• Title/Summary/Keyword: Mechanical ventilators

Search Result 53, Processing Time 0.026 seconds

Comparison of Vital Sign and Respiratory Functions According to the Points of Time to Nebulize Bronchodilator to Operated Adult Patients through Mechanical Ventilator (인공호흡기를 통하여 기관지 확장제를 분무한 시점에 따른 심장수술환자의 활력징후와 폐기능의 비교)

  • Kang, Jee Young;Yoo, Yang Sook;Seong, So Young;Seo, Ji Won;Koo, Seul A;Park, Kyoung Won;Choi, Eun Ju
    • Journal of Korean Clinical Nursing Research
    • /
    • v.14 no.3
    • /
    • pp.73-85
    • /
    • 2008
  • Purpose: To examine effects of application of bronchodilators after endotracheal suction on peak air way pressure (PAP), lung compliance (Cdyn), oxygen saturation ($SpO_2$), heart rate (HR), blood pressure (BP), and respiration rate (RR) in cardiac surgery patients. Method: Data were collected from October 2007 to March 2008. Participants were patients who were treated with bronchodilators through mechanical ventilators in the SICU. At each suctioning, bronchodilators were applied immediately, and at 5, 10, and 15 minutes after suctioning. Besides PAP, Cdyn, $SpO_2$, HR, BP, RR, data on the frequency of side effects were also collected at 15, 30, 60 minutes after nebulization. Data were analyzed using the SAS program. Results: For application of bronchodilator right after suctioning and after, 5, 10 and 15 minutes, PAP and Cdyn did not show any significant differences although PAP was persistently decreased for 15 to 30 minutes and Cdyn increased at 15 minutes and decreased gradually after nebulization. Besides $SpO_2$, HR, BP, and RR, frequency of side effects did not show any significant difference. Conclusion: Bronchodilators can be applied at any time. However, the positive effects of bronchodilation right after suctioning on PAP and Cdyn, as also shown in previous reports, indicate it is a more efficient clinical process to maintain an adequate airway.

  • PDF

Evaluation of the Performance and the Energy Consumption Characteristics of Heat Recovery Ventilators in Apartments (공동주택 열교환기의 성능 및 에너지소비 특성 평가)

  • Kim Sang-Min;Park Byung-Yoon;Sohn Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.496-504
    • /
    • 2005
  • Heat recovery ventilators (HRV) are developed in order to satisfy both energy conservation and the improvement of indoor air quality as an alternative for current natural ventilation systems and local mechanical ventilation systems in kitchens and bathrooms. However, the performance of HRV system and the consequent effect on heating and cooling energy saving have not been sufficiently validated quantitatively in case of the application of HRVs in real residences. In this study, field measurement and computer simulation were conducted in both summer and winter period to assess the performance and validate energy conservation effect of HRVs. Under the Korea weather condition, average total heat recovery efficiency was $27\%$ in summer and $46\%$ in winter. According to the field measurement, HRV system can save the energy by $10\%$ in summer and 15$\%$ in winter. Furthermore, according to the simulation assessment, HRV system can save the energy by $17\%$ in summer and $17\%$ in winter.

Early Mobilization and Rehabilitation of Critically-Ill Patients

  • Hye Min Ji;Yu Hui Won
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.2
    • /
    • pp.115-122
    • /
    • 2024
  • Post-intensive care unit (ICU) syndrome may occur after ICU treatment and includes ICU-acquired weakness (ICU-AW), cognitive decline, and mental problems. ICU-AW is muscle weakness in patients treated in the ICU and is affected by the period of mechanical ventilation. Diaphragmatic weakness may also occur because of respiratory muscle unloading using mechanical ventilators. ICU-AW is an independent predictor of mortality and is associated with longer duration of mechanical ventilation and hospital stay. Diaphragm weakness is also associated with poor outcomes. Therefore, pulmonary rehabilitation with early mobilization and respiratory muscle training is necessary in the ICU after appropriate patient screening and evaluation and can improve ICU-related muscle weakness and functional deterioration.

A Study on The Performance of Ventilation and Maintaining Thermal Environment for a Combined Type Diffuser (급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구)

  • Lim, Seok-Young;Chang, Hyun-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.232-241
    • /
    • 2016
  • Installing a ventilator for an apartment house composed of over 100 dwelling units was mandated in 2006 to improve indoor air quality. In the case of mechanical ventilators, the air change rate is kept stable, however 68% of dwellers do not operate their ventilator because of an increased electrical bill and noise. In the case of natural ventilators, the former problems are settled, but there are concerns about cold draught and an increase of heating/cooling cost. Authors are developing a heat recovery type natural ventilator which is a natural ventilator equipped with total heat recovery element, and it is expected that those problems of mechanical ventilator and natural ventilator are resolved by this. The combined type diffuser of this study is an under developed fit to the heat recovery type natural ventilator above. There are no standards to evaluate the performance for this type of diffuser. Due to this issue this study investigated the performance of the ventilation and maintained a thermal environment for the combined type diffuser by comparing it with existing diffusers. The results revealed that the performances of the combined type of diffusers showed different features from the existing ones, and was estimated to be high enough in the performances above.

A Study of The Related Factors to Successful Weaning from Mechanical Ventilation in leu Patients (인공호흡기 치료환자의 이탈(weaning) 성공 관련 요인에 대한 연구)

  • Kim, Eun-Sung;Choi, S-Mi
    • Journal of Korean Biological Nursing Science
    • /
    • v.9 no.1
    • /
    • pp.71-84
    • /
    • 2007
  • Purpose : The Purpose of this study was to identify the physiological, psychological factors to successful weaning of mechanical ventilation in ICU patients. Method: Data was collected by interview with the use of questionnaires from 70 ICU patients, who were mechanically ventilated more than 3days at Y university medical center. Data was analyzed with descriptive statics, t-test, and $x^2$ test, and Pearson Coefficient Correlation using SPSS WIN 12.0 program. Result: ICU patients with mechanical ventilator during weaning period reported high levels of anxiety, moderate levels of stress, and fatigue. The physiological, psychological factors influencing ventilator weaning success were RSBI(p=0.007), stress(p=0.009), anxiety(p=0.020), depression(p=0.040), fatigue(p=0.001), and dyspnea(p=0.010). The RSBI factor was shown to have positive correlations with ventilator care periods, $PaCO_2$, and fatigue. Dyspnea was also positively correlated with stress, anxiety, depression, and fatigue. Conclusion: This study suggests that RSBI, stress, anxiety, depression, fatigue, and dyspnea are significant factors to successful weaning from mechanical ventilation.

  • PDF

User experience of MV2000-MT (SU:M2)® as a Mechanical Ventilator: A Comparative Clinical Study on Usability, Safety, and Medical Staff Satisfaction

  • Jeon, Soeun;Kim, Hae Kyu;Lee, Dowon;Kim, Hyae Jin;Park, Eun Ji
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.260-267
    • /
    • 2019
  • In the present study, we aimed to demonstrate that MV2000-MT(SU:M2)® (MV, MEK-ICS, Paju, Korea), a domestic ventilator, is not inferior in terms of usability, safety, and medical staff satisfaction as compared to Hamilton G5 (G5, Hamilton Medical AG, Rhäzuns, Switzerland). A total of 39 patients who applied MV (group M) or G5 (group H) were included in the study sample. Usability was evaluated by the following factors: the number of alarm errors, replacement requirement of breathing circuit, replacement requirement of a right-angle connector, and ease of ventilator weaning. For safety evaluation, the number of ventilator replacements due to malfunction of the ventilator was evaluated. Items for medical staff satisfaction survey were as follows: the number of MV and G5 uses, hardware, and software assessment. In the usability evaluation, the replacement requirement of the right-angle connector was lower in Group M than in Group H (mean ± standard deviation, Group M: 7.39 ± 6.72, Group H: 14.19 ± 10.24, p = 0.021); however, the evaluations of other parts were not significantly different between the two groups. The number of ventilator replacements due to a malfunction of the ventilator did not differ between two groups. The number of MV and G5 uses was 3.0 [3.0-4.0] and 10.0 [5.0-10.0] (median [interquartile range], p < 0.001). Overall, the mean medical staff satisfaction score of Hamilton G5 was higher than that of MV2000-MT(SU:M2)®. The usability of MV is comparable to that of G5. However, medical staff satisfaction with Hamilton G5 was higher than that with MV2000-MT(SU:M2)®, and this difference could be due to the difference in the number of uses. In order to improve the penetration rate of the domestic mechanical ventilator, it is necessary to find ways to increase familiarity of medical staff with domestic mechanical ventilators.

A Study on the Dew Condensation According to the Operational Conditions of a Heat-Recovery Ventilator (전열교환 환기시스템의 운전 상태에 따른 결로 발생에 관한 연구)

  • Jeon, Byung-Heon;Kim, Jong-Won;Lee, Seung-Kap;Lee, Young-Ju;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.10
    • /
    • pp.529-533
    • /
    • 2013
  • Heat-recovery ventilators are being adopted in most newly built apartment houses for energy reduction and indoor environment improvement. In winter, however, the dew condensation resulting from the difference between the indoor and outdoor temperatures may reduce the ventilator's performance and threaten the health of indoor residents. This study analyzes the occurrence of dew condensation according to the ventilator's operational conditions and the changes of temperature and products. The experimental results show that condensations is formed at $26^{\circ}C$ and 60%R.H, which is an unfavorable climatic condition, and when the damper is not closed tightly. Therefore it is important to ensure damper performance to prevent back flow.

A study on the acoustic performance evaluation of heat recovery ventilator with a sound absorbing duct (흡음덕트 부착 열회수형 환기장치의 음향성능 평가에 관한 연구)

  • Bae, Myung-Whan;Song, Jun-Young;Park, Hui-Seong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.468-475
    • /
    • 2016
  • The purpose of this study is to investigate the acoustic problems of the conventional heat recovery ventilator and to suggest the methods of noise reduction from a heat recovery ventilator according to the installed location. The noise level, in this study, was measured and discussed as the parameters of size, wind volume and sound absorbing duct length for a heat recovery ventilator based on domestic and international related standards. It is found, as a result, that almost all of noise levels from the small and medium heat recovery ventilators without the sound absorbing duct in the anechoic chamber were higher than the noise standard value of 50 dB(A) regardless of the wind volume, and the noise levels went down when a sound absorbing duct was installed. In addition, the sound pressure level relative to frequency bands according to the length of sound absorbing duct was generally decreased, as the length of sound absorbing duct in the small and medium heat recovery ventilators was big, and the sound pressure level was generally increased, as the wind volume was great.

Mechanical Ventilation of the Children (소아의 기계적 환기요법)

  • Park, June Dong
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.12
    • /
    • pp.1310-1316
    • /
    • 2005
  • Mechanical ventilation in children has some differences compared to in neonates or in adults. The indication of mechanical ventilation can be classified into two groups, hypercapnic respiratory failure and hypoxemic respiratory failure. The strategies of mechanical ventilation should be different in these two groups. In hypercapnic respiratory failure, volume target ventilation with constant flow is favorable and pressure target ventilation with constant pressure is preferred in hypoxemic respiratory failure. For oxygenation, fraction of inspired oxygen($FiO_2$) and mean airway pressure(MAP) can be adjusted. MAP is more important than FiO2. Positive end expiratory pressure(PEEP) is the most potent determinant of MAP. The optimal relationship of $FiO_2$ and PEEP is PEEP≒$FiO_2{\times}20$. For ventilation, minute volume of ventilation(MV) product of tidal volume(TV) and ventilation frequency is the most important factor. TV has an maximum value up to 15 mL/kg to avoid the volutrauma, so ventilation frequency is more important. The time constant(TC) in children is usually 0.15-0.2. Adequate inspiratory time is 3TC, and expiratory time should be more than 5TC. In some severe respiratory failure, to get 8TC for one cycle is impossible because of higher frequency. In such case, permissive hypercapnia can be considered. The strategy of mechanical ventilation should be adjusted gradually even in the same patient according to the status of the patient. Mechanical ventilators and ventilation modes are progressing with advances in engineering. But the most important thing in mechanical ventilation is profound understanding about the basic pulmonary mechanics and classic ventilation modes.

Flow Analysis of Cyclone-Cartridge Filter Gausing Collector (사이클론-카트리지필터 일체형 가우징 집진기의 유동해석)

  • Jang, Sung-Cheol;Jung, Dae-Young;Cho, Jung-Sick
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.3
    • /
    • pp.133-139
    • /
    • 2018
  • Precipitator is the most widespread device used to separate dust particles from the exhaust gas. In the shipyard, welding umbrellas, spark protection covers, and ventilators are not purchased and used for the work place to capture the flames and high temperature metal dust generated during the gardening process. In particular, a thorough analysis of design factors, such as capture rate, collection capacity calculation, filter speed, and materials selection, is required since spatial constraints are followed by structures, etc. In this study, conceived to address problems such as this cyclone and filtration filter system that combines all-in-one gausing collector prototype. Assessed through interpretation through the validity of the design and reliability.