• Title/Summary/Keyword: Mechanical Tests

Search Result 4,974, Processing Time 0.039 seconds

Mechanical and Durability Characteristics of Latex-Modified Concrete Using Ultra Rapid Hardening Cement (초속경 시멘트를 이용한 라텍스 개질 콘크리트의 역학성능과 내구성능)

  • Park, Sang-Hyun;Jung, Si-young;Kim, Hyun-yu;Choi, Kyoung-Kyu
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.5
    • /
    • pp.153-160
    • /
    • 2019
  • The purpose of this study was to investigate the mechanical and durability characteristics of latex-modified concrete using ultra rapid hardening cement : four types of mechanical tests including compressive strength, modulus of elasticity, flexural strength and bond strength were performed; and seven types of durability tests including resistance of concrete to chloride ion penetration, freeze-thaw resistance, scaling resistance, coefficient of thermal expansion, cracking tendency, abrasion resistance and drying shrinkage were performed. Required material performance of each test was determined in accordance with the Korea specification for repair of concrete and pavement repairing materials. The test results satisfied the required material performances, and presented a good mechanical and durability characteristics. In particularly, the materials showed early development of compressive strength, flexural strength and bond strength at 3 and 4 hours after curing. SEM photos were also taken to investigate the micro structures of the materials after chloride ion penetration test.

A Study of the Vibration of an Axial Flow Pump through FSI Analysis Method (유체-구조 연성해석을 통한 축류펌프의 진동 연구)

  • Lee, Bo-Ram;Yun, Tae-Jong;Oh, Won-Bin;Lee, Chung-Woo;Kim, Hak Hyoung;Jeong, Yeong Jae;Kim, Ill-Soo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.3
    • /
    • pp.107-112
    • /
    • 2021
  • Pressure, which is a dynamic characteristic of a floodgate, is predicted using an FSI analysis method. A fluid analysis model and a hydrology analysis model were used as analysis models. As a result of the analysis, we found that a warped model has smaller acceleration than a square model. Additionally, this numerical analysis technique was applied to the actual hydrology, and the analysis results were compared with the results of the vibration tests. As a result, we confirmed that there is a small difference between the results of the vibration tests and the results of the FSI analysis. Through this analysis, the applicability and reliability of the FSI analysis method were verified. We concluded that the pressure of a floodgate can be measured through an FSI analysis method.

The Study for maintence of heavy duty Agitator (대형교반기의 유지 관리에 관한 연구)

  • Kang, M.H.;Yang, S.B.;Kim, K.P.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.425-430
    • /
    • 2005
  • This Study presents to be Agitator maintenance for Water and Wastewater treatment Plant. This procedures offers methods of Design Creteria and performance tests on mixing equipment. These tests may be conducted to determine process performance, mechanical reliability. or suitability of equipment for the intended use. The reasons for conducting performance tests can be varied, but the methods presented should be generally applicable to most situations.

  • PDF

The Influence of Forest Fire on the Polymer Insulator for Transmission Lines (송전용 폴리머 애자에 대한 산불 영향 평가)

  • Choi, In-Hyuk;Lee, Dong-Il;Lee, Chul-Ho;Kang, Byoung-Kyu;Lee, Won-Kyo;Park, Jun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.9
    • /
    • pp.787-792
    • /
    • 2007
  • To understand the effects of forest fires on polymer insulators for transmission lines, the forest fire simulation tests were performed with polymer and porcelain insulators at Gochang testing center. These tests consisted of energizing 90 kV at line-to-ground voltage of 154 kV lines and open flame rising up to $600-630^{\circ}C$ as being measured at insulator surface. Mechanical and electrical characteristics such as specific mechanical load, leakage current, low frequency dry flashover voltage and impulse flashover voltage were analyzed for the polymer insulators before, during and after simulation tests compared with porcelain insulators. At the end of fire simulation tests, there was no detrimental deterioration of any insulators. All insulators passed the criteria of KEPCO specification. This study showed that forest fire simulation had no impact on polymer insulators.

Estimations of the Adhesion Strength of Galvannealed Coatings on Coated Sheet Using Single Lap-Shear Test (단일겹치기이음시험을 이용한 합금화용융아연코팅강판의 코팅층 접합강도 평가)

  • Lee, Jung-Min;Lee, Chan-Joo;Ko, Dae-Cheol;Lee, Seon-Bong;Kim, Byung-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.6
    • /
    • pp.560-567
    • /
    • 2009
  • This paper was designed to estimate the adhesion strength of galvannealed coatings on steel sheets. The adhesion strength were evaluated using single lap - shear tests where the lap joint was bonded by structural adhesive. Tests were performed for overlap length of 5mm, 10mm and 15 mm and three directions (0, 45, 90) of steel sheets used as the adherend of the overlap joint. After the tests, FE simulations of the single lap-shear test were also carried out to observe the stress distribution in the interface between the adhesive and the coated sheet. The results showed that the joint failure loads obtained from the tensile tests of bonded single lap-joints were the same, regardless of overlap lengths and directions of steel sheets. Also, the failure of galvannealed coatings greatly depended on shear stress distribution in the interface and the value was about 30MPa.

Constitutive Model of Tendon Responses to Multiple Cyclic Demands(I) -Experimental Analysis-

  • Chun, Keyoung-Jin;Robert P. Hubbard
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.1002-1012
    • /
    • 2001
  • The work reported here is an extensive study of tendon response to multiple cyclic tests including 3% constant peak strain level test (A-type test), 3% constant peak strain level test with two rest periods (B-type test), and 3∼4% different peak strain level test (C-type test). A sufficient number of specimens were tested at each type of the test to statistically evaluate many changes in response during testing and differences in response between each type of the test. In cyclic tests, there were decreses (relaxations) in the peak stresses and hysteresis, increases in the slack strains, and during lower peak strain level (3%) cyclic block after higher peak strain level (4%) cyclic block in the C-type tests. Considering the results of this study and those of the other study of multiple cyclic tests with rest periods by Hubbard and Chun, 1985, recovery phenomena during the rest periods occurred predominantly at the beginning of the rest periods. Consistently in both studies, the effects of rest periods were small and transient compared to the effects of the cyclic extensions. The recovery with cycles at lower peak strain level (3%) after higher peak strain level (4%) in the C-type test has not been previously documented. This recovery seems to be a natural phenomena in tissue behavior so that collagenous structures recover during periods of decreased demand.

  • PDF

Development of Local Failure Criteria for Well Thinning Defect by Simulated Specimen Tests (모사시편 시험을 통한 감육결함 국부손상기준 개발)

  • Kim, Jin-Weon;Kim, Do-Hyung;Park, Chi-Yong;Lee, Sung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.3 s.258
    • /
    • pp.304-312
    • /
    • 2007
  • The objective of this study is to develop a local failure criterion for a wall thinning defect of piping components. For this purpose, a series of tensile tests was performed using several types of simulated specimens with different stress states, including smooth round bar, notched round bar (five different notch radii), and grooved plate (three different groove radii). In addition, finite element (FE) simulations were performed on the simulated specimen tests and the results were compared with the test results. From the comparisons, the equivalent stress and strain corresponding to maximum load and final failure of notched specimens were proposed as failure criteria under tensile load. The criteria were verified by employing them to the estimation of failure of grooved plate specimens that simulate the wall thinning defect. It showed that the proposed criteria accurately estimate the maximum load and final failure of grooved plate specimen tests.

Structural Safety Evaluation of An Autoclave Cured Train Carbody with Length of 23m (오토클레이브 성형된 길이 23m 복합재 철도차량 차체의 구조적 특성평가)

  • Kim, Jung-Seok;Lee, Sang-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.11 s.242
    • /
    • pp.1551-1559
    • /
    • 2005
  • This paper explains manufacturing process and experimental studies on a composite carbody of Korean tilting train. The composite carbody with length of 23m was manufactured as a sandwich structure composed of a 40mm-thick aluminium honeycomb core and 5mm-thick woven fabric carbon/epoxy face. In order to evaluate structural behavior and safety of the composite carbody, the static load tests such as vertical load, end compressive load, torsional load and 3-point support load tests have been conducted. These tests were performed under Japanese Industrial Standard (JIS) 17105 standard. From the tests, maximum deflection was 12.3mm and equivalent bending stiffness of the carbody was 0.81$\times$10$^{14}$ kgf$\cdot$mm$^{2}$ Maximum stress of the composite body was lower than 12.2$\%$ of strength of the carbon/epoxy. Therefore, the composite body satisfied the Japanese Industrial Standard.

Investigation of Cutting Characteristics in the Sharp Comer for the Case of Cutting of Inconel 718 Super-alloy Sheet Using High-power CW Nd:YAG Laser (고출력 CW Nd:YAG 레이저를 이용한 인코넬 718 판재 절단시 모서리부 절단 특성 분석)

  • Ahn, Dong-Gyu;Byun, Kyung-Won
    • Journal of Welding and Joining
    • /
    • v.26 no.5
    • /
    • pp.90-96
    • /
    • 2008
  • The objective of this paper is to investigate the effects of the laser power, the material thickness, comer angles, and the loop size on the formation of the comer in the cutting of Inconel 718 super-alloy sheet using high-power CW Nd: YAG laser. In order to investigate the influence of comer angles and loop sizes on the melted area and the formation of comer in the sharp comer, angular cutting tests and loop cutting tests were carried out. The results of the angular cutting tests were shown that the melted area is minimized and the melting mode is changed from nose melting in the thickness direction to the secondary melting induced by the attached dross when the comer angle is $90^{\circ}$. Through the results of loop cutting tests, the variation of the melted area and the comer shape in the sharp comer according to the loop size were examined. In addition, it was shown that a proper loop size is approximately 3 mm. The results of above experiments will be reflected on the knowledge base to generate optimal cutting path of the laser.

Effect of Ni and Mo Addition on Fatique Property in 12Cr Steel (12Cr강의 피로특성에 미치는 Ni+Mo 첨가의 영향)

  • Lee, Jin-Kyung;Bae, Dong-Su
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.4_2
    • /
    • pp.435-441
    • /
    • 2021
  • This research was performed to study the effect of the Ni + Mo addition on the fatigue properties in 12Cr steel. After heat treatment of 12Cr steel and 12Cr-Ni-Mo steel, tensile tests, impact tests, hardness tests, and rotary bending fatigue tests were performed, respectively. The fatigue fracture surface was observed and analyzed using SEM and EDS. The fatigue limit of 12Cr steel was 554 MPa, which was 49 MPa higher than 505 MPa of 12Cr-Ni-Mo steel. Striations, which are the shape of the typical fatigue fracture surface, were observed at the fracture surface near the starting point of fatigue fracture in the 12Cr steel and 12Cr-Ni-Mo steel. However, unlike the case of 12Cr steel, 12Cr-Ni-Mo steel also had a mixed fracture surface with the fatigue and the ductile fracture surface. When brittle non-metallic inclusions exist near the starting point of fatigue failure, the crack propagation was further promoted and the fatigue life was drastically reduced.