• Title/Summary/Keyword: Medical Simulator

Search Result 169, Processing Time 0.026 seconds

Mixed Reality Based Radiation Safety Education Simulator Platform Development : Focused on Medical Field (혼합현실 기반 방사선 안전교육 시뮬레이터 플랫폼 개발 : 의료분야 중심으로)

  • Park, Hyong-Hu;Shim, Jae-Goo;Kwon, Soon-Mu
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.123-131
    • /
    • 2021
  • In this study, safety education contents for medical radiation workers were produced based on Mixed Reality(MR). Currently, safety training for radiation workers is based on theory. This is insufficient in terms of worker satisfaction and efficiency. To address this, we created ICT(Information and Communication Technologies)-based MR radiation worker safety education content. The expected effect of Mixed Reality worker safety education content is that education is possible without space and time constraints, realistic education is possible without on-site training, and interaction between images is possible through reality-based 3D images, enabling self-directed learning Is that. In addition, learning in a virtual space expressed through HMD(Head Mounted Display) is expected to make education more enjoyable and increase concentration, thereby increasing the efficiency of education. A quantitative evaluation was conducted by an accredited institution and a qualitative evaluation was performed on users, which received excellent evaluation. The MR safety education conducted in this study is expected to be of great help to the education of medical radiation workers, and is expected to develop into a new educational paradigm as online education in accordance with Corona 19 progresses.

Simulation and assessment of 99mTc absorbed dose into internal organs from cardiac perfusion scan

  • Saghar Salari;Abdollah Khorshidi;Jamshid Soltani-Nabipour
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.248-253
    • /
    • 2023
  • Directly, it is not possible to measure the absorbed dose of radiopharmaceuticals in the organs of the human body. Therefore, simulation methods are utilized to estimate the dose in distinct organs. In this study, individual organs were separately considered as the source organ or target organ to calculate the mean absorption dose, which SAF and S factors were then calculated according to the target uptake via MIRD method. Here, 99mTc activity distribution within the target was analyzed using the definition and simulation of ideal organs by summing the fraction of cumulative activities of the heart as source organ. Thus, GATE code was utilized to simulate the Zubal humanoid phantom. To validate the outcomes in comparison to the similar results reported, the accumulation of activity in the main organs of the body was calculated at the moment of injection and cardiac rest condition after 60 min of injection. The results showed the highest dose absorbed into pancreas was about 21%, then gallbladder 18%, kidney 16%, spleen 15%, heart 8%, liver 8%, thyroid 7%, lungs 5% and brain 2%, respectively, after 1 h of injection. This distinct simulation model may also be used for different periods after injection and modifying the prescribed dose.

CT Simulation Technique for Craniospinal Irradiation in Supine Position (전산화단층촬영모의치료장치를 이용한 배와위 두개척수 방사선치료 계획)

  • Lee, Suk;Kim, Yong-Bae;Kwon, Soo-Il;Chu, Sung-Sil;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.165-171
    • /
    • 2002
  • Purpose : In order to perform craniospinal irradiation (CSI) in the supine position on patients who are unable to lie in the prone position, a new simulation technique using a CT simulator was developed and its availability was evaluated. Materials and Method : A CT simulator and a 3-D conformal treatment planning system were used to develop CSI in the supine position. The head and neck were immobilized with a thermoplastic mask in the supine position and the entire body was immobilized with a Vac-Loc. A volumetrie image was then obtained using the CT simulator. In order to improve the reproducibility of the patients' setup, datum lines and points were marked on the head and the body. Virtual fluoroscopy was peformed with the removal of visual obstacles such as the treatment table or the immobilization devices. After the virtual simulation, the treatment isocenters of each field were marked on the body and the immobilization devices at the conventional simulation room. Each treatment field was confirmed by comparing the fluoroscopy images with the digitally reconstructed radiography (DRR)/digitally composite radiography (DCR) images from the virtual simulation. The port verification films from the first treatment were also compared with the DRR/DCR images for a geometrical verification. Results : CSI in the supine position was successfully peformed in 9 patients. It required less than 20 minutes to construct the immobilization device and to obtain the whole body volumetric images. This made it possible to not only reduce the patients' inconvenience, but also to eliminate the position change variables during the long conventional simulation process. In addition, by obtaining the CT volumetric image, critical organs, such as the eyeballs and spinal cord, were better defined, and the accuracy of the port designs and shielding was improved. The differences between the DRRs and the portal films were less than 3 mm in the vertebral contour. Conclusion : CSI in the supine position is feasible in patients who cannot lie on prone position, such as pediatric patienta under the age of 4 years, patients with a poor general condition, or patients with a tracheostomy.

Clinical Application of 3-D Compensator in Head and Neck Cancer (두경부암 환자 치료시 3차원 보상체의 임상 적용에 대한 고찰)

  • Hong, Dong-Ki;Lee, Jeong-Woo;Lee, Koo-Hyun;Park, Kwang-Ho;Kim, Jeong-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.9 no.1
    • /
    • pp.64-70
    • /
    • 1997
  • The goal of radiation treatment planning is to deliver the dose to the patient within $5\%$ of that prescribed. We have often encountered the situation that the area which have not only several irregular contours but also tissue heterogeneities should be treated. With conventional devices such as wedges, missing tissue compensator. there are some limitations to achieve the uniform dose distribution in treatment volume. The use of CT simulator, 3-D planning system, computer-controlled milling machine enables it to deliver the dose uniformally. This report includes the whole procedure which have patient data acquisition 3D planning, computer-controlled milling, performance verification of 3D compensator, and TLD evaluation. We applied it for the treatment of head and heck cancer only. In Spite of the irregular contour and different electron density of tessue, we have achieved the uniformity of the dose distribution within ${\pm}3\%$ relatively. Although there are some problems which are not only verification of performance but uncertainties of using the new treatment device, we believe that the improvement of dosimetry will eliminate the uncertainties of that application. so the other lesions besides head and neck can will be ale to use the 3D compensator to achieve the dose uniformity

  • PDF

Application model research on visualizing anti-inflammation effects by using the virtual cell (가상세포를 활용한 항염증 효능 응용모델 연구)

  • Kim, Chul;Yea, Sang-Jun;Kim, Jin-Hyun;Kim, Sang-Kyun;Jang, Hyun-Chul;Kim, An-Na;Nam, Ky-Youb;Song, Mi-Young
    • Herbal Formula Science
    • /
    • v.18 no.2
    • /
    • pp.227-239
    • /
    • 2010
  • Objective : The purpose of this study was to develop the simulator which can analyze the anti-inflammatory effects of herbs based on e-cell, or the virtual cell. Method : We have ensured the medical herbs and its active compounds by investigating the oriental medicine records and NBCI(Biomedicine database). Also we have developed the web-based search system for confirming database related to anti-inflammation. We have researched the cell signal pathway related with inflammatory response control and established the mathematical model of herb interaction on selected signal pathway in e-cell. Finally we have developed the prototype which can confirm the result of this model visibly. Results : We constructed the database of 62 cases of anti-inflammatory active compounds in 61 cases of medical herbs which have been known anti-inflammation effects in the paper, 16 cases of inflammatory factors, 10 cases of signal pathways related with inflammatory response and 6,834 cases of URL(Uniform Resource Locator) of referenced papers. And we embodied the web-based research system, which can research this database. User can search basic and detailed information of medical plants related with anti-inflammatory by using information system. And user can acquire information on an active compounds, a signal pathway and a link URL of related paper. Among investigated ten pathways, we selected NF-${\kappa}B$, which plays important role in activation of immune system, and we searched the mechanisms of actions of proteins which could be components of this pathway. We reduced total network into IKK-$I{\kappa}B$ - NF-${\kappa}B$, and completed mathematic modeling by using ordinary differential equations and response variables of $I{\kappa}B-NF-{\kappa}B$ signaling model network which is suggested by Baltimore Group. We designed OED(Ordinary Differential Equation) for response of IKK, $I{\kappa}B$, $NF-{\kappa}B$ in e-cell's cytoplasm and nucleus, and measured whether an active compound of medicinal plants which is inputted by an user would have a anti-inflammation effects in obedience to change in concentration over time. The proposed model was verified by using experimental results of the papers which are listed on NCBI.

Performance Evaluation of Transmitting Brainwave Signals in Ad-Hoc Network at Medical Center (의료센터의 애드혹망에서 뇌파전송 성능평가)

  • Jo, Jun-Mo
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.12
    • /
    • pp.216-222
    • /
    • 2010
  • To improve the quality of life, wireless ad-hoc network technologies are considered as one of the key research areas in computer science and healthcare application industries. The ubiquitous healthcare systems also provide alerting mechanisms against ill conditions in real time. This minimizes the need for care-givers and helps the chronically ill and elderly to survive. For the application of the system, supporting the efficient and proper network system is essential. So in this paper, I suggest some hospital network environments including patient mobile nodes continuously sending brainwaves to the server of the hospital area. Finally, the network systems are simulated by OPnet simulator and evaluate the performance among various mobility of the mobile nodes and topologies of the network for the efficient system.

A Study of Design of Hollow Fiber Membrane Modules for using in Artificial Lung by the PZT Actuator

  • Kim, Gi-Beum;Kim, Seong-Jong;Hong, Chul-Un;Lee, Yong-Chul;Kim, Min-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.143-153
    • /
    • 2006
  • The purpose of this work was to assess and quantify the beneficial effects of gas exchange, while testingto the various frequencies of the sinusoidal wave that was excited by the PZT actuator, for patients suffering from acute respiratory distress syndrome (ARDS) or chronic respiratory problems. Also, this paper considered a simulator to design a hollow type artificial lung, and a mathematical model was used to predict a behavior of blood. This simulation was carried out according to the Montecarno's simulation method, anda fourth order Runge-Kutta method was used to solve the equation. The experimental design and procedure are then applied to the construction of a new device to assess the effectiveness of the membrane vibrations. As a result, the vibration method is very effective in the increase of gas transport. The gas exchange efficiency for the vibrating intravascular lung assist device can be increased by emphasizing the following design features: consistent and reproducible fiber geometry, and most importantly, an active means of enhancing convective mixing of water around the hollow fiber membranes. The experimental results showed the effective performance of the vibrating intravascular lung assist device. Also, we concluded that important design parameters were blood flow rates, fiber outer diameter and oxygen pressure drop. Based on the present results, it was believed that the optimal level of blood flow rates was 200$cm^3$/min.

Analysis and Examination of Trends in Research on Medical Learning Support Tools: Focus on Problem-based Learning (PBL) and Medical Simulations

  • Yea, Sang-Jun;Jang, Hyun-Chul;Kim, An-Na;Kim, Sang-Kyun;Song, Mi-Young;Han, Chang-Hyun;Kim, Chul
    • The Journal of Korean Medicine
    • /
    • v.33 no.4
    • /
    • pp.60-68
    • /
    • 2012
  • Objectives: By grasping trends in research, technology, and general characteristics of learning support tools, this study was conducted to present a model for research on Korean Medicine (KM) to make use of information technology to support teaching and learning. The purpose is to improve the future clinical competence of medical personnel, which is directly linked to national health. Methods: With papers and patents published up to 2011 as the objects, 438 papers were extracted from "Web of Science" and 313 patents were extracted from the WIPS database (DB). Descriptive analysis and network analysis were conducted on the annual developments, academic journals, and research fields of the papers, patents searched were subjected to quantitative analysis per application year, nation, and technology, and an activity index (AI) was calculated. Results: First, research on medical learning support tools has continued to increase and is active in the fields of computer engineering, education research, and surgery. Second, the largest number of patent applications on medical learning support tools were made in the United States, South Korea, and Japan in this order, and the securement of remediation technology-centered patents, rather than basic/essential patents, seemed possible. Third, when the results of the analysis of research trends were comprehensively analyzed, international research on e-PBL- and medical simulation-centered medical learning support tools was seen to expand continuously to improve the clinical competence of medical personnel, which is directly linked to national health. Conclusions: The KM learning support tool model proposed in the present study is expected to be applicable to computer-based tests at KM schools and to be able to replace certain functions of national KM doctor license examinations once its problem DB, e-PBL, and TKM simulator have been constructed. This learning support tool will undergo a standardization process in the future.

Force Reflection for a Spine Needle Biopsy Simulator (척추침생검 시뮬레이터를 위한 힘반향 구현)

  • 권동수;경기욱;강흥식;김진국;나종범
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.6
    • /
    • pp.575-581
    • /
    • 2000
  • 본 논문에서는 척추침생검 시뮬레이터에서 사용의 햅틱 디바이스인 PHANToM(sup)TM을 이용하여 사실적인 힘을 구현하는 방법을 보여준다. PHANToM(sup)TM은 툴의 끝부분에서 좌표축 방향으로만 힘을 낼 수 있는 단점이 있으며, 시스템의 구동장치의한계로 인하여 딱딱한 물체에 닿을 때 불안정한 특성을 보인다. 또한 좁은 영역 안에서 복잡한 조직들로 인한 급격한 강도 변화도 시스템의 불안정을 초래한다. 모사되는 힘은 두가지 성분으로 나뉜다. 하나는 바늘이 삽입될 때 바늘의 길이 방향으로 느껴지는 힘으로 생체 조직의 모델을 통해 값이 구해진다. 다른 하나는 바늘이 피부를 뚫고 지나간 이후에 바늘이 초기 삽입 방양을 유지 시켜주는 회전방향 힘으로 피봇을 이용하여 구현하였다. 불안정성 문제와 바늘이 튀어나오는 문제는 램핑 필터와 시간변수를 이용하여 제거하였다. 침생검 과정은 생체조직의 탄성 변형뿐 아니라 파괴가 일어나는 변형이므로 사실적인 힘을 구현하기 위해서 실험 데이터를 이용하여 삽입 깊이에 따라 탄성 계수와 마찰 상수가 변하는 모델을 제안하였다.

  • PDF

The Effects of Horse-back riding Simulation Machine Training on Balance ability in Patients with Stroke (시뮬레이션 훈련이 뇌졸중 환자의 균형 능력에 미치는 영향)

  • Oh, Seung Jun;Ahn, Myung Hwan
    • Journal of Korean Physical Therapy Science
    • /
    • v.20 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Purpose : Investigate the effects of Horse-back riding Simulation Machine training on the Balance ability in Patients with Stroke. Method : The patients were divided to control group(n=18) with conventional rehabilitation conventional rehabilitation 60min/day and experimental group(n=17) with hippotherapy simulator 15 min/day after conventional rehabilitation 45min/day, 5 time/week for 4 weeks. Balance ability of both groups was assessed using Timed Up and Go(TUG), Berg balabce scale(BBS) and Center of pressure area(COPA). In the present result, there was a no significant(P>0.05) Results : The results of this study showed that Horse-back riding Simulation Machine training, after training, had meaningful difference of TUG, BBS and COPA. Conclusion : This study showed that Horse-back riding Simulation Machine training increased balance ability that resulted in enhancement of motor performance.

  • PDF