• 제목/요약/키워드: Medical Information Standard Technology

검색결과 165건 처리시간 0.034초

A Design of WBAN Data Integration System for the HL7-based patient management

  • Hwang, Chigon;Shin, Hyoyoung;Lee, Jongyong;Jung, Kyedong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제7권1호
    • /
    • pp.66-69
    • /
    • 2015
  • Recently with the development of IT technology, the medical technology have been developed in various ways. Among them, WBAN can check the state of the patient in real time. However, the data generated by these techniques have a problem that they have heterogeneous properties depending on the type of sensors and devices. In this paper, we proposed a method using meta repository as a way to provide the sensing data of WBAN for the health care system by integrating along the HL7 standard item.

비선형 Look-Up Table을 통한 영상 화질 개선에 관한 연구 (Study on image quality improvement using Non-Linear Look-Up Table)

  • 김선칠;이준일
    • 대한디지털의료영상학회논문지
    • /
    • 제5권1호
    • /
    • pp.32-44
    • /
    • 2002
  • The role of radiology department has been greatly increased in the past few years as the technology in the medical imaging devices improved and the introduction of PACS (Picture Archiving and Communications System) to the conventional film-based diagnostic structure is a truly remarkable factor to the medical history. In addition, the value of using digital information in medical imaging is highly expected to grow as the technology over the computer and the network improves. However, the current medical practice, using PACS is somewhat limited compared to the film-based conventional one due to a poor image quality. The image quality is the most important and inevitable factor in the PACS environment and it is one of the most necessary steps to more wide practice of digital imaging. The existing image quality control tools are limited in controlling images produced from the medical modalities, because they cannot display the real image changing status. Thus, the image quality is distorted and the ability to diagnosis becomes hindered compared to the one of the film-based practice. In addition, the workflow of the radiologist greatly increases; as every doctor has to perform his or her own image quality control every time they view images produced from the medical modalities. To resolve these kinds of problems and enhance current medical practice under the PACS environment, we have developed a program to display a better image quality by using the ROI optical density of the existing gray level values. When the LUT is used properly, small detailed regions, which cannot be seen by using the existing image quality controls are easily displayed and thus, greatly improves digital medical practice. The purpose of this study is to provide an easier medical practice to physicians, by applying the technology of converting the H-D curves of the analog film screen to the digital imaging technology and to preset image quality control values to each exposed body part, modality and group of physicians for a better and easier medical practice. We have asked to 5 well known professional physicians to compare image quality of the same set of exam by using the two different methods: existing image quality control and the LUT technology. As the result, the LUT technology was enormously favored over the existing image quality control method. All the physicians have pointed out the far more superiority of the LUT over the existing image quality control method and highly praised its ability to display small detailed regions, which cannot be displayed by existing image quality control tools. Two physicians expressed the necessity of presetting the LUT values for each exposed body part. Overall, the LUT technology yielded a great interest among the physicians and highly praised for its ability to overcome currently embedded problems of PACS. We strongly believe that the LUT technology can enhance the current medical practice and open a new beginning in the future medical imaging.

  • PDF

Evolution of Large-Scale Filmless Full-PACS in Korea

  • Kim, Hee-Joung;Haijo Jung;Yoo, Hyung-Sik
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.28-31
    • /
    • 2002
  • Filmless full-PACS in korea has rapidly been growing, since government had supported collaborative PACS project between industry and university hospital in late of 1995. At the same time, a small company had started PACS business, while the Korea PACS society was being formed. In the beginning, PACS societies had focused on developing peripheral solutions such as DICOM gateway for image acquisition, x-ray film digitizer, and viewing software for research or management of personal image data, while Samsung Medical Center had started installing an imported partial PACS system which had recently upgraded with a new system. In similar time frame, a few hospitals had started developing and installing domestic large scale full-PACS system. Several years later, many hospitals have installed full-PACS system with national policy of reimbursement for PACS exams in November 1999. It is believed that Korea is the first country that adopted PACS reimbursement for filmless full-PACS as a national policy. Both experiences of full-PACS installation and national policy generated tremendous intellectual and technological expertise about PACS at all levels, clinical, hospital management, education, and industrial sectors. There are currently three types of PACS system which includes domestic, imported, and hybrid PACS system with imported solution for core system and domestic solution for peripheral system. There are more than 20 domestic PACS companies and they have now enough experiences so that they are capable of installing a truly full-PACS system for large-scale teaching hospitals. PACS societies in Korea understand how to design, implement, install, manage, sustain, and provide good services for large-scale full-PACS. PACS society has also strength for the highest integration technology of the Hospital Information. However, further understanding and timely implementation of continuously evolving international standard and integrated healthcare enterprise concepts may be necessary for international leading of PACS technologies for the future.

  • PDF

개인정보 보호를 위한 의료영상 발급 표준 업무절차 개발연구 (Development of Standard Process for Private Information Protection of Medical Imaging Issuance)

  • 박범진;유병규;이종석;정재호;손기경;강희두
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권3호
    • /
    • pp.335-341
    • /
    • 2009
  • 목 적 : 기존 필름으로 발급되었던 의료영상은 IT기술의 발달로 디지털화 되어 CD로 발급되고 있다. 그러나 발급 시 신분확인을 하고 있는 의무기록과는 달리 필름을 사용하던 시절부터 의료영상은 별다른 신분확인을 하지 않는 의료기관이 많다. 이에 신청자의 개인의료정보 보호에 대한 인식 실태를 조사하고 여러 의료기관의 CD 또는 DVD 등의 매체를 통한 의료영상 복사 현황을 조사, 정보보안에 관련된 국, 내외 법률 및 권고안을 분석하여 국내 환경에 부합하는 의료영상 복사 발급과 절차를 마련하는 기준을 제시하고자 한다. 대상 및 방법 : 첫째, 2008년 5월 1일부터 7월 31일까지 수도권에 있는 33개 종합병원을 대상으로 의료영상복사 신청 시 구비서류, 발급절차 등을 전화를 통한 유선 조사를 시행하였다. 신청자에 따른 구비서류를 의료법 제 21조 2항에 의거 (1) 본인일 경우 신분증 확인, (2) 가족일 경우 신청자 신분증, 가족관계 서류(건강보험증, 가족관계증명서, 등본 등), (3) 제 3자 대리인일 경우 신분증, 위임장, 인감증명서로 기준을 마련하여 조사하였다. 둘째, 연구기간 동안 위의 기준에 따라 의료영상을 발급해 주고 있는 K 의료원에 복사를 신청하는 신청자들이 준비해온 구비서류 여부를 파악하였다. 셋째, 구비서류의 확인 및 미비 시 조치 등에 대한 발급절차의 기준을 정립하여 프로세스를 개발하였다. 결 과 : 수도권 33개 의료영상 발급현황을 조사한 결과 모든 조건을 충족한 병원은 16곳(49%), 신분증만 있으면 가능한 병원은 4곳(12%), 누구나 신청 가능한 병원 4곳(12%)이었으며 의료영상을 발급하는 부서가 아닌 진료과에서 신청하는 곳이 9곳(27%)으로 구비서류 조건여부는 알 수 없었다. 또한 신청자들이 복사 신청시 준비해온 구비서류가 조건에 충족한지 3개월간의 조사 결과 모두 준비한 경우(완비)는 629건(49%), 일부만 준비한 경우(일부 미비) 416건(33%), 모두 준비하지 않은 경우(미비) 226건(18%)이였다. 위의 연구결과를 근거로 의료영상 복사 신청 절차에 대한 프로세스를 정립하여 객관적인 응대를 할 수 있도록 하고, 환자와의 마찰을 줄이고 불편을 최소화 하면서 환자의 편의를 도모하고자 세분화된 발급절차 모형도를 작성하였다. 결 론 : 다른 전산 시스템과 달리 의료영상 시스템인 PACS가 의료기기로 분류되어 있는 것은 그만큼 의료정보의 중요성이 크다는 의미이다. 또한 의료영상의 학문적 성격으로 의학교육 및 연구에 많이 쓰이는데 이러한 이유로 쉽게 인용되고 남용 될 수 있다. 따라서 의료영상은 전문적인 교육을 받은 의료영상 관리자에 의해 적절한 발급 기준으로 발급, 관리되어야 할 것이며 이에 관한 개인정보보호와 의료영상에 대한 적극적인 홍보가 필요할 것이다.

  • PDF

International Standard for the Banking, Brokerage and Insurance Industries

  • Jung, Yong Gyu;Seo, Weon Joon;Jung, Ga-Woon;Choi, Byeong Cheol;Dollein, Richard
    • International Journal of Advanced Culture Technology
    • /
    • 제2권1호
    • /
    • pp.20-24
    • /
    • 2014
  • As the standards organization under ISO responsible for the development of all international financial services standards, ISO/TC 68 plays a key role in the development and adoption of new technologies in the banking, brokerage and insurance industries. In this paper many of its current work projects are introduced for developing ecommerce standards. We need to discuss the recommendations on XML conversion with ISO and other international standard organizations. Each country try to adopt the international standards even though domestic technical standards and barriers. To solve this problem of interworking between these standards, harmonization activities are nedded. For development and distribution of electronic documents to be conformed to international standards, it is enough to have the role of international activities continue to supply part of the domestic industry and the trends in participation and international standard.Our principal focus is on facilitating national and international trade, through the simplification and harmonization of processes, procedures and information flows, and so contributing to the growth of global commerce.

A study on Measurement and Improvement of Indoor Air Quality in Dental Clinic

  • Choi, Mi-Suk;Ji, Dong-Ha
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권11호
    • /
    • pp.143-149
    • /
    • 2018
  • The purpose of this study is to propose a management method to maintain the pleasant indoor air quality of the dental clinic by measuring and analyzing the indoor air quality of the dental clinic. The measurement was conducted in two rooms, a lobby where many residents stay in the reception room for waiting for medical treatment, and a VIP room where treatment activities are mainly performed. Measurement items are Temperature, Humidity, $CO_2$, CO, $NO_2$, $CH_2O$, VOC, $PM_{10}$ and measurement were taken on April 27, 2018. As a result of analyzing the temperature and humidity of the dental clinic, it was analyzed that the average indoor temperature was maintained at $25^{\circ}C$ and the humidity was kept at around 50%, maintaining proper indoor temperature and humidity environment. $CO_2$ was 855ppm in the VIP Room, which satisfied the maintenance standard. In the case of the lobby, it was analyzed to be 1,160ppm, which exceeded the maintenance standard and it is judged that the carbon dioxide generated by the respiration of the people staying in the lobby is the main reason. The mean concentration of formaldehyde in the VIP room was analyzed as $436{\mu}g/m^3$, exceeding the maintenance standard, and $2,100{\mu}g/m^3$ for the VOC exceeded the recommended standard. It was analyzed that the concentration was relatively higher due to the use of disinfectant and other drugs. The mean concentration of PM-10 in the lobby was analyzed as $65{\mu}g/m^3$ and it was analyzed that it satisfied the maintenance standard. To maintain a pleasant indoor air quality in a dental clinic it is necessary to minimize the effects of formaldehyde, VOC, $CO_2$ in the VIP rooms and lobby. For this purpose, the entire ventilation system and air purification system of the dental clinic should be installed. In case of the VIP room, local exhaust ventilation should be installed and workers should wear personal protective equipment.

Enhancing the Image Transmission over Wireless Networks through a Novel Interleaver

  • El-Bendary, Mohsen A.M.;Abou-El-Azm, A.E.;El-Fishawy, N.A.;Shawki, F.;El-Tokhy, M.;Abd El-Samie, F.E.;Kazemian, H.B.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제5권9호
    • /
    • pp.1528-1543
    • /
    • 2011
  • With increasing the using of wireless technologies in essential fields such as the medical application, this paper proposes different scenarios for the transmission of images over wireless networks. The paper uses the IEEE ZigBee 802.15.4 for applying the proposed schemes. It is a Wireless Personal Area Network (WPAN). This paper presents a novel chaotic interleaving scheme against error bursts. Also, the paper studies the proposed interleaver with the convolutional code with different constraint lengths (K). A comparison study between the standard scheme and proposed schemes for image transmission over a correlated fading channel is presented. The simulation results show the superiority of the proposed chaotic interleaving scheme over the traditional schemes. Also, the chaotic interleaver packet-by-packet basis gives a high quality image with (K=3) and reduces the need for the complex encoder with K=7.

유전상담의 제도적인 고찰 (Genetic counseling in Korean health care system)

  • 김현주
    • Journal of Genetic Medicine
    • /
    • 제4권1호
    • /
    • pp.1-5
    • /
    • 2007
  • Unprecedented amount of genetic information being generated from the result of Human Genome Project (HGP) and advances in genetic research is already forcing changes in the paradigm of health and disease. The ultimate goal of genetic medicine is to use genetic information and technology to develop new ways of treatment or even prevention of the disease on an individual level for 'personalized medicine'. Genetics is play ing an increasingly important role in the diagnosis, monitoring and management of common multifactorial diseases in addition to rare single-gene disorders. While wide range of genetic testing have provided benefits to patients and family, uncertainties surrounding test interpretation, the current lack of available medical options for the diseases, and risks for discrimination and social stigmatization may remain to be resolved. However an increasing number of genetic tests are becoming commercially available, including direct to consumer genetic testing, yet public is often unaw are of their clinical and social implications. The personal nature of information generated by a genetic test, its power to affect major life decisions and family members, and its potential misuse raise important ethical considerations. Therefore appropriate genetic counseling is needed for patient to be informed with the benefits, limitations and risks of genetic tests, prior to informed consent for the tests. Physician also should be familiar with the legal and ethical issues involved in genetic testing to tell patients how w ell a particular genetic risk factor relates with likelihood of disease, and be able to provide appropriate genetic counseling. Genetic counseling become a mandatory requirement as global standard for many genetic testing such as prenatal diagnosis, presymtomatic DNA diagnostic tests and cancer susceptibility gene test for familial cancer syndrome. In oder to meet the challenge of genetic medicine of 21 century in korean health care system, professional education program and certification board for medical genetics specialist including non-MD genetic counselors should be addressed by medical society and regulatory policy of national health insurance reimbursement for genetic counseling to be in place to promote the implementation of clinical genetic service including genetic counseling for proper genetic testing.

  • PDF

Rapid Detection of Streptococcus mutans Using an Integrated Microfluidic System with Loop-Mediated Isothermal Amplification

  • Jingfu Wang;Jingyi Wang;Xin Chang;Jin Shang;Yuehui Wang;Qin Ma;Liangliang Shen
    • Journal of Microbiology and Biotechnology
    • /
    • 제33권8호
    • /
    • pp.1101-1110
    • /
    • 2023
  • Streptococcus mutans is the primary causative agent of caries, which is one of the most common human diseases. Thus, rapid and early detection of cariogenic bacteria is critical for its prevention. This study investigated the combination of loop-mediated isothermal amplification (LAMP) and microfluid technology to quantitatively detect S. mutans. A low-cost, rapid microfluidic chip using LAMP technology was developed to amplify and detect bacteria at 2.2-2.2 × 106 colony-forming units (CFU)/ml and its detection limits were compared to those of standard polymerase chain reaction. A visualization system was established to quantitatively determine the experimental results, and a functional relationship between the bacterial concentration and quantitative results was established. The detection limit of S. mutans using this microfluidic chip was 2.2 CFU/ml, which was lower than that of the standard approach. After quantification, the experimental results showed a good linear relationship with the concentration of S. mutans, thereby confirming the effectiveness and accuracy of the custom-made integrated LAMP microfluidic system for the detection of S. mutans. The microfluidic system described herein may represent a promising simple detection method for the specific and rapid testing of individuals at risk of caries.

A Three-Dimensional Deep Convolutional Neural Network for Automatic Segmentation and Diameter Measurement of Type B Aortic Dissection

  • Yitong Yu;Yang Gao;Jianyong Wei;Fangzhou Liao;Qianjiang Xiao;Jie Zhang;Weihua Yin;Bin Lu
    • Korean Journal of Radiology
    • /
    • 제22권2호
    • /
    • pp.168-178
    • /
    • 2021
  • Objective: To provide an automatic method for segmentation and diameter measurement of type B aortic dissection (TBAD). Materials and Methods: Aortic computed tomography angiographic images from 139 patients with TBAD were consecutively collected. We implemented a deep learning method based on a three-dimensional (3D) deep convolutional neural (CNN) network, which realizes automatic segmentation and measurement of the entire aorta (EA), true lumen (TL), and false lumen (FL). The accuracy, stability, and measurement time were compared between deep learning and manual methods. The intra- and inter-observer reproducibility of the manual method was also evaluated. Results: The mean dice coefficient scores were 0.958, 0.961, and 0.932 for EA, TL, and FL, respectively. There was a linear relationship between the reference standard and measurement by the manual and deep learning method (r = 0.964 and 0.991, respectively). The average measurement error of the deep learning method was less than that of the manual method (EA, 1.64% vs. 4.13%; TL, 2.46% vs. 11.67%; FL, 2.50% vs. 8.02%). Bland-Altman plots revealed that the deviations of the diameters between the deep learning method and the reference standard were -0.042 mm (-3.412 to 3.330 mm), -0.376 mm (-3.328 to 2.577 mm), and 0.026 mm (-3.040 to 3.092 mm) for EA, TL, and FL, respectively. For the manual method, the corresponding deviations were -0.166 mm (-1.419 to 1.086 mm), -0.050 mm (-0.970 to 1.070 mm), and -0.085 mm (-1.010 to 0.084 mm). Intra- and inter-observer differences were found in measurements with the manual method, but not with the deep learning method. The measurement time with the deep learning method was markedly shorter than with the manual method (21.7 ± 1.1 vs. 82.5 ± 16.1 minutes, p < 0.001). Conclusion: The performance of efficient segmentation and diameter measurement of TBADs based on the 3D deep CNN was both accurate and stable. This method is promising for evaluating aortic morphology automatically and alleviating the workload of radiologists in the near future.