• Title/Summary/Keyword: Median Frequency

Search Result 451, Processing Time 0.029 seconds

A Retrospective Study on Canine Epilepsy: Etiological Distribution, Therapeutic Outcome, and Survival Time

  • Park, Seo-Yeon;Jeong, Yoonsoo;Yun, Taesik;Jung, Dong-In;Chang, Dong-Woo;Kang, Ji-Houn;Yang, Mhan-Pyo;Kang, Byeong-Teck
    • Journal of Veterinary Clinics
    • /
    • v.36 no.3
    • /
    • pp.150-154
    • /
    • 2019
  • The purpose of this study was to investigate the etiological distribution, therapeutic outcome, and survival time in canine epilepsy. The medical records of 57 epileptic dogs were reviewed for the evaluation of etiological distribution. Among them, 27 dogs (47%) and 30 dogs (52%) had idiopathic epilepsy (IdE) and structural epilepsy (StE), respectively. Twenty-nine dogs (IdE: 16 dogs, StE: 13 dogs) were evaluated for therapeutic outcome and survival time. The incidence of generalized epileptic seizure (IdE, 56% vs. StE, 44%; P = 0.043) and the median seizure frequency at the time of first presentation (IdE, 2.0/month vs. StE, 13.3/month; P < 0.01) were significantly different between the two groups. Although pre-treatment seizure frequency and duration were not different, the median duration of seizure in the IdE group (0.5 min) was significantly shorter than that in the StE group (3 min) after treatment (P < 0.01). In addition, the median frequency of seizure was relatively lower in the IdE group (0.25/month) compared to the StE group (2.00/month) following antiepileptic therapy (P = 0.053). The median survival time of the IdE group (1.5 years [95% CI, 1.0-2.3 years]) was significantly longer than that of the StE group (0.4 year [95% CI, 0.2-1.3 years]) (P < 0.01). The information on etiological data and intracranial lesions may be useful for predicting treatment response and prognosis in epileptic dogs.

New Definition of the Fibrogram and Its Application to Cotton Blending

  • Jeon, Boong-Soo
    • Fibers and Polymers
    • /
    • v.6 no.4
    • /
    • pp.332-335
    • /
    • 2005
  • The fibrogram theory is newly derived from the superposition principle of the conventional staple diagram, in which the left-hand ends of the fibers have to share a common starting point in order for the fiber length distribution to be measured, and the right-hand ends of the fibers form points. It is shown that the fibrogram is the staple diagram of the fiber sample having different random starting points, as well as the double cumulative distribution function of the frequency length function in the length biased sample. Also, the various means, viz. the numerical mean length, numerical mean length in median, length biased mean length, and length biased mean length in median, and the various upper half means, viz. the numerical upper half mean length, numerical upper half mean length in median, length biased upper half mean length, and length biased upper half mean length in median, are discussed in relation to the cotton blending process.

A Study on the Content of Total Mercury in the Head Hair of Dental Personnel (치과계 종사자의 두발중 총 수은 함량에 관한 연구)

  • 이택승;손동헌
    • YAKHAK HOEJI
    • /
    • v.23 no.1
    • /
    • pp.17-29
    • /
    • 1979
  • The total mercury content in the head hair of 87 dental personnel and 210 Seoul citizens as control was determined. 1) The mean value of mercury content in dentists (8.57ppm) was 3.3 times of Seoul male citizens (2.57ppm) and the median of the former (5.92 ppm) was higher than that of the latter (2.39ppm) by approximately 2.5 times. 2) The mean value of mercury content in dental nurses (5.79ppm) was 2.8 times of Seoul female citizens(2.11ppm) and the median of the former(4.62ppm) was higher than that of the latter (1.86ppm) by approximately 2.5 times. 3) The mean value of mercury content in Seoul citizens was 2.29ppm and the median was 1.98ppm. 4) There was no correlationship between the mercury content in the head hair of dentists and the length of dental surgery experience or the frequency of amalgam fiillings per day. 5) The mercury content of Seoul citizens was higher in the male than in the female. 6) It appears more meaningful to employ median values than mean values when the environmental pollution is considered.

  • PDF

Validity and reproducibility of a food frequency questionnaire for breast cancer survivors in Korea

  • Sang-Eun, Moon;Woo-kyoung, Shin;Sihan, Song;Dahye, Koh;Jeong Sun, Ahn;Youngbum, Yoo;Minji, Kang;Jung Eun, Lee
    • Nutrition Research and Practice
    • /
    • v.16 no.6
    • /
    • pp.789-800
    • /
    • 2022
  • BACKGROUND/OBJECTIVES: The aim of this study was to examine the validity and reproducibility of a food frequency questionnaire (FFQ) developed in Korea for breast cancer survivors. SUBJECTS/METHODS: Ninety-nine breast cancer survivors who completed an FFQ twice and three 3-day dietary records (DRs) between 2016-2017 were included. Energy and 14 nutrient intakes were calculated from FFQs and DRs. To determine the validity of the FFQ, energy-adjusted de-attenuated Pearson correlations between two FFQ assessments and the average of the three 3-day DRs were calculated, and to determine reproducibility, energy-adjusted Pearson correlations and degrees of agreement were calculated between the first and second FFQ assessments. RESULTS: Correlation coefficients of validity ranged from 0.29 (protein) to 0.47 (fat) (median value = 0.36) for the FFQ assessment and from 0.20 (riboflavin) to 0.53 (calcium) (median value = 0.37) for the second. Correlation coefficients of reproducibility ranged from 0.22 (sodium) to 0.62 (carbohydrate) (median value = 0.36). Regarding FFQ reproducibilities, percentage classifications of exact agreements for energy-adjusted nutrients ranged from 27.3% (sodium) and 45.5% (fat). A median 76.8% of participants were classified into the same or adjacent quartiles, while a median of 5.6% of participants were classified in extreme quartiles. Bland-Atman plots for the majority of data points of three macronutrients, calcium and vitamins A and C fell within limits of agreement. CONCLUSIONS: These results indicated that the newly developed FFQ for Korean breast cancer survivors has acceptable validity and reproducibility as compared with three 3-day DRs collected over a one-year period.

Quantitative Analysis of Myofascial Pain Syndrome in Trapezius Muscle Using Pressure Algometer and Surface Electromyography

  • Kim, Shin-Hye;Ko, Yu-Min;Park, Ji-Won;Youn, Jong-In
    • The Journal of Korean Physical Therapy
    • /
    • v.33 no.5
    • /
    • pp.258-263
    • /
    • 2021
  • Purpose: Myofascial syndrome is a chronic muscle pain caused by repetitive motions with stress-related muscle tension. This study aimed to investigate the validity and reliability of the evidence for diagnosing myofascial pain syndrome in trapezius muscle using a pressure algometer and surface electromyography. Methods: The experiments were performed using a total of 10 subjects, and the target locations were determined by means of a pressure algometer in the right upper trapezius muscle. The part with the lowest pain value as the trigger point and the part with the highest pain value as the non-pain trigger point were selected for measuring the locations. The median frequency and average frequency were measured in those locations with electromyography. To check the muscle fatigue, the upper trapezius muscle was moved up and down for 2 seconds at 5-second intervals in 30 seconds. The measured values were evaluated using the independent paired t-test and MannWhitney U-test. Results: The median frequency at the non-trigger point (13.7) was significantly higher than that at the trigger point (7.3). Furthermore, the mean frequency (14.7) at the non-trigger point was significantly higher than that at the trigger point (6.3). Conclusion: The results showed the correlations between the trigger points of the muscle pain and frequency analysis of surface electromyography. Thus, this study may be possible to use as a diagnostic tool for myofascial pain syndrome.

Effects of Frequency Type on Muscle Function of the Thigh during Electrical Muscle Stimulation (전기근육자극 시 주파수 차이가 대퇴 근육 기능에 미치는 영향)

  • Woen-Sik Chae;Jae-Hu Jung
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.1
    • /
    • pp.17-24
    • /
    • 2023
  • Objective: The purpose of this study was to investigate the effects of different frequency on of knee extensors muscle function during electrical muscle stimulation (EMS). Method: In this research, 40 subjects who have no musculoskeletal disorder, and less than a year workout experience were recruited in order to analyze effects of EMS with different stimulus frequency. Forty subjects were randomly divided into four groups of ten subjects in each group. A EMS training program with different frequencies (without EMS [WE], EMS with frequency 30 Hz [E30], EMS with frequency 60 Hz [E60], EMS with frequency 90 Hz [E90]) was assigned to each group. Throughout eight weeks of training, test subjects were simultaneously carried out knee extension exercises such as squat, leg extension, and leg-press while using EMS with different frequency (20 min, pulse width 250 ㎲, on-off ratio 1:1). Isokinetic knee extension strength, muscle activity of the rectus femoris (RF), the vastus medialis (VM), and the vastus lateralis (VL), and the median frequency of the RF, the VM, and the VL were collected and compared between pre and post training in order to find effects of applying EMS with different frequencies. For each dependent variable, a one-way ANOVA was to determine whether there were significant differences among four different conditions (p<.05). When a significant difference was found, post hoc analyses were performed using the contrast procedure. Results: When compared to WE and E90, E30 causes significant increase in isokinetic knee extension strength. No significant differences were found in EMG values across different EMS conditions. However, the median frequency of the VM in E30 was significantly increased than the corresponding value for WE. Conclusion: The results of this study showed that EMS training with 30 Hz frequency had positive effect on knee extensor. Based of the findings of the present study, EMS training with lower frequency may help the performer to focus on developing strength in knee extensor muscles.

Correlation between Muscular Fatigue and EMG Activity during the Prolonged Casual Computer Work

  • Cho, Won-Hak;Lee, Woo-Yong;Choi, Hyeon-Ki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.3
    • /
    • pp.224-229
    • /
    • 2009
  • An experimental study was conducted to investigate the effects of turtle neck syndrome, so called, on muscular fatigue and muscle activity. Six subjects (males) participated and performed the prolonged casual computer work in the study. EMG signals from six muscles of the dominant neck-back region were acquired and recorded for 10 seconds at the beginning and the end of three hours computer work. EMG was recorded from six muscles by using a computerized data recording and analysis system. Power spectrum function of EMG was calculated off-line by means of a signal processing software package. Power spectrum functions were smoothed with a moving average filter of 21 points and normalized with respect to the maximal value achieved during the trials. Muscle activity and median frequencies of Sternocleidomastoid(SCM) in turtle neck posture was approximately 51%, which were less than those in normal neck posture. SCM also showed the biggest decrease in median frequency. Results will provide the insight into the neck-back injury mechanism of turtle neck patients. Furthermore, they will be helpful in developing rehabilitation programs for restoring patients' neck-back functions.

Median Sternotomy for Bilateral Resection or Plication of Bullae (정중 흉골절개술을 이용한 동시적 양측 폐기포 절개술)

  • 박희철
    • Journal of Chest Surgery
    • /
    • v.24 no.2
    • /
    • pp.182-189
    • /
    • 1991
  • Fourteen patients underwent surgical resection of bullae between February, 1987 and June, 1990 via median sternotomy. Twelve patients had spontaneous pneumothorax with previous history of pneumothorax on the contralateral side or visible bullae on chest X-ray films. Two patients had bullous emphysema. The duration of operation and admission, frequency and amount of analgesic administered for pain control, pulmonary function test [FEV1, FVC, MVV] and the amount of bleedings were compared with six cases of staged unilateral thoracotomy. The results were as follows: 1. All patients were male. 2. Mean follow up period was 13.5 month and no recurrence of pneumothorax are noted after the operation. 3. Median sternotomy showed shortened admission days than thoracotomy. [12.4$\pm$2.7, 15.6$\pm$3.1 days] 4. Significantly shortened anesthetic time in median sternotomy than thoracotomy [121$\pm$21, 184$\pm$33 minutes] 5. Median sternotomy required less injection of analgesics than thoracotomy. [6.5$\pm$2.7, 13.5$\pm$3.1 ampules] 6. Bleeding amount and PFT showed no differences. 7. Complications were prolonged air leakage for more than 7 days [2 patients], transient elevation of SGOT and SGPT[2 patients], and wound infection[1 patient]

  • PDF

Dyssynergic Defecation in Chronically Constipated Children in Korea

  • Sun Hwan Bae
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.26 no.2
    • /
    • pp.127-133
    • /
    • 2023
  • Purpose: Dyssynergic defecation (DSD) is one of the important causes of chronic constipation in children. We aimed to analyze the clinical features, diagnostic test results, and treatments for DSD in children. Methods: Children diagnosed with DSD using fluoroscopic defecography were enrolled in this study. Clinical data, including the results of colon transit time (CTT) test and biofeedback (BF) therapy, were collected from medical records retrospectively. Results: Nineteen children were enrolled. The median age was 9 years (6-18 years), the median frequency of bowel movement was 1/7 days (1-10 days), the median duration of constipation was 7.0 years (2-18 years), the median age of onset of constipation was 2.5 years (1-11 years). In the CTT test, outlet obstruction type was noted in 10/18 (55.6%), slow transit type in 5/18 (27.8%), and normal transit in 1/18 (5.6%). The median CTT was 52 hours (40-142 hours). Initial medical therapy was performed with the polyethylene glycol 4000, and the response was good in 9/19 (47.4%), fair in 9/19 (47.4%), and poor in 1/19 (5.0%). BF was performed in 8/19, with good results in 6/8 (75.0%) children and failure in 2/8 (25.0%) children. After long-term medical therapy (11/19), 3/5 showed good response with medication alone, 6/8 showed good response with BF and medication combined. Conclusion: DSD should be considered as a cause of chronic constipation in children, especially in those with abnormal CTT test results. BF combined with medical therapy is effective even with age-limited cooperation.

The Effect of Joint Space Pumping Treatment in Patients with Reducible Disc Displacement Accompanied by TMJ Sound and Pain (악관절잡음 및 동통을 동반한 정복성 관절원판 변위환자에 대한 관절강 Pumping 효과)

  • Kim, Hyeon-Cheol;Choi, Jong-Hoon;Park, Hye-Suk;Kim, Chong-Youl
    • Journal of Oral Medicine and Pain
    • /
    • v.24 no.1
    • /
    • pp.9-24
    • /
    • 1999
  • Pumping into the upper joint cavity of the TMJ was done on patients who had reducible disc displacement with pain. This article discusses the change in TMJ sounds before and after the Pumping treatment. 20subjects(mean age of $32.1{\pm}10.2yr$)were selected among those who visited the department of Oral Medicine of Yonsei University for the treatment of craniomandibular dysfunctions. Through a thorough history taking, clinical exam and X-ray taking these subjects were diagnosed as reducible disc displacement patients, and they were subdivided into two groups as acute and chronic according to the time the TMJ sound was made. Sonopak was used to measure the TMJ sound before, right after and one-week after the Pumping treatment. VAS was used to measure the degree of subjective TMJ complaints(sounds and pain) before and one-week after the Pumping treatment. Vibration related items included total integral, high integral, low integral, ratio of high integral to low integral, peak amplitude, peak frequency and median frquency. 1. It was not statistically significant between the acute and chronic groups before the treatment. However, total integral, high integral, low integral, peak amplitude, peak frequency, median frequency showed to be greater in the chronic group. 2. In all the subjects, just after the Pumping treatment was done, total integral, high and low integral, peak amplitude and peak frequency significantly decreased (p<0.05). Even after one week, low integral, peak frequency and median frequency significantly decreased (p<0,05), and the TMJ sound diminished accordingly. 3. Comparing the two groups(before and right after the Pumping treatment), there was the following difference ; in the acute group, high integral, high amplitude, high frequency and median frequency significantly decreased(p<0.05). In the chronic group, total integral, high integral, low integral, ratio, peak amplitude and peak frequency significantly decreased(p<0,05). It was not statistically significant between the acute and chronic group. 4. Comparing the two groups(right after and one week after the Pumping treatment), there was the following difference : in the acute group, high integral, high amplitude, high frequency and median frequency significantly decreased(p<0.05), In the chronic group, low integral significantly decreased(p<0.05). However, although it was not statistically significant, after one week, there was an increase in total integral, ratio, peak amplitude and peak frequency compared to right after the treatment group. 5. In the VAS of before and one week after the Pumping treatment of the TMJ pain and sound, the TMJ pain significantly decreased(p<0.05) in both the acute and chronic group. However, it was not statistically significant between the two groups. There was a statistically significant decrease(p<0.05) in the TMJ sound in the acute group after one week of Pumping treatment, but no change was notable in the chronic group and it was not statistically significant between the two groups. From the above results, we can conclude that Pumping into the upper joint cavity of patients having reducible disc displacement is effective in reducing clicking and pain. Therefore, it can be applied in diverse clinical fields.

  • PDF