• Title/Summary/Keyword: Median value

Search Result 778, Processing Time 0.023 seconds

Concentrations and Exposure Levels via Intake of Phthalates in Dust Deposits in Indoor Children's Living Areas: Focusing on DEHP (어린이가 생활하는 실내공간의 바닥먼지 중 프탈레이트 농도와 노출수준: DEHP를 중심으로)

  • Jeon, Seong-ho;Kim, Kyung-hee;Choi, Jae-wook
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.1
    • /
    • pp.52-58
    • /
    • 2022
  • Background: Few studies have evaluated the exposure to phthalates via inhalation of floor dust in children's living areas. Objectives: This study evaluated the concentration and exposure level of phthalates emitted from indoor floor dust in children's living areas. Methods: This study utilized the results of a survey conducted by the Ministry of Environment in 2019. Indoor dust was collected from 150 households with children aged 3~7 and 67 daycare centers or local children's centers by using vacuum cleaners. It was analyzed by gas chromatography mass spectrometry. Six types of phthalates were analyzed: Bis (2-ethylhexyl) phthalate (DEHP), Dibutyl phthalate (DBP), Benzyl butyl phthalate (BBP), Di-N-octyl phthalate (DNOP), Diisononyl phthalate (DINP), Di -isodecyl phthalate (DIDP). Results: The medians of DEHP concentrations were 1,028 and 1,937 mg/kg in homes and daycare centers, respectively. The median and maximum values of daily intake were calculated by applying the median and 95th percentile values (the upper 5% of the total concentration) in dust measured in the homes. The DEHP median value was 1.6 ㎍/kg/bw/day, and a maximum A value of 7.8 ㎍/kg/bw/day was calculated. When the childcare center values were applied, the median daily intake of DEHP was 3.1 ㎍/kg/bw/day and the maximum value was 29.2 ㎍/kg/bw/day. As a result of calculating the daily intake by integrating the values of home and childcare facilities, the median and maximum values of daily intake were 1.9 and 10.9 ㎍/kg/bw/day, respectively. Conclusions: This study derives phthalate concentrations among the floor dust in homes and childcare facilities where children mainly spend time, and suggests their intake of phthalates through this. In particular, it was newly suggested that the phthalate concentrations in homes and childcare facilities are different, resulting in differences in intake.

Performance Comparisons of some nonparametric detectors (몇가지 비모수 검파기의 성능 비교)

  • 김홍길;송익호;장태주;배진수
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1996.06a
    • /
    • pp.9-15
    • /
    • 1996
  • In this paper, we propose a new detector based on the median-shift sign. We call it the median-shift sign (MSS) detector, which is an extension of the classical sign detector. We first analyze the problem of detecting a dc signal in noise of known probability density function (pdf). The MSS detector with the optimum median-shift value, the optimum MSS detector, performs better than the sign detector in Gaussian noise: it has the best performance among the detectors compared in Laplacian and Cauchy noise. It is shown that the MSS detectors with constant median-shift values are nearly equal to the optimum MSS detector. We also analyze the problem of detecting a dc signal when only partial information is available on the noise. The MSS detectors with constant median-shift values are almost equal to the sign detector in Gaussian noise: they perform better than the sign and Wilcoxon detectors for most signal ranges in Laplacian and Cauchy noise.

  • PDF

Application of Modified Median Filter for Grading Produce

  • Morio, Yoshinari;Ikeda, Yoshio
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.842-851
    • /
    • 1996
  • Median filter(MF) has often been applied to color or gray images as a noise fiilter in image processing . Application of MF to binary images was tried in this study. For binary images, MF not only can remove noise but can also work as an indicator showing the dominant color in a region which is called window . Fro example, MF can be used to categorize clusters and to detect interested parts of an object. In other words, MF can also be used to remove unnecessary parts. The function of MF can be intensified by introducing a thresholding value, which is determined by the size of the interested part of an object. This improved MF for binary images is called the modified median filter(MMF), and its applicability to grade produce will be discussed in this paper.

  • PDF

Development of Research Personnel Evaluation System Using Median Rank (Median Rank를 이용한 연구인력 평가 시스템)

  • 이성기;윤덕균
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.21 no.47
    • /
    • pp.169-179
    • /
    • 1998
  • Median rank is used to systemize the evaluation of research personnel in a research institution. Suggested evaluation system is purposed to enhance the fairness, distinguish the factors of evaluation and maximize the synergy of researchers. The factors of evaluation are largely divided into the subjective and the objective factor. The final rank of the researchers is determined with the converted median rank value. The propriety of applying median rank is tested by Spearman's rank correlation coefficient. We also suggest the method of determining the rank of researchers. This evaluation system is not fixed in special case but can be changed in situation. It also can be applied to any other personnel evaluation system through the appropriate revision.

  • PDF

Efficient Median Filter Using Irregular Shape Window

  • Pok, Gou Chol
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.5
    • /
    • pp.601-607
    • /
    • 2018
  • Median filtering is a nonlinear method which is known to be effective in removing impulse noise while preserving local image structure relatively well. However, it could still suffer the smearing phenomena of edges and fine details into neighbors due to undesirable influence from the pixels whose values are far off from the true value of the pixel at hand. This drawback mainly comes from the fact that median filters typically employ a regular shape window for collecting the pixels used in the filtering operation. In this paper, we propose a median filtering method which employs an irregular shape filter window in collecting neighboring pixels around the pixel to be denoised. By employing an irregular shape window, we can achieve good noise suppression while preserving image details. Experimental results have shown that our approach is superior to regular window-based methods.

The Effect of Using Smart-Phones on Neck and Shoulder Muscle Activities and Fatigue (핸드폰 사용이 목과 어깨 근육의 근육활성도와 피로도에 미치는 영향)

  • Park, Joo-Hee;Kang, Sun-Young;Jeon, Hye-Seon
    • Physical Therapy Korea
    • /
    • v.20 no.3
    • /
    • pp.19-26
    • /
    • 2013
  • The smart-phone has become a necessity for most people. In this study, we determined that using a smart-phone for 20 minutes can cause increased neck and shoulder muscle activities and fatigue. Seventeen healthy male smart-phone users who attended Yonsei University played a smart-phone game for 20 minutes and changes in their bilateral cervical erector spinae and upper trapezius muscle activities and fatigue were measured. To assess muscle activities and fatigue, we used the following variables: the median frequency, the 50th percentile Amplitude probability distribution function (APDF) value (median load), and the discrepancy in the 90th percentile APDF value and the 10th percentile APDF value (APDF range). A paired t-test was used to compare pre-smart-phone-use status with post-smart-phone-use-status. The median frequency of the bilateral cervical erector spinae and the upper trapezius decreased significantly after 20 minutes of smart-phone use (p<.05). In addition, the 50th percentile APDF value of the bilateral cervical erector spinae and the right upper trapezius increased significantly (p<.05). The APDF range of the bilateral cervical erector spinae and the upper trapezius also increased significantly (p<.05). However, the 50th percentile APDF range of the left upper trapezius was not significantly different (p>.05). These findings suggest that using smart-phones for 20 minutes can induce muscle fatigue and increased neck and shoulder muscle activities.

Downscaling Forgery Detection using Pixel Value's Gradients of Digital Image (디지털 영상 픽셀값의 경사도를 이용한 Downscaling Forgery 검출)

  • RHEE, Kang Hyeon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.2
    • /
    • pp.47-52
    • /
    • 2016
  • The used digital images in the smart device and small displayer has been a downscaled image. In this paper, the detection of the downscaling image forgery is proposed using the feature vector according to the pixel value's gradients. In the proposed algorithm, AR (Autoregressive) coefficients are computed from pixel value's gradients of the image. These coefficients as the feature vectors are used in the learning of a SVM (Support Vector Machine) classification for the downscaling image forgery detector. On the performance of the proposed algorithm, it is excellent at the downscaling 90% image forgery compare to MFR (Median Filter Residual) scheme that had the same 10-Dim. feature vectors and 686-Dim. SPAM (Subtractive Pixel Adjacency Matrix) scheme. In averaging filtering ($3{\times}3$) and median filtering ($3{\times}3$) images, it has a higher detection ratio. Especially, the measured performances of all items in averaging and median filtering ($3{\times}3$), AUC (Area Under Curve) by the sensitivity and 1-specificity is approached to 1. Thus, it is confirmed that the grade evaluation of the proposed algorithm is 'Excellent (A)'.

A Study on Composite Filters for Salt and Pepper Noise Removal (Salt and Pepper 잡음 제거를 위한 복합 필터에 관한 연구)

  • Hong, Sang-Woo;Kwon, Se-Ik;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.409-411
    • /
    • 2016
  • Salt and pepper noise is caused by various causes such as camera malfunction, storage media memory error, and transmission channel error. Representative filters to remove salt and pepper noise include SMF(standard median filter), CWMF(center weighted median filter), and AMF(adaptive median filter). However previous filters have inadequate noise removal characteristics in high density salt-and-pepper noise environment. Therefore the study suggested a composite filter which, through noise evaluation, preserves original pixels when the central pixel is non-noise, and uses spatial weighted value mask and median when there is noise.

  • PDF

Feasibility study of improved median filtering in PET/MR fusion images with parallel imaging using generalized autocalibrating partially parallel acquisition

  • Chanrok Park;Jae-Young Kim;Chang-Hyeon An;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.222-228
    • /
    • 2023
  • This study aimed to analyze the applicability of the improved median filter in positron emission tomography (PET)/magnetic resonance (MR) fusion images based on parallel imaging using generalized autocalibrating partially parallel acquisition (GRAPPA). In this study, a PET/MR fusion imaging system based on a 3.0T magnetic field and 18F radioisotope were used. An improved median filter that can set a mask of the median value more efficiently than before was modeled and applied to the acquired image. As quantitative evaluation parameters of the noise level, the contrast to noise ratio (CNR) and coefficient of variation (COV) were calculated. Additionally, no-reference-based evaluation parameters were used to analyze the overall image quality. We confirmed that the CNR and COV values of the PET/MR fusion images to which the improved median filter was applied improved by approximately 3.32 and 2.19 times on average, respectively, compared to the noisy image. In addition, the no-reference-based evaluation results showed a similar trend for the noise-level results. In conclusion, we demonstrated that it can be supplemented by using an improved median filter, which suggests the problem of image quality degradation of PET/MR fusion images that shortens scan time using GRAPPA.

Radon Concentrations in Groundwater of the Goesan Area, Korea (괴산지역 지하수의 라돈 함량)

  • Cho, Byong-Wook
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.5
    • /
    • pp.63-70
    • /
    • 2017
  • Radon concentrations were measured in 250 groundwater samples collected from the Goesan area where uraniferous black slate and granites abundantly occur in the formations. The measured radon levels ranged from 0.90 to 7,218.7 Bq/L with the median value of 54.3 Bq/L, similar to the value measured in the nationwide survey in 4,853 wells (52.1 Bq/L). The median value was highest in the Cretaceous granite area (390.0 Bq/L) while it was as low as 20.0~58.8 Bq/L in the Ogcheon meta-sedimentary rock areas. About 23.6% of the total samples exceeded the WHO guideline value of 100 Bq/L established in 2011. The exceeding rate was 69.0, 39.4, and 7.0~13.7% in the Cretaceous granite area, Jurassic granite area, and Ogcheon meta-sedimentary rock areas, respectively.