• Title/Summary/Keyword: Mechanical complication

Search Result 152, Processing Time 0.025 seconds

Surgical treatment for dysesthesia after overfilling of endodontic material into the mandibular canal (하치조신경관으로 과충전된 근관치료 충전재에 의한 감각이상의 외과적 처치)

  • Song, Jae-Min;Kim, Yong-Deok;Lee, Jae-Yeol
    • The Journal of the Korean dental association
    • /
    • v.54 no.11
    • /
    • pp.874-879
    • /
    • 2016
  • Damage to the inferior alveolar nerve(IAN) is a relatively infrequent complication in endodontic treatment. However, endodontic overfilling involving the mandibular canal may cause an injury of the inferior alveolar nerve resulting in sensory disturbances such as pain, dysesthesia, paresthesia or anesthesia. Two mechanism(chemical neurotoxicity and mechanical compression) are responsible for the IAN injury. When absorbent materials overfilled, it can be treated as a non-surgical procedure. But early surgical intervention required when mechanical, chemical nerve damage expected. We report surgical removal of overfilled gutta-percha and IAN decompression through sagittal split osteotomy in case of dysesthesia after overfilling of endodontic material into the mandibular canal. Dysesthesia recovered 3 months after surgical treatment.

  • PDF

Mechanical irritation by protruding bone: A possible cause of breast implant rupture

  • Aitzetmuller, Matthias Michael;Haslhofer, David Johannes;Wenny, Raphael;Schmidt, Manfred;Duscher, Dominik;Huemer, Georg Michael
    • Archives of Plastic Surgery
    • /
    • v.45 no.5
    • /
    • pp.470-473
    • /
    • 2018
  • Although breast implants have been in clinical use for almost 6 decades and have undergone considerable development during this time, implant rupture is still a dreaded long-term complication. Some obvious external factors, such as trauma, can lead to implant rupture, but many studies have reported a high rate of "spontaneous" implant rupture. Herein, we present two cases with the aim of raising awareness of a new possible cause of "spontaneous" implant rupture: mechanical irritation by bony protrusions.

Clinical analysis of 60 cases of open heart surgery (개심술 치험 60례 보)

  • Kim, Su-Seong;Kim, Yeong-Ho;Kim, Gong-Su
    • Journal of Chest Surgery
    • /
    • v.17 no.3
    • /
    • pp.389-397
    • /
    • 1984
  • Sixty cases of open heart surgery were performed in the Department of Thoracic and Cardiovascular Surgery of Chonbuk National University Hospital from July, 1983 to June, 1984. The patients were consisted of 40 [66%] congenital anomalies containing 26 [43%] patients of acyanotic group and 4 [23%] of cyanotic group, and 20 [34%] acquired heart diseases which involved one or more cardiac valves. The male patients were 42 and the female 18. In 20 valvular heart diseases, open mitral commissurotomy was done in 5 patients, mitral valvular replacement with tissue valve in 6, mitral valvular replacement with mechanical valve in 5, mitral valvular replacement with tricuspid annuloplasty in 2, mitral annuloplasty in 1, and mitral and aortic valvular replacements with mechanical valves in 1. The most frequency complication was low cardiac output syndrome occurred in 9, and the next was urethral stenosis, ARDS, and postoperative bleeding, etc. The perioperative mortality was 21% in congenital cyanotic heart disease, 12% in congenital acyanotic heart disease, and 5% in acquired heart disease.

  • PDF

Damage localization in plate-like structure using built-in PZT sensor network

  • Liu, Xinglong;Zhou, Chengxu;Jiang, Zhongwei
    • Smart Structures and Systems
    • /
    • v.9 no.1
    • /
    • pp.21-33
    • /
    • 2012
  • In this study, a Lamb-wave based damage detection approach is proposed for damage localization in plate. A sensor network consisting of three PZT wafer type actuators/sensors is used to generate and detect Lamb waves. To minimize the complication resulted from the multimode and dispersive characteristics of Lamb waves, the fundamental symmetric Lamb mode, $S_0$ is selectively generated through designing the excitation frequency of the narrowband input signal. A damage localization algorithm based upon the configuration of the PZT sensor network is developed. Time-frequency analysis method is applied to purify the raw signal and extract damage features. Experimental result obtained from aluminum plate verified the proposed damage localization approach.

Huge Hematoma in the Pelvic Cavity after Mechanical Valve Replacement - A Report of Case - (기계판막치환술 후 골반강내 대량출혈)

  • 신화균;김남혁;이용재;강창희;권오춘;이길노
    • Journal of Chest Surgery
    • /
    • v.26 no.2
    • /
    • pp.158-159
    • /
    • 1993
  • The hemorragic episode is the major problem of mechanical prosthesis, because of the necessity for anticoagulant therapy to prevent complication of thromboembolism. Double valve replacement was performed to 42 year old male due to aortic stenoinsufficiency and mitral stenosis. For anticoagulant therapy, the patient has been given wafarin under the control of prothrombin time 0.5-2 times of normal) in the our hospital. The patient was injuried the right pelvic area by waves in the beach 4 years after double valve replacement. Pelvic MRI scan showed huge hematoma in the right pelvic cavity. The patient was operated removal of intrapelvic hematoma.

  • PDF

Formulation of Tearing Energy for Fatigue Life Evaluation of Rubber Material (고무의 피로수명 평가를 위한 찢김에너지 정식화)

  • Kim, Heon-Young;Kim, Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.8 s.239
    • /
    • pp.1132-1138
    • /
    • 2005
  • Fatigue life of metal material can be predicted by the use of fracture theory and experimental database. Although prediction of fatigue life of rubber material uses the same way as metal, there are many reasons to make it almost impossible. One of the reasons is that there is not currently used fracture criteria for rubber material beacuse of non-standardization, various way of composition process of rubber and so on. Tearing energy is one of the fracture criteria which can be applied to a rubber. Even if tearing energy relaxes the restriction of rubber composition, it is also not currently used because of complication to apply in. Research material about failure process of rubber and tearing energy was reviewed to define the process of fatigue failure and the applicability of tearing energy in estimation of fatigue life for rubber. Also, 1file element formulation of tearing energy which can be used in FE analysis was developed.

Chronic Lateral Ankle Instability (만성 외측 발목 불안정)

  • Kim, Dae-Wook;Sung, Ki-Sun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.22 no.2
    • /
    • pp.55-61
    • /
    • 2018
  • Chronic lateral ankle instability is a major complication of acute ankle sprains, which can cause discomfort in both daily and sports activity. In addition, it may result in degenerative changes to the ankle joint in the long term. An accurate diagnostic approach and successful treatment plan can be established based on a comprehensive understanding of the concept of functional and mechanical instability. The patients' history and correct physical examination would be the first and most important step. The hindfoot alignment, competence of the lateral ligaments, and proprioceptive function should be evaluated. Additional information can be gathered using standard and stress radiographs. In addition, concomitant pathologic conditions can be investigated by magnetic resonance imaging. Conservative rehabilitation composed of the range of motion, muscle strengthening, and proprioceptive exercise is the main treatment for functional instability and mechanical instability. Regarding the mechanical instability, surgical treatment can be considered for irresponsible patients after a sufficient period of rehabilitation. Anatomic repair (modified $Brostr{\ddot{o}}m$ operation) is regarded as the gold standard procedure. In cases with poor prognostic factors, an anatomical reconstruction or additional procedures can be chosen. For combined intra-articular pathologies, arthroscopic procedures should be conducted, and arthroscopic lateral ligament repair has recently been introduced. Regarding the postoperative management, early functional rehabilitation with short term immobilization is recommended.

Clinical Characteristics of Patients with Acute Organophosphate Poisoning Requiring Prolonged Mechanical Ventilation (장기간 인공환기가 필요한 유기인계 중독환자의 연관인자 분석)

  • Shin, Hwang-Jin;Lee, Mi-Jin;Park, Kyu-Nam;Park, Joon-Seok;Park, Seong-Soo
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.6 no.1
    • /
    • pp.32-36
    • /
    • 2008
  • Purpose: The major complication of acute organophosphate (OP) poisoning is respiratory failure as a result of cholinergic toxicity. Many clinicians find it difficult to predict the optimal time to initiate mechanical ventilation (MV) weaning, and as a result have tended to provide a prolonged ventilator support period. The purpose of this study is to determine any clinical predictors based on patients characteristics and laboratory findings to assist in the optimal timing of mechanical ventilator weaning. Methods: We reviewed medical and intensive care records of 44 patients with acute OP poisoning who required mechanical ventilation admitted to medical intensive care unit between July 1998 and June 2007. Patient information regarding the poisoning, clinical data and demographic features, APACHE II score, laboratory data, and serial cholinesterase (chE) levels were collected. Base on the time period of MV, the patients were divided into two groups: early group (wean time < 7 days, n = 28) and delayed group (${\geq}$ 7 days, n = 16). Patients were assessed for any clinical characteristics and predictors associated with the MV weaning period. Results: During the study period, 44 patients were enrolled in this study. We obtained the sensitivity and specificity values of predictors in the late weaning group. APACHE II score and a reciprocal convert of hypoxic index but specificity (83.8%) is only APACHE II score. Also, the chE concentration (rho = -0.517, p = 0.026) and APACHE II score (rho = 0.827, p < 0.001) correlated with a longer mechanical ventilation duration. Conclusion: In patients with acute OP poisoning who required mechanical ventilation, the APACHE II scoring system on a point scale of less than 17 and decrements in cholinesterase levels on 1-3 days were good predictors of delayed MV weaning.

  • PDF

A Study on Kinematical Modeling and Analysis of Double Side Wafer Polishing Process (실리콘 웨이퍼 양면 연마 공정의 기구학적 모델링과 해석에 관한 연구)

  • Lee, Sang-Jik;Jeong, Suk-Hoon;Lee, Hyun-Seop;Park, Sun-Joon;Kim, Young-Min;Jeong, Hae-Do
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.485-485
    • /
    • 2009
  • Double side polishing process has been used for various industrial applications, such as polishing of semiconductor substrates and flat panel display glasses. In wafer manufacturing, double side polishing process is applied to improve wafer flatness and to minimize particle generation from wafers in device manufacturing processes, which is recognized as one of the most important processes. Whereas the kinematical modeling and analysis results of single side polishing, extensively used for chemical-mechanical polishing (CMP) in device manufacturing, are well investigated, the studies in conjunction with double side polishing are barely carried out, due to the complication of polishing system and the uncertainty of wafer motion in the carrier. This paper suggests the derivation of kinematical model with consideration of carrier and wafer motion in double side polishing, and then presents the effect of kinematical parameters on material removal amount and its non-uniformity. The kinematical analysis results help to understand the double side polishing process and to control the polishing results.

  • PDF

The Evolution of Flow-Diverting Stents for Cerebral Aneurysms; Historical Review, Modern Application, Complications, and Future Direction

  • Shin, Dong-Seong;Carroll, Christopher P.;Elghareeb, Mohammed;Hoh, Brian L.;Kim, Bum-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.2
    • /
    • pp.137-152
    • /
    • 2020
  • In spite of the developing endovascular era, large (15-25 mm) and giant (>25 mm) wide-neck cerebral aneurysms remained technically challenging. Intracranial flow-diverting stents (FDS) were developed to address these challenges by targeting aneurysm hemodynamics to promote aneurysm occlusion. In 2011, the first FDS approved for use in the United States market. Shortly thereafter, the Pipeline of Uncoilable or Failed Aneurysms (PUFS) study was published demonstrating high efficacy and a similar complication profile to other intracranial stents. The initial FDA instructions for use (IFU) limited its use to patients 22 years old or older with wide-necked large or giant aneurysms of the internal carotid artery (ICA) from the petrous segment to superior hypophyseal artery/ophthalmic segment. Expanded IFU was tested in the Prospective Study on Embolization of Intracranial Aneurysms with PipelineTM Embolization Device (PREMIER) trial. With further post-approval clinical data, the United States FDA expanded the IFU to include patients with small or medium, wide-necked saccular or fusiform aneurysms from the petrous ICA to the ICA terminus. However, IFU is more restrictive in South Korea than in United States. Several systematic reviews and meta-analyses have sought to evaluate the overall efficacy of FDS for the treatment of cerebral aneurysms and consistently identify FDS as an effective technique for the treatment of aneurysms broadly with complication rates similar to other traditional techniques. A growing body of literature has demonstrated high efficacy of FDS for small aneurysms; distal artery aneurysms; non-saccular aneurysms posterior circulation aneurysms and complication rates similar to traditional techniques. In the short interval since the Pipeline Embolization Device was first introduced, FDS has been firmly entrenched as a powerful tool in the endovascular armamentarium. As new FDS are developed, established FDS are refined, and delivery systems are improved the uses for FDS will only expand further. Researchers continue to work to optimize the mechanical characteristics of the FDS themselves, aiming to optimize deploy ability and efficacy. With expanded use for small to medium aneurysms and posterior circulation aneurysms, FDS technology is firmly entrenched as a powerful tool to treat challenging aneurysms, both primarily and as an adjunct to coil embolization. With the aforementioned advances, the ease of FDS deployment will improve and complication rates will be further minimized. This will only further establish FDS deployment as a key strategy in the treatment of cerebral aneurysms.