• Title/Summary/Keyword: Media Pole

Search Result 27, Processing Time 0.026 seconds

3-D Inversion of 3-D Synthetic DC Resistivity Data for Vein-type Ore Deposits (국내 맥상광체조사를 위한 3차원 전기비저항 모델링자료의 3차원 역산 해석)

  • Lee, Ho-Yong;Jung, Hyun-Key;Jeong, Woo-Don;Kwak, Na-Eun;Lee, Hyo-Sun;Min, Dong-Joo
    • Journal of the Korean earth science society
    • /
    • v.30 no.6
    • /
    • pp.699-708
    • /
    • 2009
  • Recently as the interest in the development of domestic ore deposits has increased, we can easily find some studies on exploration geophysics-based ore-deposit survey in literature. Based on the fact that mineralized zone are generally more conductive than surrounding media, electrical resistivity survey among several geophysical surveys has been applied to investigate metallic ore deposits. Most of them are grounded on 2-D survey. However, 2-D inversion may lead to some misinterpretation for 3-D geological structures. In this study, we investigate the feasibility of the 3-D electrical resistivity survey to 3-D vein-type ore deposits. We first simulate 2-D dipole-dipole survey data for survey lines normal to the strike and 3-D pole-pole survey data, and then perform 3-D inversion. For 3-D ore-body structures, we assume a width-varying dyke, a wedge-shaped, and a fault model. The 3-D inversion results are compared to 2-D inversion results. By comparing 3-D inversion results for 2-D dipole-dipole survey data to 3-D inversion results for 3-D pole-pole survey data, we could note that the 2-D dipole-dipole survey data yield better inversion results than the 3-D pole-pole data, which is due to the main characteristic of the pole-pole array. From these results, we are convinced that if we have certain information on the direction of the strike, it would be desirable to apply 2-D dipole-diple survey for the survey lines normal to the strike. However, in most cases, we do not have any information on the direction of the strike, because we already developed the ore deposit with the outcrops and the remaining ore deposits are buried under the surface. In that case, performing 3-D pole-pole electrical resistivity survey would be a reasonable choice to obtain more accurate interpretation on ore body structure in spite of low resolution of pole-pole array.

Effect of Magnetic Strength of Three-dimensionally Arranged Magnetic Barrel Machine on Polishing Characteristics

  • Zhang, Yu;Yoshioka, Masato;Hira, Shin-ichiro;Wang, Zhuqing
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.2
    • /
    • pp.34-38
    • /
    • 2008
  • Commercially available magnetic barrel machines equipped with permanent magnets have certain limitations: work can only be finished effectively in limited areas of the container because permanent magnets are arranged two-dimensionally on the magnet disk. We overcame this problem by developing a new magnetic barrel machine equipped with a three-dimensional magnet arrangement. The effectiveness of the new machine has already been reported; this study improved the machine's polishing ability by changing the polarity of magnets on a magnet block. Polishing experiments confirmed the most effective arrangement of magnets on the magnet block. An alternating arrangement of north and south poles produced far superior polishing characteristics than a uniform arrangement of the same pole facing outward. Alternating polarity probably causes increased quantities of barrel media to work together. Finally, we introduced stronger permanent magnets to the magnet block, and found that the increased magnetic field also improved polishing ability.

Design of HDD Write Head for 100Gbit/$in^2$ Densities (100Gbit/$in^2$ 기록 밀도를 위한 HDD Write Head의 설계)

  • Won, Hyuk;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.626-628
    • /
    • 2001
  • 고 기록 밀도의 HDD를 위해서는 HDD Media의 선 기록 밀도와 트랙 밀도를 높여야 한다. 선기록 밀도를 높이기 위해서는 HDD Write Head의 Field Gradient가 커야하고, 트랙 밀도를 높이기 위해서는 Write Head의 Aspect Ratio가 작아져야 한다. 본 연구에서는 3차원 유한 요소법을 이용하여 Write Head의 재료의 자기적 성질과 형상에 따른 고 기록 밀도용 Pole Tip Write Head를 설계하였다.

  • PDF

Effect of soft underlayer on read/write in double layered perpendicular recording media (이중층 수직기록 매체에서 read/write 특성에 미치는 soft underlayer의 효과)

  • 이성철;탁영욱;이택동;이경진
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.180-181
    • /
    • 2002
  • 수직기록매체에서 기록 밀도가 증가하기 위해서는 bit의 크기를 줄여야 하고, 이를 위해서는 writing head의 width와 thickness를 줄여야 한다. 그러나 head의 크기가 줄어들면 기록층의 자화를 반전시키기에 충분한 write field를 얻지 못한다. 이를 극복하기 위해 head의 tip부분을 trimming을 하여 작은 pole tip 크기를 가지면서도 큰 write field를 얻고, 여분의 magnetic field를 얻기 위해 soft underlayer를 도입하는 이중층 수직기록 매체가 제안되고 있다. (중략)

  • PDF

A development on remote monitoring technology of distribution transformer using CDMA wireless data communication (CDMA무선 데이터통신을 이용한 배전용변압기 원격감시 기술개발)

  • Park, Chang-Ho;Rho, Whang-Rae;Kim, Jun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.483-485
    • /
    • 2000
  • This paper presents the operation technology and the remote monitoring system of distribution pole transformer. Especially, this system uses CDMA wireless data communication network as media which is serviced on a national scale. It has four major components such as sensor for measuring the secondary voltage and currents of distribution transformer, CDMA wireless modem for data modulating/demodulating, communication media for sending/receiving of data, and PC server for monitoring the results of sensing or computing information. This paper also describes the configuration of each component's functions with its development process.

  • PDF

Design of Charging Platform for an Electric Vehicle using Electric Pole to support Location-Based Services (LBS 서비스를 제공하는 전주를 이용한 전기차 충전 플랫폼의 설계 제안)

  • Cha, ByungRae;Choi, GeunYoung;Kim, NamHo;Lee, SeongHo;Park, Sun;Shin, Byeong-Chun;Kim, JongWon
    • Smart Media Journal
    • /
    • v.9 no.1
    • /
    • pp.67-74
    • /
    • 2020
  • As the demand of electric vehicles has been increased recently, their related industries are developing. In particular, the market of electric vehicles charging infrastructure is expanding rapidly and users have much demand in convenience of electric vehicles charging site. Because an charging site using electric pole of KEPCO can make use of that installed nearby public parking lots, there are many commercial construction and convenient facilities near around it. In this situation, users can do shopping or their personal business during charging. In this paper, we proposed the design of charging platform for electric vehicles to support LBS for users to do shopping or personal business conveniently.

Development or 170KV 50KA GCB with Common three-pole operating mechanism (3상일괄조작형 170KV 50KA GCB의 개발)

  • Song, W.P.;kim, H.J.;Sung, B.J.;Lee, C.H.;Noh, C.W.;Kwon, W.H.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.626-628
    • /
    • 1992
  • GCB(Gas Circuit Breaker) and GIS(Gas Insulated Switchgear) using $SF_6$ are worldwidely applied over 72.5KV classes. It Is known that $SF_6$ gas has the most superior characteristics among the extingushing and insulating media. Our Company has produced GCB and GIS from early 1980's and at present, we are producing 362KV 40KA class which is the highest voltage in our country. According to change KEPCO's standards (ESB standards), our company has redeveloped and tested for all productions type from 1989. During redeveloping, we largely contribute raise reliability of power system, through all the more improvement for performance and quality of manufactures. One of them, we developed 170KV 50KA GCB with common three-pole operating mechanism and sucessfully completed test of KERI under KEPCO presence, at first in our country. Thus, we announce the outline of it.

  • PDF

Fiber-To-The-Pole(FTTP)-A NOVEL ACCESS NETWORK SOLUTION USING WDM-PON (WDM-PON기반 FTTP 광가입자망 시스템)

  • Kim, Bo-Gyeom;Park, Tae-Dong;Choe, Yeong-Bok;O, Ho-Seok;Lee, Won-Hyeong
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.107-108
    • /
    • 2006
  • In order to meet the customers'emerging demands for more bandwidth and diverse IP multimedia applications including high definition(HD) video streaming service, KT presents innovative FTTP solution using WDM-PON system. FTTP comprises an OLT inside the central office, a fiber optic distribution network including a passive remote node in the outside plant, and ONU installed on the pole or wall of customers premise. The passive remote node is located in a manhole near the subscribers and does not require any electrical power supply. And finally, UTP cable is connected from ONU to subscribers'IP appliances like PC or HGW or IP-STB. KT finished its FTTP trial service in 2004 and commercial deployment has begun since 2005. With this FTTP solution, each subscriber can enjoy high-speed internet service with speeds of up to symmetric 100 Mbit/s and various IP media applications including HD quality IP video streaming service and high quality video phone service.

  • PDF

Analysis of Reproducing Characteristics in Perpendicular Magnetic Recording System Using Preisach Model (Preisach 모델을 이용한 수직자기기록장치의 재생특성 해석)

  • 박관수;이향범;이택동;장평우
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.1
    • /
    • pp.50-55
    • /
    • 1992
  • Numerical method for analyzing the reading process in magnetic recording system is described. Hysteresis characteristics must be included in numerical analysis not only recording process but also reading process because of hysteretic behavior of recording media. Algorithm which is consisted of finite clement method for numerical analysis and Preisach model considered to be more appropriate method than Stoner-Wohlfarth model with spin curling mode for describing hysteresis characteristics is constructed. Equations to calculate waveform of reproduced voltage is proposed. Then, this is applied to perpendicular magnetic recording systems with pole type head and double layer media. Waveform of magnetic flux density and reproduced voltage induced in head coil is obtained. If the recording current increase in recording process, magnitude of reproduced voltage in reproducing process saturates. From this saturation curve, value of current which produce maximum voltage can be obtained.

  • PDF