• Title/Summary/Keyword: Medical Information Applications

Search Result 468, Processing Time 0.033 seconds

Perception and Use of Web 2.0 Applications by Medical Students of Ambrose Alli University Ekpoma

  • Ikenwe, Iguehi Joy;Idhalama, Ogagaoghene Uzezi;Ode, Christian Edokpolo
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.9 no.2
    • /
    • pp.45-64
    • /
    • 2019
  • This study examined the perception and use of web 2.0 applications for academic purposes by medical students of Ambrose Alli University, Ekpoma. The objective was to investigate the medical students' perceptions of web 2.0 applications, web 2.0 tools use, extent of use, perception and purpose for using web 2.0 applications. Descriptive survey method was used for this study. The total population of this study was 3670 and the sample size was 367 representing 10% of the study. The purposive sampling technique was adopted, and the instrument used for this study was questionnaire, a total of 367 copies were administered and 321 were found useful for the study. Percentage means and standard deviation on table and chart were used to analyze the data collected using Statistical Package for the Social Sciences (SPSS) software. Findings showed that the perception of web 2.0 applications of medical students AAU was positive and few of web 2.0 applications were used for academic purposes. It was recommended in the study that medical students should be provided with the facilities in a format more familiar to them and used by most of them and institutions need to equip the learning process with the needed facilities which will be of utmost benefit even for future purposes.

Accuracy and reliability evaluation of basic CPR application information developed in Korean (국문으로 개발된 기본심폐소생술 애플리케이션 정보의 정확성과 신뢰성 평가)

  • Jung, Eun-Kyung;Kang, Ji-Hun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.23 no.3
    • /
    • pp.41-51
    • /
    • 2019
  • Purpose: This dissertation is a descriptive research study analyzing the accuracy and reliability of the cardiopulmonary resuscitation (CPR) application developed in Korea. Methods: Two faculty members from the emergency medical services department and the emergency medicine department searched applications from July 1 to July 10, 2019 and selected a total of 13 applications. Twelve questions were assessed for information accuracy and three were assessed for reliability. In accordance with application types, the number and mean ± standard deviation were analyzed. The t-test was used to compare the accuracy of CPR information in accordance with information sources. Results: The results revealed the following errors: 7 cases (53.8%) identified the chest center lining from the nipple center-line as the chest pressure point; 5 cases (38.5%) did not provide information on the depth of 6 cm that should not be exceeded; and 4 cases (30.8%) did not provide advise to check respiration. When the CPR information sources were included, the information accuracy score was high; a significant difference was observed (p=.035). Conclusion: In the case of applications providing medical information regarding CPR, it is necessary to provide at least authoritarian, sources of information, and author transparency as well as continuous effort and attention.

Image Registration in Medical Applications

  • Hong, Helen
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.2
    • /
    • pp.62-66
    • /
    • 2014
  • Image registration is the process for finding the correct geometrical transformation that brings one image in precise spatial correspondence with another image. There are limitations on the visualization of simple overlay between two different modality images because two different modality images have different anatomical information, resolution, and viewpoint. In this paper, various image registration methods and their applications are introduced. With the recent advance of medical imaging device, image registration is used actively in diagnosis support, treatment planning, surgery guidance and monitoring the disease progression.

A comparative study of medical image applications: compression and transmission

  • Cho, Kyu-Cheol;Kim, Jae-Joon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.12 no.5
    • /
    • pp.14-22
    • /
    • 2007
  • PACS is an integrated communication network system which is consists of image acquisition devices, storage archiving units, display stations, computer processors, and database management systems. In medical industry, they have been introduced the medical equipments through PACS systems based on the DICOM standard. In this paper, we have reviewed the visual quality performance of various JPEG and JPEG2000 compression options for medical images. Through the realized the transmission mode on DICOM standard, the developed DICOM viewer has been shown in medical applications.

  • PDF

On Realization Medical Imaging Viewer based on DICOM Standard

  • Cho, Kyu-Cheol;Kim, Jae-Joon
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2005.11a
    • /
    • pp.157-160
    • /
    • 2005
  • PACS is an integrated communication network system which is consists of image acquisition devices, storage archiving units, display stations, computer processors, and database management systems. In medical industry, they have been introduced the medical equipments through PACS systems based on the DICOM standard. In this paper, we have reviewed the performance of JPEG and JPEG2000 used as medical image compression and realized the transmission mode on DICOM standard.

  • PDF

A study on continuous use intention of medical information service applications: Application of the Extended Theory of Planned Behavior

  • Seok Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.2
    • /
    • pp.153-168
    • /
    • 2024
  • The purpose of this study was to verify the correlation between variables that affect the intention to continue using medical information service applications. Then, we established a research model based on ETPB and conducted an empirical study using PLS-SEM.According to the empirical analysis results, First, intimacy, prior knowledge, and cost saving were confirmed to have a significant impact on the TPB variables such as attitude, subjective norm, and perceived behavioral control. Second, it was confirmed that TPB variables had a significant impact on behavioral intention, and behavioral intention had a significant impact on continued use intention. Third, it was confirmed that familiarity, prior knowledge, and cost saving had a significant impact on the intention to continue use through the mediation of behavioral intention based on the perception shift of medical consumers. The significance of this study is that it empirically investigated the behavior of medical consumers by deriving the impact on their intention to continue using medical information service applications through their behavioral intentions.

A Secure Medical Information Management System for Wireless Body Area Networks

  • Liu, Xiyao;Zhu, Yuesheng;Ge, Yu;Wu, Dajun;Zou, Beiji
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.1
    • /
    • pp.221-237
    • /
    • 2016
  • The wireless body area networks (WBANs) consist of wearable computing devices and can support various healthcare-related applications. There exist two crucial issues when WBANs are utilized for healthcare applications. One is the protection of the sensitive biometric data transmitted over the insecure wireless channels. The other is the design of effective medical management mechanisms. In this paper, a secure medical information management system is proposed and implemented on a TinyOS-based WBAN test bed to simultaneously address these two issues. In this system, the electronic medical record (EMR) is bound to the biometric data with a novel fragile zero-watermarking scheme based on the modified visual secret sharing (MVSS). In this manner, the EMR can be utilized not only for medical management but also for data integrity checking. Additionally, both the biometric data and the EMR are encrypted, and the EMR is further protected by the MVSS. Our analysis and experimental results demonstrate that the proposed system not only protects the confidentialities of both the biometric data and the EMR but also offers reliable patient information authentication, explicit healthcare operation verification and undeniable doctor liability identification for WBANs.

A study on the User's Satisfaction and Intention to Re-use the U-Healthcare Services: Focusing on the User's Response of Personalized Medical Information Applications (유헬스케어 서비스 사용자의 만족도와 재사용의도 영향 요인에 대한 연구: 개인용 의료정보 애플리케이션 사용자의 반응을 중심으로)

  • Park, Ji Min;Jo, Eun Hee;Lee, Jong Tae
    • The Journal of Information Systems
    • /
    • v.29 no.2
    • /
    • pp.243-263
    • /
    • 2020
  • Purpose The purpose of this study is to analyze the causal relationship between user satisfaction, expected satisfaction, quality of service, perceived value, and expertise that should be emphasized in personalized medical information services for the development of personalized medical information services based on big data analysis and the spread of their demand. Design/methodology/approach This study established research models and hypotheses on the basis of the theory of reuse intent, and applied the PLS methodology for analysis, the factors that make it applicable to personalized medical services in the theory of service quality and satisfaction. Findings According to the empirical analysis result, this study confirmed that it can be seen that the expertise, perceived value, and quality of medical services did not directly affect the user's intention to reuse, but formed a direct causal relationship through variables such as whether they met expectations.

Wireless LAN with Medical-Grade QoS for E-Healthcare

  • Lee, Hyung-Ho;Park, Kyung-Joon;Ko, Young-Bae;Choi, Chong-Ho
    • Journal of Communications and Networks
    • /
    • v.13 no.2
    • /
    • pp.149-159
    • /
    • 2011
  • In this paper, we study the problem of how to design a medical-grade wireless local area network (WLAN) for healthcare facilities. First, unlike the IEEE 802.11e MAC, which categorizes traffic primarily by their delay constraints, we prioritize medical applications according to their medical urgency. Second, we propose a mechanism that can guarantee absolute priority to each traffic category, which is critical for medical-grade quality of service (QoS), while the conventional 802.11e MAC only provides relative priority to each traffic category. Based on absolute priority, we focus on the performance of real-time patient monitoring applications, and derive the optimal contention window size that can significantly improve the throughput performance. Finally, for proper performance evaluation from a medical viewpoint, we introduce the weighted diagnostic distortion (WDD) as a medical QoS metric to effectively measure the medical diagnosability by extracting the main diagnostic features of medical signal. Our simulation result shows that the proposed mechanism, together with medical categorization using absolute priority, can significantly improve the medical-grade QoS performance over the conventional IEEE 802.11e MAC.