• Title/Summary/Keyword: Medical electronics

Search Result 1,053, Processing Time 0.032 seconds

Comparison of brain wave values in emotional analysis using video (영상을 이용한 감정분석에서의 뇌파 수치 비교)

  • Jae-Hyun Jo;Sang-Sik Lee;Jee-Hun Jang;Jin-Hyoung Jeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.6
    • /
    • pp.519-525
    • /
    • 2023
  • The human brain constantly emits electrical impulses, which is called brain waves, and brain waves can be defined as the electrical activity of the brain generated by the flow of ions generated by the biochemical interaction of brain cells. There is a study that emotion is one of the factors that can cause stress. Brain waves are the most used in the study of emotions. This paper is a study on whether emotions affect stress, and showed two images of fear and joy to four experimenters and divided them into three stages before, during, and after watching. As a measurement tool, brain waves at the positions of Fp1 and Fp2 were measured using the NeuroBrain System, a system that can automate brain wave measurement, analysis, brain wave reinforcement, and suppression training with remote control. After obtaining the brain wave data for each emotion, the average value was calculated and the study was conducted. As for the frequency related to stress, the values of Alpha and SMR, Low Beta, and High Beta were analyzed. Brainwave analysis affects stress depending on the emotional state, and "fear" emotions cause anxiety by raising Beta levels, resulting in higher Mind Stress levels, while "joy" emotions lower Beta levels, resulting in a significant drop in Mind Stress.

Development of a Prediction Model for Fall Patients in the Main Diagnostic S Code Using Artificial Intelligence (인공지능을 이용한 주진단 S코드의 낙상환자 예측모델 개발)

  • Ye-Ji Park;Eun-Mee Choi;So-Hyeon Bang;Jin-Hyoung Jeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.6
    • /
    • pp.526-532
    • /
    • 2023
  • Falls are fatal accidents that occur more than 420,000 times a year worldwide. Therefore, to study patients with falls, we found the association between extrinsic injury codes and principal diagnosis S-codes of patients with falls, and developed a prediction model to predict extrinsic injury codes based on the data of principal diagnosis S-codes of patients with falls. In this study, we received two years of data from 2020 and 2021 from Institution A, located in Gangneung City, Gangwon Special Self-Governing Province, and extracted only the data from W00 to W19 of the extrinsic injury codes related to falls, and developed a prediction model using W01, W10, W13, and W18 of the extrinsic injury codes of falls, which had enough principal diagnosis S-codes to develop a prediction model. 80% of the data were categorized as training data and 20% as testing data. The model was developed using MLP (Multi-Layer Perceptron) with 6 variables (gender, age, principal diagnosis S-code, surgery, hospitalization, and alcohol consumption) in the input layer, 2 hidden layers with 64 nodes, and an output layer with 4 nodes for W01, W10, W13, and W18 exogenous damage codes using the softmax activation function. As a result of the training, the first training had an accuracy of 31.2%, but the 30th training had an accuracy of 87.5%, which confirmed the association between the fall extrinsic code and the main diagnosis S code of the fall patient.

A Study on the Main Diagnostic Code according to the Analysis of the Frequency of Fall Patients by Case-Centered Damage External Code (사례 중심의 손상외인코드 별 낙상환자 빈도수 분석에 따른 주진단코드 연구)

  • Eun-Mee Choi;Ye-Ji Park;So-Hyeon Bang;Jin-Hyoung Jeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.6
    • /
    • pp.533-539
    • /
    • 2023
  • This study aimed to analyze patients hospitalized for injuries who fell using the data from 2020 to 2021 at institution A located in Gangneung-si, Gangwon-do, using codes for causes of injury. After classifying 20 codes from W00 to W19, which are external cause codes for fall patients, the most frequently occurring W18, W01, W10, and W13 were analyzed. The external cause of injury code W18 was other falls on the same plane, with the highest frequency of S72 and Z47, S72 being a fracture of the femur, and Z47 being orthopedic follow-up treatment. The external injury code W01 was determined to be a fall on the same plane due to slipping, tripping, and tripping, and like W18, S72, a fracture of the femur, and Z47, orthopedic follow-up treatment, were frequently reported. In W10, intracranial injuries such as concussion and epidural hemorrhage due to a fall on the stairs, S06, were common. Lastly, in W13, 91% of cases occurred in people in their 40s to 70s due to falls from buildings or structures, confirming that they occur frequently in middle-aged people, Z47 had the most frequent orthopedic follow-up treatment, and S72 had a fracture of the femur. It was found to be the second most common. In this way, the frequency of falling patients was analyzed, and the age and main diagnosis code at which most falls occurred were analyzed.

Development and application of non-invasive drug delivery systems utilizing pulse power, and its application to mouse models (펄스파워를 적용한 비침습 약물 전달기 개발 및 마우스 모델로의 적용)

  • Hwi-Chan Ham;Kyu-Sik Kim;Ji-Hwan Lee;Hyung-Jin Choi;Do-Nyun Kim;Jai-Ick Yoh
    • Journal of IKEEE
    • /
    • v.28 no.1
    • /
    • pp.97-103
    • /
    • 2024
  • Some drugs can offer far better medical effectiveness as it is injected through the intradermal layer of the skin, known as a needle-free injection. However, conventional needle-free devices might deliver a relatively large amount of drug in a just single spot of skin, splitting open the tissue layer structure, which might cause bruising and bleeding. By injecting the small volume with a fast repetition rate in a large surface area of skin, the patient may get much fewer injuries and pain. To achieve that specification, the driving force must be instantaneous and short-pulsed. Such a form of an injection device has been developed but the efficacy of those devices has been rarely examined. Therefore, this study developed the laser-induced microjet device that ejects microjet whose speed is ~310 m/s, during the 400~800 ㎲ of pulse time. The device can eject ~1 µL of the drug at the rate at which each shot repeated 10 shots per second. Using this specification, we evaluated the efficacy of drug injection onto mouse models. After injecting the insulin solution into the mouse model, the blood insulin level is detected, resulting in 20 % of blood insulin level with the ordinary needle syringe injection method.

Three-dimensional Model Generation for Active Shape Model Algorithm (능동모양모델 알고리듬을 위한 삼차원 모델생성 기법)

  • Lim, Seong-Jae;Jeong, Yong-Yeon;Ho, Yo-Sung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.6 s.312
    • /
    • pp.28-35
    • /
    • 2006
  • Statistical models of shape variability based on active shape models (ASMs) have been successfully utilized to perform segmentation and recognition tasks in two-dimensional (2D) images. Three-dimensional (3D) model-based approaches are more promising than 2D approaches since they can bring in more realistic shape constraints for recognizing and delineating the object boundary. For 3D model-based approaches, however, building the 3D shape model from a training set of segmented instances of an object is a major challenge and currently it remains an open problem in building the 3D shape model, one essential step is to generate a point distribution model (PDM). Corresponding landmarks must be selected in all1 training shapes for generating PDM, and manual determination of landmark correspondences is very time-consuming, tedious, and error-prone. In this paper, we propose a novel automatic method for generating 3D statistical shape models. Given a set of training 3D shapes, we generate a 3D model by 1) building the mean shape fro]n the distance transform of the training shapes, 2) utilizing a tetrahedron method for automatically selecting landmarks on the mean shape, and 3) subsequently propagating these landmarks to each training shape via a distance labeling method. In this paper, we investigate the accuracy and compactness of the 3D model for the human liver built from 50 segmented individual CT data sets. The proposed method is very general without such assumptions and can be applied to other data sets.

Aspect of the chief of state guard EMP (Electro Magnetic Pulse) protection system for the consideration (국가원수 경호적 측면에서의 EMP(Electro Magnetic Pulse) 방호 시스템에 대한 고찰)

  • Jung, Joo-Sub
    • Korean Security Journal
    • /
    • no.41
    • /
    • pp.37-66
    • /
    • 2014
  • In recent years, with the development of computers and electronics, electronics and communication technology in a growing and each part is dependent on the cross-referencing makes all electronic equipment is obsolete due to direct or indirect damage EMP. Korea and the impending standoff North Korea has a considerable level of technologies related to the EMP, EMP weapons you already have or in a few years, the development of EMP weapons will complete. North Korea launched a long-range missile and conducted a nuclear test on several occasions immediately after, when I saw the high-altitude nuclear blackmail has been strengthening the outright offensive nuclear EMP attacks at any time and practical significance for the EMP will need offensive skills would improve. At this point you can predict the damage situation of Korea's security reality that satisfy the need, more than anything else to build a protective system of the EMP. The scale of the damage that unforeseen but significant military damage and socio-economic damage and fatalities when I looked into the situation which started out as a satellite communications systems and equipment to attack military and security systems and transportation, finance, national emergency system, such as the damage elsewhere. In General, there is no direct casualties reported, but EMP medical devices that rely on lethal damage to people who can show up. In addition, the State power system failure due to a power supply interruption would not have thought the damage would bring State highly dependent on domestic power generation of nuclear plants is a serious nuclear power plant accident in the event of a blackout phenomenon can lead to the plant's internal problems should see a forecast. First of all, a special expert Committee of the EMP, the demand for protective facilities and equipment and conduct an investigation, he takes fits into your budget is under strict criteria by configuring the contractors should be sifting through. He then created the Agency for verification of performance EMP protection after you have verified the performance of maintenance, maintenance, safety and security management, design and construction company organized and systematic process Guard facilities or secret communications equipment and perfect for the EMP, such as protective equipment maneuver system should take.

  • PDF

A new diagnostic method for diabetic neuropathy using $TcpO_2$ ($TcpO_2$ 이용한 당뇨병성 신경병증 환자의 조기진단)

  • Hong, Hyun-Ki;Kim, Sung-Woo;Nam, Ki-Chang;Cha, Eun-Jong;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.3
    • /
    • pp.1-8
    • /
    • 2007
  • PDiabetic neuropathy is one of the most common diabetes related complications including diabetic nephropathy and retinopahty. In clinical practices, nerve conduction velocity (NCV) has been used as a standard method for diagnosing diabetic neuropathy. However, it applies maximum current of 100mA to nerves causing stress and pain to patients. In this study, as a non-invasive method, $TcpO_2$ was utilized to investigate the difference and relationship between $TcpO_2$ and $SpO_2$ of normal and diabetic neuropathy subjects. In addition, a new method of diagnosing diabetic neuropathy using $TcpO_2$ is suggested. 50 normal subjects and 50 diabetic patients with neuropathy diagnosed by NCV participated in this study. Parameters used in this study were $TcpO_2$, $TcpCO_2$, and $SpO_2$. As a result of the $TcpO_2$ measurements, statistical significances were found from $TcpO_2$ of hands and feet from normal and patients group(p<0.01). $SpO_2$ measured from index finger of normal and patient groups showed no statistical significance(p>0.05). On the other hand, $SpO_2$ measured from great toes of normal and patient groups showed statistical significance(p<0.01). Correlation coefficient between $SpO_2$ of finger and $TcpO_2$ of hand was 0.400 (p<0.01) and $SpO_2$ of toe and $TcpO_2$ of foot was 0.471(p<0.01). Both correlation values were statistically significant. Sensitivities and specificities of the $TcpO_2$ method were found to be 66 % and 92 %, respectively. If the suggested $TcpO_2$ method is used periodically, prevention and early diagnosis of diabetic neuropathy would be possible.

Simulation and Measurement of Signal Intensity for Various Tissues near Bone Interface in 2D and 3D Neurological MR Images (2차원과 3차원 신경계 자기공명영상에서 뼈 주위에 있는 여러 조직의 신호세기 계산 및 측정)

  • Yoo, Done-Sik
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.33-40
    • /
    • 1999
  • Purpose: To simulate and measure the signal intensity of various tissues near bone interface in 2D and 3D neurological MR images. Materials and Methods: In neurological proton density (PD) weighted images, every component in the head including cerebrospinal fluid (CSF), muscle and scalp, with the exception of bone, are visualised. It is possible to acquire images in 2D or 3D. A 2D fast spin-echo (FSE) sequence is chosen for the 2D acquisition and a 3D gradient-echo (GE) sequence is chosen for the 3D acquisition. To find out the signal intensities of CSF, muscle and fat (or scalp) for the 2D spin-echo(SE) and 3D gradient-echo (GE) imaging sequences, the theoretical signal intensities for 2D SE and 3D GE were calculated. For the 2D fast spin-echo (FSE) sequence, to produce the PD weighted image, long TR (4000 ms) and short TE$_{eff}$ (22 ms) were employed. For the 3D GE sequence, low flip angle (8$^{\circ}$) with short TR (35 ms) and short TE (3 ms) was used to produce the PD weighted contrast. Results: The 2D FSE sequence has CSF, muscle and scalp with superior image contrast and SNR of 39 - 57 while the 3D GE sequence has CSF, muscle and scalp with broadly similar image contrast and SNR of 26 - 33. SNR in the FSE image were better than those in the GE image and the skull edges appeared very clearly in the FSE image due to the edge enhancement effect in the FSE sequence. Furthermore, the contrast between CSF, muscle and scalp in the 2D FSE image was significantly better than in the 3D GE image, due to the strong signal intensities (or SNR) from CSF, muscle and scalp and enhanced edges of CSF. Conclusion: The signal intensity of various tissues near bone interface in neurological MR images has been simulated and measured. Both the simulation and imaging of the 2D SE and 3D GE sequences have CSF, fat and muscle with broadly similar image intensity and SNR's and have succeeded in getting all tissues about the same signal. However, in the 2D FSE sequence, image contrast between CSF, muscle and scalp was good and SNR was relatively high, imaging time was relatively short.

  • PDF

Evaluation of Metabolic Abnormality in Brain Tumors by In Viuo $^1$H MR Spectroscopy at 3 Tesla (3T 양성자 자기공명분광에 의한 뇌종양의 대사물질 이상소견)

  • Choe, Bo-Young;Jeun, Sin-Soo;Kim, Bum-Soo;Lee, Jae-Mun;Chung, Sung-Taek;Ahn, Chang-Beom;Oh, Chang-Hyun;Kim, Sun I.;Lee, Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.120-128
    • /
    • 2002
  • To investigate differences between the metabolic ratios of normal controls and brain tumors such as astrocytomas and glioblastoma multiforme (GM) by proton MR spectroscopy (MRS) at 37 high field system. Using 3T MRI/MRS system, localized water-suppressed single-voxel technique in patients with brain tumors was employed to evaluate spectra with peaks of N-acetyl aspartate (NAA), choline-containing compounds (Cho), creatine/phosphocreatine (Cr) and lactate. On the basis of Cr, these peak areas were quantificated as a relative ratio. The variation of metabolites measurements of the designated region in 10 normal volunteers was less than 10%. Normal ranges of NAA/Cr and Cho/Cr ratios were 1.67$\pm$018 and 1.16$\pm$0.15, respectively. NAA/Cr ratio of all tumor tissues was significantly lower than that of the normal tissues (P=0.005). Cho/Cr ratio of glioblastoma multiforme was significantly higher than that of astrocytomas (P=0.001). Lactate was observed in all tumor cases. The present study demonstrated that the neuronal degradation or loss was observed in all tumor tissues. Higher grade of brain tumors was correlated with higher Cho/Cr ratio, indicating a significant dependence of Cho levels on malignancy of gliomas. This results suggest that clinical proton MR spectroscopy could be useful to predict tumor malignancy.

  • PDF

Global Charity Operations of Cleft Lip and Palate by Korean Cleft Lip and Palate Association ; Charity Operations in Kenya, east Africa (대한구순구개열학회의 글로벌 자선 수술 활동 : 케냐에서의 자선 수술 활동)

  • Choung, Pill-Hoon;Park, Joo-Young;Park, Joo-Young;Ahn, Kang-Min;Baek, Jin-Woo;Cho, Il-Hwan;Choi, Cheol-Min;Choi, Seon-Hyu;Chung, Il-Hyuk;Gao, En-Feng;Hong, Jong-Rak;Hyun, Seung-Don;Jang, Hyon-Seok;Jun, Sang-Ho;Jung, Sung-Uk;Kang, Na-Ra;Kang, Young-Ho;Kim, Byung-Ryul;Kim, Dong-Hyun;Kim, Eun-Seok;Kim, Ho-Sung;Kim, In-Soo;Kim, Ji-Hyuck;Kim, Jong-Ryoul;Kim, Joong-Min;Kim, Myung-Jin;Kim, Soung-Min;Ko, Bong-Hwa;Koh, Sung-Hee;Lee, Bu-Kyu;Lee, Eui-Seok;Lee, Jong-Ho;Lee, Ui-Lyong;Lee, Won;Lee, Won-Deok;Min, Byong-Il;Nam, Il-Woo;Paeng, Jun-Young;Park, Jong-Chul;Park, Jung-Seok;Park, Sung-Hee;Park, Young-Wook;Pyo, Sung-Woon;Rim, Chae-Hong;Rim, Jae-Suk;Seo, Byoung-Moo;Suh, Je-Duck;Yoon, Jeong-Ho;Yoon, Jung-Ju;Yun, Hyung-Jin
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.9 no.2
    • /
    • pp.85-92
    • /
    • 2006
  • Korean Cleft Lip and Palate Association (KCLPA) was founded in 1996. The first overseas charity operation was in Karachi, Pakistan, 2002 and our association has visited fourteen times in six countries for the free cleft surgery: Pakistan, Egypt, Kenya, Morocco, Jordan and Vietnam. The cumulated number of operated patients reaches to 280. Before our association, many Korean oral and maxillofacial surgeons have performed charity operations individually since 1964. It was started from Vietnam but the activity is now carried on in Africa, middle-east Asia, south-east Asia, China, and Korea as an official team. LG electronics, a Korean company helped to propagate our team's activity to middle-east Asia to Africa. This paper is a report concerning about the results of our association's charity activities especially in Kenya, east Africa. We provided free cleft surgery for 30 patients in 2004 and 27 patients in 2005, in Nairobi. As the blood test for HIV of the cleft patients was not allowed before and during surgery, our surgeons and nurses were cautious about every movement during the surgeries. Thus the operation time for each patient was longer than any other time. The attitude of the local hospital and the doctors seemed to be accustomed to this situation. They helped us in case of needle injuries. Safety of medical staff and patients is more important than the number of the patients operated in charity operation. This belief should be approached being parallel and multidisciplinary as an international cooperation, focusing on international funding for medical support and continuous education for local doctors who are willing to devote to their people.

  • PDF