• Title/Summary/Keyword: Medical equipment

Search Result 1,262, Processing Time 0.021 seconds

Evaluation of surface dose comparison by treatment equipment (치료 장비 별 표면 선량 비교평가)

  • Choi Eun Ha;Yoon Bo Reum;Park Byoung Suk;An Ye Chan;Park Myoung Hwan;Park Yong Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.31-42
    • /
    • 2022
  • Purpose: This study measures and compares the surface dose values in the virtual target volume using Tomotherapy, Halcyon, and TrueBeam equipment using 6MV-Flattening Filter-Free(FFF) energy. Materials and Methods: CT scan was performed under three conditions of without bolus, 0.5 cm bolus, and 1 cm bolus using an IMRT phantom (IBA, Germany). The Planning Target Volume (PTV) was set at the virtual target depth, and the treatment plan was established at 200 cGy at a time. For surface dosimetry, the Gafchromic EBT3 film was placed in the same section as the treatment planning system and repeated measurements were performed 10 times and then analyzed. Result: As a result of measuring the surface dose for each equipment, without, 0.5 cm, 1 cm bolus is in this order, and the result of Tomotherapy is 115.2±2.0 cGy, 194.4±3.3 cGy, 200.7±2.9 cGy, The result in Halcyon was 104.7±3.0 cGy, 180.1±10.8 cGy, 187.0±10.1 cGy, and the result in TrueBeam was 92.4±3.2 cGy, 148.6±5.7 cGy, 155.8±6.1 cGy, In all three conditions, the same as the treatment planning system, Tomotherapy, Halcyon, TreuBeam was measured highly in that order. Conclusion: Higher surface doses were measured in Tomotherapy and Halcyon compared to TrueBeam equipment. If the characteristics of each equipment are considered according to the treatment site and treatment purpose, it is expected that the treatment efficiency of the patient will increase as well as the treatment satisfaction of the patient.

A Study on the Development of EKG Monitor in Operating Room (수술실용 EKG Monitor의 개발에 관한 연구)

  • 김원기;박용재
    • Journal of Biomedical Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.31-34
    • /
    • 1982
  • The development of biomedical instrument that is widely used in hospital played a important role in engineering with advance of electronic engineering. We have initiated the development of EKG monitor which is basically used in biomedical equipment, and then accomplished it especially considered patient safety.

  • PDF

A Development of Checklist for Applying Neuro Architecture Factors - Focused on Medical space (신경건축학적 요소 적용을 위한 체크리스트 개발 연구 - 의료공간을 중심으로)

  • Noh, Taerin;Suh, Swookyung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.2
    • /
    • pp.63-69
    • /
    • 2020
  • Purpose: The purpose of this study is to identify the neuro architecture items and detailed elements that can be considered for each detailed space in the future medical space design development through the development of a checklist of neuro architecture elements that can be utilized in medical space design. Methods:: This study first develops the neuro architecture element through theoretical research and prepares the basic plan for the checklist through consultation with the employees of the design company in which the researcher works. Finally, a checklist was developed through a survey of nine experts, including designers, hospital staff, and professors. Results: The result of this study 1) The neuro architecture component was developed in seven categories: light, color, sound, air, image, nature, ergonomic furniture and equipment. 2) Specifically, it consists of 49 elements including 7 light elements, 7 color elements, 5 sound elements, 4 air elements, 11 image elements, 6 elements in nature, 9 elements in ergonomic furniture and equipment. It was. 3) Although each of the detailed elements is more preferred according to the space, in general, all the elements should be considered in the context of the hospital space design. Implications: The checklist on the neuro architecture element will enable the development of the most faithful design as an efficient and useful tool for applying the neuro architecture philosophy that considers human beings in hospital design and pursues healing and happiness.

A Study on a Long-term Demand Forecasting and Characterization of Diffusion Process for Medical Equipments based on Diffusion Model (확산 모형에 의한 고가 의료기기의 수요 확산의 특성분석 및 중장기 수요예측에 관한 연구)

  • Hong, Jung-Sik;Kim, Tae-Gu;Lim, Dar-Oh
    • Health Policy and Management
    • /
    • v.18 no.4
    • /
    • pp.85-110
    • /
    • 2008
  • In this study, we explore the long-term demand forecasting of high-price medical equipments based on logistic and Bass diffusion model. We analyze the specific pattern of each equipment's diffusion curve by interpreting the parameter estimates of Bass diffusion model. Our findings are as follows. First, ultrasonic imaging system, CT are in the stage of maturity and so, the future demands of them are not too large. Second, medical image processing unit is between growth stage and maturity stage and so, the demand is expected to increase considerably for two or three years. Third, MRI is in the stage of take-off and Mammmography X-ray system is in the stage of maturity but, estimates of the potential number of adopters based on logistic model is considerably different to that based on Bass diffusion model. It means that additional data for these two equipments should be collected and analyzed to obtain the reliable estimates of their demands. Fourth, medical image processing unit have the largest q value. It means that the word-of-mouth effect is important in the diffusion of this equipment. Fifth, for MRI and Ultrasonic system, q/p values have the relatively large value. It means that collective power has an important role in adopting these two equipments.

Biorisk Assessment of Medical Diagnostic Laboratories in Nigeria

  • Oladeinde, Bankole Henry;Omoregie, Richard;Odia, Ikponmwonsa;Osakue, Eguagie Osareniro;Imade, Odaro Stanley
    • Safety and Health at Work
    • /
    • v.4 no.2
    • /
    • pp.100-104
    • /
    • 2013
  • Background: The aim of this study was to assess public and private medical diagnostic laboratories in Nigeria for the presence of biosafety equipment, devices, and measures. Methods: A total of 80 diagnostic laboratories in biosafety level 3 were assessed for the presence of biosafety equipment, devices, and compliance rate with biosafety practices. A detailed questionnaire and checklist was used to obtain the relevant information from enlisted laboratories. Results: The results showed the presence of an isolated unit for microbiological work, leak-proof working benches, self-closing doors, emergency exits, fire extinguisher(s), autoclaves, and hand washing sinks in 21.3%, 71.3%, 15.0%, 1.3%, 11.3%, 82.5%, and 67.5%, respectively, of all laboratories surveyed. It was observed that public diagnostic laboratories were significantly more likely to have an isolated unit for microbiological work (p = 0.001), hand washing sink (p = 0.003), and an autoclave ($p{\leq}0.001$) than private ones. Routine use of hand gloves, biosafety cabinet, and a first aid box was observed in 35.0%, 20.0%, and 2.5%, respectively, of all laboratories examined. Written standard operating procedures, biosafety manuals, and biohazard signs on door entrances were observed in 6.3%, 1.3%, and 3.8%, respectively, of all audited laboratories. No biosafety officer(s) or records of previous spills, or injuries and accidents, were observed in all diagnostic laboratories studied. Conclusion: In all laboratories (public and private) surveyed, marked deficiencies were observed in the area of administrative control responsible for implementing biosafety. Increased emphasis on provision of biosafety devices and compliance with standard codes of practices issued by relevant authorities is strongly advocated.

Developing Customized Phantom for Korean Bone Density Using 3D Printing (3D 프린팅을 이용한 한국인 골밀도 맞춤 팬텀 개발)

  • Lee, Junho;Choi, Kwan-Yong;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.223-229
    • /
    • 2019
  • In order to reduce the radiation exposure dose of the patient and to obtain accurate diagnosis results, the quality control of the diagnostic radiation generator must be conducted periodically In particular, bone density test equipment could be influenced by many factors, and it is far more important because inaccurate measurement would eventually affect the result value. However, the cross-correction phantom of DXA equipment is poorly penetrated due to lack of awareness of the industry and the high cost. Therefore, this study developed a BMD phantom using a 3D printer and Korean BMD phantom with low cost by cross analyzing Korean BMD value from The Korean National Health and Nutrition Examination Survey and evaluated it. The L1, L2, and L3 BMD values of phantoms produced with the 3D printer were measured to be $0.887{\pm}0.006g/cm^2$, $0.927{\pm}0.006g/cm^2$, and $0.960{\pm}0.005g/cm^2$, at 215 mm height and $0.882{\pm}0.011g/cm^2$, $0.914{\pm}0.005g/cm^2$, $0.933{\pm}0.008g/cm^2$ at 155 mm height displaying statistically significant relevance. The result suggests that a proper quality control and cross calibration of DXA device be possible and expected to be an essential data for various medical phantom manufacture development using 3D printer.

Evaluation of the Resolution Characteristics by Using ATS 535H Phantom for Ultrasound Medical Imaging (초음파 의료영상에서 ATS 535H 팬텀을 이용한 해상력 특성 평가)

  • Jung-Whan, Min;Hoi-Woun, Jeong;Hea-Kyung, Kang
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.15-21
    • /
    • 2023
  • This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.

De Lege Frenda for Improvement of Marine Telemedicine Service System (해양원격의료 지원제도 개선을 위한 관련 법령정비 방안)

  • JEON, Yeong-Woo;HONG, Sung-Hwa;KIM, Jae-Ho
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.4
    • /
    • pp.994-1005
    • /
    • 2016
  • Expansion and spreading of marine telemedicine is rather restricted due to the conflict of laws relating to medical service and lack of provisions in the Seafarers' Act, Medical Service Act, etc. Thus, this study is intended to reveal the current status and problems of marine emergency medical advice system for the furtherance of health care of seafarers and emergency medical assistance conditions and deduce relevant proposals for legislative improvements thereof in order to resolve underlying problems and issues. The results of this study can be summated as follows. First, in respect of directions to provide marine emergency service based on marine telemedicine system, emergency radio medical advice system needs to be strengthened to meet domestic and international instrument, marine telemedicine system needs to be provided through integrating u-Health technology and special marine medical center needs to be established. Second, regarding directions to provide health promotion service based on the marine telemedicine system, a new process of health care service for seafarers needs to be devised and provided involving seafarers' life cycle covering from prior to boarding to after leaving a ship. The conclusions of this study can be given as follows. First, the following new provisions need to be introduced in the Seafarers' Act. (1) The Minister of Oceans and Fisheries and a shipowner shall conduct matters pertaining to preventive health promotion and care for seafarers; (2) a provisions regarding establishment of seafarers' health promotion center by the Minister; (3) a special exemption permitting marine telemedicine service and qualification requirements for marine telemedicine assistant; (4) shipowner's obligation of carrying seafarers' health measuring equipment on board. Second, the relevant provisions regarding medical care persons needs to be revised in such a way that master or chief officer shall be appointed to be in charge of medical care on board. Last but not least, it is also essential to amend and update the minimum standards on drug and medicines to be carried on board and medicine chest and equipment on board.

Job Analysis of Ubiquitous Medical Electronic Device Export by the Method of DACUM (DACUM 법을 활용한 유비쿼터스 의료전자기기 전문가의 직무분석)

  • Cho, Dong-Heon;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1192-1197
    • /
    • 2013
  • In this paper Ubiquitous Medical Electronic Device Export was defined, and it's job analysis. The authors have been defined the job and classified duties and tasks of Ubiquitous Medical Electronic Device Export. To fine what is the most efficient task for Ubiquitous Medical Electronic Device Export, we have been investigated the levels of importance, difficulty, frequency and entry in each task. A DACUM committee is composed of total 12 members, which are one facilitator, 10 panel members, one coordinator & recorder to analyze the job of Ubiquitous Medical Electronic Device Export. Following is the result of this study. First, The process began with the identification of a job title and definition of Ubiquitous Medical Electronic Device Export. Second, a job model of Ubiquitous Medical Electronic Device Export is constructed based on the results of DACUM job analysis. 5 duties and 33 tasks are analyzed. Third, occupational specification was drawn up in consultation with SME council. Fourth, duty specification was drawn up in consultation. 33 tasks that are essential in entry level of occupation are identified. Fifth, task specification was drawn up in consultation. Detail task component which include skill, materials, knowledge, equipment, achievement level and tool was specified in task specification.

A Minimally Invasive lumbar Spine Surgery Technique Using a Modified Thoracoport : Proposal of a New Tubular Retractor

  • Park, Kwang-Woo;Park, Chan-Woo;Park, Jin-Soo;Lee, Sang-Gu
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.4
    • /
    • pp.296-299
    • /
    • 2006
  • Recently the trend of surgical procedure for treatment of lumbar benign disease is a minimally invasive surgery due to small incision, minimal blood loss, and a short hospital day. By using a microscope or an endoscope, and other surgical equipment, a delicate manipulation in a narrow space became feasible, consequently, to secure a wider view with small incision, appropriate retractors are required. But the various tubular retractor systems are expensive and have some problems. We modified Thoracoport [Auto Suture Co., Norwalk, CT] by making a window at the distal end of trocar and used it as a tubular retractor in surgical procedure for treatment of lumbar benign disease. This modified tubular retractor is docked closely on the curved lamina and provides a wider view. We used it as a tubular retractor also in lumbar bilateral decompression involving a unilateral approach. But this trocar has the limited sizes [diameter and length], and also it is difficult to fix the retractor or change the direction of retractor. And then, we propose a more modified Thoracoport with various sizes and attaching the settling holders to the head of tubular retractor to be able to fix the retractor.