• Title/Summary/Keyword: Medical and Measuring Instrument

Search Result 81, Processing Time 0.024 seconds

Vapor Recognition Using Image Matching of Micro-Array Sensor Response from Portable Electronic Nose (휴대용 전자 후각 장치에서 다채널 마이크로 센서 신호의 영상 정합을 이용한 가스 인식)

  • Yang, Yoon-Seok
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.2
    • /
    • pp.64-70
    • /
    • 2011
  • Portable artificial electronic nose (E-nose) system suffers from noisy fluctuation in surroundings such as temperature, vapor concentration, and gas flow, because its measuring condition is not controled precisely as in the laboratory. It is important to develop a simple and robust vapor recognition technique applicable to this uncontrolled measurement, especially for the portable measuring and diagnostic system which are expanding its area with the improvements in micro bio sensor technology. This study used a PDA-based portable E-nose to collect the uncontrolled vapor measurement signals, and applied the image matching algorithm developed in the previous study on the measured signal to verify its robustness and improved accuracy in portable vapor recognition. The results showed not only its consistent performance under noisy fluctuation in the portable measurement signal, but also an advanced recognition accuracy for 2 similar vapor species which have been hard to discriminate with the conventional maximum sensitivity feature extraction method. The proposed method can be easily applied to the data processing of the ubiquitous sensor network (USN) which are usually exposed to various operating conditions. Furthermore, it will greatly help to realize portable medical diagnostic and environment monitoring system with its robust performance and high accuracy.

The Usefulness of Al Face Block Fabrication for Reducing Exposure Dose of Thyroid Glands in Mammography (유방촬영 시 갑상샘의 피폭선량 경감을 위한 Al Face Block 제작 및 유용성에 관한 연구)

  • Hong, Eun-Ae;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.11-17
    • /
    • 2013
  • Currently, there are many studies being conducted around the world to reduce exposure dose to radiation for patients to receive medical treatments in a safe environment. We developed and fabricated of this shield that the patients are protected from the radiation and are need of safety control during breast imaging. In this study, for breast imaging, GE Senography 2000D were used and set at SID 65cm, 28kVp, and 63mAs. The measuring instrument was Fluke's Victoreen 6000-529. And we performed Face Block on with 30 patients. The chamber on the actual thyroid glands to take CC and MLO and measure the dosage before and after wearing the Face Block. For the results, after wearing the Face Block, exposure was decreased by 53.8%-100% and 65.8% in average in CC View and by 50%-100% and 60.7% in average in MLO View. The development of the Face Block that practically decreased the exposure dose of thyroid glands, crystalline eyes during breast imaging and reduced the patients' anxiety during breast imaging. The Face Block is expected to improve patients' satisfaction and contribute to reducing patients' exposure dose, but more efforts should be made to reduce exposure dose to medical radiation.

Developing Measurement Items for the Service Quality of Clinical Trials based on the Brady & Cronin Model (Brady & Cronin의 모델에 기반한 임상시험 서비스 질 측정 문항 개발)

  • Go-Eun Lee;Sanghee Kim;Sue Kim;Sang Hui Chu;Jeong-Ho Seok;So Yoon Kim
    • The Journal of KAIRB
    • /
    • v.6 no.1
    • /
    • pp.17-31
    • /
    • 2024
  • Purpose: This study aims to develop preliminary items for measuring the perceived service quality of clinical trials among participants and to verify content validity. Methods: This study was designed as a methodological study. A conceptual framework was established based on Brady and Cronin's hierarchical model, and preliminary items were prepared through translation-back-translation, a review of existing instruments, and in-depth interviews with clinical trial participants and clinical research coordinators. The final items were completed through content validity testing by experts and a review of items by clinical trial participants for the prepared preliminary items. Results: Through this study, a set of 58 items across four domains (quality of interaction with researchers, the physical environment, performance procedures, and performance results) and 9 components (information·education·communication, trust, respect for participant preferences, securing facilities and space, accessibility, comfortability, informed consent, coordination of care, subjective understanding of clinical trials) on the service quality of clinical trials were completed. The scale content validity index of all preliminary items was 0.96, meeting the recommended standards. The individual-item content validity index also meets the recommended criteria for most items, excluding four items. Conclusion: This study holds significance in developing items to measure the quality of clinical trial execution from the perspective of participants. By verifying the reliability and validity of these items through subsequent research, it is expected that they can be utilized as a valuable instrument to devise strategies for improving the quality of clinical trials.

  • PDF

DEVELOPMENT OF SCALE FOR MEASURING DELINQUENT BEHAVIOR (청소년 비행행동 측정도구 개발)

  • Kim, Hyun-Sil;Kim, Hun-Soo
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.11 no.1
    • /
    • pp.79-90
    • /
    • 2000
  • Objective:This study was performed in order to develop a measuring instrument for assessing and predicting delinquent behavior of the adolescents in Korea. Methods:This study was methodological research for developing a questionnaire for measuring delinquent behavior. Through the relevant literature review and personal interview using open-ended question with 12 adolescents in schools, outpatient basis and the juvenile corrective institutions, the author developed a pre-questionnaire with 31 items for assessing delinquent behavior among delinquentprone adolescents. Statistical method employed were test-retest reliability and Cronbach's alpha coefficient for testing reliability and factor analysis for testing validity of this questionnaire, and t-test for mean difference between student adolescents and delinquent adolescents, using SAS program. Subject served for this study consisted of 2,177 adolescents including 1,206 students and 971 delinquent adolescents by proportional stratified random sampling method. Results:1) Three stable factors were emerged and these contributed 52.2% of the variance in the total score. All 31 items loaded above .40 on each factor. 2) Factor I was named as antisocial delinquent behavior(17 items), factor II was named as aggressive delinquent behavior(8 items), and factor III was named as psychopathic delinquent behavior(6 items). 3) Comparison of these 3 factors between student adolescents and delinquent adolescents showed that there was a significant difference in factor Ⅰ(t=-42.91(student), -41.71(delinquent), p=.0001), factor II(t=-34.10(student), -35.72(delinquent), p=.0001), factor III(t=-14.24(student), -14.26 (delinquent), p=.0000), and total score(t=37.02(student), -36.38(delinquent), p=.0001). 4) Internal consistency reliability was tested by Cronbach's ${\alpha}$. Cronbach's ${\alpha}$ was .952 for total 31 items and .950, .866 and .721 for each 3 factors related to delinquent behavior. Conclusions:The author confirmed that this scale can use for measuring delinquent behavior, and hope to make a contribution to screening test and prevention of juvenile delinquency in Korea.

  • PDF

The Clinical Usefulness Measurement of the Whole Body Percent Fat Calculated by the Part Bone Mineral Density Measurement (부분골밀도 측정을 통해 산출되는 체지방률의 임상적 유용성에 대한 평가)

  • Kang, Young-Eun;Kim, Eun-Hye;Kim, Ho-Sung;Choi, Jong-Sook;Choi, Woo-Jun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.3-9
    • /
    • 2011
  • Purpose: Generally dual energy X-ray absorptiometry has been used for the purpose of evaluation of osteoporosis and treatment. Recently the interest of obesity came to be high and body percent fat test is increasing. Existing measure of body fat have to scan the whole body can be evaluated, but only lumbar spine and hip measurements was assumed to be whole body fat as well as improving the software. It tries to check whether the part measured value not being whole body measurement has the validity or not compared with the value calculated with the method that it is different, it forgives through a correlation with a (BIA) and (BMI). Materials and Methods: In 2010, the body percent fat was measured among the examinee coming to the Asan Medical Center public health care center from March till August against 90 females more than 40 years old through (DXA) and BIA. BMI utilized the value which wrote an hight and weight measured through the body measuring instrument in the examinee information and is automatically calculated. In addition, it classified as the low weight ($13-18.5kg/m^2$), normal ($18.5-25kg/m^2$), and corpulence ($25-30kg/m^2$) based on BMI and so that it could check whether there was the difference according to the weight or not BMI and BIA and correlation between DXA were analyzed in each group. The statistical program for the analysis used SPSS 12.0. Results: The comparison of DXA at 3 which it divides into the low weight and normal and corpulence groups and BIA did not show the difference noted statistically in all groups and the between group comparison was exposed to do not have a meaning. The body percent fat measured by the correlation analysis result DXA at the state that it doesn't divide into the group showed the high correlation (r=0.908, p0.01) noted statistically compared with BMI and showed the high correlation noted statistically in a comparison with BIA (r=0.927, p0.01). Conclusion: It confirmed that the whole body percent fat presumed from the part bone density measurement showed the excel correlation compared with BIA and BMI and information is high. There is still no clear standard about the presumed whole body percent fat and it is difficult to evaluate the fat evaluation by the bone mineral density measurement. However, it is determined that the information offering which is more objective through the comparative study with the body percent fat which is very efficient and in that it can obtain till the information about a fat as well as diagnosis of the osteoporosis through the bone density checkup is measured by the afterward telegraph bone density checkup and is clinically useful is possible.

  • PDF

Development of Bioelectric Signal Sensor System using Band Type ECG (밴드형 심전도 생체신호 전극시스템의 구현)

  • Kang Sung-Chul;Kim Gi-Ryon;Kim Kwang-Nyeon;Jung Dong-Keun;Kim Min-Sung;Jeong Do-Wun;Jeon Gye-Rok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.1023-1026
    • /
    • 2006
  • There are some cases in trouble with monitoring emergency patient by existing electrode sensor in measuring instrument in home and hospital etc. And there are problem to measure because of coming down electrode in emergency car or vessel of shaking and fat, humidity of patient. In this study, it has designed band-type for patient to put on the breast easily and go around anywhere freely putting band electrode on his body. Gold has used as electrode material in this electrocardiogram because of its excellent electronic resistance peculiarity and no trouble with skin. And it is able to monitor multi-body-signal by additional design of periphery temperature. There are good results of body signal transmission in the breast or the rib, and get a little body signal in abdomen. We get a result it is better case of gold than usual electrode on signal detection, and know usual electrode was disposable, but we have more correct result from gold electrode sensor, being semi-permanent ana. great contact ability even if movement.

  • PDF

Experimental Research for Traction force Sensor Development on Drawing Exercise Medical Instrument (재활 및 교정을 위한 견인운동치료기의 견인측정센서 개발에 관한 실험적 연구)

  • Lee, Sang-sik;Park, Won-yeop;Lee, Choong-ho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.2
    • /
    • pp.3-8
    • /
    • 2009
  • The traction system has been mainly used for rehabilitation and correction of patients with spine or gait diseases in orthopedics or at home. Some problems could occur in human body when patients forced their training using the traction system. So it needs to measure a traction force and control the training time. However, most of products on market have no sensor measuring traction force. Thus we designed and made a sensor detecting traction force using strain gauge, amplifier for transition to output signal and experiment devices for performance test. We carried out experiment of a sensor detecting a traction force and measured electric responses of it with respect to traction loads. Maximum error was within about 1% for experiments in static condition and the average error was about 0.7% for experiments in dynamic condition. We concluded that it is possible to use the developed sensor for measurement of traction force since the maximum output variation of a sensor detecting a traction force was about 0.3% in $0^{\circ}C-60^{\circ}C$ temperature condition.

  • PDF

Assessment of the Hydration Effect on In Vitro Human Skin by $^1H$ MRS at 14.1T System (고자장 14.1 T MRI/MRS 시스템에서 양성자 자기공명분광법을 이용한 생체 외 인체피부 보습효과에 대한 연구)

  • Choi Chi-Bong;Hong Sung-Tak;Woo Dong-Chul;Yoon Seong-Ik;Yoon Moon-Hyun;Cho Ji-Hyun;Lee Chul-Hyun;Cheong Chae-Joon;Park Sang-Yong;Oh Chil-Hwan;Choe Bo-Young
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.83-88
    • /
    • 2006
  • Purpose: We Investigated to achieve high resolution magnetic resonance (MR) Imaging and spectra of human skin in vitro with using a 14.1 T MRI/MRS system, and to evaluate the hydration effect of a moisturizer by measuring the skin's water concentration. Materials and Methods: We used the Brukrer 14.1 T MRI/MRS system with a vertical standard bore that was equipped with a DMX spectrometer gradient system (200 G/cm at a maximum 40 A), RF resonators (2, 5 and 10 mm) and Para Vision software. Spin echo and fast spin echo pulse sequences were employed for obtaining the high resolution MR images. The 3D-localized point resolved spectroscopy (PRESS) method was used to acquire the MR spectra. Results: The high resolution MR images and spectra of human skin in vitro were successfully obtained on a 14.IT system. The water concentration of human skin after applying a moisturizer was higher than that before applying a moisturizer. Conclusions: The present study demonstrated that the high-resolution MR images and spectra of human skin from a high field MRS instrument could be applicable to evaluating the hydration state of the stratum corneum.

  • PDF

Analysis of Variation for Parallel Test between Reagent Lots in in-vitro Laboratory of Nuclear Medicine Department (핵의학 체외검사실에서 시약 lot간 parallel test 시 변이 분석)

  • Chae, Hong Joo;Cheon, Jun Hong;Lee, Sun Ho;Yoo, So Yeon;Yoo, Seon Hee;Park, Ji Hye;Lim, Soo Yeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.51-58
    • /
    • 2019
  • Purpose In in-vitro laboratories of nuclear medicine department, when the reagent lot or reagent lot changes Comparability test or parallel test is performed to determine whether the results between lots are reliable. The most commonly used standard domestic laboratories is to obtain %difference from the difference in results between two lots of reagents, and then many laboratories are set the standard to less than 20% at low concentrations and less than 10% at medium and high concentrations. If the range is deviated from the standard, the test is considered failed and it is repeated until the result falls within the standard range. In this study, several tests are selected that are performed in nuclear medicine in-vitro laboratories to analyze parallel test results and to establish criteria for customized percent difference for each test. Materials and Methods From January to November 2018, the result of parallel test for reagent lot change is analyzed for 7 items including thyroid-stimulating hormone (TSH), free thyroxine (FT4), carcinoembryonic antigen (CEA), CA-125, prostate-specific antigen (PSA), HBs-Ab and Insulin. The RIA-MAT 280 system which adopted the principle of IRMA is used for TSH, FT4, CEA, CA-125 and PSA. TECAN automated dispensing equipment and GAMMA-10 is used to measure insulin test. For the test of HBs-Ab, HAMILTON automated dispensing equipment and Cobra Gamma ray measuring instrument are used. Separate reagent, customized calibrator and quality control materials are used in this experiment. Results 1. TSH [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [14.8 / 4.4 / 3.7 / 0.0 ] C-2(middle concentration) [10.1 / 4.2 / 3.7 / 0.0] 2. FT4 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [10.0 / 4.2 / 3.9 / 0.0] C-2(high concentration) [9.6 / 3.3 / 3.1 / 0.0 ] 3. CA-125 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 4.3 / 4.3 / 0.3] C-2(high concentration) [6.5 / 3.5 / 4.3 / 0.4] 4. CEA [%diffrence Max / Mean / median] (P-value by t-test > 0.05) C-1(low concentration) [9.8 / 4.2 / 3.0 / 0.0] C-2(middle concentration) [8.7 / 3.7 / 2.3 / 0.3] 5. PSA [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [15.4 / 7.6 / 8.2 / 0.0] C-2(middle concentration) [8.8 / 4.5 / 4.8 / 0.9] 6. HBs-Ab [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 3.7 / 2.7 / 0.2] C-2(high concentration) [8.9 / 4.1 / 3.6 / 0.3] 7. Insulin [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [8.7 / 3.1 / 2.4 / 0.9] C-2(high concentration) [8.3 / 3.2 / 1.5 / 0.1] In some low concentration measurements, the percent difference is found above 10 to nearly 15 percent in result of target value calculated at a lower concentration. In addition, when the value is measured after Standard level 6, which is the highest value of reagents in the dispensing sequence, the result would have been affected by a hook effect. Overall, there was no significant difference in lot change of quality control material (p-value>0.05). Conclusion Variations between reagent lots are not large in immunoradiometric assays. It is likely that this is due to the selection of items that have relatively high detection rate in the immunoradiometric method and several remeasurements. In most test results, the difference was less than 10 percent, which was within the standard range. TSH control level 1 and PSA control level 1, which have low concentration target value, exceeded 10 percent more than twice, but it did not result in a value that was near 20 percent. As a result, it is required to perform a longer period of observation for more homogenized average results and to obtain laboratory-specific acceptance criteria for each item. Also, it is advised to study observations considering various variables.

Study on Ego states in the view of Transactional analysis, Coping style and Health states of Nursing Students (상호교류분석으로 본 간호학생의 자아상태와 스트레스 대처방법 및 건강상태에 관한 연구)

  • Won, Jeong-Sook;Kim, Jeong-Hwa
    • Journal of East-West Nursing Research
    • /
    • v.7 no.1
    • /
    • pp.68-81
    • /
    • 2002
  • The purpose of this study is to analyze the type of ego states and stress coping style on female college students who are in the course of nursing study. This study is performed in the view of Transactional Analysis and designed to scrutinize descriptive correlations between the type of ego states and stress coping style. The subject is consists of 144 freshmen and sophomore, 138 junior and senior students group, who are students of K nursing college located in Seoul. The sampling investigation period is on Sept. 14, 2002 to Oct. 26, 2002. The measuring instrument used for Transactional Analysis ego state is 50 items Ego-gram research paper devised by Dusay(1997). For studying coping style, Folkman & Lazarus's measurement(1984) was adopted, which is translated and modified by Han, and Oh,(1990). Health states is adopted by standardized health inspecting instrumental table (Cornell Medical Index:CMI) which is designed for Korean people by Ko and Park(1980) Statistic average and standard deviation were generated by using SPSS PC+, t=test and Pearson correlation. The results were as follows: 1) In the type of ego states on both groups indicated the arithmetic apex NP(maximum value), then the point A was high and the data made a down slope to point AC. In the comparison to type of ego states between two groups, only at point CP, the data value of upper year students represented higher than that of lower year ones by c(t=2.28, p=.023). 2) Stress coping style of whole students were highly and affirmatively dedicated to research. Especially hopeful aspect(t=.67, p=.05), relaxation of tension(t=-2.16, p=.03) made significant difference each other in the view of arithmetic calculation. 3) In view of nursing students' physical health states, there is significant difference in past history(t=2.50, p=.013) and in case of mental health states, there are considerable discrepancies between lower group(73.52) and upper group(75.11)(p<.05). In view of all field, state of tension(t=2.13, p=.048) has difference. 4) While verifying coping style in terms of ego states level between lower and upper students group, In type CP, high level ego states group indicated significant difference on stress coping style area than low leveled group and made such sequences as the central point of problem, In type NP, sequences such as the central point of problem, In type A, the central point of problem, In type FC, hopeful aspect and In type AC, hopeful aspect and indifference were derived significantly different (p<.05). 5) While verifying health state differences in the level of lower and upper ego states, In type FC, low level group(150.29) marked higher point than upper group(145.19), there is remarkable discrepancy and so did whole health state(p=.014), In type AC both mental state(p=.000) and whole health state (p=.015) showed differences. 6) When analyzing correlations between whole students' ego states, copying style and health state, all type of ego state showed differences(p<.001). In correlations between ego state and health state, in type FC physical state had an apex and there are inverse correlations among the other types. Especially, type FC showed inverse correlations with great discrepancies(p<.05). In mental state, type NP(${\gamma}=.198$, p<.001) and type A(${\gamma}=.166$, p<.05) represented straight correlations with remarkable differences. Especially, In type AC showed inverse correlations(${\gamma}=.282$, p<.001). In case of correlations between copying style and health state, indifference(${\gamma}=-.157$) and relaxation of tension(${\gamma}=-.158$) presented great difference(p<.05). In mental state, central point of problem and search for social support showed straight correlations with great discrepancies(p<.05), hopeful aspect and indifference showed inverse correlations with considerable differences(p<.001).

  • PDF