• 제목/요약/키워드: Medical appliance

검색결과 109건 처리시간 0.023초

스테인레스계열(17-4PH, 316L, 440C) 분말을 이용한 Dental Scaler Tip 분말사출금형 개발 (Development of Powder Injection Mold for Dental Scaler Tip Using Stainless Series Powder)

  • 고영배;김종선;황철진
    • 소성∙가공
    • /
    • 제16권1호
    • /
    • pp.61-66
    • /
    • 2007
  • Powder injection molding(PIM) is widely used for many parts in the field of automotives, electronics and medical industries, due to the capability of net shaping for complex 3-D geometry. Powder injection mold design for the dental scaler tip, a component of medical appliance, was presented. In comparison with conventional machining process, powder injection molding has many advantages, specially in price and dimensional stability, for molding dental scaler tip which has complex geometry. Both product design and mold design for dental scaler tip were presented. A PIM feedstock was made of stainless series(17-4PH, 316L, 440C) powder and a wax based binder. The 'rapid mold' concept was applied to manufacture the various forms and materials of dental scaler tip including vibration characteristics.

순환전압전류법을 이용한 수중 생물막 측정 전기화학센서 (Electrochemical Sensor for Detecting Underwater Biofilm Using Cyclicvoltammetry)

  • 황병준;이성호
    • 센서학회지
    • /
    • 제21권5호
    • /
    • pp.374-378
    • /
    • 2012
  • Biofouling causes many problem in industrial processes, medical health industries, water utilities and our daily life. So detecting formation of biofilm on the surface of medical appliance, water pipe and industrial utility is highly important to prevent the problem caused by biofouling. In this study, we suggest an electrochemical sensor for detecting biofilm. We fabricated the electrochemical sensor in MEMS process and cultivated two different kinds of Pseudomonas aeruginosa RpoN type and Wild type on the surface of electrochemical sensor. Each group of Pseudomonas aeruginosa was cultivated according to the hours of 2, 4, 6, 8, 12 and 24. Then we investigated changes in degree of biofilm cultivation using cyclic voltammetry. As a result, it was observed that peak of the cyclic voltammetry curve is increased according as the biofilm growth on the surface of electrochemical sensor. Also we can discern between Pseudomonas aeruginosa RpoN type and Wild type.

의료용 펌프의 리니어 모터 설계 및 해석 (Design and Analysis of Linear Motor for Medical Appliance Pump)

  • 김동수;이원희;박재범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2683-2686
    • /
    • 2002
  • In this paper, it has been investigated that the design and simulation of linear motor for medical appliances. Vacuum pump consists of unified plunger and piston part, coils, inlet valve and outlet valve. Operating principal of vacuum pump show that air is to flow to go inside through the inlet valve, when the magnetic force (16N) is exerted, whereas, air is to flow to go outside through outlet valve, when spring force (14.8N) is exerted. The results of simulation, it was turned out that magnetic force was loaded with 16 Newton, displacement of actuator was about 8mm.

  • PDF

Dental Scaler 분말사출용 금형설계 (Powder Injection Mold Design for Dental Scaler)

  • 박형필;고영배;정성택;이병옥;황철진
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.270-274
    • /
    • 2005
  • The capability of net shaping for complex 3-D geometry, powder injection molding(PIM) is widely used for parts in the field of automotives, electronics and medical industry. Powder injection mold design for dental scaler tip, a component of medical appliance, was presented. In comparison with conventional machining process, powder injection molding has many advantages, specially in price and dimensional stability, for molding dental scaler tip. Product design and mold design for dental scaler tip was presented. Short shot experiment with scaler tip PIM mold and several defect (flash etc.) during injection molding process was discussed.

  • PDF

선청성 구순구개열 환자의 장기적인 교정 치료 및 음성언어학적 고찰 (Long-term Orthodontic Treatment and Phonetic Assessment of a Congenital Cleft Lip and Palate Patient)

  • 홍지숙;김윤지;황용인;김대성;박양호
    • 대한구순구개열학회지
    • /
    • 제12권1호
    • /
    • pp.7-20
    • /
    • 2009
  • Orthodontic treatment planning of cleft lip and palate requires consideration of the characteristic features, growth pattern and functional disorders related to cleft lip and palate patients. Tissue deficiencies and constriction of the scar tissue in surgically treated cleft lip and palate results in disturbance of maxillary growth and deficiency of midfacial region with anterior and posterior crossbite. These patients often present congenital missing of teeth, supernumerary teeth, malformed teeth, or ectopic position of teeth, which should be treated by orthodontic treatment by expanding upper arch followed by fixed appliance. Proper use of retainer and continuous follow-up is needed to prevent relapse after orthodontic treatment has finished. Also we have to pay attention to correct speech disorder which is caused by the velopharyngeal insufficiency.

  • PDF

국내 동물용 의료기기 관리실태 평가 및 개선방안 연구 (Performance assessment and improvement plan of the regulatory management system of veterinary medical devices in Korea)

  • 안효진;윤향진;김충현;위성환;문진산
    • 대한수의학회지
    • /
    • 제55권2호
    • /
    • pp.97-103
    • /
    • 2015
  • In this study, the Korean veterinary medical devices management system was evaluated relative to systems in the USA, EU, and Japan. Veterinary medical devices are regulated in Korea based on the Medical Appliance Act of 1997. This was initially supervised by the Ministry of Agriculture, Food and Rural Affairs and Korea Animal Health Products Association, and subsequently by the Animal and Plant Quarantine Agency (QIA) in 2000. These devices were classified approximately 1,400 categories as instruments, supplies, artificial insemination apparatus, and other categories. Each of these devices was assigned to four regulatory grades by the QIA in 2007. The ranking system for veterinary medical devices was implemented in 2014 with 820 products from 162 companies registered by that year. However, in vitro diagnostic devices (IVDDs) for animals were managed as medical devices and biological medicine. In vitro diagnostic reagents for treating infection diseases are not subjected to either a classification or grading system. Veterinary medical devices are currently exempt from good manufacturing practices (GMP) and device tracking requirements. Due to gradual growth of the domestic veterinary medical devices market since 2008, regulation of these devices should be improved with re-examination of IVDDs and GMP certification for the effective operating system.

의료소비자가 인식하는 치과의원의 감염관리와 외부자극을 통한 재이용의사에 관한 연구 (A study on re-use intention through external stimuli and infection control of dental office perceived by medical consumer)

  • 조민정
    • 한국치위생학회지
    • /
    • 제11권4호
    • /
    • pp.571-580
    • /
    • 2011
  • Objectives : This study focused on examine the relevance between behavioral changes of customers and re-use intention on medical institution after experiencing infection control through external stimuli. Methods : This research was based on self-standing survey conducted from August to November 2010, 214 people who randomly selected from five dental clinics located in Busan were analyzed as the final group. Collected data were performed using SPSS 12.0 for Window. Results : 1. 82.8% of those surveyed who experienced external stimulation have changed their behavior on hospital environments and facilities, and 80.5% of them answered the stimuli influenced their re-use intention on medical institution. 2. There were no significant differences between participants by general characteristics on 'The reason why medical team wear sanitary appliances'. In age group 30~39, 85.4% of participants chose the answer so the difference were statistically significant(p<.001). Result by household income showed significant difference in group over $1,000 to $2,000 as 82.7% response(p<.05). 3. 94.4% of participants chose 'Required' for both surgical suits and gloves in research of 'The necessity level of personal sanitary appliances' which medical teams wear for treatment and 79.4% agreed that medical teams need to change their medical gloves whenever treating each patients. 4. The survey revealed that the most important appliance in patient's awareness were surgical gloves and protective goggles has chosen as the least important one. Conclusions : Patients as medical consumer were highly noticed of importance of the infection control in dental clinic and necessity of personal sanitary appliances. The patients who has accessed dental infection control information by external stimuli in advance showed objectival changes of their visit and behavioral changes with bringing medical environments together. This aspects influenced those patient's re-use intention in conclusion.

Orthodontic appliances and MR image artefacts: An exploratory in vitro and in vivo study using 1.5-T and 3-T scanners

  • Sonesson, Mikael;Al-Qabandi, Fahad;Mansson, Sven;Abdulraheem, Salem;Bondemark, Lars;Hellen-Halme, Kristina
    • Imaging Science in Dentistry
    • /
    • 제51권1호
    • /
    • pp.63-71
    • /
    • 2021
  • Purpose: The aim of this study was to assess the artefacts of 12 fixed orthodontic appliances in magnetic resonance images obtained using 1.5-T and 3-T scanners, and to evaluate different imaging sequences designed to suppress metal artefacts. Materials and Methods: In vitro, study casts of 1 adult with normal occlusion were used. Twelve orthodontic appliances were attached to the study casts and scanned. Turbo spin echo (TSE), TSE with high readout bandwidth, and TSE with view angle tilting and slice encoding for metal artefact correction were used to suppress metal artefacts. Artefacts were measured. In vivo, 6 appliances were scanned: 1) conventional stainless-steel brackets; 2) nickelfree brackets; 3) titanium brackets; 4) a Herbst appliance; 5) a fixed retainer; and 6) a rapid maxillary expander. The maxilla, mandible, nasopharynx, tongue, temporomandibular joints, and cranial base/eye globes were assessed. Scores of 0, 1, 2, and 3 indicated no artefacts and minor, moderate, and major artefacts, respectively. Results: In vitro, titanium brackets and the fixed retainer created minor artefacts. In vivo, titanium brackets caused minor artefacts. Conventional stainless-steel and nickel free brackets, the fixed retainer, and the rapid maxillary expander caused major artefacts in the maxilla and mandible. Conventional stainless-steel and nickel-free brackets caused major artefacts in the eye globe (3-T). TSE with high readout bandwidth reduced image artefacts in both scanners. Conclusion: Titanium brackets, the Herbst appliance, and the fixed retainer caused minor artefacts in images of neurocranial structures(1.5-T and 3-T) when using TSE with high readout bandwidth.

Three-dimensional cone beam computed tomography analysis of temporomandibular joint response to the Twin-block functional appliance

  • Jiang, Yuan-yuan;Sun, Lian;Wang, Hua;Zhao, Chun-yang;Zhang, Wei-Bing
    • 대한치과교정학회지
    • /
    • 제50권2호
    • /
    • pp.86-97
    • /
    • 2020
  • Objective: To propose a three-dimensional (3D) method for evaluating temporomandibular joint (TMJ) changes during Twin-block treatment. Methods: Seventeen patients with Class II division 1 malocclusion treated using Twin-block and nine untreated patients with a similar malocclusion were included in this research. We collected their cone beam computed tomography (CBCT) data from before and 8 months after treatment. Segmentations were constructed using ITK-SNAP. Condylar volume and superficial area were measured using 3D Slicer. The 3D landmarks were identified on CBCT images by using Dolphin software to assess the condylar positional relationship. 3D models of the mandible and glenoid fossa of the patients were constructed and registered via voxel-based superimposition using 3D Slicer. Thereafter, skeletal changes could be visualized using 3DMeshMetric in any direction of the superimposition on a color-coded map. All the superimpositions were measured using the same scale on the distance color-coded map, in which red color represents overgrowth and blue color represents resorption. Results: Significant differences were observed in condylar volume, superficial area, and condylar position in both groups after 8 months. Compared with the control group (CG), the Twin-block group exhibited more obvious condyle-fossa modifications and joint positional changes. Moreover, on the color-coded map, more obvious condyle-fossa modifications could be observed in the posterior and superior directions in the Twin-block group than in the CG. Conclusions: We successfully established a 3D method for measuring and evaluating TMJ changes caused by Twin-block treatment. The treatment produced a larger condylar size and caused condylar positional changes.