• Title/Summary/Keyword: Mechanical system

Search Result 19,925, Processing Time 0.048 seconds

IGRINS First Light Instrumental Performance

  • Park, Chan;Yuk, In-Soo;Chun, Moo-Young;Pak, Soojong;Kim, Kang-Min;Pavel, Michael;Lee, Hanshin;Oh, Heeyoung;Jeong, Ueejeong;Sim, Chae Kyung;Lee, Hye-In;Le, Huynh Anh Nguyen;Strubhar, Joseph;Gully-Santiago, Michael;Oh, Jae Sok;Cha, Sang-Mok;Moon, Bongkon;Park, Kwijong;Brooks, Cynthia;Ko, Kyeongyeon;Han, Jeong-Yeol;Nah, Jakyuong;Hill, Peter C.;Lee, Sungho;Barnes, Stuart;Park, Byeong-Gon;T., Daniel
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.52.2-52.2
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is an unprecedentedly minimized infrared cross-dispersed echelle spectrograph with a high-resolution and high-sensitivity optical performance. A silicon immersion grating features the instrument for the first time in this field. IGRINS will cover the entire portion of the wavelength range between 1.45 and $2.45{\mu}m$ accessible from the ground in a single exposure with spectral resolution of 40,000. Individual volume phase holographic (VPH) gratings serve as cross-dispersing elements for separate spectrograph arms covering the H and K bands. On the 2.7m Harlan J. Smith telescope at the McDonald Observatory, the slit size is $1^{\prime\prime}{\times}15^{\prime\prime}$. IGRINS has a $0.27^{\prime\prime}$ pixel-1 plate scale on a $2048{\times}2048$ pixel Teledyne Scientific & Imaging HAWAII-2RG detector with SIDECAR ASIC cryogenic controller. The instrument includes four subsystems; a calibration unit, an input relay optics module, a slit-viewing camera, and nearly identical H and K spectrograph modules. The use of a silicon immersion grating and a compact white pupil design allows the spectrograph collimated beam size to be 25mm, which permits the entire cryogenic system to be contained in a moderately sized rectangular vacuum chamber. The fabrication and assembly of the optical and mechanical hardware components were completed in 2013. In this presentation, we describe the major design characteristics of the instrument and the early performance estimated from the first light commissioning at the McDonald Observatory.

  • PDF

Progress Report on NISS onboard NEXTSat-1

  • Jeong, Woong-Seob;Park, Sung-Joon;Park, Kwijong;Moon, Bongkon;Lee, Dae-Hee;Pyo, Jeonghyun;Park, Youngsik;Kim, Il-Joong;Park, Won-Kee;Lee, Duk-Hang;Park, Chan;Ko, Kyeongyeon;Nam, Ukwon;Han, Wonyong;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.49.1-49.1
    • /
    • 2014
  • The NISS (Near-infrared Imaging Spectrometer for Star formation history) onboard NEXTSat-1 is the near-infrared instrument onboard NEXTSat-1 which is being developed by KASI. The imaging low-resolution spectroscopic observation in the near-infrared range for nearby galaxies, low background regions, star-forming regions and so on will be performed on orbit. After the System Requirement Review, the optical design is changed from on-axis to the off-axis telescope which has a wide field of view (2 deg. ${\times}$ 2 deg.) as well as the wide wavelength range from 0.95 to $3.8{\mu}m$. The mechanical structure is considered to endure the launching condition as well as the space environment. The design of relay optics is optimized to maintain the uniform optical performance in the required wavelength range. The stray light analysis is being made to evade a light outside a field of view. The dewar is designed to operate the infrared detector at 80K stage. From the thermal analysis, we confirmed that the telescope can be cooled down to around 200K in order to reduce the large amount of thermal noise. Here, we report the current status of the NISS development.

  • PDF

The Philosophy of Martin Buber(I and Thou) and Nursing Philosophy (마르틴 부버의 사상(나와 너)과 간호철학)

  • Lee, Myoung-Suk;Han, Sung-Suk
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.3 no.2
    • /
    • pp.95-107
    • /
    • 1997
  • For nursing as a science to establish a unique system of knowledge, nursing researchers should include the philosophical activities such as establish of nursing philosophy. For establish of philosophy nursing, the nature and realms and essential characteristics of nursing science should be made clear at first. The purpose of this study identify alienation and the situation of happen to alienation and Martin Buber Philosophy(I and Thou). Understanding of this concept should enlighten nurses to interaction and relationship problems between patients and nurse and thus lead to further toward enhancing these interaction and relationship. The alienation was serious problem in present society which was cultural, political, economical, mechanical, religious classified. The overcome of alienation in nursing situation was caring and interpersonal relationship based on Martin Buber philosophy. The essential philosophy of Martin Buber was "I and Thou" relationship. I and Thou relationship are consist of five characteristics ; 1)mutuality 2)directness 3)presentness 4)intensity 5)ineffability As health care technology becomes more sophisticated, there is a tendency to rely on monitors and machines to assess the patient's status. Therefore focus on the functioning and care of machine can result in less meaningful communication with patients. This study points to the need for health professional and patient relationship based on Martin Buber philosophy(I and Thou). This relationship may suggest that professional shoud have sincerity, concerning, respect and warm emotional toward their patients. Ultimately this study provide the basic information to contribute understanding of "I and Thou" relationship and nursing philosophy development in nursing education.

  • PDF

Initial Responses of Understory Vegetation to 15% Aggregated Retention Harvest in Mature Oak (Quercus mongolica) Forest in Gyungsangbukdo (경상북도 신갈나무 성숙림에서 15% 군상잔존벌 이후 초기 하층식생 변화)

  • Ming, Zhang;Kim, Jun-Soo;Cho, Yong-Chan;Bae, Sang-Won;Yun, Chung-Weon;Byun, Bong-Kyu;Bae, Kwan-Ho
    • Journal of Korean Society of Forest Science
    • /
    • v.102 no.2
    • /
    • pp.239-246
    • /
    • 2013
  • This study observed changes of understory vegetation to evaluate the role of forest aggregate after 15% aggregated retention harvest in mature oak forest (> 100 years) in Gyungsangbukdo Bonghwagun in 2010 and 2011. Spontaneous responses of understory vegetation cover (%), species richness, abundance of plant growth forms (herbaceous and woody plants), and overall attributes (by Ordination analysis) were estimated in aggregate area (0.15 and n=36) and clear cut area (0.85 and n=192) in experimental site and control site (1 and n=300). Based on ordination analysis, overall change of species composition in aggregated sites were relatively lower than in harvest area. Right after treatment, total cover of cutted area slightly decreased from 15.6% to 14.7%, and species richness increased from 14 species to 22 species. Cover and richness in the both of aggregate and control sites increased. In plant growth forms, 15% aggregate harvest revealed positive effects on the abundance (cover and richness) of herbaceous plants than woody group. After retention treatment, overall, edge effect likely played major component of vegetation changes in aggregate forest and in harvested area, mechanical damage from harvest operation and change of forest structure by clear cutting were critical. As pre-treatment data, which are rare in ecological studies in Korea, were critical for interpretation between patterns that may have arisen from spatial distributions in the original forest, our experimental design have higher opportunity for long term monitoring on the effect of forest aggregate and vegetation regeneration in clear cutted area.

TREATMENT OF COMPOSITE RESIN RESTORATION WITH THE AIR ABRASIVE TECHNIQUE (Air abrasive technique을 이용한 복합레진 수복 증례)

  • Lee, Chang-Woo;Jang, Ki-Taeg;Lee, Sang-Hoon;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.4
    • /
    • pp.763-770
    • /
    • 1997
  • The air abrasive technique is a non-mechanical method by which teeth are treated before restoration and stains and calculi are removed from tooth surfaces using the kinetic energy of small particles. The air abrasive technique in dentistry was first introduced in the 1950's with as instrument called 'Airdent'. But, as the main restorative materials of the period were amalgam and gold, and the instrument's inability to control the flow of particles caused the particles to be spread throughout the clinics, widespread use was not possible. In the 1990's, as these techincal problems were solved and more interest in new restorative materials rose in an effort to preserve sound tooth structure, new developements took place in instruments related to the air abrasive technique. The air abrasive technique produces less pressure, vibration and heat that might cause patient discomfort and facilitates the preservation of sound tooth structure. It also reduces the need for anesthesia and is less harmful to the pulp. Other advantages include increase in dentin bonding strength of composite resin, lower possibility of saliva contamination and maintenance of a dry field. But there is not direct contact between the nozzle and the tooth, the operator cannot use his or her tactile sense and must rely solely upon visual input. Other disadvantages are: the tooth preparation depends on the operator's ability; alpha-alumina particles, after bouncing off the tooth surface, cause damage to dental mirrors; the equipment is expensive and takes up a certain amount of space in the clinic. The author conducted case report using the air abrasive technique on patient visiting the Department of Pediatric Dentistry at Seoul National University Dental Hospital and arrived at the following conclusions. 1. The tooth preparation capability of different air abrasive devices varied widely among manufacturers. 2. It was more effective in treating early caries lesions and stains compared to lesions where caries had already progressed to produce soft dentin. 3. The cold stream and noise caused by the evacuation system was a major cause of discomfort to pediatric patients. 4. As there is no direct contact with tooth surface when using the air abrasive technique for tooth preparation, considerable experience and skill is required for proper tooth preparation.

  • PDF

A Study on Estimation of Human Damage Caused by Rupture of Butane Can (부탄 캔 파열로 인한 인체피해예측에 관한 연구)

  • Leem, Sa-Hwan;Huh, Yong-Jeong;Choi, Seong-Joo;Lee, Jong-Rark;Lim, Dong-Yeon
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.98-104
    • /
    • 2007
  • As the industrial society is highly developing, human need in daily life has also changed drastically. With the introduction of 40 hour working week system, more households enjoy picnics on weekends. More gas accidents take place on Saturdays and on Sundays than any other days of week. In this context, the Institute of Gas Technology Training in Korea Gas Safety Corporation carries out explosion experiment to make trainees to take all possible measure to ensure safe management of gas in the field by fully recognizing the hazards of gas explosion accidents. In this study, the influence of explosion over-pressure caused by the rupture of butane can thrown away after use was calculated by using the Hopkinson's Scaling Law and the accident damage was estimated by applying the influence on the adjacent people into the Probit model. The value of those away from 50 meters from the explosion site was 1.35kPa and the peak overpressure to thoes away from 25 meters directly was 3.2kPa. Those value was input to the PROBIT model, the estimation showed the sante result 0 percent of damage possibility.

The Effect of Additives on the Preparation of Nanosized TiO2 Particles (나노크기 TiO2의 제조에 미치는 첨가제 영향)

  • Kim, Seok-Hyeon;Na, Seok-En;Kim, Si-Young;Kim, Seong-Soo;Ju, Chang-Sik
    • Korean Chemical Engineering Research
    • /
    • v.51 no.4
    • /
    • pp.426-431
    • /
    • 2013
  • Nanosized $TiO_2$ particles were prepared from titanium (IV) sulfate solution using base solutions at low reaction temperature ($95^{\circ}C$) and atmospheric pressure by hydrothermal precipitation method without calcination. The effects of preparation conditions, such as kind of base solutions (NaOH, $NH_4OH$, Monoethanolamine, Diethanolamine, Triethanolamine) and surfactants (CTAB, Span 20, SDBS), concentration of surfactants, temperature and pH, on the physical properties of $TiO_2$ particles have been investigated by XRD, SEM and Zeta-potential meter. Absorption area was also investigated by DRS in order to confirm the photocatalytic activity of the nanosized $TiO_2$ particles. It was turned out that, among base solutions, NaOH provides the smallest $TiO_2$ particles with excellent crystallinity. And cationic surfactant (CTAB) prepared smaller $TiO_2$ particles than any other surfactants. When CTAB is added in the concentration ratio of $Ti(SO_4)_2$:CTAB=10:1, $TiO_2$ particles with particle diameter of 5.8 nm were prepared. This is approximately 1/10 of that prepared without CTAB.

Preparation of Pt Catalysts for 2-propanol Dehydrogenation using Sol-gel Method (솔-젤법을 이용한 2-propanol 탈수소화 반응 Pt 촉매의 제조)

  • Lee, Yeong-Kweon;Lee, Hwaung;Song, Hyung Keun;Na, Byung-Ki
    • Korean Chemical Engineering Research
    • /
    • v.45 no.4
    • /
    • pp.328-334
    • /
    • 2007
  • Chemical heat pump system of 2-propanol/acetone/hydrogen is most suitable to the recovery of waste heat of power plant. various types of 5 wt% Pt-alumina catalysts were prepared for 2-propanol dehydrogenation using sol-gel method. The characteristics and the dehydrogenation reaction rate of each catalyst were investigated. Pt-alumina xerogel catalyst has excellent reaction rate and good durability in comparison with the existing alumina supported Pt catalysts. Pt-alumina aerogel catalyst had the highest reaction rate in all prepared catalysts, but sufficient aging time was necessary to maintain its reaction rate. A potential advantage of the aerogel catalyst is the fact that the high temperature heat treatment is not required. Without heat treatment or with low temperature heat treatment, the Pt-alumina aerogel catalyst has excellent reaction rate as well as durability and this gives us the economic advantage. Alumina xerogel supported Pt catalyst prepared by incipient wetness method showed good reaction rate, and had good mechanical strength. Blank alumina xerogel prepared by sol-gel method can be used for the support of metal catalysts.

Sound quality metrics to express the discomfort of overload excavator noise during operation (과부하 굴삭기 소음의 불쾌감 표현인자)

  • Sim, Sangdeok;Song, Ohseop
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.3
    • /
    • pp.147-155
    • /
    • 2018
  • In this paper, we tried to find out sound quality metrics to express discomfort of overload excavator noise and to develop sound quality indexes through multiple regression analysis by using them. For this purpose, the interior noise of cabin under overload condition was recorded for six excavator models with different noise properties and Jury test was carried out by PCM (Paired Comparison Method) and MEM (Magnitude Estimation Method). Jury test result with low consistency was classified into two groups with different preference tendencies by cluster analysis and multiple regression analysis was conducted in order to find out which sound quality metrics have significant effects on discomfort(low preference). As a result, we figured out that the sound quality metrics to express the discomfort were the partial loudness (= $PN_{10Bark}$) between 0 and 10 Bark in case of group1 and the difference between engine noise(= $dB_{EG}$) and hydraulic system noise ($dB_1$) in case of group2. Using the results of preference ranking and tendency analysis of PCM followed by the correlation analysis between PCM and MEM, the more reliable results were adopted by excluding the data with low consistency obtained from Jury test via MEM.

Spatial dispersion of aggregate in concrete a computer simulation study

  • Hu, Jing;Chen, Huisu;Stroeven, Piet
    • Computers and Concrete
    • /
    • v.3 no.5
    • /
    • pp.301-312
    • /
    • 2006
  • Experimental research revealed that the spatial dispersion of aggregate grains exerts pronounced influences on the mechanical and durability properties of concrete. Therefore, insight into this phenomenon is of paramount importance. Experimental approaches do not provide direct access to three-dimensional spacing information in concrete, however. Contrarily, simulation approaches are mostly deficient in generating packing systems of aggregate grains with sufficient density. This paper therefore employs a dynamic simulation system (with the acronym SPACE), allowing the generation of dense random packing of grains, representative for concrete aggregates. This paper studies by means of SPACE packing structures of aggregates with a Fuller type of size distribution, generally accepted as a suitable approximation for actual aggregate systems. Mean free spacing $\bar{\lambda}$, mean nearest neighbour distance (NND) between grain centres $\bar{\Delta}_3$, and the probability density function of ${\Delta}_3$ are used to characterize the spatial dispersion of aggregate grains in model concretes. Influences on these spacing parameters are studied of volume fraction and the size range of aggregate grains. The values of these descriptors are estimated by means of stereological tools, whereupon the calculation results are compared with measurements. The simulation results indicate that the size range of aggregate grains has a more pronounced influence on the spacing parameters than exerted by the volume fraction of aggregate. At relatively high volume density of aggregates, as met in the present cases, theoretical and experimental values are found quite similar. The mean free spacing is known to be independent of the actual dispersion characteristics (Underwood 1968); it is a structural parameter governed by material composition. Moreover, scatter of the mean free spacing among the serial sections of the model concrete in the simulation study is relatively small, demonstrating the sample size to be representative for composition homogeneity of aggregate grains. The distribution of ${\Delta}_3$ observed in this study is markedly skew, indicating a concentration of relatively small values of ${\Delta}_3$. The estimate of the size of the representative volume element (RVE) for configuration homogeneity based on NND exceeds by one order of magnitude the estimate for structure-insensitive properties. This is in accordance with predictions of Brown (1965) for composition and configuration homogeneity (corresponding to structure-insensitive and structure-sensitive properties) of conglomerates.