• 제목/요약/키워드: Mechanical Integrity

검색결과 790건 처리시간 0.029초

Thermal aging of Gr. 91 steel in supercritical thermal plant and its effect on structural integrity at elevated temperature

  • Min-Gu Won;Si-Hwa Jeong;Nam-Su Huh;Woo-Gon Kim;Hyeong-Yeon Lee
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.1-8
    • /
    • 2024
  • In this study, the influence of thermal aging on structural integrity is investigated for Gr. 91 steel. A commercial grade Gr. 91 steel is used for the virgin material, and service-exposed Gr. 91 steel is sampled from a steam pipe of a super critical plant. Time versus creep strain curves are obtained through creep tests with various stress levels at 600 ℃ for the virgin and service-exposed Gr. 91 steels, respectively. Based on the creep test results, the improved Omega model is characterized for describing the total creep strain curve for both Gr. 91 steels. The proposed parameters for creep deformation model are used for predicting the steady-state creep strain rate, creep rupture curve, and stress relaxation. Creep-fatigue damage is evaluated for the intermediate heat exchanger (IHX) in a large-scale sodium test facility of STELLA-2 by using creep deformation model with proposed creep parameters and creep rupture curve for both Gr. 91 steels. Based on the comparison results of creep fatigue damage for the virgin and service-exposed Gr. 91 steels, the thermal aging effect has been shown to be significant.

KASS 가용성 성능 평가를 위한 MATLAB GUI 기반 소프트웨어 설계 (Development of MATLAB GUI Based Software for Analysis of KASS Availability Performance)

  • 최봉관;한덕화;김동욱;김정범;기창돈
    • 한국항행학회논문지
    • /
    • 제22권5호
    • /
    • pp.384-390
    • /
    • 2018
  • 본 논문에서는 KASS (korea augmentation satellite system) 의 가용성 성능 평가를 위한 MATLAB GUI (graphical user interface)기반의 소프트웨어에 대해 소개한다. 본 소프트웨어는 MV (minimum variance) estimator 와 Kriging 알고리즘을 이용해 한반도 지역의 지상 사용자 및 항공기 사용자에 대해 UDRE (user differential range error) 와 GIVE (grid ionospheric vertical error) 와 같은 무결성 정보를 생성한다. 또한 본 소프트웨어는 생성한 정보를 이용하여 사용자의 각 위치에 대해 정확도, 보호 수준, 가용성 지도를 제공한다. 특히 항공기 경로에 대해 경로에 따른 보호 수준 값을 계산하는 기능을 수행한다. 항공기 사용자에 대한 보호 수준 값 계산 결과는 EGNOS (european geostationary navigation overlay service) 의 시뮬레이션 툴인 SBASimulator#2의 결과와 비교하여 검증하였다. 그 결과 본 소프트웨어가 생성한 보호 수준의 값의 오차가 약 2% 정도로 정확하게 나온 것을 확인하였다.

영향계수를 이용한 원통용기 축방향 표면결함의 응력확대계수의 계산 (Stress Intensity factor Calculation for the Axial Semi-Elliptical Surface Flaws on the Thin-Wall Cylinder Using Influence Coefficients)

  • 장창희;문호림;정일석;김태룡
    • 대한기계학회논문집A
    • /
    • 제26권11호
    • /
    • pp.2390-2398
    • /
    • 2002
  • For integrity analysis of nuclear reactor pressure vessel, including the Pressurized thermal shock analysis, the fast and accurate calculation of the stress intensity factor at the crack tip is needed. For this, a simple approximation scheme is developed and the resulting stress intensity factors for axial semi-elliptical cracks in cylindrical vessel under various loading conditions are compared with those of the finite element method and other approximation methods, such as Raju-Newman's equation and ASME Sec. Xl approach. For these, three-dimensional finite-element analyses are performed to obtain the stress intensity factors for various surface cracks with t/R = 0.1. The approximation methods, incorporated in VINTIN (Vessel INTegrity analysis-INner flaws), utilizes the influence coefficients to calculate the stress intensity factor at the crack tip. This method has been compared with other solution methods including 3-D finite clement analysis for internal pressure, cooldown, and pressurized thermal shock loading conditions. The approximation solutions are within $\pm$2.5% of the those of FEA using symmetric model of one-forth of a vessel under pressure loading, and 1-3% higher under pressurized thermal shock condition. The analysis results confirm that the VINTIN method provides sufficiently accurate stress intensity factor values for axial semi-elliptical flaws on the surface of the reactor pressure vessel.

소듐 시험루프 내 소듐대 공기 열교환기의 고온 설계 (High-Temperature Design of Sodium-to-Air Heat Exchanger in Sodium Test Loop)

  • 이형연;어재혁;이용범
    • 대한기계학회논문집A
    • /
    • 제37권5호
    • /
    • pp.665-671
    • /
    • 2013
  • 제 4 세대 소듐냉각 고속로에는 중간열교환기(IHX), 붕괴열제거 열교환기(DHX), 공기 열교환기(AHX), 핀형 소듐-공기 열교환기(FHX) 및 증기발생기(SG)를 포함한 다양한 열교환기들이 설치된다. 본 연구에서는 STELLA-1 시험루프에 설치된 소듐-공기 열교환기인 AHX 와 SELFA 시험루프에 설치될 핀형(finned) 소듐-공기 열교환기인 FHX 등 2 기의 열교환기 설계에 대해 3D 상세 유한요소해석을 수행하고, 동 결과에 기초하여 고온설계 기술기준을 따라 크리프-피로 손상평가를 수행하였다. 손상 평가결과 AHX와 FHX는 의도하는 크리프 피로 손상 하중 하에서 구조 건전성을 유지하는 것으로 확인되었다.

불순물 활성화 열처리가 MOS 캐패시터의 게이트 전극과 산화막의 특성에 미치는 효과 (Impacts of Dopant Activation Anneal on Characteristics of Gate Electrode and Thin Gate Oxide of MOS Capacitor)

  • 조원주;김응수
    • 전자공학회논문지D
    • /
    • 제35D권10호
    • /
    • pp.83-90
    • /
    • 1998
  • MOS 캐패시터의 게이트 전극을 비정질 상태의 실리콘으로 형성하여 GOI(Gate Oxide Integrity)특성에 미치는 불순물 활성화 열처리의 효과를 조사하였다. LPCVD(Low Pressure Chemical Vapor Deposition) 방법으로 증착한 비정질 실리콘 게이트 전극은 활성화 열처리에 의하여 다결정 실리콘 상태로 구조가 변화하며, 불순물 원자의 활성화가 충분히 이루어졌다. 또한, 비정질 상태의 게이트 전극은 커다란 압축 응력(compressive stress)을 가지지만, 활성화 열처리 온도가 700℃에서 900℃로 증가함에 따라서 응력이 완화되었고 게이트 전극의 저항도 감소하는 특성을 보였다. 또한 얇은 게이트 산화막의 신뢰성 및 산화막의 계면특성은 활성화 열처리 온도에 크게 의존하고 있었다. 900℃에서 활성화 열처리를 한 경우가 700℃에서 열처리한 경우보다 산화막내에서의 전하 포획 특성이 개선되었으며, 산화막의 신뢰성이 향상되었다. 특히, TDDB 방법으로 예측한 게이트 산화막의 수명은 700℃의 열처리에서는 3×10/sup 10/초였지만, 900℃에서의 열처리에서는 2×10/sup 12/초로 현저하게 개선되었다. 그리고, 산화막 계면에서의 계면 전하 밀도는 게이트의 응력 완화에 따라서 개선되었다.

  • PDF

천연가스 공급배관의 사용적합성 통합프로그램 (Integrated Fitness-for-service Program for Natural Gas Transmission Pipeline)

  • 김우식;김영표;김철만;백종현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.269-274
    • /
    • 2008
  • For fitness-for-service analyses of underground natural gas pipelines, engineering assessment methods against possible defects need to be developed. The assessment methods for high pressure pipeline of KOGAS, was developed using the full size pipe burst tests and the finite element analysis. It included the defect assessment methods for a single and multi-corrosion, corrosion in girth welding part, corrosion in seam welding part, the mechanical damage defects as dent and gouge, crack and large plastic deformation of API 5L X65 pipe. In addition, we developed method to assess pipeline integrity by internal and external load to buried pipeline. Evaluation results were compared with other methods currently being applied to the gas pipeline. The program of Windows environment is made for easily using assessment methods. It provides a consistent user interface, so non-professional technician can easily and friendly use the FFS program from company intranet. Several evaluation programs is easily installed using one installer. Each program constitutes a common input interface and the output configuration program, and evaluation result store and can be recalled at any time. The FFS program based on independent evaluation method is used to evaluate the integrity and safety of KOGAS pipeline, and greatly contribute to safe and efficient operation of pipeline. This paper presents experimental, analytical and numerical investigations to develop the FFS methods for KOGAS pipeline, used as high pressure natural gas transmission pipeline within KOREA. Also, it includes the description of the integrated program for FFS methods.

  • PDF

SUS316L 로 제작된 실험실 수준 인쇄기판형 열교환기 시제품의 고온구조건전성 평가 (Evaluation of High-Temperature Structural Integrity Using Lab-Scale PCHE Prototype)

  • 송기남;홍성덕
    • 대한기계학회논문집A
    • /
    • 제37권9호
    • /
    • pp.1189-1194
    • /
    • 2013
  • 초고온가스로의 중간열교환기는 원자로에서 생산된 $950^{\circ}C$ 정도의 초고온 열을 수소생산 공장으로 전달하는 핵심 기기이다. 한국원자력연구원에서는 중간열교환기의 후보 형태로 고려되고 있는 인쇄기판형 열교환기의 실험실 수준 시제품을 제작하였다. 본 연구는 초고온헬륨루프 시험조건하에서 SUS316L 로 제작된 실험실 수준 인쇄기판형 열교환기 시제품의 고온구조건전성을 미리 평가하기 위한 작업의 일환으로 인쇄기판형 열교환기 실험실 수준 시제품에 대한 고온 구조해석 모델링, 거시적 열 해석 및 구조 해석을 수행하고 그 결과들을 정리한 것이다.

가스터빈 패키지 내충격 성능평가에 관한 연구 (Evaluation of the Shock Resistance of a Gas Turbine Package)

  • 김재부;박윤기;박민석;이종환;안성찬
    • 대한기계학회논문집A
    • /
    • 제41권10호
    • /
    • pp.1005-1009
    • /
    • 2017
  • 본 연구에서는 수중폭발에 의한 가스터빈 패키지에 작용하는 충격하중을 평가하고, 충격하중에 대한 가스터빈 패키지의 내충격 안전성을 검토하였다. 이를 위해 먼저 BV043에 따른 시간이력 충격하중을 산출하고, 산출된 충격하중을 바탕으로 이상화된 WEM(Whole Engine Model, 전체시스템)에 대한 시간영역에서의 과도응답해석을 수행하였다. 이를 통해 가스터빈 패키지의 주요구성품에 전달되는 하중을 평가하였으며, 평가된 전달하중을 바탕으로 주요구성품의 상세모델에 대한 내충격 안전성 검토를 수행하였다. 검토결과 가스터빈 패키지는 기준응력 대비 최소 1.0 이상의 안전율을 가지는 것을 확인하였다. 그리고 실물테스트를 통해 가스터빈 패키지 엔진제어시스템(EMS : Engine Management System) 구조 및 제어기능의 내충격 건전성을 검증하였다.

부분안전계수를 이용한 감육배관의 신뢰도 기반 건전성 평가 (Reliability-Based Structural Integrity Assessment of Wall-Thinned Pipes Using Partial Safety Factor)

  • 이재빈;허남수;박치용
    • 한국생산제조학회지
    • /
    • 제22권3_1spc호
    • /
    • pp.518-524
    • /
    • 2013
  • Recently, probabilistic assessments of nuclear power plant components have generated interest in the nuclear industries, either for the efficient inspection and maintenance of older nuclear plants or for improving the safety and cost-effective design of newly constructed nuclear plants. In the present paper, the partial safety factor (PSF) of wall-thinned nuclear piping is evaluated based on a reliability index method, from which the effect of each statistical variable (assessment parameter) on a certain target probability is evaluated. In order to calculate the PSF of a wall-thinned pipe, a limit state function based on the load and resistance factor design (LRFD) concept is first constructed. As for the reliability assessment method, both the advanced first-order second moment (AFOSM) method and second-order reliability method (SORM) are employed to determine the PSF of each probabilistic variable. The present results can be used for developing maintenance strategies considering the priorities of input variables for structural integrity assessments of wall-thinned piping, and this PSF concept can also be applied to the optimal design of the components of newly constructed plants considering the target reliability levels.

소듐냉각고속로 붕괴열교환기의 고온 설계 및 건전성 평가 (High-Temperature Design and Integrity Evaluation of Sodium-Cooled Fast Reactor Decay Heat Exchanger)

  • 이형연;어재혁
    • 대한기계학회논문집A
    • /
    • 제37권10호
    • /
    • pp.1251-1259
    • /
    • 2013
  • 본 연구에서는 소듐냉각 고속로 붕괴열교환기(DHX)의 고온 설계 및 크리프-피로 손상 평가를 수행하였다. 제 4 세대 소듐냉각 고속로의 능동 및 피동 잔열제거계통에 설치되는 DHX와 한국원자력연구원의 STELLA-1 시험루프에 설치된 DHX에 대해 상세설계 및 3D 유한요소해석을 수행하고, 동 결과에 기초하여 고온설계 기술기준인 ASME Section III Subsection NH와 RCC-MR 코드를 따라 크리프-피로 손상평가를 수행하였다. 크리프-피로 손상평가 결과에 기초하여 두 설계기준에 대해 비교 분석하고, 설계 기술기준의 보수성 이슈에 대해 토의하였다.