• Title/Summary/Keyword: Medical Procedures

Search Result 1,710, Processing Time 0.031 seconds

In Vitro Efficacies of Complex of Cedrol and Three Peptides, and Wrinkle Improvements and Lips Volumization effects of Applied Formulations (Cedrol 및 펩타이드 3 종 Complex 의 In Vitro 효능 및 적용 제형의 입술 주름 개선 및 Volumization 효과에 대한 연구)

  • Seongsu Kang;Seung-Hyun Jun;Jinyong Lee;Myoung Jin An;Nae Gyu Kang
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.49 no.4
    • /
    • pp.365-373
    • /
    • 2023
  • Since the lips are a representative facial part that can express human attraction, aesthetic interest in them has always existed in human history. However, as lips age, they tend to form wrinkles, become thinner, and lose their volume. To counteract this phenomenon, medical procedures such as fillers or fat transplantation have been suggested. In this study, we verified that the one of main effective material complex of L G H&H L IPCERIN®, combination of cedrol, a sesquiterpene found in cedarwood, and three peptides (acetyl hexapeptide-8, acetyl tetrapeptide-9, and desamidocollagen) could ameliorate the photo-aging and reduce the wrinkles through in vitro experiments. The possibility of improving collagen and elastin expression in skin fibroblasts and reducing MMP expression under photoaging conditions was verified. In addition, it was confirmed that the amount of fat tissue in the lips can be increased by promoting adipose stem cell differentiation and increasing the amount of fat produced in the in vitro adipose stem cell differentiation experiment. Two weeks of human application tests confirmed that a combination of cedrol and peptides can improve the wrinkles, texture, elasticity, and volume of the lips. This study verified that the combination of cedrol and three peptides can be used as effective cosmetic materials to decrease the various signs of aging in the lips.

Clinical Efficacy of the Transradial Approach in Percutaneous Intervention for a Malfunctioning Arteriovenous Fistula (혈액 투석 동정맥루의 기능 부전에 대한 인터벤션 치료 시 경요골 동맥 접근법의 유용성)

  • Hyun Young Choi;Gyoo-Sik Jung;Hee Kang;Ye Na Kim;Hyung Hwan Moon;Jong Hyouk Yun
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.658-668
    • /
    • 2022
  • Purpose To evaluate the effectiveness of the transradial artery approach (TRA) for treating malfunctioning arteriovenous fistulas (AVFs) in patients on hemodialysis. Materials and Methods A retrospective analysis was conducted in this single-center study of TRA endovascular procedures in 73 patients (43 male and 30 female; mean age of 67.4 years (range, 42-92 years) with malfunctioning AVFs, between January 2008 and April 2019. Patients' baseline and lesion characteristics, technical and clinical success, and complications were evaluated, and functional patency was analyzed using the Kaplan-Meier method. Results Radial artery approaches were successful in all patients. Angioplasty performed using the TRA achieved technical and clinical success rates of 98.6%(72/73) and 91.7%(67/73), respectively. The median primary patency time was 18.8 ± 15.9 months. The primary functional patency rates at 3, 6, and 12 months were 82.1%, 68.6%, and 63.9%, respectively. There were no major complications or adverse events, such as hand ischemia, related to the radial artery approach. Conclusion In selected cases, the TRA can be used complementary to the transvenous approach to treat malfunctioning AVFs.

Conventional Versus Artificial Intelligence-Assisted Interpretation of Chest Radiographs in Patients With Acute Respiratory Symptoms in Emergency Department: A Pragmatic Randomized Clinical Trial

  • Eui Jin Hwang;Jin Mo Goo;Ju Gang Nam;Chang Min Park;Ki Jeong Hong;Ki Hong Kim
    • Korean Journal of Radiology
    • /
    • v.24 no.3
    • /
    • pp.259-270
    • /
    • 2023
  • Objective: It is unknown whether artificial intelligence-based computer-aided detection (AI-CAD) can enhance the accuracy of chest radiograph (CR) interpretation in real-world clinical practice. We aimed to compare the accuracy of CR interpretation assisted by AI-CAD to that of conventional interpretation in patients who presented to the emergency department (ED) with acute respiratory symptoms using a pragmatic randomized controlled trial. Materials and Methods: Patients who underwent CRs for acute respiratory symptoms at the ED of a tertiary referral institution were randomly assigned to intervention group (with assistance from an AI-CAD for CR interpretation) or control group (without AI assistance). Using a commercial AI-CAD system (Lunit INSIGHT CXR, version 2.0.2.0; Lunit Inc.). Other clinical practices were consistent with standard procedures. Sensitivity and false-positive rates of CR interpretation by duty trainee radiologists for identifying acute thoracic diseases were the primary and secondary outcomes, respectively. The reference standards for acute thoracic disease were established based on a review of the patient's medical record at least 30 days after the ED visit. Results: We randomly assigned 3576 participants to either the intervention group (1761 participants; mean age ± standard deviation, 65 ± 17 years; 978 males; acute thoracic disease in 472 participants) or the control group (1815 participants; 64 ± 17 years; 988 males; acute thoracic disease in 491 participants). The sensitivity (67.2% [317/472] in the intervention group vs. 66.0% [324/491] in the control group; odds ratio, 1.02 [95% confidence interval, 0.70-1.49]; P = 0.917) and false-positive rate (19.3% [249/1289] vs. 18.5% [245/1324]; odds ratio, 1.00 [95% confidence interval, 0.79-1.26]; P = 0.985) of CR interpretation by duty radiologists were not associated with the use of AI-CAD. Conclusion: AI-CAD did not improve the sensitivity and false-positive rate of CR interpretation for diagnosing acute thoracic disease in patients with acute respiratory symptoms who presented to the ED.

A novel method for determining dose distribution on panoramic reconstruction computed tomography images from radiotherapy computed tomography

  • Hiroyuki Okamoto;Madoka Sakuramachi;Wakako Yatsuoka;Takao Ueno;Kouji Katsura;Naoya Murakami;Satoshi Nakamura;Kotaro Iijima;Takahito Chiba;Hiroki Nakayama;Yasunori Shuto;Yuki Takano;Yuta Kobayashi;Hironori Kishida;Yuka Urago;Masato Nishitani;Shuka Nishina;Koushin Arai;Hiroshi Igaki
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.129-137
    • /
    • 2024
  • Purpose: Patients with head and neck cancer (HNC) who undergo dental procedures during radiotherapy (RT) face an increased risk of developing osteoradionecrosis (ORN). Accordingly, new tools must be developed to extract critical information regarding the dose delivered to the teeth and mandible. This article proposes a novel approach for visualizing 3-dimensional planned dose distributions on panoramic reconstruction computed tomography (pCT) images. Materials and Methods: Four patients with HNC who underwent volumetric modulated arc therapy were included. One patient experienced ORN and required the extraction of teeth after RT. In the study approach, the dental arch curve (DAC) was defined using an open-source platform. Subsequently, pCT images and dose distributions were generated based on the new coordinate system. All teeth and mandibles were delineated on both the original CT and pCT images. To evaluate the consistency of dose metrics, the Mann-Whitney U test and Student t-test were employed. Results: A total of 61 teeth and 4 mandibles were evaluated. The correlation coefficient between the 2 methods was 0.999, and no statistically significant difference was observed (P>0.05). This method facilitated a straightforward and intuitive understanding of the delivered dose. In 1 patient, ORN corresponded to the region of the root and the gum receiving a high dosage (approximately 70 Gy). Conclusion: The proposed method particularly benefits dentists involved in the management of patients with HNC. It enables the visualization of a 3-dimensional dose distribution in the teeth and mandible on pCT, enhancing the understanding of the dose delivered during RT.

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

Analysis of the Issues received by Quality Improvement Department and their Management in a Medical Center (일 의료원의 통합 고충처리센터 접수 내용과 이에 대한 해결방안 분석)

  • Tark, Kwan-Chul;Park, Hyun-Ju;Chun, Ja-Hae;Kang, Eun-Sook;Moon, Ju-Young;Choi, Mi-Young;Kim, Hyun-Ju;Kang, Jin-Kyung
    • Quality Improvement in Health Care
    • /
    • v.7 no.1
    • /
    • pp.118-131
    • /
    • 2000
  • Background : A continuous healthcare quality improvement is needed to provide high quality healthcare service as well as to maintain trust in terms of satisfying the needs of the patients. Recently it also became an essential issue. in hospital management, recognized for it's competitive potentiality among healthcare organization groups. This study was conducted to analyze patient complaints and issues received by the Quality Improvement Department. Its purpose is to improve healthcare qualities within the hospital, as well as establish policies and appropriate strategies in hospital management. Method : From July 1st to September 30th of the year 1999, we analyzed all complaints and issues made by various patients and their families, which were received through 24 hour phone consultation, numerous suggestion boxes, letters and E-mails, The issues were classified into 16 different categories based on a Patient Satisfaction Assessment Tool. All data were segregated according to the departmental frequencies and their contents. To come up with for environmental and patient satisfaction improvement, all complaints or issues were communicated with hospital administrators, medical and nursing staff and employees. Comprehensive customer satisfaction activities including improving phone etiquette were discussed in Customer Satisfaction Team, CQI Team and each Department. All opportunities for improvement were implemented. Feedback actions were discussed. Results : A total of 317 cases were collected. Issues regarding parking and other accommodation facilities were most common complaints that were 14.5% of total. Issues regarding admission rooms (10.7%), admission procedures (10.7%), waiting room environment (8.8%), nurses and nurse assistants (7.6%), physicians (6.6%) and others (23%) followed. Thirteen of 45 departments received more than 8 complaints. The Nursing Department had the most complaint, receiving 9.8% of total complaints. Complaints regarding the Nursing Department were predominantly related to the environment of patient rooms. The Department of Psychiatry for phone etiquette (4.7%), Department of Otolaryngology for the nursing staff's attitude and phone etiquette (4.4%), and the Admission Department followed. As a part of efforts to improve patient satisfaction, a new parking structure was built and reallocation of the parking space was done. Renovation of other accommodation facilities were carried out by hospital administration, Monthly phone call and answering attitude survey was done by QI Department. Based on this survey we made a phone etiquette manual and distributed throughout the hospital. Compare to the last year, Patient Satisfaction Index measured by Korea Productivity Center using National Customer Satisfaction Index was improved 7 points. According to our organization's own study, we confirmed the phone etiquette was improved 11% than last year. Conclusions : Issues related to parking and other accommodation facilities ranked first followed by complaints made regarding the patient care area, the admission and cashier process, and nurses' and doctors' attitude. The Nursing and Psychiatry Departments need improvement regarding phone etiquette. Results were shared and played a vital role in policymaking and strategic planning of the hospital. It is imperative that we keep our database updated by listening to and solving the needs of each patient. The CQI activities can be achieved only by full commitment of the hospital top management supported by related personal.

  • PDF

Finite Element Method Modeling for Individual Malocclusions: Development and Application of the Basic Algorithm (유한요소법을 이용한 환자별 교정시스템 구축의 기초 알고리즘 개발과 적용)

  • Shin, Jung-Woog;Nahm, Dong-Seok;Kim, Tae-Woo;Lee, Sung Jae
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.815-824
    • /
    • 1997
  • The purpose of this study is to develop the basic algorithm for the finite element method modeling of individual malocclusions. Usually, a great deal of time is spent in preprocessing. To reduce the time required, we developed a standardized procedure for measuring the position of each tooth and a program to automatically preprocess. The following procedures were carried to complete this study. 1. Twenty-eight teeth morphologies were constructed three-dimensionally for the finite element analysis and saved as separate files. 2. Standard brackets were attached so that the FA points coincide with the center of the brackets. 3. The study model of a patient was made. 4. Using the study model, the crown inclination, angulation, and the vertical distance from the tip of a tooth was measured by using specially designed tools. 5. The arch form was determined from a picture of the model with an image processing technique. 6. The measured data were input as a rotational matrix. 7. The program provides an output file containing the necessary information about the three-dimensional position of teeth, which is applicable to several finite element programs commonly used. The program for a basic algorithm was made with Turbo-C and the subsequent outfile was applied to ANSYS. This standardized model measuring procedure and the program reduce the time required, especially for preprocessing and can be applied to other malocclusions easily.

  • PDF

Dose Verification Using Pelvic Phantom in High Dose Rate (HDR) Brachytherapy (자궁경부암용 팬톰을 이용한 HDR (High dose rate) 근접치료의 선량 평가)

  • 장지나;허순녕;김회남;윤세철;최보영;이형구;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.15-19
    • /
    • 2003
  • High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a phantom. In this study, the phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the phantom were then compared with the treatment planning system for the dose verification. The phantom needs to be designed such that the dose distributions can be quantitatively evaluated by utilizing the dosimeters with a high spatial resolution. Therefore, the small size of the thermoluminescent dosimeter (TLD) chips with a dimension of <1/8"and film dosimetry with a spatial resolution of <1mm used to measure the radiation dosages in the phantom. The phantom called a pelvic phantom was made from water and the tissue-equivalent acrylic plates. In order to firmly hold the HDR applicators in the water phantom, the applicators were inserted into the grooves of the applicator holder. The dose distributions around the applicators, such as Point A and B, were measured by placing a series of TLD chips (TLD-to-TLD distance: 5mm) in the three TLD holders, and placing three verification films in the orthogonal planes. This study used a Nucletron Plato treatment planning system and a Microselectron Ir-192 source unit. The results showed good agreement between the treatment plan and measurement. The comparisons of the absolute dose showed agreement within $\pm$4.0 % of the dose at point A and B, and the bladder and rectum point. In addition, the relative dose distributions by film dosimetry and those calculated by the planning computer show good agreement. This pelvic phantom could be a useful to verify the dose calculation algorithm and the accuracy of the image localization algorithm in the high dose rate (HDR) planning computer. The dose verification with film dosimetry and TLD as quality assurance (QA) tools are currently being undertaken in the Catholic University, Seoul, Korea.

  • PDF

Future Development Strategies for KODISA Journals : Overview of 2017 and Strategic Plans for the Future (KODISA 학술지 성장전략: 2017 개관 및 미래 성장개요)

  • Hwang, Hee-Joong;Shin, Dong-Jin;Lee, Jung-Wan;Kim, Dong-Ho;Lee, Jong-Ho;Kim, Byung-Goo;Kim, Tae-Joong;Lee, Yong-Ki;Suh, Eung-Kyo;Kang, Min-Soo;Seo, Won-Jae;Kim, Jong-Jin;Zhang, Fan;Su, Shuai;Youn, Myoung-Kil
    • Journal of Distribution Science
    • /
    • v.16 no.5
    • /
    • pp.83-90
    • /
    • 2018
  • Purpose - Journals of Korea Distribution Science Association (KODISA) made great efforts in responding to the constant shifts in academic paradigms and in producing synergetic effects among KODISA journals to achieve the goal of maintaining their status in the world's reputable scholarly journals. The aim of this study is to analyze the current practice and performance of KODISA journals and develop strategies that will continuously meet and respond to the changes and success in the future. Research design, data, and methodology - This is a case study, an analytical approach, which focuses on analyzing current and previous strategies, practices, and performances of the four major journals of KODISA and the association. The organizational structure, including election and terms of KODISA officers, new membership, and members of editorial board, is discussed and analyzed. The citation, submission, publication, and rejection rates of all four journals are examined, and the progress, including the status of indexing of each journal, is discussed. Results - The analysis indicates that KODISA has significantly invested its resources into improving its journals and attracting new members. The analysis also shows the strategy of the organizational structure, which includes election and terms of officers and editorial board members that implemented over the years, was successful. Both Journal of Distribution Science (JDS) and Journal of Finance, Economics, and Business (JAFEB) are indexed in SCOPUS, with East Asian Journal of Business Management (EAJBM) in the final stage of the SCOPUS indexing evaluation, and International Journal of Industrial Distribution and Business (IJIDB) will complete and submit their indexing evaluation materials to SCOPUS this summer. Conclusions - The success and progress of KODISA and its journals clearly support the need for continuous development, analysis, revision, and implementation of strategies. Based on the analysis, conducting the annual performance reviews of the association and its journals and planning and strategizing based on the reviews since 2011 have greatly contributed to the overall success. In terms of meeting the short term strategy, KODISA has to continue developing relationships with relevant and appropriate scholarly/academic associations to expand the scope of its business, establishing independence of each journal and its respective procedures and practices and improving the quality of the journals and their publications through KODISA's international conferences.

Medico-Surgical Cooperative Treatment of Pulmonary Atresia with Intact Ventricular Septum (심실중격 결손이 없는 폐동맥 폐쇄의 내과-외과적 협동치료)

  • Kim, Kyeong Sik;Kweon, Byeong Chul;Lee, Jong Kyun;Choi, Jae Young;Sul, Jun Hee;Lee, Sung Kyu;Park, Young Whan;Cho, Bum Koo
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.3
    • /
    • pp.250-258
    • /
    • 2003
  • Purpose : The actual clinical examples of co-appliance of catheter intervention with surgical procedures in the treatment of pulmonary atresia with an intact ventricular septum(PA/IVS) which we have experienced in our institution are here shown, and the anatomical and hemodynamical profiles between each method is compared. Methods : Medical records of 33 patients with PA/IVS who underwent various treatment from January, 1995 to December, 2000 were reviewed for a retrograde study. Results : In three out of 10 patients who underwent percutaneous balloon pulmonary valvotomy (PPV), residual pulmonary stenosis were observed in their out patient department(OPD) follow-ups, eventually necessitatig balloon pulmonary valvuloplasty(BPV). One out of three patients exhibited deterioration of tricuspid regurgitation after BPV, requiring surgical tricuspid annuloplasty(TAP). Two out of the seven patients who received primarily surgical right ventricle outlet tract(RVOT) repair without any systemic-pulmonary shunt or intervention needed additional intervention employing cardiac catheterization after operation. Two patients received interventional catheterization before surgical RVOT repair. In five out of 11 cases of Fontan type operation, coil embolization of collateral circulation was done before total cavo-pulmonary connection(TCPC), and in three cases, interventional catheterization was needed after TCPC. Conclusion : Both medical and surgical treatment modalities are widely used in management of PA/IVS patients, and recent results prove that medico-surgical cooperative treatment is essential.