• 제목/요약/키워드: Mechanical stimulation

검색결과 195건 처리시간 0.037초

Long-term Follow-up of Cutaneous Hypersensitivity in Rats with a Spinal Cord Contusion

  • Jung, Ji-In;Kim, June-Sun;Hong, Seung-Kil;Yoon, Young-Wook
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제12권6호
    • /
    • pp.299-306
    • /
    • 2008
  • Sometimes, spinal cord injury (SCI) results in various chronic neuropathic pain syndromes that occur diffusely below the level of the injury. It has been reported that behavioral signs of neuropathic pain are expressed in the animal models of contusive SCI. However, the observation period is relatively short considering the natural course of pain in human SCI patients. Therefore, this study was undertaken to examine the time course of mechanical and cold allodynia in the hindpaw after a spinal cord contusion in rats for a long period of time (30 weeks). The hindpaw withdrawal threshold to mechanical stimulation was applied to the plantar surface of the hindpaw, and the withdrawal frequency to the application of acetone was measured before and after a spinal contusion. The spinal cord contusion was produced by dropping a 10 g weight from a 6.25 and 12.5 mm height using a NYU impactor. After the injury, rats showed a decreased withdrawal threshold to von Frey stimulation, indicating the development of mechanical allodynia which persisted for 30 weeks. The withdrawal threshold between the two experimental groups was similar. The response frequencies to acetone increased after the SCI, but they were developed slowly. Cold allodynia persisted for 30 weeks in 12.5 mm group. The sham animals did not show any significant behavioral changes. These results provide behavioral evidence to indicate that the below-level pain was well developed and maintained in the contusion model for a long time, suggesting a model suitable for pain research, especially in the late stage of SCI or for long term effects of analgesic intervention.

말기 심질환 환자를 위한 심실보조장치용 심박조율기의 개발 (Development of a Pacemaker with a Ventricular Assist Device for End-Stage Heart Failure Patients)

  • 김유석;박성민;최성욱
    • 대한기계학회논문집B
    • /
    • 제35권11호
    • /
    • pp.1205-1211
    • /
    • 2011
  • 본 논문은 말기 심질환 환자의 생존율과 치료효과를 증대시키기 위한 심실보조장치용 심박조율기의 개발에 대한 내용이다. 심실보조장치만을 이식 받은 환자는 부정맥이 발생할 가능성을 항상 갖고 있으며 심박조율기를 동시에 적용함으로써 혈류의 체순환량을 유지하고 부정맥으로 인한 장기의 손상을 예방한다. 심박조율기의 전극과 도선은 심실보조장치의 도관을 이용하여 제작되었으며, 전극은 심실보조장치의 도관이 삽관되는 좌심실의 심첨부에 도관과 함께 이식된다. 심박조율기는 0 bpm에서부터 191.4 bpm까지 자극 빈도를 조절할 수 있으며, 60 bpm의 빈도로 자극이 가하여 질 때 0.25 J 의 에너지가 심장으로 인가된다. 심실보조장치용 심박조율기의 성능과 안정성을 검증하기 위하여 돼지를 이용한 동물실험을 수행하였다. 실험동물의 심장에 86.4 bpm, 100.2 bpm, 126.6 bpm의 자극을 순차적으로 가하였고 ECG 및 대동맥혈압의 변화 대동맥 혈류를 관찰하였다.

바이오센서

  • 홍승홍
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권2호
    • /
    • pp.109-111
    • /
    • 1989
  • An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients.

  • PDF

A Conceptual Design of an Integrated Tactile Display Device

  • Son, Seung-Woo;Kyung, Ki-Uk;Yang, Gi-Hun;Kwon, Dong-Soo;Kim, Mun-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2753-2758
    • /
    • 2003
  • Tactile sensation is essential for many manipulation and exploration tasks not only in a real environment but also in a virtual environment. In this paper, we discuss a conceptual design of an integrated tactile display system. The system comprises two parts: a 2 DOF force feedback device for kinesthetic display and a tactile feedback device for displaying the normal stimulation to skin and the skin slip/stretch. Psychophysical experiments measure the effects of fingerpad selection, the direction of finger movements and the texture width on tactile sensitivity. We also investigate characteristics of lateral finger movement while subjects perceive different textures. From the experimental results, the principal parameters for designing a tactile display are suggested. A tactile display device is implemented using eight piezoelectric bimorphs and a linear actuator, and is attached to a 2 DOF translational force feedback device to simultaneously simulate texture and stiffness of the object.

  • PDF

토끼 흉부 대동맥 절편의 전기자극에 대한 수축 및 이완반응 (Electrical Stimulation Causes Endothelium-Dependent Relaxation in Isolated Aortic Vessels of the Rabbit)

  • 이석기;최형호;이종운
    • Journal of Chest Surgery
    • /
    • 제28권8호
    • /
    • pp.742-746
    • /
    • 1995
  • The present study was aimed at investigating possible transmitter mechanisms in the endothelial cell layer in regulating the tone of the vascular smooth muscle. The thoracic aorta was isolated from the anesthetized male white rabbits and its helical strips were prepared. Electrical field stimulation was delivered to platinum wire electrodes positioned parallel to the vessel segment preconstricted with phenylephrine [3.5x10-6 mol/L at a distance of 1.5-2.0 mm. The electrical stimulation [70 V, 5 msec, 0.5-200 Hz caused either relaxation only [34% or a biphasic response [prolonged relaxation following a weak and transient contraction, 66% . The relaxation response was frequency- dependent, and at 200 Hz a complete relaxation was noted. Mechanical rubbing of the endothelial layer abolished or greatly attenuated the relaxation. The relaxation was also markedly attenuated in the presence of NG-nitro- L-arginine methyl ester [10-3mol/L or procaine hydrochloride [3.5x10-4mol/L . Tetrodotoxin,guanethidine, atropine or indomethacin failed to block or enhance the relaxation response to electrical field stimulation. It is concluded that the vascular endothelium in the aorta contains diffusible substances that regulates the function of the smooth muscle layer, in which relaxation is more prominent than contraction. Their release by the electrical stimualtion in vitro may not involve classic neuronal transmitter release mechanisms or metabolism of arachidonic acids by cyclooxygenase. The release of the relaxing agents may require an increase in cytosolic calcium level. The chemical nature of the relaxant may be, to a large extent, nitric oxide.

  • PDF

Sensory Inputs to Upper Cervical Spinal Neurons Projecting to Midbrain in Cats

  • Kim, Jong-Ho;Jeong, Han-Seong;Park, Jong-Seong;Kim, Jong-Keun;Park, Sah-Hoon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제2권1호
    • /
    • pp.9-19
    • /
    • 1998
  • The present study was primarily carried out to characterize the properties of the spinomesencephalic tract (SMT) neurons that project from the upper cervical spinal segments to the midbrain. It was also investigated whether these neurons received convergent afferent inputs from other sources in addition to cervical inputs. Extracellular single unit recordings were made from neurons antidromically activated by stimulation of midbrain. Recording sites were located in lamina $I{\sim}VIII\;of\;C1{\sim}C3$ segments of spinal cord. Receptive field (RF) and response properties to mechanical stimulation were studied in 71 SMT neurons. Response profiles were classified into six groups: complex (Comp, n=9), wide dynamic range (WDR, n=16), low threshold (LT, n=5), high threshold (HT, n=6), deep/tap (Deep, n=10), and non- responsive (NR, n=25). Distributions of stimulation and recording sites were not significantly different between SMT groups classified upon their locations and/or response profiles. Mean conduction velocity of SMT neurons was $16.7{\pm}1.28\;m/sec$. Conduction velocities of SMTs recorded in superficial dorsal horn (SDH, n=15) were significantly slower than those of SMTs recorded in deep dorsal horn (DDH, n=18), lateral reticulated area (LRA, n=21), and intermediate zone and ventral horn (IZ/VH, n=15). Somatic RFs for SMTs in LRA and IZ/VH were significantly larger than those in SDH and DDH. Five SMT units (4 Comps and 1 HT) had inhibitory somatic RFs. About half (25/46) of SMT units have their RFs over trigeminal dermatome. Excitabilities of 5/12 cells and 9/13 cells were modulated by stimulation of ipsilateral phrenic nerve and vagus nerve, respectively. These results suggest that upper cervical SMT neurons are heterogenous in their function by showing a wide range of variety in location within the spinal gray matter, in response profile, and in convergent afferent input.

  • PDF

침자기전(鍼刺機轉)의 중추신경계(中樞神經系)에서의 신경해부(神經解剖).생리학적(生理學的) 기초연구(基礎硏究) (A Neuroanatomical and Neurophsiolgical basic Study on the Mechanism of Acupuncture in central nervous system)

  • 김정헌
    • 한국한의학연구원논문집
    • /
    • 제2권1호
    • /
    • pp.514-550
    • /
    • 1996
  • There are many theory in acupuncture mechanism, so we must know the detail contents. and then we can use the acupuncture as we know. the follow article will be helpful in this part. 1. Spinal cord are role in intermediate part in somatosensorypathway also in acupuncture stumulating tract 2. Acute pain pathway started in laminae I, V of gray colmn, next are the spinothalamic tract(trigeminal spinothalamic tract in above neck part) and then go to the specific thalamic nucleus. but chronic pain in laminae II, III, VI, VII, next are spinoreticular tract(trigeminal spinoreticular tract in the neck part) and finally to the nonspecific thalamic nucleus. 3. Thalamus is very important area in somatosensory stimuation including acupuncture stumulating sensory also as a pain control center. but except this, there are Hypothalamus, Limbic system Cerebral cortex and Cerebellum as intermediator. as we Know hypothalamus is related to the emotional analgesic system with a limbic system. 4. A ${\delta$ fiber has relationship in Acute, sharp and initial pain, contrary this C fiber is related with Chronic, dull and last pain. 5. In Acupuncture mechanism of pain analgesia, there are two theory, one is gate control theory as large fiber another is stimuation produced analgesia as small diameter fier. 6. In DNIC, the stimulation sources are mechanical, thermal, heating, pain and acupuncture stimulation etc. we call these as a Heterotopic Noxious Stimulation. 7. In DNIC, SRD(Subnucleus reticularis dorsalis)is core nucleus in pain imtermediated analgesic mechanism. 8. Takeshige insisted nonacupuncture point dependent analgesic mechanism and acupuncture point dependent analgesic mechanism. and protested that Stimulation acupuncture piing evoke blocking nomacupuncture point analgesic pathway.

  • PDF

The Effect of Frequency of Transcutaneous Electrical Nerve Stimulation (TENS) on Maximum Multi-finger Force Production

  • Karol, Sohit;Koh, Kyung;Kwon, Hyun Joon;Park, Yang Sun;Kwon, Young Ha;Shim, Jae Kun
    • 한국운동역학회지
    • /
    • 제26권1호
    • /
    • pp.93-99
    • /
    • 2016
  • Objective: The purpose of this study was to investigate the effect of transcutaneous electrical nerve stimulation (TENS) treatment on maximum voluntary force (MVF) production. Methods: Ten healthy, young subjects (5 males and 5 females) participated in the study. MVF was recorded after a fifteen minute session of TENS stimulation under two conditions: low frequency (4 Hz) at maximum tolerable level and high frequency (110 Hz) at maximum tolerable level. TENS was provided simultaneously via self-adhesive electrodes placed on the finger pads of the index, middle, ring and little fingers. MVF was also recorded in a baseline condition with no TENS treatment. Data were collected in three different sessions on three consecutive days at the sametime of the day. Results: Results from the study show that on an average, MVF increasesby 25% for the index, middle and little fingers for TENS treatment with 4 Hz frequency as compared to the baseline condition. However, the 110 Hz condition did not result in a significantly different MVF than the baseline condition during individual finger pressing tasks. In addition, while producing MVF with all the four finger stogether, MVF was 30% higher for the 4 Hz conditionin comparison to the baseline condition, and 15% higher for the 110 Hz condition in comparison to the baseline condition respectively. Conclusion: The results suggest that stimulation ofafferent fibers onthe glabrous skinwith TENS could have a net facilitatory effect on the maximum motoroutput.

수압파쇄 설계를 위한 수치해석기법의 증명 -해석식과의 비교를 중심으로 - (Verification of Numerical Technique for Hydraulic Fracturing Stimulation - by Comparison with Analytical Solutions -)

  • 심영종
    • 한국지반환경공학회 논문집
    • /
    • 제10권4호
    • /
    • pp.65-71
    • /
    • 2009
  • 수압파쇄기술은 가스나 석유, 지열 등 자원추출을 하기 위해 다양한 분야에서 전세계적으로 응용되고 있는 기술이다. 이러한 수압파쇄 작업 시 복수의 균열이 필수적으로 발생하여 균열간 기계적인 상호작용을 유발하는데 이러한 상호작용은 수압파쇄시 얻어질 수 있는 결과(균열 폭, 균열 길이, 보어홀 내 압력)에 큰 영향을 끼치게 된다. 수치해석기법인 경계병치법은 이러한 균열간의 역학적 상호작용을 고려하는데 유효한 수치해석적 기법으로 개발이 되고 있으나 응력확대계수를 계산하는 해석식과의 비교 등을 통한 검증이 필요하다. 이를 위해 무한평면에 일축 인장 응력과 전단응력이 작용하는 단일균열의 경우 및 임의의 두 균열이 존재하는 경우의 응력확대계수 및 균열폭 해석식과 본 수치해석기법을 통해 얻은 값을 비교하였다. 그 결과, 본 연구에서 제시한 경계병치법은 해석식과 상당히 근접한 결과를 나타내어, 균열간의 기계적인 상호작용을 고려하는데 유효함을 검증하였으며, 추후 수압파쇄 시 설계에 필요한 균열폭 등의 변수를 계산하는데 사용할 수 있음을 나타내었다.

  • PDF

Responses of Dorsal Horn Neurons to Peripheral Chemical Stimulation in the Spinal Cord of Anesthetized Cats

  • Jung, Sung-Jun;Park, Joo-Min;Lee, Joon-Ho;Lee, Ji-Hye;Eun, Su-Yong;Kim, Sang-Jeong;Lim, Won-Il;Cho, Sun-Hee;Kim, Jun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제4권1호
    • /
    • pp.15-24
    • /
    • 2000
  • Although nociceptive informations are thought to be processed via different neural mechanisms depending on the types of stimuli, sufficient data have not been accumulated yet. We performed a series of experiments to elucidate the possible neural mechanisms as to chemical stimuli such as formalin, capsaicin and ATP. Single unit activity of wide dynamic range (WDR) neurons and high threshold cells were recorded extracellularly from the lumbosacral enlargement of cat spinal cord before and after chemical stimulation to its receptive field (RF). Each chemical substance - formalin $(20{\mu}l,\;4%),$ capsaicin (33 mM) or Mg-ATP (5 mM)- was injected intradermally into the RFs and then the changes in the spontaneous activity, mechanical threshold and responses to the peripheral mechanical stimuli were observed. In many cases, intradermal injection of formalin (5/11) and capsaicin (8/11) resulted in increase of the spontaneous activity with a biphasic pattern, whereas ATP (8/8) only showed initial responses. Time courses of the biphasic pattern, especially the late response, differed between formalin and capsaicin experiments. One hour after injection of each chemical (formalin, capsaicin, or ATP), the responses of the dorsal horn neurons to mechanical stimuli increased at large and the RFs were expended, suggesting development of hypersensitization (formalin 6/10, capsaicin 8/11, and ATP 15/19, respectively). These results are suggested that formalin stimulates peripheral nociceptor, local inflammation and involvement of central sensitization, capsaicin induces central sensitization as well as affects the peripheral C-polymodal nociceptors and neurogenic inflammation, and ATP directly stimulates peripheral nociceptors.

  • PDF