• Title/Summary/Keyword: Medical Procedures

Search Result 1,710, Processing Time 0.031 seconds

Experiences of Tracheal Procedure Assisted by Extracorporeal Membrane Oxygenator

  • Kim, Ji Eon;Jung, Sung-Ho;Ma, Dae Sung
    • Journal of Chest Surgery
    • /
    • v.46 no.1
    • /
    • pp.80-83
    • /
    • 2013
  • We report on the application of a venovenous type extracorporeal membrane oxygenator (ECMO) in high-risk tracheal procedures in six cases consisting of five patients with tracheal stenosis. An ECMO should be helpful for preventing respiratory emergency during a tracheal procedure.

An Experimental Study on Hepatic Ablation using an Internally Cooled Needle Electrodes in Radiofrequency Ablation (고주파 열치료(Rodiofrequency ablotion)에 이용되는 내부 냉각 전극(Internally cooled needle electrodes)를 이용한 간 소작법의 유용성 실험)

  • Han Jung Hwan;Ahn Jung Hyun;Park Won Sik
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.30 no.1
    • /
    • pp.58-62
    • /
    • 2004
  • The purpose of this study was to determine the factors influencing on the size of Radiofrequency ablation using an internally cooled needle electrodes in cattle liver. Ablation procedures involved the use of cool-tip RF system generator and internally coo

  • PDF

Performance Evaluation of Computed Tomographic Equipment (CT장치의 성능평가에 관한 연구)

  • Han Dong Kyoon;Kim Moon Chan;Yang Han Joon;Ko Shin Kwan
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.66-85
    • /
    • 2001
  • In medical equipments as complex as a computed tomographic equipment, routine quality control procedures are essential to the detection of small pathologic change in soft tissue as well as and the maintenance of optimal image quality. This study was condu

  • PDF

Treatment of phlegmonous esophagitis in various patients: a case series

  • Han Sol Lee;Chul Ho Lee;Yun-Ho Jeon
    • Journal of Yeungnam Medical Science
    • /
    • v.40 no.4
    • /
    • pp.442-447
    • /
    • 2023
  • Acute phlegmonous esophagitis (APE) is a rare and fatal disease. Phlegmonous infection involves the submucosal layer and muscularis propria but not the mucosal layer. Because surgery is not the first treatment option for this disease, an accurate diagnosis is crucial. Herein, we report three cases of APE with various clinical features. All patients were successfully treated with antibiotics and appropriate medical procedures.

Dental needle foreign body in the neck: a case report

  • Mohammed, Hassen;Shallik, Nabil;Barsoum, Mina;Abdulla, Majid Al;Dogan, Zynel;Ahmed, Hassan Haidar;Moustafa, Abbas
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.20 no.2
    • /
    • pp.83-87
    • /
    • 2020
  • Foreign body (FB) ingestion is commonly seen in the ear nose and throat (ENT) field, with different presentations and sequelae. FBs can arrest in the upper aerodigestive tract or continue further down into either the airway tract to the bronchus or the digestive tract to the intestines. The pathway of an FB depends on the size and shape of the FB and how sharp its edges are. Since the 20th century, the use of disposable stainless-steel needles in the oral cavity has proven to be an effective and safe method for performing various intraoral procedures like dental infiltration or a root canal wash. Complications from their use are rare. Generally, dental needle breakages are caused by patients biting the needle, incorrect injection techniques, or inadequate preventative measures. The sudden movement of a patient during a procedure is one of the most common causes of breakage. Occasionally, needles are swallowed during dental procedures such as a root canal. Here, we report a case of a patient that swallowed a broken needle during a dental procedure. A few days later, the patient presented with neck pain, swelling, and a FB sensation. When the patient presented, she claimed that her symptoms had onset after consuming a meal containing duck meat. Initially, the patient was diagnosed as having ingested a duck bone. However, intraoperatively, the FB was discovered to be an injection needle that had migrated from the throat to the neck.

Empirical Treatment of Highly Suspected Nontuberculous Mycobacteria Infections Following Aesthetic Procedures

  • Kim, Hyung Rok;Yoon, Eul Sik;Kim, Deok Woo;Hwang, Na Hyun;Shon, Yoo Seok;Lee, Byung Il;Park, Seung-Ha
    • Archives of Plastic Surgery
    • /
    • v.41 no.6
    • /
    • pp.759-767
    • /
    • 2014
  • Background Infection caused by nontuberculous mycobacteria (NTM) has been increasing. Awareness of this infection is crucial yet problematic. Delayed management may lead to destructive results. We empirically treated a series of patients with clinical suspicion of NTM infection prior to the identification of the pathogen. Methods A total of 12 patients who developed surgical site infections between January 2011 and February 2014 were reviewed. Patients with a skin and subcutaneous infection resistant to standard management over two weeks, and previous history of aesthetic procedures within three months were regarded as highly suspected of having an NTM infection. A variety of diagnostic modalities were examined simultaneously, along with starting empirical treatment including a combination of clarithromycin and moxifloxacin, and surgical debridement. Results All wounds healed completely within 4 weeks. The mean follow-up duration was 7.2 months, and none of the patients developed relapse. Specific NTM pathogens were identified in six patients. Eight patients showed caseating granuloma implying an NTM infection. One patient showed an uncommon Stenotrophomonas infection, which was successfully treated. Three patients had no evidence of a pathogen despite repeated microbial tests. Complications such as scarring, pigmentation, and disfigurement were common in all the patients. Conclusions NTM should be considered in the differential diagnosis of an unusual skin and soft-tissue infection. We propose an empirical regimen of clarithromycin and moxifloxacin as an efficient treatment option for an NTM infection.

Surgical Outcomes of Congenital Atrial Septal Defect Using da VinciTM Surgical Robot System

  • Kim, Ji Eon;Jung, Sung-Ho;Kim, Gwan Sic;Kim, Joon Bum;Choo, Suk Jung;Chung, Cheol Hyun;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • v.46 no.2
    • /
    • pp.93-97
    • /
    • 2013
  • Background: Minimally invasive cardiac surgery has emerged as an alternative to conventional open surgery. This report reviews our experience with atrial septal defect using the da VinciTM surgical robot system. Materials and Methods: This retrospective study included 50 consecutive patients who underwent atrial septal defect repair using the da VinciTM surgical robot system between October 2007 and May 2011. Among these, 13 patients (26%) were approached through a totally endoscopic approach and the others by mini-thoracotomy. Nineteen patients had concomitant procedures including tricuspid annuloplasty (n=10), mitral valvuloplasty (n=9), and maze procedure (n=4). The mean follow-up duration was $16.9{\pm}10.4$ months. Results: No remnant interatrial shunt was detected by intraoperative or postoperative echocardiography. The atrial septal defects were mainly repaired by Gore-Tex patch closure (80%). There was no operative mortality or serious surgical complications. The aortic cross clamping time and cardiopulmonary bypass time were $74.1{\pm}32.2$ and $157.6{\pm}49.7$ minutes, respectively. The postoperative hospital stay was $5.5{\pm}3.3$ days. Conclusion: The atrial septal defect repair with concomitant procedures like mitral valve repair or tricuspid valve repair using the da VinciTM system is a feasible method. In addition, in selected patients, complete port access can be helpful for better cosmetic results and less musculoskeletal injury.

The Longitudinal Trend of Cardiac Surgery in Korea from 2003 to 2013

  • Lee, Kyeong Soo;Kim, Chang Suk;Park, Jong Heon;Hwang, Tae Yoon;Kim, Sang Won;Sim, Sung Bo;Lee, Kun Sei
    • Journal of Chest Surgery
    • /
    • v.49 no.sup1
    • /
    • pp.1-13
    • /
    • 2016
  • Background: The purpose of this study was to investigate longitudinal changes of the utilization of operational and surgical medical care inside and outside a metropolitan area over 10 years, analyzing the residential areas of patients and the locations of medical facilities for major cardiovascular surgery. Methods: Data analysis was conducted by classifying the addresses of patients and the locations of medical care facilities of metropolitan cities and provinces, using data from the National Health Insurance Corporation from January 2003 to December 2013. Results: There is serious concentration of major heart surgery to medical facilities in Seoul; this problem has not improved over time. There were differences in percentages of surgical procedures performed in the metropolitan areas according to major diseases. In the case of Busan and Daegu provinces, at least 50% of the patients underwent surgery in medical facilities in the city, but there are other regions where the percentage is less than 50%. In the case of provinces, the percentage of surgical procedures performed in medical facilities in Seoul or nearby metropolitan cities is very high. Conclusion: Policies to strengthen the regional capabilities of heart surgery and to secure human resources are required to mitigate the concentration of patients in the capital area. Many regional multi-centers must be designated to minimize unnecessary competition among regional university hospitals and activate a win-win partnership model for medical services.

Clinical and Radiogical Outcomes of Endovascular Detachable Coil Embolization in Paraclinoid Aneurysms : A 10-Year Experience

  • Jin, Sung-Chul;Kwon, Do-Hoon;Ahn, Jae-Sung;Kwun, Byung-Duk;Song, Young;Choi, Choong-Gon
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.1
    • /
    • pp.5-10
    • /
    • 2009
  • Objective : Direct surgical clipping of paraclinoid aneurysms poses technical challenges to even very experienced neurosurgeons, making endovascular treatment an alternative treatment modality in many centers. We have therefore retrospectively evaluated the safety and efficacy of endovascular detachable coil embolization of paraclinoid aneurysms. Methods : From June 1997 to June 2007, 65 patients underwent endovascular detachable coiling for 67 paraclinoid aneurysms (of which 9 were ruptured and 58 were unruptured) in our institute. Their medical records, radiological images and readings, and operation records were reviewed retrospectively. Results : After the initial embolization procedure, complete occlusion was achieved in 29 (43.3%) of the aneurysms treated by endovascular detachable coiling. Six aneurysms required retreatment, with two each requiring one, two, or three additional endovascular procedures. Fifty-five (82.1%) aneurysms were measured by three-dimensional time of flight (TOF) magnetic resonance images (MRI) or transfemoral cerebral angiography (TFCA) at a mean follow-up of 29.7 months (range from 4 to 94 months), with 39 aneurysms (70.9%) showing complete occlusion. Thromboembolic events (3.8%) were the most frequent complication. Rupture did not occur during or after any of the procedures. According to the Glasgow Outcome Scale (GOS), 98.4% of the patients treated by coil embolization had a score of 4 or 5. Conclusion : Our results indicate that endovascular detachable coiling is a safe and effective treatment modality in paraclinoid aneurysms.

Aortic Valve Replacement Using Continuous Suture Technique in Patients with Aortic Valve Disease

  • Choi, Jong Bum;Kim, Jong Hun;Park, Hyun Kyu;Kim, Kyung Hwa;Kim, Min Ho;Kuh, Ja Hong;Jo, Jung Ku
    • Journal of Chest Surgery
    • /
    • v.46 no.4
    • /
    • pp.249-255
    • /
    • 2013
  • Background: The continuous suture (CS) technique has several advantages as a method for simple, fast, and secure aortic valve replacement (AVR). We used a simple CS technique without the use of a pledget for AVR and evaluated the surgical outcomes. Materials and Methods: Between October 2007 and 2012, 123 patients with aortic valve disease underwent AVR alone (n=28) or with other concomitant cardiac procedures (n=95), such as mitral, tricuspid, or aortic surgery. The patients were divided into two groups: the interrupted suture (IS) group (n=47), in which the conventional IS technique was used, and the CS group (n=76), in which the simple CS technique was used. Results: There were two hospital deaths (1.6%), which were not related to the suture technique. There were no significant differences in cardiopulmonary bypass time or aortic cross-clamp time between the two groups for AVR alone or AVR with concomitant cardiac procedures. In the IS group, two patients had prosthetic endocarditis and one patient experienced significant perivalvular leak. These patients underwent reoperations. In the CS group, there were no complications related to the surgery. Postoperatively, the two groups had similar aortic valve gradients. Conclusion: The simple CS method is useful and secure for AVR in patients with aortic valve disease, and it may minimize surgical complications, as neither pledgets nor braided sutures are used.