price of ultrasonography test conducted in diagnosing diseases and performing surgeries in medical departments, followed by the fixed cost of ultrasonographic equipment depreciation cost. In medical department where the current charge of ultrasonography test turned out not to offset cost price through the break-even analysis of ultrasonographic equipment, ways to reduce fixed cost which accounts for the largest proportion of the cost price should be sought. Even medical departments whose current charge of ultrasonography test is enough to surpass break-even level are required to work for efficient management and cost reduction to continuously generate profits.

  • PDF

A Study on the Architectural Planning of the Spaces Related With Digital Network System in General Hospital (병원 정보화 관련 실(室) 계획에 대한 연구)

  • Lim, Sung-Jae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.6 no.11
    • /
    • pp.107-116
    • /
    • 2000
  • The digital network system is one of the most important features in the resent hospital buildings. This study is to lay out a guideline of architectural planning according to the hospitals with digital network system. First, this study develops the concept of hospital building digital network system and reports the survey results of domestic general hospitals for this matter. Required spaces by digital network system in general hospital are classified into two categories. One is equipment room, main equipment room and a telecommunication closet, to accommodate network facilities. The other is the spaces related with medical information, medical archives and the department of radiology, because digital network system makes a change the form and use of information. In result, this study proposes models for each equipment room and raises the possibility of size change of information-spaces.

  • PDF

Method And Mathematical Algorithm For Finding The Quasi-Optimal Purpose Plan

  • Piskunov, Stanislav;Yuriy, Rayisa;Shabelnyk, Tetiana;Kozyr, Anton;Bashynskyi, Kyrylo;Kovalev, Leonid;Piskunov, Mykola
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.2
    • /
    • pp.88-92
    • /
    • 2021
  • A method and a mathematical algorithm for finding a quasi-optimal assignment plan with rectangular efficiency matrices are proposed. The developed algorithm can significantly reduce the time and computer memory consumption for its implementation in comparison with optimal methods.

Development and utility evaluation of new Multi-Leaf Collimator for Diagnostic X-ray Equipment

  • Ji, Hoon;Han, Su Chul;Baek, Jong Hyeun;Lee, Dong Hoon;Park, Seungwoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.936-942
    • /
    • 2018
  • The diagnostic multi-leaf collimator preventing unnecessary dose from entering into patients during the diagnostic examination was made in this study. The movement of the entire 50 leaves was embodied with the group of 25 ones thereof configured in a pair facing each other on the left and right of the median line. Dimensions of the length, width, and height of each shielding leaf were $5{\times}0.5{\times}0.5cm^3$ resulting in the maximum boost field of $10{\times}10cm^2$. The material of multi-leaf collimator had the excellence on the machinability with the use of the SKD-11 alloy tool steel having the high wear resistance against frequent movement, and it was devised to control both-side's shielding leaves by moving 2 motors unlike existing remedial multi-leaf collimator that use as many motors as the number of 50 shielding leaves. Thereafter, the transmission dose of leaves, cross-leaf leakage dose, and inter-leaf leakage dose were measured by the developed multi-leaf collimator attached to X-ray equipment. An ionization chamber was used to detect doses there from, and the comparative analysis was carried out by means of the radiographic film that was easy to detect the dose leakage in between each leaf. Results obtained from the test conducted in comparative analysis yielded approximately 98%, 96%, and 94% of shielding efficiency realized at each level of energy of 80kV, 100kV, and 120kV it was confirmed there was no dose leakage resulted from the varied level of irradiation energy. Thus the multi-leaf collimator to be developed based on this study is thought that it could fully reduce the unnecessary dose to patients in the diagnostic test and the shielding efficiency thereof is expected to be increasing if it is made in a miniaturized form with a way of increasing the thickness of each leaf later for an extended application to general diagnostic purposes.

The Difference in Attitude toward Medical Care between Patients and Physicians (환자와 의사의 의료에 대한 태도 차이 -한 중소도시의 대학병원과 한의과대학 부속 한방병원을 중심으로-)

  • Kang, Myung-Guen;Park, Jong-Ku;Kim, Han-Joong;Sohn, Myong-Sei;Kim, Dal-Rae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.3 s.62
    • /
    • pp.516-539
    • /
    • 1998
  • The objective of this study is to identify the difference in attitude toward medical care between patients who visited a university hospital or an oriental medical hospital of oriental medical college, and physicians who engaged in the same hospitals. The subjects of this study were 397 cases who agreed to respond the prepared questionnaire, including 288 patients(146 university hospital utilizers and 142 utilzers for an oriental medical hospital) and 109 physicians(76 physicians and 33 oriental medical doctors). The attitude toward medical care was measured by the structured questionnaire developed for this study, which had high validity and reliability according to factor analysis, item discriminant validity, and Cronbach's $\alpha$ coefficients. On the criteria of mean value of care and cure score, the attitude toward medical care was classified into 4 groups encompassing a group with dependent attitude on medical care, a group with skeptical attitude toward it, a group with cure-oriented attitude, and a group with care-preferred attitude. The results of chi-square test, discriminant analysis, and logistic regression analysis were as follows; patients who visited a univisity hospital, patients who visited an oriental hospital, physicians, and oriental medical doctors included in the group with dependent attitude, the group with cure-oriented attitude, the group with skeptical attitude, and the group with care-preferred attitude, retrospectively. Among the subdomains of care and cure domains, which classified in reference to the result of factor analysis on pilot study, those that patients ranked more importantly than physicians were 'the importance of medical equipment for diagnosis and treatment', 'authority of physician, 'aggressiveness of treatment', 'information giving', 'personal interest' in the case of western medicine. In the case of oriental medicine, those were 'the importance of equipment for diagnosis and treatment', 'aggressiveness of treatment', 'amenities and accessibility', 'coordination of medical staff'. Both physicans and patients put the subdomain, 'physicians' medical knowledge and skillfulness' on the highest rank. The differences in ranking the important attributes of medical care between patients and physicians were apparent in the area of an 'importance of medical equipment for diagnosis and treatment' and so on. It meant that patient had over-expectation on medical care and suggested that the policy on demanad side such as the developement and dissemination of an evidence-based recommendation protocol for health care consumers might be important in Korea. In addition, regarding the attitude of physicians, during the medical education and training it may be neccessary to emphasize the aspect of 'care' of medical care rather than 'cure'. In planning on heath care delivery system, it should be considered that there is a difference in the attitude toward medical care between western medicine and oriental medicine as well as between health care providers and consumers. We expect that more valid measurement tool be developed in this area, which may be major limitation of this study and that this kind of research be expanded into the non-academic settings.

  • PDF

Effect of wearing personal protective equipment on cardiopulmonary resuscitation: Focusing on 119 emergency medical technicians (개인보호장비 착용이 심폐소생술에 미치는 영향: 119 구급대원을 중심으로)

  • Shin, Dong-Min;Kim, Seung-Yong;Shin, Sang-Do;Kim, Chu-Hyun;Kim, Tae-Han;Kim, Kyoung-Yong;Kim, Jeong-Hee;Hong, Eun-Jeong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.19 no.3
    • /
    • pp.19-32
    • /
    • 2015
  • Purpose: This study examined the effect of wearing personal protective equipment (PPE) on cardiopulmonary resuscitation (CPR), positive airway pressure, and the posture of emergency medical technicians (EMTs) when conducting CPR. Methods: Twenty 119 EMTs performed 30:2 CPR on a manikin for 4 min. Imaging data were digitized with Kwon3D XP (version 4.0). Data were collected by analyzing the motion when starting in one cycle, such as pressing to the maximum and in the final position (relaxed), and were analyzed with SPSS 18.0. Results: The angle of the elbow joints was significantly reduced (p < .05). The trunk angle was statistically significantly (p < .01, p < .001) increased. The angular velocities of the shoulder joint and left elbow joint were reduced (p > .05). The angular velocity of the trunk was significantly reduced in the starting and maximum compression postures. The hand-escape time was increased. The average compression depth was increased but not significantly (p > .05). The positive airway pressure was reduced (p > .05). Conclusion: The angle of the elbow joints and the angular velocity of the trunk were reduced, and the angle of the trunk was increased. The success of CPR and positive airway pressure was reduced.

Guideline on Acceptance Test and Commissioning of High-Precision External Radiation Therapy Equipment

  • Kim, Juhye;Shin, Dong Oh;Choi, Sang Hyoun;Min, Soonki;Kwon, Nahye;Jung, Unjung;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.29 no.4
    • /
    • pp.123-136
    • /
    • 2018
  • The complex dose distribution and dose transfer characteristics of intensity-modulated radiotherapy increase the importance of precise beam data measurement and review in the acceptance inspection and preparation stages. In this study, we propose a process map for the introduction and installation of high-precision radiotherapy devices and present items and guidelines for risk management at the acceptance test procedure (ATP) and commissioning stages. Based on the ATP of the Varian and Elekta linear accelerators, the ATP items were checked step by step and compared with the quality assurance (QA) test items of the AAPM TG-142 described for the medical accelerator QA. Based on the commissioning procedure, dose quality control protocol, and mechanical quality control protocol presented at international conferences, step-by-step check items and commissioning guidelines were derived. The risk management items at each stage were (1) 21 ionization chamber performance test items and 9 electrometer, cable, and connector inspection items related to the dosimetry system; (2) 34 mechanical and dose-checking items during ATP, 22 multileaf collimator (MLC) items, and 36 imaging system items; and (3) 28 items in the measurement preparation stage and 32 items in the measurement stage after commissioning. Because the items presented in these guidelines are limited in terms of special treatment, items and practitioners can be modified to reflect the clinical needs of the institution. During the system installation, it is recommended that at least two clinically qualified medical physicists (CQMP) perform a double check in compliance with the two-person rule. We expect that this result will be useful as a radiation safety management tool that can prevent radiation accidents at each stage during the introduction of radiotherapy and the system installation process.