• Title/Summary/Keyword: Medical Capability

Search Result 343, Processing Time 0.022 seconds

The Effect of Speed-dependent with Body Weight Supported Treadmill Training on the Ambulation of Stroke (속도-의존적 체중지지 트레드밀 보행이 뇌졸중 환자의 보행에 미치는 영향)

  • Kim, Jwa-Jun;Rho, Min-He;Goo, Bong-Oh;Ahn, So-Youn
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.3
    • /
    • pp.339-350
    • /
    • 2005
  • This study is the quasi-experimental study on the gait training rehabilitation. The purpose of this study is to prepare the baseline data for most suitable of gait while we were scrutinizing how the walking characters, functional walking ability, gait quality of stroke patients were affected by the gait on BWSTT (Body Weight Supported Treadmill Training) through the change of treadmill velocity and body weight support. To accomplish this purpose, this study used thirty subjects, more than 3 months post stroke, for rehabilitation who were divided between two gait training groups they received the neurophysiological physical therapy. For 6 weeks, 5 times a week for 15 minutes per session, the BWSTT group participated in 30 sessions structured speed-dependent treadmill training with 30% body weight supported, and the ratio of body weight support was gradually decreased as the patients advanced the capability of more self-support. The OGT(Over Ground Training) group received the same quantity of equal sessions like BWSTT. Firstly, we measured the absolute improvement of walking velocity (m/s), capacity(min/m) and cadence(steps/min) among walking characters. Secondly, we measured the functional walking ability such as Functional Ambulatory Category(FAC, score out of 5), Modified Motor Assesment Scale(MMAS, score out of 6) and Gait Quality Chart(score out of 41). Data analysis was performed with using SPSS 10.0 win program. The descriptive analysis was used to obtain average and standard deviation. The independent t-test and the paired t-test were used to compare both the groups about pre and post training test. Treatment effects were established by pre and post assessment. Subjects tolerated the training well without side-effects. Therefore, the results of this study were as follows; 1. There was a more significant difference from the improvement of walking velocity(0.09m/s), endurance(4.53min/m), cadence(4.20steps/min), FAC(0.26score), MMAS(0.33 score) and hip joint and pelvic of gait quality(0.39 score) ever before in the BWSTT group(p<.05). 2. There was a more significant increase from the walking velocity(0.01m/s) in the OGT group(p<.05). 3. There was a more statistical significant increase from comparing the average of walking velocity in both groups ever before(0.42m/s in BWSTT group and 0.31m/s in OGT group)(p<.05). There was a statistical significant difference from the average of cadence in both groups(61.87step/min in BWSTT group and 3.60steps/min in OGT group)(p<.05). As we can see from above, the findings suggest that BWSTT may be more effective than the OGT for improving some gait parameters such as gait velocity and cadency. This conclusion also suggest that BWSTT is more effective for the improvement of gait of stroke patients.

  • PDF

Anti-cancer Activity of Lentinus edoeds and Pleurotus astreatus (표고버섯과 느타리 버섯의 항암효과)

  • Park, Moo-Hyun;Oh, Kook-Yong;Lee, Byung-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.702-708
    • /
    • 1998
  • The effects of mushrooms such as Lentinus edodes and Pleurotus ostreatus on anti-cancer activity through in vivo and in vitro experiments were powders of protein-bound polysaccharides in mushrooms were solubilized in 0, 5, 25 mg/kg saline, respectively and were used in vitro experiments. The in vivo experiments were carried out as followed: i) anti-cancer activities on Leukemia $(L_{1210})$, Hepatlicus cancer $(H_{22})$ and Sarcoma180/(S180), and ii) the effect on immune system through changes in intestine weight and the number of hemolytic plague forming cells. Protein-bound polysaccharides of all showed anti-cancer activity on $L_{1210}$ and fruit body of Lentinus edodes 25 mg/kg treatment group showed the highest inhibition rate (86%). Pleurotus ostreatus mycelial in medium of cultivate 25 mg/kg treatment. Fruid body of Lentinus edodes 25 mg/kg treatment group showed the highest inhibition rate (86% and 71%, respectively) on $H_{22}$ among them. The inhibition rates of fruit body and mycelial of Lentinus edodes 25 mg/kg treatment groups on S180 were 33.9% and 30.9%, respectively. Each samples of 50, 100, 200, $400\;{\mu}g/{\mu}L$ on in vitro cell toxicity test did not show significantly different cell death rates at P<0.05. In immune test, weights of liver and spleen were increased according to increase in conc. but were not significantly different at P<0.05. The weights of thymus were heavy in fruit body and mycelial of Lentinus edodes treatment group but were not significantly different at P<0.05. Hemolytic plague forming cells with antibody formation capability were significantly high in fruit body and mycelial of Lentinus edodes treatment samples.

  • PDF

Investigation of the Clinical Pathology Department Student Satisfaction and Their Recognition of Employment in Gwangju-Jeonnam Province (광주·전남 임상병리과 재학생의 학과만족도 및 취업에 대한 의식도 조사)

  • Hwang, Goo-Yeon;Cho, Young-Kuk
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.42 no.1
    • /
    • pp.55-61
    • /
    • 2010
  • This investigation has been carried out for the purpose of the examination of current Gwangju and Jeonnam clinical pathology students' recognition of their departments and of effective employment guidance. Furthermore, it has examined the students' recognition on two sides; namely, their satisfaction with their own departments and their recognition of the employment of medical technologists. This investigation, with 389 students as its subjects from the clinical pathology departments at 4 universities in the Gwangju-Jeonnam Region, has compared and analyzed the data from the survey with a questionnaire from November 2008 to June 2009 by using the SPSS 12.0 package. Some of the remarkable results from the yielded data are as follows. As for the motivation for their application to the clinical pathology departments, the investigation of the students' satisfaction with their departments has revealed that 47.5% of the subjects indicated recommendation from friends or acquaintances while 22.1% reported that they had been informed of the departments through Internet. 70.4% of the subjects graduated from general high schools, 22.3% from commercial high schools, and 6.2% from technical high schools. Applicants from general high schools tend to decrease in number every year. 28.5% of the students judged professor's capability of lecture as an important part of their acquisition of licenses, and more than 65.6% of the subjects acknowledged the necessity of their self-study at night for the acquisition of license. As for the future prospect of the occupation of clinical technologist, 46.8% of the students replied that it was promising, while 39.1% reported that they had no ideas. From this we can confirm that the students of clinical pathology lacked a viewpoint of occupation and goals for future jobs. The investigation of the students'recognition of the employment of clinical technologists has revealed that 47.8% of them wanted to be employed in the Seoul-Gyeonggi Region due to the properties of their local universities, 29.0% of themlogpecteties of monesly salary to be 1,200,000~1,300,000 won, while 22.4% 1,300,000~1,400,000 won. These fiemres indicated that these students' salary ogpectations were relativplo lower than those from cities ertiprovinces. As for the greatest difficulty after employment, 31.1% of the subjects indicated the confliction among employees from variouatiolleges, 27.3% uncertainty of duties related to es of major, 24.9% bmrdens of self-development.

  • PDF

A Study on Projection Image Restoration by Adaptive Filtering (적응적 필터링에 의한 투사영상 복원에 관한 연구)

  • 김정희;김광익
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.119-128
    • /
    • 1998
  • This paper describes a filtering algorithm which employs apriori information of SPECT lesion detectability potential for the filtering of degraded projection images prior to the backprojection reconstruction. In this algorithm, we determined m minimum detectable lesion sized(MDLSs) by assuming m object contrasts uniformly-chosen in the range of 0.0-1.0, based on a signal/noise model which provides the capability potential of SPECT in terms of physical factors. A best estimate of given projection image is attempted as a weighted combination of the subimages from m optimal filters whose design is focused on maximizing the local S/N ratios for the MDLS-lesions. These subimages show relatively larger resolution recovery effect and relatively smaller noise reduction effect with the decreased MDLS, and the weighting on each subimage was controlled by the difference between the subimage and the maximum-resolution-recovered projection image. The proposed filtering algoritym was tested on SPECT image reconstruction problems, and produced good results. Especially, this algorithm showed the adaptive effect that approximately averages the filter outputs in homogeneous areas and sensitively depends on each filter strength on contrast preserving/enhancing in textured lesion areas of the reconstructed image.

  • PDF

Acoustic Analysis and Auditory-Perceptual Assessment for Diagnosis of Functional Dysphonia (기능성 음성장애의 진단을 위한 음향학적, 청지각적 평가)

  • Kim, Geun-Hyo;Lee, Yeon-Yoo;Bae, In-Ho;Lee, Jae-Seok;Lee, Chang-Yoon;Park, Hee-June;Lee, Byung-Joo;Kwon, Soon-Bok
    • Journal of Clinical Otolaryngology Head and Neck Surgery
    • /
    • v.29 no.2
    • /
    • pp.212-222
    • /
    • 2018
  • Background and Objectives : The purpose of this study was to compare the measured values of acoustic and auditory perceptual assessments between normal and functional dysphonia (FD) groups. Materials and Methods : 102 subjects with FD and 59 normal voice groups were participated in this study. Mid-vowel portion of the sustained vowel /a/ and two sentences of 'Sanchaek' were edited, concatenated, and analyzed by Praat script. And then auditory-perceptual (AP) rating was completed by three listeners. Results : The FD group showed higher acoustic voice quality index version 2.02 and version 3.01 (AVQIv2 and AVQIv3), slope, Hammarberg index (HAM), grade (G) and overall severity (OS), values than normal group. Additionally, smoothed cepstral peak prominence in Praat (PraatCPPS), tilt, low-to high spectral band energies (L/H ratio), long-term average spectrum (LTAS) in FD group were lower than normal voice group. And the correlation among measured values ranged from -0.250 to 0.960. In ROC curve analysis, cutoff values of AVQIv2, AVQIv3, PraatCPPS, slope, tilt, L/H ratio, HAM, and LTAS were 3.270, 2.013, 13.838, -22.286, -9.754, 369.043, 27.912, and 34.523, respectively, and the AUC of each analysis was over .890 in AVQIv2, AVQIv3, and PraatCPPS, over 0.731 in HAM, tilt, and slope, over 0.605 in LTAS and L/H ratio. Conclusions : In conclusion, AVQI and CPPS showed the highest predictive power for distinguishing between normal and FD groups. Acoustic analyses and AP rating as noninvasive examination can reinforce the screening capability of FD and help to establish efficient diagnosis and treatment process plan for FD.

A low noise, wideband signal receiver for photoacoustic microscopy (광음향 현미경 영상을 위한 저잡음 광대역 수신 시스템)

  • Han, Wonkook;Moon, Ju-Young;Park, Sunghun;Chang, Jin Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.507-517
    • /
    • 2022
  • The PhotoAcoustic Microscopy (PAM) has been proved to be a useful tool for biological and medical applications due to its high spatial and contrast resolution. PAM is based on transmission of laser pulses and reception of PA signals. Since the strength of PA signals is generally low, not only are high-performance optical and acoustic modules required, but high-performance electronics for imaging are also particularly needed for high-quality PAM imaging. Most PAM systems are implemented with a combination of several pieces of equipment commercially available to receive, amplify, enhance, and digitize PA signals. To this end, PAM systems are inevitably bulky and not optimal because general purpose equipment is used. This paper reports a PA signal receiving system recently developed to attain the capability of improved Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of PAM images; the main module of this system is a low noise, wideband signal receiver that consists of two low-noise amplifiers, two variable gain amplifiers, analog filters, an Analog to Digital Converter (ADC), and control logic. From phantom imaging experiments, it was found that the developed system can improve SNR by 6.7 dB and CNR by 3 dB, compared to a combination of several pieces of commercially available equipment.

Ultrasound-optical imaging-based multimodal imaging technology for biomedical applications (바이오 응용을 위한 초음파 및 광학 기반 다중 모달 영상 기술)

  • Moon Hwan Lee;HeeYeon Park;Kyungsu Lee;Sewoong Kim;Jihun Kim;Jae Youn Hwang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.429-440
    • /
    • 2023
  • This study explores recent research trends and potential applications of ultrasound optical imaging-based multimodal technology. Ultrasound imaging has been widely utilized in medical diagnostics due to its real-time capability and relative safety. However, the drawback of low resolution in ultrasound imaging has prompted active research on multimodal imaging techniques that combine ultrasound with other imaging modalities to enhance diagnostic accuracy. In particular, ultrasound optical imaging-based multimodal technology enables the utilization of each modality's advantages while compensating for their limitations, offering a means to improve the accuracy of the diagnosis. Various forms of multimodal imaging techniques have been proposed, including the fusion of optical coherence tomography, photoacoustic, fluorescence, fluorescence lifetime, and spectral technology with ultrasound. This study investigates recent research trends in ultrasound optical imaging-based multimodal technology, and its potential applications are demonstrated in the biomedical field. The ultrasound optical imaging-based multimodal technology provides insights into the progress of integrating ultrasound and optical technologies, laying the foundation for novel approaches to enhance diagnostic accuracy in the biomedical domain.

Micro-CT System for Small Animal Imaging (소동물영상을 위한 마이크로 컴퓨터단층촬영장치)

  • Nam, Ki-Yong;Kim, Kyong-Woo;Kim, Jae-Hee;Son, Hyun-Hwa;Ryu, Jeong-Hyun;Kang, Seoung-Hoon;Chon, Kwon-Su;Park, Seong-Hoon;Yoon, Kwon-Ha
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.102-112
    • /
    • 2008
  • We developed a high-resolution micro-CT system based on rotational gantry and flat-panel detector for live mouse imaging. This system is composed primarily of an x-ray source with micro-focal spot size, a CMOS (complementary metal oxide semiconductor) flat panel detector coupled with Csl (TI) (thallium-doped cesium iodide) scintillator, a linearly moving couch, a rotational gantry coupled with positioning encoder, and a parallel processing system for image data. This system was designed to be of the gantry-rotation type which has several advantages in obtaining CT images of live mice, namely, the relative ease of minimizing the motion artifact of the mice and the capability of administering respiratory anesthesia during scanning. We evaluated the spatial resolution, image contrast, and uniformity of the CT system using CT phantoms. As the results, the spatial resolution of the system was approximately the 11.3 cycles/mm at 10% of the MTF curve, and the radiation dose to the mice was 81.5 mGy. The minimal resolving contrast was found to be less than 46 CT numbers on low-contrast phantom imaging test. We found that the image non-uniformity was approximately 70 CT numbers at a voxel size of ${\sim}55{\times}55{\times}X100\;{\mu}^3$. We present the image test results of the skull and lung, and body of the live mice.

  • PDF

Development of Position Encoding Circuit for a Multi-Anode Position Sensitive Photomultiplier Tube (다중양극 위치민감형 광전자증배관을 위한 위치검출회로 개발)

  • Kwon, Sun-Il;Hong, Seong-Jong;Ito, Mikiko;Yoon, Hyun-Suk;Lee, Geon-Song;Sim, Kwang-Souk;Rhee, June-Tak;Lee, Dong-Soo;Lee, Jae-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.469-477
    • /
    • 2008
  • Purpose: The goal of this paper is to present the design and performance of a position encoding circuit for $16{\times}16$ array of position sensitive multi-anode photomultiplier tube for small animal PET scanners. This circuit which reduces the number of readout channels from 256 to 4 channels is based on a charge division method utilizing a resistor array. Materials and Methods: The position encoding circuit was simulated with PSpice before fabrication. The position encoding circuit reads out the signals from H9500 flat panel PMTs (Hamamatsu Photonics K.K., Japan) on which $1.5{\times}1.5{\times}7.0\;mm^3$ $L_{0.9}GSO$ ($Lu_{1.8}Gd_{0.2}SiO_{5}:Ce$) crystals were mounted. For coincidence detection, two different PET modules were used. One PET module consisted of a $29{\times}29\;L_{0.9}GSO$ crystal layer, and the other PET module two $28{\times}28$ and $29{\times}29\;L_{0.9}GSO$ crystal layers which have relative offsets by half a crystal pitch in x- and y-directions. The crystal mapping algorithm was also developed to identify crystals. Results: Each crystal was clearly visible in flood images. The crystal identification capability was enhanced further by changing the values of resistors near the edge of the resistor array. Energy resolutions of individual crystal were about 11.6%(SD 1.6). The flood images were segmented well with the proposed crystal mapping algorithm. Conclusion: The position encoding circuit resulted in a clear separation of crystals and sufficient energy resolutions with H9500 flat-panel PMT and $L_{0.9}GSO$ crystals. This circuit is good enough for use in small animal PET scanners.

Predictive Factors of Health promotion behaviors of Industrial Shift Workers (산업장 교대근무 근로자의 건강증진행위 예측요인)

  • Kim, Young-Mi
    • Korean Journal of Occupational Health Nursing
    • /
    • v.11 no.1
    • /
    • pp.13-30
    • /
    • 2002
  • Industrial shift workers feels suffer mental stresses which are caused by unfamiliar day sleep, noisy environment, sleeping disorder by bright light, unusual contacts with family, difficulty in meeting with friends or having formal social meetings and other social limitations such as the use of transportation. Such stresses influence health of the workers negatively. Thus the health promotion policy for shift workers should be made considering the workers' ways of living and shift work specially. This study attempted to provide basic information for development of the health promotion program for industrial shift workers by examining predictive factors influencing health promotion behaviors of those workers. In designing the study, three power generation plants located in Pusan and south Kyungsang province were randomly selected and therefrom 280 workers at central control, boiler and turbine rooms and environmental chemistry parts whose processes require shift works were sampled as subjects of the study. Data were collected two times from September 17 to October 8, 1999 using questionnaires with helps of safety and health managers of the plants. The questionnaires were distributed through mails or direct visits. Means for the study included the measurement tool of health promotion behavior provided by Park(1995), the tool of self-efficacy measurement by Suh(1995), the tool of internal locus of control measurement by Oh(1987), the measurement tool of perceived health state by Park(1995) and the tool of social support measurement by Paek(1995). The collected data were analyzed using SPSS program. Controlling factors of the subjects were evaluated in terms of frequency and percentage ratio Perceived factors and health promotion behaviors of the subjects were done so in terms of mean and standard deviation, and average mark and standard deviation, respectively. Relations between controlling and perceived factors were analyzed using t-test and ANOVA and those between perceived factors and the performance of health promotion behaviors, using Pearson's Correlation Coefficient. The performance of health promotion behaviors was tested using t-test, ANOVA and post multi-comparison (Scheffe test). Predictive factors of health promotion behavior were examined through the Stepwise Multiple Regression Analysis. Results of the study are summarized as follows. 1. The performance of health promotion behaviors by the subjects was evaluated as having the value of mean, $161.27{\pm}26.73$ points(min.:60, max.:240) and average mark, $2.68{\pm}0.44$ points(min.:1, max.:4). When the performance was analyzed according to related aspects, it showed the highest level in harmonious relation with average mark, $3.15{\pm}.56$ points, followed by hygienic life($3.03{\pm}.55$), self-realization ($2.84{\pm}.55$), emotional support($2.73{\pm}.61$), regular meals($2.71{\pm}.76$), self-control($2.62{\pm}.63$), health diet($2.62{\pm}.56$), rest and sleep($2.60{\pm}.59$), exercise and activity($2.53{\pm}.57$), diet control($2.52{\pm}.56$) and special health management($2.06{\pm}.65$). 2. In relations between perceived factors of the subjects(self-efficacy, internal locus of control, perceived health state) and the performance of health promotion behaviors, the performance was found having significantly pure relations with self-efficacy (r=.524, P=.000), internal locus of control (r=.225, P=.000) and perceived health state(r=.244, P=.000). The higher each evaluated point of the three factors was, the higher the performance was in level. 3. When relations between the controlling factors(demography-based social, health-related, job-related and human relations characteristics) and the performance of health promotion behaviors were analyzed, the performance showed significant differences according to marital status (t=2.09, P= .03), religion(F=3.93, P= .00) and participation in religious activities (F=8.10, P= .00) out of demography-based characteristics, medical examination results (F=7.20, P= .00) and methods of the collection of health knowledge and information(F=3.41, P= .01) and methods of desired health education(F=3.41, P= .01) out of health-related characteristics, detrimental factors perception(F=4.49, P= .01) and job satisfaction(F=8.41, P= .00) out of job-related characteristics and social support(F=14.69, P= .00) out of human relations characteristics. 4. The factor which is a variable predicting best the performance of health promotion behaviors by the subjects was the self-efficacy accounting for 27.4% of the prediction, followed by participation in religious activities, social support, job satisfaction, received health state and internal locus of control in order all of which totally account for 41.0%. In conclusion, the predictive factor which most influence the performance of health promotion behaviors by shift workers was self-efficacy. To promote the sense, therefore, it is necessary to develop the nursing intervention program considering predictive factors as variables identified in this study. Further industrial nurses should play their roles actively to help shift workers increase their capability of self-management of health.

  • PDF