• Title/Summary/Keyword: Mechanical transmission

Search Result 1,605, Processing Time 0.032 seconds

A review of the transmission tower-line system performance under typhoon in wind tunnel test

  • Li, Xianying;Yao, Yu;Wu, Hongtao;Zhao, Biao;Chen, Bin;Yi, Tao
    • Wind and Structures
    • /
    • v.29 no.2
    • /
    • pp.87-98
    • /
    • 2019
  • As a regenerated turbulent wind field process, wind tunnel test has proven to be a promising approach for investigating the transmission tower-line system (TTLS) performance in view of experimental scaled models design, simulation techniques of wind field, and wind induced responses subjected to typhoon. However, the challenges still remain in using various wind tunnels to regenerate turbulent wind field with considerable progress having been made in recent years. This review paper provides an overview of the state-of-the-art of the wind tunnel based on active or passive controlled simulation techniques. Specific attention and critical assessment have been given to: (a) the design of experimental scaled models, (b) the simulation techniques of wind field, and (c) the responses of TTLS subjected to typhoon in wind tunnel. This review concludes with the research challenges and recommendations for future research direction.

Evaluation Method of the Transmission Loss for Railway Vehicle Structures. (철도차량 구조물의 TL 시험 평가 기법)

  • 김운경;김정태
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.155-161
    • /
    • 2001
  • In order to evaluate the sound transmission loss of a structure, a large reverberation room described by ISO is generally used. ISO test method is however for architectural structures, which is not properly implemented for small mechanical structures, such as rolling stocks. In this paper, evaluation procedure for railway vehicle structures has been proposed.

  • PDF

Modeling of a Pneumatic Cylinder Position Control system Considering Transfer Characteristics of a Transmission Line (관로의 전달 특성을 고려한 공기압 실린더 위치 제어계의 모델링)

  • Jang, Ji-Seong;Kang, Bo-Sik;Ji, Sang-Won
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.731-736
    • /
    • 2004
  • In this study, a linearized model of pneumatic cylinder position control system including transmission line is proposed. The transmission line using compressible fluid has a nonlinear transfer characteristics because that the frequency response of it is changed by the flowing state of the fluid. But, when the pressure difference between both sides of transmission line is low, the effect of resonance characteristics of it under high frequency range can be neglected because of the friction force and low pass characteristics of the position control system. Therefore, the transmission line can be modeled by second order transfer function and the natural frequency, damping ratio and gain are changed by the diameter and length of it. The effectiveness of the proposed model is proved by comparison of simulation results using proposed model with experimental results and simulation results using conventional model.

  • PDF

A Study on Transmission Tower by Applying Polymer Insulation Arms (암절연물을 적용한 송전철탑 연구)

  • Park, Hoy-Yul;Ahn, Myeong-Sang;Lee, Tae-Joo;Lee, Dong-II;Choi, In-Hyuk;Kim, Joung-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.1-4
    • /
    • 2005
  • The electric power demand is steadily high. It becomes difficult to secure the land for overhead transmission lines year after year. Downsizing of overhead transmission lines can be most effectively achieved by applying polymer insulation arm. This paper describes the outline of compact overhead transmission lines and the result of mechanical evaluation of FRP for the compact transmission towers. Bending strength of FRP was evaluated according to the fiber orientation because the fiber orientation in FRP has a great effect on the strength of FRP.

  • PDF

Numerical Analysis of Heat Flow and Thermal Deformation in Transmission Joining of Polymers Using Nd:YAG Laser (Nd:YAG 레이저를 이용한 폴리머의 투과접합에서 열 유동 및 열 변형 해석)

  • Cha, Sang-Woo;Kim, Jin-Beom;Na, Suck-Joo
    • Journal of Welding and Joining
    • /
    • v.24 no.6
    • /
    • pp.28-32
    • /
    • 2006
  • Laser Transmission Joining (LTJ), which is a joining process of polymers by using different transmission rates of materials, was studied numerically. Unlike previous studies, energy loss by reflection at the surface was included. Besides, energy absorbed in the transparent substrate is also considered to increase the accuracy of the analytical results. Furthermore, thermal deformations of the substrates were also calculated. Temperature distribution of the substrates on the joining process could be effectively predicted by using the thermal analysis model developed, which could also analyze the rising phenomenon of the absorbing substrate by bulge effect. Calculated results show that temperature of the absorbing substrate is higher than that of transparent substrate when the laser is being radiated, and this temperature difference causes more thermal deformation in absorbing substrate, which results in the surface rise of the absorbing substrate. Comparison of calculated results with corresponding experimental results could confirm the validity of the numerical analysis model proposed.

Reliability Assessment of Forest Fire on EHV Polymer Insulator Strings (송전용 폴리머애자의 산불 영향 신뢰성 평가)

  • Min, Byeong-Wook;Shin, Tai-Woo;Choi, In-Hyuk;Choi, Han-Yeol;Park, Jae-Ung;Yu, Kun-Yang
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.436-437
    • /
    • 2006
  • Porcelain insulators have generally been used in Korea but polymer insulators which are superior in that they are light weight, explosion proof, impact proof, economical with construction characteristics, have been in use for the 154kV transmission line since 1999 following a worldwide trend towards the reduced weight, simplification and compact usage of new material insulators. However there have been approximately 500 cases of forest fires in Korea, so the transmission lines that for the most part pass through mountainous areas have been highly effected and the highly polymerized compound polymer insulator has raised concern about reliability in cases of exposure to forest fires. Therefore for the reliability assessment of the effect of forest fires on polymer insulators, mechanical and electrical characteristics are analyzed by an artificial flare test device and transmission facility surrounding conditions along with forest fire characteristics are surveyed. In addition to this, actual 90kV energized transmission line was tested with an artificial forest fire and the expanded usage of polymer insulators is presented through the analysis of mechanical and electrical characteristics and physical properties, and a study on the influence of forest fires on polymer insulators.

  • PDF

A study on the determination of gear ratios and shifting pattern of automatic transmission for increasing vehicle performance (동력성능 향상을 위한 차량용 자동 변속기의 최적 변속비 및 변속 패턴 결정에 관한 연구)

  • 조선휘;류길하;김태용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1436-1445
    • /
    • 1990
  • Performance of vehicles depends mainly on engine performance, transmission gear ration and shifting pattern. In this paper, determination method of gear ratios and shifting pattern for automatic transmission equipped vehicles has been proposed. Computer programs for gear ratio determination and shifting pattern decision using optimal design technique have been developed for the purpose of increasing vehicle acceleration performance. For preceding study, computer simulation of vehicle performance is carried out using numerical technique.

Analysis of Transmission Error for Stepping Motor Drive Timing Belt System (스테핑 모터 구동 타이밍벨트 시스템의 전동오차 해석)

  • Kim, Hyun-Soo;Wee, Hyuk
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.4
    • /
    • pp.649-657
    • /
    • 1992
  • Transmission error for a stepping motor-timing belt drive system is investigated experimentally and analytically. From FFT analysis of the experimental results, it is found that the transmission error consists of three periodic errors : (1) error by the stepping motor per one resolution angle theta.$_{m}$, (2) error by the pulley eccentricity per one revolution theta.$_{e}$, and (3) error by the meshing effect between the belt and the pulley teeth per one pitch revoltion theta.$_{p}$. In order to investigate the effects of some design parameters on the transmission error, the dynamic models of the stepping motor-timing belt drive system are derived by Bondgraph. According to the simulation results, as the belt total tension increases, theta.$_{m}$ and theta.$_{e}$ decrease due to the nonlinearity of the belt. In adition, the numerical and experimental results show that theta.$_{m}$ and theta.$_{e}$ of the loaded case are larger than those of the unloaded case. The analytical results are in good accordance with the experimental results.sults.s.sults.