• Title/Summary/Keyword: Medical electronics

Search Result 1,048, Processing Time 0.031 seconds

Enhancing the Image Transmission over Wireless Networks through a Novel Interleaver

  • El-Bendary, Mohsen A.M.;Abou-El-Azm, A.E.;El-Fishawy, N.A.;Shawki, F.;El-Tokhy, M.;Abd El-Samie, F.E.;Kazemian, H.B.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.9
    • /
    • pp.1528-1543
    • /
    • 2011
  • With increasing the using of wireless technologies in essential fields such as the medical application, this paper proposes different scenarios for the transmission of images over wireless networks. The paper uses the IEEE ZigBee 802.15.4 for applying the proposed schemes. It is a Wireless Personal Area Network (WPAN). This paper presents a novel chaotic interleaving scheme against error bursts. Also, the paper studies the proposed interleaver with the convolutional code with different constraint lengths (K). A comparison study between the standard scheme and proposed schemes for image transmission over a correlated fading channel is presented. The simulation results show the superiority of the proposed chaotic interleaving scheme over the traditional schemes. Also, the chaotic interleaver packet-by-packet basis gives a high quality image with (K=3) and reduces the need for the complex encoder with K=7.

Study on Analysis of Acoustic Noise in MRI (자기 공명 영상법에서의 소음 분석에 관한 연구)

  • Park, S.H.;Chung, S.T.;Chung, S.C.;Cho, Z.H.;Moon, C.W.;Yi, J.H.;Sin, C.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.550-554
    • /
    • 1997
  • Acoustic or sound noise due to gradient pulsing has been one of the problems in MRI, both in patient scanning as well as in many areas of psychiatric and neuroscience research, such as unctional MRI (fMRI). Our recent observations in MRI or the visual and motor cortex show very different results with sound noise in comparison with the results obtained without sound noise. Although a number of ideas has been suggested in the literature about the possible elimination or reduction of sound noise, progress has been slow due to the basic role of gradient pulsing in MR imaging. Therefore, we report on some typical behavior of sound noise observed from MRI scanners and the analyses of their characteristics. Data are obtained both from a commercial MRI scanner (GE Signa 1.5-T EPI system).

  • PDF

Compression and Enhancement of Medical Images Using Opposition Based Harmony Search Algorithm

  • Haridoss, Rekha;Punniyakodi, Samundiswary
    • Journal of Information Processing Systems
    • /
    • v.15 no.2
    • /
    • pp.288-304
    • /
    • 2019
  • The growth of telemedicine-based wireless communication for images-magnetic resonance imaging (MRI) and computed tomography (CT)-leads to the necessity of learning the concept of image compression. Over the years, the transform based and spatial based compression techniques have attracted many types of researches and achieve better results at the cost of high computational complexity. In order to overcome this, the optimization techniques are considered with the existing image compression techniques. However, it fails to preserve the original content of the diagnostic information and cause artifacts at high compression ratio. In this paper, the concept of histogram based multilevel thresholding (HMT) using entropy is appended with the optimization algorithm to compress the medical images effectively. However, the method becomes time consuming during the measurement of the randomness from the image pixel group and not suitable for medical applications. Hence, an attempt has been made in this paper to develop an HMT based image compression by utilizing the opposition based improved harmony search algorithm (OIHSA) as an optimization technique along with the entropy. Further, the enhancement of the significant information present in the medical images are improved by the proper selection of entropy and the number of thresholds chosen to reconstruct the compressed image.

Development of Real-time Closed-loop Neurostimulation System for Epileptic Seizure Suppression (뇌전증 경련 억제를 위한 실시간 폐루프 신경 자극 시스템 설계)

  • Kim, Sowon;Kim, Sunhee;Lee, Yena;Hwang, Seoyoung;Kang, Taekyeong;Jun, Sang Beom;Lee, Hyang Woon;Lee, Seungjun
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.95-102
    • /
    • 2015
  • Epilepsy is a chronic neurological disease which produces repeated seizures. Over 30% of epileptic patients cannot be treated with anti-epileptic drugs, and surgical resection may cause loss of brain functions. Seizure suppression by electrical stimulation is currently being investigated as a new treatment method as clinical evidence has shown that electrical stimulation to brain could suppress seizure activity. In this paper, design of a real-time closed-loop neurostimulation system for epileptic seizure suppression is presented. The system records neural signals, detects seizures and delivers electrical stimulation. The system consists of a 6-channel electrode, front-end amplifiers, a data acquisition board by National Instruments, and a neurostimulator and Generic Osorio-Frei algorithm was applied for seizure detection. The algorithm was verified through simulation using electroencephalogram data, and the operation of whole system was verified through simulation and in- vivo test.

Optical Transmission Characteristics of the Breast Tissue In the Range of Near IR (근접적외선 영역에서 Breast Tissue 의 광투과 특성)

  • Cho, Jin-Ho;Ha, Yeong-Ho;Lee, Kuhn-Il
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.159-168
    • /
    • 1986
  • As a fundamental study of Near IR tomography system, transmission parameters of the mongolian breast tissue at 904 nm wavelengh were measured. A analytical model to determin the light intensity in the breast was developed and the measurement, and gheoretical calculations were obtained.

  • PDF

Estimation of MCG parameters for the diagnosis of heart diseases (심질환 진단을 위한 심자도 파라메터의 추출)

  • Jeon, Chang-Ik;Huh, Young;Kim, Ki-Uk;Han, Byung-Hee;Jin, Seung-Oh;Chang, Won-Suk;Lee, Hyun-Ho
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.549-552
    • /
    • 2003
  • The electrical current generated by heart creates not only electric potential but also a magnetic field. We have observed electrophysiological phenomena of the heart by measuring tangential components of magnetocardiogram(MCG) using 61 channel superconducting quantum interference device(SQUD) system. In this paper, we developed a new analysis method, which is based on the theory of electromagnetic field. We show some differences of the current direction between the normal MCG and the abnormal(ischemic heart disease) MCG.

  • PDF

The Estimation of Blood Velocity from Heart in Medical Images using Regional Segmentation (영상분할을 이용한 의학영상에서의 심장혈류 측정)

  • 정철곤;김중규;김경섭
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.517-520
    • /
    • 1999
  • In this paper, we propose a non-invasive method to estimate blood velocity from the real medical images. To measure the magnitude and direction components associated with the blood velocity, we apply the optical flow analysis algorithm. It is demonstrated that the accuracy of the blood velocity estimate could possibly be increased by segmenting the optical flow region. We call this the Region Optical Flow(ROF) algorithm. We carried out some preliminary experiments using the aorta medical images, and corresponding regional optical flow diagrams are provided.

  • PDF

Low-level Laser Therapy with Novel Array of Light Source and Individualized Program for Treatment of Androgenetic Alopecia: A 16-week, Randomized, Double-blind, Sham Device-controlled Study

  • Kim, Jee-Woo;Kwon, Yeo-Seon;Chang, Yoon-Young;Hong, Sung-Ho;Shin, Jung-Won;Na, Jung-Im;Huh, Chang-Hun
    • Medical Lasers
    • /
    • v.9 no.2
    • /
    • pp.150-158
    • /
    • 2020
  • Background and Objectives Low-level laser therapy (LLLT) is used widely to promote hair growth in androgenetic alopecia (AGA). This study examined the clinical efficacy and safety of a home-use LLLT device with a newly designed array of light sources and software optimized for individual types of AGA. Materials and Methods The study was a randomized, double-blind, sham device-controlled trial. Forty-eight subjects (39 men and nine women) were assigned randomly in a 2:1 ratio to use either the test device (LG Pra'L HGN1, LG electronics, Korea) or sham device. The subjects used the LLLT device three times a week for 16 weeks. Phototrichogram was used to measure the hair density and hair thickness at 0, 8, and 16-weeks. Adverse events were closely monitored. Results After 16 weeks of using the device, the test group showed a significant increase in hair density and hair thickness compared to the control. In the test group, the hair density increased 6.96 counts/cm2 at eight weeks and 13.67 counts/cm2 at 16 weeks from the baseline. The hair thickness increased 7.21 ㎛ at eight weeks and 11.80 ㎛ at 16 weeks compared to the baseline. Conclusion The home-use LLLT device with a novel array of light sources and an individualized program according to the types of hair loss appears to be an effective and safe treatment modality for both male and female AGA patients.

A High Data Rate Medical Implant Communication System Transmitter for Body Implantable Devices (체내이식용 기기를 위한 고속 MICS 송신기 구현)

  • Im, Jun-Ha;Jung, Yun-Ho;Kim, Jae-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.4
    • /
    • pp.24-31
    • /
    • 2011
  • A high data rate Medical Implant Communications Service (MICS) transmitter for implantable medical devices (IMD) is proposed. An orthogonal frequency division multiplexing (OFDM)-based multicarrier scheme is used to overcome the data rate limitation caused by the narrow bandwidth of 300 kHz. The proposed transmitter utilizes multiple MICS channels simultaneously, supporting increased data rate. To satisfy the MICS regulation, various schemes are applied including optimized subcarrier allocation and inverse fast Fourier transform (IFFT) architecture, and additional sidelobe suppression technique. Simulation results show that the proposed transmitter can support a maximum data rate of 4.86 Mbps, which is more than ten times faster than the previous systems.