• Title/Summary/Keyword: Medical Image

Search Result 3,584, Processing Time 0.036 seconds

Mediating effect of trust in relationships between perceived quality of the medical service and hospital image and revisit intent (지각된 의료서비스 품질과 병원이미지 및 재방문의도 관계에서 신뢰의 조절효과)

  • Choi, Chul-Jae;Cho, Hyoung-Rae
    • Korea Journal of Hospital Management
    • /
    • v.20 no.2
    • /
    • pp.57-71
    • /
    • 2015
  • In this research, by confirming the path relation between the patient's perceived quality of the medical service and their revisit intent, and by investigating the adjustment effect of the customer's trust of the hospital between the quality of the medical service and the image of the hospital and the revisit intent, this research has the objective of presenting basic data and documentation for the establishment of both a positive hospital image to medical care customers and also a differentiated medical service marketing strategy. The deduced results of the research are as follows. First, the quality of medical service was shown to have a significant influence on the image of the hospital, and second, the quality of medical service was shown to have a significant influence on the revisit intent, but only on certain dimensions. Third, it could be confirmed that there was a partial adjustment effect on the customer's trust of the hospital from the relationship between the revisit intent and the image of the hospital and its quality of the medical service. Finally, it was confirmed that the image of a hospital had a very significant influence on the revisit intent.

Medical Image Retrieval with Relevance Feedback via Pairwise Constraint Propagation

  • Wu, Menglin;Chen, Qiang;Sun, Quansen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.1
    • /
    • pp.249-268
    • /
    • 2014
  • Relevance feedback is an effective tool to bridge the gap between superficial image contents and medically-relevant sense in content-based medical image retrieval. In this paper, we propose an interactive medical image search framework based on pairwise constraint propagation. The basic idea is to obtain pairwise constraints from user feedback and propagate them to the entire image set to reconstruct the similarity matrix, and then rank medical images on this new manifold. In contrast to most of the algorithms that only concern manifold structure, the proposed method integrates pairwise constraint information in a feedback procedure and resolves the small sample size and the asymmetrical training typically in relevance feedback. We also introduce a long-term feedback strategy for our retrieval tasks. Experiments on two medical image datasets indicate the proposed approach can significantly improve the performance of medical image retrieval. The experiments also indicate that the proposed approach outperforms previous relevance feedback models.

Design and Implementation of the Endoscope Image Store System in the Orthopedics (정형외과 관절경 영상 저장 시스템의 설계 및 구현)

  • 심갑식;정태영
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.4
    • /
    • pp.8-15
    • /
    • 2002
  • This Paper proposes designing and implementing the database system storing the medical images. This system collects the medical image when doctors operate and diagnose the patients using the endoscope in the orthopedics, then stores the medical image data to database. Therefore. system avoids duplicated medical data, retrieves and updates the medical data effectively. The medical image data can be shared to the multiple users and application programs. This system consists of the five components. that is, the input module acquiring the medical image from the endoscope. the modulo storing the medical image. the database design and implementation storms the patient's disease history and the medical image data, user friendly interface design and implementation, and the simple data retrieval engine. The features of the system are followed. The image catcher program using DirectShow is portable any image catcher board And because the image catcher algorithm is implemented as a public module, The throughput can be increased during the development of video and audio contents on internet.

  • PDF

Comparison of paramedic image and its determinants between paramedic and non-paramedic students (응급구조학과 학생과 타 학과 학생이 지각한 응급구조사 이미지와 이미지 결정요인)

  • Park, Jeong-Mi;Kim, Su-Min
    • The Korean Journal of Emergency Medical Services
    • /
    • v.19 no.2
    • /
    • pp.39-49
    • /
    • 2015
  • Purpose: The purpose of the study was to identify differences in paramedic image and its determinants between paramedic and non-paramedic students. Methods: From September 18 to 26, 2013, data were collected from 146 universities students by using a self-reported questionnaire. Results: The mean paramedic image score was 4.22 for paramedic students and 3.89 for non-paramedic students. The paramedic students had a more positive paramedic image than the non-paramedic students. Among three subcategories of paramedic image, professional image was selected as the most positive factor. The determinants of paramedic image differed between the paramedic and non-paramedic students. The mean subjective determinants score showed higher than those of any other determinants for both student groups. Conclusion: The findings of this study showed that practical strategies are needed to promote a positive paramedic image among non-paramedic students.

A Study on Virtual Reality Management of 3D Image Information using High-Speed Information Network (초고속 정보통신망을 통한 3차원 영상 정보의 가상현실 관리에 관한 연구)

  • Kim, Jin-Ho;Kim, Jee-In;Chang, Chun-Hyon;Song, Sang-Hoon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.12
    • /
    • pp.3275-3284
    • /
    • 1998
  • In this paper, we deseribe a Medical Image Information System. Our system stores and manages 5 dimensional medical image data and provides the 3 dimensional medical data via the Internet. The Internet standard VR format. VRML(Virtual Reality Modeling Language) is used to represent the 3I) medical image data. The 3D images are reconstructed from medical image data which are enerated by medical imaging systems such ans CT(Computerized Tomography). MRI(Magnetic Resonance Imaging). PET(Positron Emission Tomograph), SPECT(Single Photon Emission Compated Tomography). We implemented the medical image information system shich rses a surface-based rendering method for the econstruction of 3D images from 2D medical image data. In order to reduce the size of image files to be transfered via the Internet. The system can reduce more than 50% for the triangles which represent the surfaces of the generated 3D medical images. When we compress the 3D image file, the size of the file can be redued more than 80%. The users can promptly retrieve 3D medical image data through the Internet and view the 3D medical images without a graphical acceleration card, because the images are represented in VRML. The image data are generated by various types of medical imaging systems such as CT, MRI, PET, and SPECT. Our system can display those different types of medical images in the 2D and the 3D formats. The patient information and the diagnostic information are also provided by the system. The system can be used to implement the "Tele medicaine" systems.

  • PDF

Extended JPEG Progressive Coding for Medical Image Archiving and Communication (확장 JPEG 표준을 이용한 점진식 의료 영상 압축)

  • Ahn, Chang-Beom;Han, Sang-Woo;Kim, Il-Yeon
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.2
    • /
    • pp.175-182
    • /
    • 1994
  • The international standard for digital compression and coding of continuous-tone still image known as JPEG (Joint Photographic Experts Group) standard is investigated for medical image archiving and communication. The JPEG standard has widely been accepted in the areas of electronic image communication, computer graphics, and multimedia applications, however, due to the lossy character of the JPEG compression its application to the field of medical imaging has been limited. In this paper, the JPEG standard is investigated for medical image compression with a series of head sections of magnetic resonance (MR) images (256 and 4096 graylevels, $256 {\times}256$size). Two types of Huffman codes are employed, i. e., one is optimized to the image statistics to be encoded and the other is a predetermined code, and their coding efficiencies are examined. From experiments, compression ratios of higher than 15 were obtained for the MR images without noticeable distortion. Error signal in the reconstructed images by the JPEG standard appears close to random noise. Compared to existing full-frame bit-allocation technique used for radiological image compression, the JPEG standard achieves higher compression with less Gibb's artifact. Feature of the progressive image build-up of the JPEG progressive coding may be useful in remote diognosis when data is transmitted through slow public communication channel.

  • PDF

Medical Image Workstation Using Multimedia Technique (멀티미디어를 이용한 의료용 영상 워크스테이션)

  • 이태수;차은종
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.1
    • /
    • pp.63-70
    • /
    • 1994
  • A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors'reporting results. Input int'ormation was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and Analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed id'ormation can be transferred for patient diagnosis through LAN (local area network).

  • PDF

A Study on the Development of PC-card for Information Transmission of Medical Image in the Environment of ISDN(Intergrated Service Digital Network) (종합정보통신망 환경속에서 의료 영상정보 전달을 위한 PC-card 개발에 관한 연구)

  • 이동화;임춘성
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.243-248
    • /
    • 1991
  • This paper described the implementation of high speed transmission fort medical image between hospitals using ISDN. The implemented system, called PC-card, can transmit datas as 144Kbps and can install in the personal computer. So, this enables to get more reliable medical image with less cost, and to service the better quality for an unurbanized area. In this system, installing in the PC system were enhanced to input from medical image system and output to the memory or display

  • PDF

Performance Evaluation of Medical Image Transmission System using TH UWB-IR Technology

  • Lee, Yang-Sun;Kang, Heau-Jo
    • Journal of information and communication convergence engineering
    • /
    • v.4 no.3
    • /
    • pp.97-100
    • /
    • 2006
  • In this paper, the transmission service for medical image is proposed via IEEE 802.15.4a on WPAN environment. Also, transmission and receiving performance of medical image using TH UWB-IR system is evaluated on indoor multi-path fading environment. On the results, the proposed scheme can solve the problem of interference from the medical equipment in same frequency band, and minimize the loss due to the indoor multi-path fading environment. Therefore, the transmission with low power usage is possible.