• Title/Summary/Keyword: Median frequency(MDF)

검색결과 26건 처리시간 0.018초

AR모델을 이용한 중앙주파수의 근피로 변화에 관한 연구 (A Study on Muscle Fatigue Changes using AR Model-based Median Frequency in EMG)

  • 조은석;차샘;이상식;이기영
    • 한국정보전자통신기술학회논문지
    • /
    • 제2권1호
    • /
    • pp.17-22
    • /
    • 2009
  • 본 연구에서는 근전도의 근피로와 관계된 특징인자인 영교차율 및 저대역에너지, 푸리에변환과 AR모델에 의한 중앙주파수를 추출하여 근피로에 이를 때까지의 변화를 평가해 봄으로써 근피로 정도나 시점까지의 변화 정도를 비교 및 고찰하고자 한다. 측정 대상으로 20대 남녀 각각 3인이 참여하였으며 상완 이두근의 등장성운동으로 소진할 때까지의 근전도를 측정 기록하여 실험하였다.

  • PDF

최대수의적 수축훈련에 의한 앞 정강근의 근전도 신호의 변화 (Changes in Electromyogram Signals from the Tibialis Anterior Muscle Resulting from Maximal Voluntary Contraction Exercise)

  • 송수영;황기경;김문정;이정우
    • 대한임상전기생리학회지
    • /
    • 제9권2호
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose : This study aims to examine changes in electromyogram (EMG) signals detected from the tibialis anterior muscle during repetitive contraction exercises in normal female adults. Methods : The subjects of this study were 10 normal adult females without any musculoskeletal or nervous system disorders. A total of 30 contractions were made repetitively with maximal voluntary contraction exercise for six seconds and a resting time for three seconds. Changes in muscle contractions were measured using dynamometer and EMG signals such as root mean square (RMS), integrated EMG (IEMG), and median frequency (MDF). Results : The result of measurement showed no significant differences in IEMG and RMS in accordance with the increase in the number of contractions. MVIC and MDF showed significant differences in accordance with the increase in the number of contractions (p<0.05). Conclusion : This study demonstrated that repetitive tibialis anterior muscle contraction resulted in a significantly different MVIC and MDF but no significant differences in IEMG and RMS. Therefore, compared to other lower leg muscles, the tibialis anterior muscle is a low-frequency muscle and therefore electrophysiological characteristics of the muscle should be considered in different exercise methods.

슬관절 신전근의 등속성 운동 시 발생되는 일과 근전도 신호와의 관계 (Relationship between EMG Signals and Work during Isokinetic Exercise of Knee Extensor)

  • 원종임
    • 대한물리치료과학회지
    • /
    • 제10권1호
    • /
    • pp.83-89
    • /
    • 2003
  • An electromyogram (EMG) using surface electrodes is one of the indirect tests most frequently used to ascertain muscle fatigue. An EMG can be used in two ways. The first technique determines the root mean square (RMS), which reflects the amplitude of the EMG signal. The second technique determines the median and mean power frequencies through EMG power spectrum analysis. The purpose of this article is for determine the correlation between work and percent root mean square(%RMS) and between work and MDF of EMG based on muscle contractions. It is used the %RMS, which reflects the amplitude of the EMG signal For MDF, it is used the frequency power spectrum analysis method, which involves the fast Fourier transformation (FFT) of the original Signals.

  • PDF

동력계 및 표면근전도를 이용한 정상인의 등척성 수축 시 성별 차이에 따른 대퇴직근의 피로 양상분석 (The Analysis of Rectus Femoris Muscle Fatigue Patterns According to Sex using Dynamometer and sEMG during Isometric Contraction to Normal Subjects)

  • 김용남
    • The Journal of Korean Physical Therapy
    • /
    • 제19권3호
    • /
    • pp.11-17
    • /
    • 2007
  • Purpose: The purpose of this study were to analyze fatigue patterns of the rectus femoris muscle by isometric contraction. Methods: Twenty healthy subjects(10 male, 10 female) participated in this study. Maximal voluntary isometric contraction(MVIC) was measured by the dynamometer. Muscle activity was recorded from the rectus femoris muscle. During the experiment, the subject was seated in the chair. The measured items, median frequency(MDF) and root mean square (RMS), were collected from the surface EMG. All data were analyzed using repeated measures ANOVA. Results: There was significant difference of MVIC between male and female. Endurance time was significant difference by the level of MVIC but no significant in the main effect(sex) and interaction effect. The MDF and fatigue index were significant differences in the interaction effect. The RMS was not significant difference in both of main and interaction effect. The muscle fatigue patterns of female was greater than male after 60% MVIC. Conclusion: This study showed that sex differences of muscle fatigue were started from 60% MVIC.

  • PDF

신경근전기자극 적용양식에 따른 대퇴사두근의 중앙주파수 변화 (Changes in Median Frequency of Quadriceps Muscle According to Application Modes of Neuromuscular Electrical Stimulation)

  • 최수희;오명화;김태열;정진규
    • 대한임상전기생리학회지
    • /
    • 제3권1호
    • /
    • pp.49-59
    • /
    • 2005
  • This study assigns each 8 of 24 normal persons to control group(Group I), strength increase group(Group II) and endurance increase group(Group III) to analyze differences in changes of strength and endurance with surface electromyography and kinetics according to application modes of neuromuscular electrical stimulation(NMES). Group I had not any treatment, group II performed 15 repeated contraction with 60% intensity of maximal voluntary isometric contraction(MVIC) by setting 10-sec on time and 50-sec off time and group III conducted 30 repeated contraction with 30% intensity of MVIC by setting 10-sec on time and 20-sec off time. For neuromuscular electrical stimulation, 2,500 Hz of Russian current, 35 pps of pulse rate and 200 of pulse width. Neuromuscular electrical stimulation was conducted by five times for total 4 weeks. Before and after experimentmotor unit action potential of vastus medialis, rectus femoris and vastus lateralis were measured with sEMG, median frequency(MDF) was analyzed, and thus the following results were obtained. There was significant difference in the period of measuring vastus medialis and rectus femoris in change of MDF and interaction among groups with analysis of surface electromyography before and after neuromuscular electrical stimulation(p<.001) and in particular, there was a remarkable change among groups according to the period of measurement. In conclusion, NMES influenced changes of strength and endurance according to its application modes and in particular, it was found that strength increment application had a significant influence on strength increment in applying short-time NMES.

  • PDF

Effect of Vibratory Stimulation on Recovery of Muscle function from Delayed Onset Muscle Soreness

  • Koh, Hyung-Woo;Kim, Cheol-Yong;Kim, Gye-Yoep;Kim, Kyung-Yoon;Kim, Soo-Geun;Lee, Hong-Gyun
    • 운동영양학회지
    • /
    • 제16권1호
    • /
    • pp.43-50
    • /
    • 2012
  • This study was designed to investigate the effect of vibratory stimulation on recovery of muscle function from delayed onset muscle soreness (DOMS). Volunteers performed 3 set of 70 % maximal voluntary eccentric muscle contraction and induced DOMS. volunteers were allocated to one of three treatment group after DOMS : group I (control), group II (ultrasound), group III (vibration). Maximal Voluntary Isometric Contraction (MVIC), Visual Analog Scale (VAS), Range Of Motion (ROM), Root Mean Square (RMS), Median frequency (MDF), Blood Serum Creatine Kinase (CK), Lactic dehydrogenase (LDH) were recorded at baseline, and 24, 48, 72 hours post-exercise. In MVIC measurement, there was a statistically significant difference in group III compared to group I (p < .05). In VAS measurements, there were a statistically significant difference in group II and III compared to group I (p < .05). In ROM measurement, there was a statistically difference in group II and III compared to group I (p < .05). In Muscle Volume with Ultrasonography measurement, there was no statistically significant difference in any groups (p > .05). In RMS and MDF measurement, there were a statistically significant difference in group II and III compared to group I (p < .05). In Blood samples of CK and LDH measurements, There were no statistically significant difference in any groups (p > .05). From the above result, Vibratory stimulation had a positive effect on recovery of muscle function from delayed onset muscle soreness. Further studies should be undertaken to ascertain the more effectiveness of vibratory stimulation and may be a promising treatment modality.

컴퓨터 작업 후 유지-이완운동과 능동신장이 근피로 회복에 미치는 영향 (The Effects of Hold-Relax and Active Stretching on Recoveries of Muscle Fatigue after Computer Work)

  • 이현옥;허성용
    • PNF and Movement
    • /
    • 제6권2호
    • /
    • pp.11-18
    • /
    • 2008
  • Purpose : The purpose of this study was to identify that the effect of hold-relax and active stretching on recoveries of upper trapezius and sternocleidomastoid muscle fatigue after computer work. Methods : This study was conducted by 30 volunteer at the age of 23~33(resting group=10, hold-relax group=10, active stretching group=10). The muscle fatigue measured by tracing the median frequency(MDF) decrement from power spectrum analyses of EMG signals and the data were analyzed repeated ANOVA. Result : In case of upper trapezius, there was significant difference in group I,II and group II, III. In case of sternocleidomastoid, there was significant difference in group I,II and group I,III. Conclusion : The active stretching was effective for sternocleidomastoid and the hold-relax was effective for upper trapezius and sternocleidomastoid. The hold-relax was effective better than active stretching on recoveries of muscle fatigue.

  • PDF

근 길이에 따른 근 섬유 동원률의 차이 (The Effect of the Muscle Firing Rate on Muscle Length)

  • 송영희;정이정;조상현
    • 한국전문물리치료학회지
    • /
    • 제11권3호
    • /
    • pp.85-90
    • /
    • 2004
  • The purpose of this study was to find the difference in muscle firing rate between each muscle according to the knee angle with the quadriceps femoris which is a representative action muscle of the lower extremity. Seven normal healthy subjects were recruited. The median frequency (MDF) of muscle contraction was recorded from vastus lateralis, vastus medialis, and rectus femoris muscles using the surface EMG, in 5 seconds, during maximal isometric knee extension. The data were analyzed by the two-way repeated ANOVA. The results of the study were as follows: 1) median frequency of muscle contraction was significantly higher at the vastus lateralis, vastus medialis, and rectus femoris in descending order. 2) median frequency of muscle contraction was significantly higher at the $30^{\circ}$, $60^{\circ}$, and $90^{\circ}$ in descending order. Consequently, muscle recruitment at the knee decreases the EMG activity of the lengthened muscle. This study suggests that the change in EMG activity at different muscle lengths resulted in affecting the muscle firing rate during the knee extension.

  • PDF

12주 근력강화훈련 동안 표면근전도 신호의 특성 (Characteristics of Surface Electromyography During Strength Training of 12 weeks)

  • 신화경;조상현;차광석
    • 한국전문물리치료학회지
    • /
    • 제10권1호
    • /
    • pp.109-128
    • /
    • 2003
  • This study tested whether repeated measurement of median frequency (MDF)-related variables could express the muscle power changes during a 12-week DeLome strengthening program, by using consecutive overlapping FFT (Fast Fourier transformation) and integrated EMG (IEMG) from surface EMG data for isometric and isotonic exercise. To evaluate the effect of training, the following were recorded every 3 weeks for the elbow flexors and knee extensors of 5 healthy male volunteers: MVC, lRM, limb circumference, and surface EMG during isometric MVC or isotonic contraction at 10RM load. From the EMG data, IEMG and variables from a regression analysis between MDF and time were obtained. MVC, lRM, IEMG, and initial MDF increased linearly over the training period. The fatigue index and slope of the regression line increased temporarily until the 6th week and decreased thereafter. From these results, there appeared to be enhanced neural recruitment of fast twitch fibers in the first 6 weeks and continued enhancement in the recruitment and hypertrophy of fast twitch fibers, which led to increased fatigue resistance, over the last 6 weeks. Accordingly, the MDF and IEMG analysis technique could demonstrate the effect of the program detected significant changes in both isometric and isotonic contractions. EMG analysis methods can be used to estimate the electrophysiological and histological changes in skeletal muscles during a strengthening program.

  • PDF

근전도 바이오피드백 훈련이 퇴행성 슬관절염 환자의 대퇴사두근 활성에 미치는 효과 (Effect of Quadriceps Activity for Degenerative Arthritis Applied EMG Biofeedback Training)

  • 김용억;김동현
    • 대한임상전기생리학회지
    • /
    • 제6권1호
    • /
    • pp.31-42
    • /
    • 2008
  • This study performed in order to investigate the effect of isometric resistance exercise for vastus medialis oblique muscle with EMG(electromyography) biofeedback training which are applied to the patello-femoral joint of patients with osteoarthritis on the improve of function. The subjects had no neuromuscular disorders, and they were elder patients with osteoarthritis, 20 women. And the experiment was performed in control group, taping with EMG biofeedback training group respectively, and the measurement was carried out before and after the treatment and 4 weeks after the treatment. Motor unit action potential analysis with surface electromyography showed a significant change in RMS(root mean square) amplitude and MDF(median frequency) in vastus medialis oblique muscle(p<0.05). VMO/VL(vastus medialis oblique/vastus lateralis oblique) MDF ratio showed a significant change between groups(p<0.05). Taping with EMG biofeedback training applied to patello-femoral joint of osteoarthritis patients appeared to be effective for muscle function improvement. However, increase of muscular force in vastus medialis oblique muscle appears to have a positive effect on improve of function along with correction effect on patella malalignment. In conclusion, in case of osteoarthritis patients with loss of patello-femoral joint function, it appears to be effective to practice isometric resistance exercise of vastus medialis oblique muscle selective with taping.

  • PDF