Development of a Web-Based Program for Cross-Calibration and Record Management of Radiation Measuring Equipment

  • Park, So Hyun;Lee, Rena;Kim, Kyubo;Ahn, Sohyun;Lim, Sangwook;Cho, Samju
    • Progress in Medical Physics
    • /
    • v.30 no.2
    • /
    • pp.59-63
    • /
    • 2019
  • Purpose: To manage radiation measurement equipment, a web-based management program has been developed in this study. Materials and Methods: This program is based on a web service and Java Server Pages (JSP) and employs compatibility and accessibility. Results: The first step in the workflow has been designed to create accounts for each user or organization and to log in. The program consists of two parts: fields for listed instruments, and measurement information. The instruments for measuring radiation listed in this program are as follows: ionization chambers, survey meters, thermometers, barometers, electrometers, and phantoms. Instrument properties can be put in the recording fields and browsing for associated instruments can be performed. The main part of the program is the cross-calibration for each ion chamber. For instance, the ionization chamber to be used as a relative dosimeter can be registered by cross-calibration data with a reference chamber calibrated by an accredited laboratory. This program supports methods using the central axis transfer theory for cross-calibration for the ionization chambers. The reference and field ionization chambers were placed in a solid water phantom along the beam central axis at two different depths, and then the positions were switched. Each measured value was used for calculating the cross-calibration factor. Conclusions: Because many instruments are used and managed in radiation oncology departments, systematic, traceable recording is very important. The web-based program developed in this study is expected to be used effectively in the maintenance of radiation measurement instruments.

Root surface roughness following mechanical instrumentation, in vitro 3 dimensional planimetric study (기구조작후 치근표면의 조도에 관한 연구; 3차원 측정기틀 이용한 in vitro 연구)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.4
    • /
    • pp.823-828
    • /
    • 1998
  • A primary goal of periodontal therapy is the creation of root surfaces that are free of plaque and calculus. It is not yet to be determined whether it is desirable to have a smooth root surface after treatment. It is also not clear what degree of roughness result from different instruments. In the present study various instruments for root surface debridement were evaluated. 20 extracted teeth were utilized, and the teeth were treated with one of the following instrument: Gracey curette, Perio Clean, and piezo ultrasonic device(Setlec, P Max) with general scaler tip, curette-like tip, and diamond tip. 3 dimensional planimetric device(Accura) was used to evaluate the average surface roughness. It was demonstrated hand and power-driven instruments did not have a significant difference in roughness of the root surface following instrumentation. And ultrasonic scaler tip tended to make a most smooth surface than other instruments. The possible reasons of the result were discussed.

  • PDF

Use of Home Nursing Therapy and Need of Home Care Equipments (가정간호환자의 치료적 간호서비스 제공과 의료기구 사용 및 요구도)

  • Ryu, Ho-Shin;Park, Chai-Soon;Kim, In-A;Kwon, Young-Dae;Kang, Sung-Wook
    • Research in Community and Public Health Nursing
    • /
    • v.19 no.2
    • /
    • pp.157-166
    • /
    • 2008
  • This study was conducted with whole home care nurses nationwide to provide secondary analyzed data to understand on their usage of medical equipments and their need of them for a month. This study found that treatments given by home care nurses were nelaton catheterization, bladder washing/urethral washing, newborn care, exchange and care for nasogastric tube and suction in that order of frequency. Second, instruments and equipments used for home care were reported to be stethoscope, patient monitor, blood pressure measuring equipment, air flotation mattresses, beds for patients, mattresses, suctioning device sets, enteral feeding equipment and dressing set in that oder of frequency. Moreover, need assessment of medical instruments and equipments showed renal dialysis was most needed and patient monitor, blood pressure measuring equipment, enteral feeding equipment, solution and other supplies for renal dialysis and beds for patient were necessary in that order. In conclusion, the results of this study investigating special treatments and medical instruments and equipments used for home care patients and analyzing patients' need, were expected to be useful for expansion of application of long-term care insurance for the elderly and health insurance as well as for quality control of home care and development of medial instruments and equipments used at home.

  • PDF

The Statistical Analyses of Oriental Medical Office of Sub-health Center During Recent 3 years (최근 3년간 보건지소 한방진료실의 현황에 대한 통계적 연구)

  • Roh, Hong-Pyo;Sul, In-Chan;Kim, Yoon-sik
    • Journal of Haehwa Medicine
    • /
    • v.13 no.2
    • /
    • pp.213-219
    • /
    • 2004
  • Objective: We investigated the actual condition of oriental medical office in Sub-health Center. Method: We classified patients who visited an oriental medical office in a sub-health center of Jeollanam-do during recent 3 years, according to age, time(year), sex, disease, medical instruments, insurance, living condition... etc and studied statistical researches. Result: Almost all patients who visited an oriental medical office in a sub-health center were in 50, 60s. The number of patients were on the decrease. The number of female patients was 2.4 times more than the number of male patients. The most diseases of patients in sub-health center were diseases in connection with bones and sinews system. Generally, medical instruments depended on acupuncture. Conclusion; These results provide actual informations about condition of oriental medical office in Sub-health Center. Oriental medical doctors and offices of sub-health center are supposed to contribute to society, however essentially many problems exist. Public medical doctors of oriental medicine and local administration must renew their efforts for health of people in farming and fishing villages.

  • PDF

Internal Consistency and Concurrent Validity of Korean Language Version of WHODAS 2.0: 12 Item-Self Administered

  • Lee, Hae-Jung;Kim, Da-Jeong
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.6
    • /
    • pp.23-29
    • /
    • 2011
  • Purpose: The aim of this study was to validate the Korean version of World Health Organization Disability Assessment Schedule 2.0 (KWHODAS 2.0) in 12 item-self administered version (12-self). Methods: The KWHODAS 2.0 and Korean Functional Rating index (KFRI) were tested for internal consistency, ceiling and floor effects, and concurrent validity in 111 patients with low back pain and/or neck pain. Results: A very high level of internal consistency was shown for both instruments; ${\alpha}$=0.96 with KWHODAS 2.0; 12-self and ${\alpha}$=0.97 for KFRI. No ceiling and/or floor effects were found in both the instruments. The KWHODAS 2.0 and KFRI were highly correlated (r=0.77), and the relationship of each item between KWHODAS 2.0 and KFRI was ranging from r=0.09 to 0.72. Conclusion: We conclude that the KWHODAS 2.0: 12-self and KFRI are reliable and are valid instruments for the measurement of disability in Korean speaking patients with low back and/or neck pain. Both instruments, the KWHODAS 2.0; 12-Self and KFRI are now suitable for use in clinical practice and research applications.

The Obturator Guiding Technique in Percutaneous Endoscopic Lumbar Discectomy

  • Han, In-Ho;Choi, Byung-Kwan;Cho, Won-Ho;Nam, Kyoung-Hyup
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.3
    • /
    • pp.182-186
    • /
    • 2012
  • In conventional percutaneous disc surgery, introducing instruments into disc space starts by inserting a guide needle into the triangular working zone. However, landing the guide needle tip on the annular window is a challenging step in endoscopic discectomy. Surgeons tend to repeat the needling procedure to reach an optimal position on the annular target. Obturator guiding technique is a modification of standard endoscopic lumbar discectomy, in which, obturator is used to access triangular working zone instead of a guide needle. Obturator guiding technique provides more vivid feedback and easy manipulation. This technique decreases the steps of inserting instruments and takes safer route from the peritoneum.

Role of Single Port Rigid Thoracoscopy in Undiagnosed Pleural Effusion

  • Jagdish Rawat;Anil Kumar;Parul Mrigpuri;Dev Singh Jangpangi;Abhay Pratap Singh;Ritisha Bhatt
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.2
    • /
    • pp.194-199
    • /
    • 2024
  • Background: In recent years, medical thoracoscopy has been well established to play an important role in undiagnosed pleural effusion; however, this procedure is underutilized due to limited availability of the instruments it requires. This study analysed the outcome of single port rigid thoracoscopy in patients with undiagnosed pleural effusions. Methods: This study retrospectively analysed the outcomes of all patients with undiagnosed pleural effusion presenting to our centre between 2016 to 2020 who underwent single port rigid medical thoracoscopy as a diagnostic procedure. Results: In total, 92 patients underwent single port rigid medical thoracoscopy. The most common presenting symptom was shortness of breath. A majority of the patients had lymphocytic exudative pleural effusion. The average biopsy sample size was 18 mm, and no major complication was reported in any of the patients. Conclusion: Single port rigid thoracoscopy is a safe and well-tolerated procedure that yields a biopsy of a larger size with high diagnostic yield. Moreover, the low cost of the instruments required by this procedure makes it particularly suited for use in developing countries.

Radiological and Clinical Results of Laminectomy and Posterior Stabilization for Severe Thoracolumbar Burst Fracture : Surgical Technique for One-Stage Operation

  • Kim, Myeong-Soo;Eun, Jong-Pil;Park, Jeong-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.3
    • /
    • pp.224-230
    • /
    • 2011
  • Objective : This study aimed to show the possibility of neural canal enlargement and restoration of bony fragments through laminectomy and minimal facetectomy without pediculectomy or an anterior approach, and also to prove the adequacy of posterior stabilization of vertebral deformities after thoracolumbar bursting fracture. Methods : From January 2003 to June 2009, we experienced 45 patients with thoracolumbar burst fractures. All patients enrolled were presented with either a neural canal compromise of more than 40% with a Benzel-Larson Grade of VI, or more than 30% compromise with less than a Benzel-Larson Grade of V. Most important characteristic of our surgical procedure was repositioning retropulsed bone fragments using custom-designed instruments via laminectomy and minimal facetectomy without removing the fractured bone fragments. Beneath the dural sac, these custom-designed instruments could push the retropulsed bone fragments within the neural canal after the decompression and bone fragment repositioning. Results : The mean kyphotic deformities measured preoperatively and at follow-up within 12 months were 17.7 degrees (${\pm}6.4$ degrees) and 9.6 degrees (${\pm}5.2$ degrees), respectively. The mean midsagittal diameter improved from 8.8 mm (${\pm}2.8$ mm) before surgery to 14.2 mm (${\pm}1.6$ mm) at follow-up. The mean traumatic vertebral body height before surgery was 41.3% (${\pm}12.6%$). At follow-up assessment within 12 months, this score showed a statistically significant increase to 68.3% (${\pm}12.8%$). Neurological improvement occurred in all patients. Conclusion : Though controversy exists in the treatment of severe thoracolumbar burst fracture, we achieved effective radiological and clinical results in the cases of burst fractures causing severe canal compromise and spinal deformity by using this novel custom-designed instruments, via posterior approach alone.

Radiological Characteristics of Materials Used in 3-Dimensional Printing with Various Infill Densities

  • Park, So-Yeon;Choi, Noorie;Choi, Byeong Geol;Lee, Dong Myung;Jang, Na Young
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.155-159
    • /
    • 2019
  • Radiological properties of newly introduced and existing 3-dimensional (3D) printing materials were evaluated by measuring their Hounsfield units (HUs) at varying infill densities. The six materials for 3D printing which consisted of acrylonitrile butadiene styrene (ABS), a unique ABS plastic blend manufactured by Zortrax (ULTRAT), high impact polystyrene (HIPS), polyethylene terephthalate glycol (PETG), polylactic acid (PLA), and a thermoplastic polyester elastomer manufactured by Zortrax (FLEX) were used. We used computed tomography (CT) imaging to determine the HU values of each material, and thus assess its suitability for various applications in radiation oncology. We found that several material and infill density combinations resembled the HU values of fat, soft tissues, and lungs; however, none of the tested materials exhibited HU values similar to that of bone. These results will help researchers and clinicians develop more appropriate instruments for improving the quality of radiation therapy. Using optimized infill densities will help improve the quality of radiation therapy by producing customized instruments for each field of radiation therapy.

Developing a Best-Evidence Pre-employment Medical Examination: An Example from the Construction Industry

  • Gouttebarge, Vincent;van der Molen, Henk F.;Frings-Dresen, Monique H.W.;Sluiter, Judith K.
    • Safety and Health at Work
    • /
    • v.5 no.3
    • /
    • pp.165-167
    • /
    • 2014
  • The Dutch construction industry has introduced a compulsory preemployment medical examination (PE-ME). Best-evidence contents related to specific job demands are, however, lacking and need to be gathered. After the identification of job demands and health problems in the construction industry (systematic literature search and expert meeting), specific job demands and related requirements were defined and instruments proposed. Finally, a work ability assessment was linked to the instruments' outcomes, resulting in the modular character of the developed PE-ME. Twenty-two specific job demands for all Dutch construction jobs were identified, including kneeling/squatting, working under time pressure, and exposure to hazardous substances. The next step was proposing self-report questions, screening questionnaires, clinical tests, and/or performance-based tests, leading to a work ability judgment. "Lifting/carrying" is described as an example. The new modular PE-ME enables a job-specific assessment of work ability to be made for more than 100 jobs in the Dutch construction industry.