• Title/Summary/Keyword: Medical Examination Result

Search Result 648, Processing Time 0.04 seconds

The Analysis on Related Factors of the Aged Examines Who Get Diagnosed in Their Climacteric Period According to Sex (생애전환기 건강진단 노인수검자의 성별에 따른 관련 요인분석)

  • Keum, Eun-Sun;Seo, Bu-Il
    • Korean Journal of Oriental Medicine
    • /
    • v.16 no.1
    • /
    • pp.119-134
    • /
    • 2010
  • Objectives & Method:Based on the statistic from January 2008 to December 2008 include 66-year-old 375 people (159 men, 216 women) who got examined in National Health Insurance Corporation, this study set a goal to establish a new health index by analyzing the relation between the cardio-cerebra vascular disease and risk factor such as obesity, smoking, exercise, alcohol consumption, blood pressure, blood sugar and cholesterol. Results:1) Examine results, health status according to gender;People who are diagnosed as abnormal health status have higher risk for both men and women. As for the detailed diseases, high blood pressure was highest followed by hyperlipidemia and obesity. In case of the women, 96.3% in bone mineral density was highest. 2) Correlation of disease and health risk factors based on gender;Correlation of disease according to gender in the obesity(p<0.001), lipid abnormalities(p<0.001), kidney diseases(p<0.001), chest diseases(p<0.05), osteoporosis(p<0.001) showed a statistically significant difference. The analysis showed that the men have more obesity and lipid abnormalities as well as thoracic disease than the women, but the women have more kidney disease than the men. As for the osteoporosis examine which is conducted only for the women, most of the women were abnormal even though it cannot compare the result according to gender. Obesity(p<0.001), alcohol(p<0.001), smoking(p<0.001) and LDLcholesterol(p<0.001) showed statistical correlation between gender and health risk factor. And only high blood pressure(p<0.001) showed a statistical correlation between gender and risk of cardio-cerebra vascular disease. 3) Risk of cardio-cerebra vascular disease related to health risk factor characteristic;Obesity assessment(p<0.001), alcohol(p<0.05), smoking(p<0.05), blood pressure(p<0.001), glucose(p<0.001) showed correlation between health risk factor and stroke. Drinking(p<0.001), smoking(p<0.05), exercise(p<0.001), blood pressure(p<0.001), LDL cholesterol(p<0.001) showed health risk factor and myocardial infarction. Obesity assessment(p<0.001), smoking(p<0.05), blood pressure(p<0.001), glucose(p<0.001) and showed correlation between health risk factor and diabetes. Obesity assessment(p<0.001), blood pressure(p<0.001) showed correlation between health risk factor and high blood pressure. Conclusion:Therefore, we have to take one step farther after the health examination. In order to prevent and reduce the risk of disease, people have to understand their health status exactly first, and correct their habit with recognizing the amount of risk related to cardio-cerebra vascular disease.

A feasibility study on new stimulation method in fMRI language examinations using custom designed images (기능적 자기공명영상의 언어기능검사 시 image를 이용한 자극방법의 타당성 연구)

  • Choi, Kwan-Woo;Son, Soon-Yong;Jeong, Mi-Ae;Min, Jung-Whan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5005-5011
    • /
    • 2011
  • The purpose of this work is to know the validity of a new stimulation method in cognitive functional imaging using custom-designed images correspond to words or syllables improving the shortcomings of existing method using text. From March 2011 to May five Subjects in need of language related functional MRI scanning were selected and both of text stimulating method and image stimulating method sacanning were carried out three times each. Using 3.0T Philps MRI machine and Invivo Co's Eloquence system, data acquisition was performed with EPI-BOLD technique. Post processing was performed with SPM 99 while the activated signals were determined within 95 percent confidence level.The number of activation clusters and the activation ratio inside ROI were compared. As as result, all of the subject showed activation inside Broca area but it did not have statistical significance. In conclusion, the image sitimulation method has potential because image itself is a common means of recognition and it can be recognised easily even if there language barrier. This stimulation method can be applied to replacing the exising scanning method especially in the elderly, infants, foerigners who may not fully understand about the examination.

Usability Evaluation of Gel Pad Materials for Superficial Structures used in Musculoskeletal Ultrasonography (근골격계 초음파검사에 사용되는 표재성 검사용 젤 패드 물질의 유용성 평가)

  • Han, Mi-Ran;Kwak, Jong-Gil;Song, Jong-Nam;Jang, Seong-Ju;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.899-909
    • /
    • 2021
  • In Musculoskeletal ultrasound examination, a linear transducer (12-5 MHz) with a contact surface length of 6 cm, which is commonly distributed in medical institutions, does not contact with bent fingers and wrist depressions only by using a conventional liquid ultrasound gel, which causes image loss. In order to solve this image loss, the use of commercially available Water gel pad is increasing. However, it is a disposable medical product. Repeated use is prohibited and expensive. In this study, in order to reduce the economic burden caused by the use of the commercialized Water gel Pad, we searched for water-soluble food thickener powder that can be easily purchased around our lives and manufactured Gel pads. Among them, kappa-Carrageenan Gel Pad, iota-Carrageenan Gel Pad, and Agar-Agar Gel Pad satisfied the evaluation criteria without artifacts in image evaluation using the N-365 Multipurpose Phantom. Also, the price to purchase the food thickener powder was about 38 times cheaper than the existing commercialized Water gel pad. As a result, if you use the food thickener powder such as kappa-Carrageenan, iota-Carrageenan and Agar-Agar to make solidified elastic Gel pad without a cover instead of the commercially available expensive disposable Water gel pad, the convenience and usefulness of use are improved. It is judged that the manufactured Gel pads can contribute well to the role of efficient ultrasound propagation medium.

Comparison of the Cognitive Function and Nutrient Intakes of Elderly Women with Dementia in a Long-Term Care Facility and a Day-Time Care Facility in Incheon (인천지역 장기요양시설과 주간보호시설 여성치매노인의 인지기능 및 영양섭취 비교)

  • Bae, Mi Ae;Lee, Young Whee;Kim, Hwa Soon;You, Jeong Soon;Chang, Kyung Ja
    • Journal of the Korean Society of Food Culture
    • /
    • v.34 no.4
    • /
    • pp.389-400
    • /
    • 2019
  • In this study we compared the cognitive function (Mini-Mental State Examination for Dementia Screening: MMSE-DS) and nutrient intake of elderly women with dementia in a long-term care facility (EW-LCF) and a day-time care facility (EW-DCF). This survey was conducted from July 2015 to May 2017 on 73 elderly women with dementia (47 women in LCF and 26 women in DCF) in the city of Incheon. The data obtained from interviews with the subjects and caregivers were analyzed using the SPSS 20.0. The total score of the MMSE-DS and intakes of most nutrients in the EW-LCF were significantly lower compared to the EW-DCF (p<0.05). The nutrient adequacy ratios (NAR) of protein, vitamin A, C, $B_6$, $B_{12}$, thiamin, riboflavin, niacin, folic acid, calcium and phosphorus in the EW-LCF were significantly lower compared to the EW-DCF (p<0.05). However, the indexes of nutritional quality (INQ) of vitamin C, $B_6$, thiamine, niacin, calcium, magnesium, and iron in the EW-LCF were significantly higher compared to the EW-DCF (p<0.05). As a result, the subjects showed an unbalanced and insufficient nutrition intake status regardless of the type of care facility. Most nutrient intakes of the EW-LCF with lower cognitive function were very significantly lower compared to the EW-DCF (p<0.001). Therefore, it is necessary to assess the cognitive function and nutritional status regularly at care facilities for the elderly women suffering with dementia and to provide specialized individual nutritional management.

Evaluation of Scattered Rays of Jelly Type Shielding Body by L-spine AP using X-ray (L-Spine X-선 촬영에서의 Jelly type 차폐체의 산란선 차폐평가)

  • Jang, Hui-Min;Kim, Do-Gwon;Kim, Hyeong-Bin;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.907-913
    • /
    • 2020
  • There have been continuous controversies on medical X-ray protection and numerous researchers have been trying to prevent unnecessary exposure to radiation. As X-ray passes through the patient and obtains an image, it creates scattered ray due to interactions such as photoelectric effect and Compton scattering with the subject. As a result, both medical radiation staff and patient are exposed to unnecessary radiation on areas other than the target area. In response, this study will be assuming a body of a female, radiating X-ray on the phantom under the conditions of lumbar spine AP test, and measuring scattered ray around breasts and thyroid glands. Then, The experiment results were as follows. After application of non-shielding material, the average of scattered ray was 0.88 mR in thyroid measurement, 3.34 mR, Lt Axillary 3.54 mR, and Rt Axillary 3.03 mR in mamonary measurement but, After application of shielding material, the average of scattered ray was 0.16 mR in thyroid measurement, 0.60 mR, Lt Axillary 0.64 mR, and Rt Axillary 0.54 mR in mamonary measurement showing average scattered ray protection effect of about 82%. This study suggested the manufacturing method of a Jelly-type shielding material, identified the possibilities of researches on mixing various substances with radiology field, and verified the usability of the Jelly-type shielding material as a substitute for existing protection tools.

Study of Spectral Doppler Waveform Interpretation and Nomenclature in Peripheral Artery (말초 동맥 분광 도플러 파형 해석 및 명명법에 대한 고찰)

  • Ji, Myeong-Hoon;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.649-660
    • /
    • 2022
  • In 1959, Satomura used spectral Doppler ultrasound to express the velocity of red blood cells according to time change, and Kato defined a zero-base line that could tell the direction of blood flow, making it possible to know the direction of blood flow. This became the basis for the widely used classifications of Triphasic, Biphasic, and Monophasic. However, the above classification has limitations that confuse users with the meaning and timing of use in a clinical environment. As a result, the American Society for Vascular Medicine (SVM) and the Society for Vascular Ultrasound (SVU) A consensus document on Doppler waveform analysis was declared by the joint committee. This study tried to review this consensus and to suggest nomenclature and modifiers that can be used in the domestic vascular ultrasound clinical field. The joint committee formed by SVM and SVU recommended that the use of the triphasic waveform and the biphasic waveform be used as a multiphasic waveform rather than being used due to the ambiguity of interpretation. In addition, it was agreed to name the hybrid-type waveform, which is a monophasic and high-resistance waveform, which has always been a problem of interpretation in a clinical environment, as an intermediate resistive waveform. In addition, in order to increase the communication efficiency between the interpreter and the sonographer, waveform analysis was classified into a main descriptor and a modifier, and it was recommended to use a single nomenclature by unifying various synonyms. It is expected that this literature review will provide accurate arterial spectral Doppler waveform interpretation and an agreed-upon nomenclature to radiologists performing vascular ultrasound examination in clinical practice, and will be utilized as basic data that can contribute to the improvement of public health.

A Study on the Establishment of Acceptable Range for Internal Quality Control of Radioimmunoassay (핵의학 검체검사 내부정도관리 허용범위 설정에 관한 고찰)

  • Young Ji, LEE;So Young, LEE;Sun Ho, LEE
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.43-47
    • /
    • 2022
  • Purpose Radioimmunoassay implement quality control by systematizing the internal quality control system for quality assurance of test results. This study aims to contribute to the quality assurance of radioimmunoassay results and to implement systematic quality control by measuring the average CV of internal quality control and external quality control by plenty of institutions for reference when setting the laboratory's own acceptable range. Materials and Methods We measured the average CV of internal quality control and the bounce rate of more than 10.0% for a total of 42 items from October 2020 to December 2021. According to the CV result, we classified and compared the upper group (5.0% or less), the middle group (5.0~10.0%) and the lower group (10.0% or more). The bounce rate of 10.0% or more was compared by classifying the item of five or more institutions into tumor markers, thyroid hormones and other hormones. The average CV was measured by the overall average and standard deviation of the external quality control results for 28 items from the first quarter to the fourth quarter of 2021. In addition, the average CV was measured by the overall average and standard deviation of the proficiency results between institutions for 13 items in the first half and the second half of 2021. The average CV of internal quality control and external quality control was compared by item so we compared and analyzed the items that implement well to quality control and the items that require attention to quality control. Results As a result of measuring the precision average of internal quality control for 42 items of six institutions, the top group (5.0% or less) are Ferritin, HGH, SHBG, and 25-OH-VitD, while the bottom group (≤10.0%) are cortisol, ATA, AMA, renin, and estradiol. When comparing more than 10.0% bounce rate of CV for tumor markers, CA-125 (6.7%), CA-19-9 (9.8%) implemented well, while SCC-Ag (24.3%), CA-15-3 (26.7%) were among the items that require attention to control. As a result of comparing the bounce rate of more than 10.0% of CV for thyroid hormones examination, free T4 (2.1%), T3 (9.3%) showed excellent performance and AMA (39.6%), ATA (51.6%) required attention to control. When comparing the bounce rate of 10.0% or more of CV for other hormones, IGF-1 (8.8%), FSH (9.1%), prolactin (9.2%) showed excellent performance, however estradiol (37.3%), testosterone (37.7%), cortisol (44.4%) required attention to control. As a result of measuring the average CV of the whole institutions participating at external quality control for 28 items, HGH and SCC-Ag were included in the top group (≤10.0%), however ATA, estradiol, TSI, and thyroglobulin included in bottom group (≥30.0%). Conclusion As a result of evaluating 42 items of six institutions, the average CV was 3.7~12.2% showing a 3.3 times difference between the upper group and the lower group. Cortisol, ATA, AMA, Renin and estradiol tests with high CV will require continuous improvement activities to improve precision. In addition, we measured and compared the overall average CV of the internal quality control, the external quality control and the proficiency between institutions participating of six institutions for 41 items excluding HBs-Ab. As a result, ATA, AMA, Renin and estradiol belong to the same subgroup so we require attention to control and consider setting a higher acceptable range. It is recommended to set and control the acceptable range standard of internal quality control CV in consideration of many things in the laboratory due to the different reagents and instruments, and the results vary depending on the test's proficiency and quality control materials. It is thought that the accuracy and reliability of radioimmunoassay results can be improved if systematic quality control is implemented based on the set acceptable range.

A Study on the Measurement of Bacterial Contamination of MRI Examination Equipment and Disinfection Conditions (자기공명영상검사장비의 세균오염도 측정 및 소독에 관한 연구)

  • Jeung, Seung-Woon;Lim, Chung-Hwan;You, In-Gyu
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.665-672
    • /
    • 2013
  • In radiology department, where patients with a variety of diseases receive their tests, there is a large possibility of cross contamination of nosocomial infection. Magnetic resonance imaging (MRI) tests take particularly more time than other tests do, which increases the possibility of being exposed to cross contamination. Therefore, this research examines the status of MRI equipment sterilization and investigates the bacterial distribution on head coils, which have the most frequent contact with patients, patient fixation blocks, and bores, which are confined spaces. The status of MRI equipment disinfection was examined by a survey targeting 150 employees, and the distribution of bacteria was measured in ten medical facilities. The result of bacterial distribution tests on MRI equipment showed various bacteria, including Staphylococcus, Acinetobacter, Sphingomona, Pantoea agglomeranss, Micrococcus, Bacillus, Saprophyticus, Brevundimona, and Myroidesspecies. The result of examining the stat us of MRI room disinfection showed that the disinfections of the head coil, block, and bore were implemented well, and the largest proportion was carried out once a day in the morning. The time and implementation of disinfection by the disinfection manager showed that they were implemented well when the manager was the MRI room examiner. The disinfection after examining a patient using an appropriate disinfectant is mandatory to prevent cross contamination.

A Literature Review and A Clinical Examination of Burning Acupuncture Therapy of using D.I.T.I. (화침요법(火鍼療法)의 연구동향(硏究動向)과 D.I.T.I를 활용(活用)한 임상적(臨床的) 고찰(考察))

  • Park Sang-Jun;Ahn Soo-Gi
    • Journal of Acupuncture Research
    • /
    • v.15 no.2
    • /
    • pp.407-425
    • /
    • 1998
  • We have studied the clinical application of burning acupuncture by examining 18recent-published papers in the journal 'ZHONGGUO ZHENJIU(中國鍼灸)' for the bibliographical study and clinical study and have given medical treatment of burning acupuncture on 21 Patients who suffered 'the body chill symptoms(冷症)' at the oriental hospital of Won-Kwang University, Kwang-Ju. As a result, we have come to some conclusions as below. 1. The diseases for which the modern borning acupuncture is efficacious are widely extended to various kinds of field such as surgery, internal medicine, gynecology, ophthalmology, otolaryngology. etc. as well as numbness, meridian muscle disease(經筋病) mentioned in 'Neijing(內徑)' . 2. The effects of burning acupuncture therapy are wen zhuang yang qi(溫壯陽氣), sheng ji lian chuang(生肌斂瘡), san han chu shi(散寒除濕), qu fens zhi yang(祛風止痒), qu yu chu fu pai nong(祛瘀除腐排膿), san jie xiao zhong(散結消腫), zhi tong huan ji chu ma mu(止痛緩急除麻木), qing re xie hue jie du(淸熱瀉火解毒). 3. The recently reported diseases for which burning acupuncture is good are internal and external humeral epicondylitis, atheroma, menorrhalgia, thecal cyst, tragomaschalia, pruritus, traumatic onychophemia, gout of feet, prostatomegaly, aacne, supprative infection of body surface, snapping finger, backache, numbness, pyocyst etc. 4. The subjective symptoms of 'the body chill symptoms(冷症)' were, most of all, feeling cold accompanied by pain(16 case), while just 4 cases were feeling cold only. 5. In the related diseases of the body chill symptoms(冷症), feeling pain like arthralgia was the most case, and then dysmenorrhea, menorralgia, depression, anemia in order. 6. In the D.I.T.I before and after burning acupuncture treatment, 6 patients had shown 'excellent' effects and 8 patients had turned out 'good', while 7 patients had become'fair'. 7. In the degree of patient-satisfaction, 5 patients announced 'excellence' and 6 patients expressed 'good', 4 expressed 'fair', while the other 6 showed no change. 8. In the correlation of D.I.T.I and patient-satisfaction, the better the result of clinical treatment was, the more satisfied the patient was, however, in the case 'fair', we saw the degree of patient-satisfaction was relatively low, so we could admit the judging significance of D.I.T.I.

  • PDF

Development of Health Service Weight for Resource Allocation and Performance Monitoring (자원 배분과 성과 모니터링을 위한 보건사업 가중치 개발)

  • Kim, Sang-A.;Hur, Young-Hye;Park, Woong-Sub
    • Journal of agricultural medicine and community health
    • /
    • v.34 no.1
    • /
    • pp.34-46
    • /
    • 2009
  • Objectives: This study was conducted to estimate health service weight for resource allocation and performance monitoring using Basic Priority Rating System. Methods: The Health service would be classified according to New Health Plan 2010, and Burden of disease collected from preceding studies. The data of severity of health problem and effectiveness of intervention were collected through the survey of experts' suggestion. The health service weight was estimated in the formula which is Basic Priority Rating System. Results: In the result of analysis, the health service weight of Infectious disease was ranked highest at 58.97% followed by Anti-smoking campaign(14.07%), Hypertension(3.87%), Diabetes mellitus(3.40%), Cancer(2.90%), Cardiovascular-Cerebrovascular diseases(2.86%), Physical activity(2.10%), Moderate drinking(2.07%), Medical examination(1.92%), Mental health promotion(1.72%), Serious mental illnesses(1.62%), Nutrition(1.52%), Oral health promotion(1.15%), Oral diseases(1.10%), Addiction(0.73%). Conclusions: We think the result of this study provides a rational basis for resource allocation and performance monitoring of health service.