• Title/Summary/Keyword: Mechanical Filter

Search Result 905, Processing Time 0.029 seconds

Study on Filter Efficiency and Lifetime Enhancement by using Internal Structures (내부구조물을 이용한 필터의 효율 및 수명 상승에 대한 연구)

  • Kim, Ji-Hun;Yoon, Sangwoo;Kwon, Sung-Ho;Sung, Su-Hwan;Bae, Mun-Oh;Kim, Joohan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.5
    • /
    • pp.149-154
    • /
    • 2018
  • To improve the efficiency and lifetime of filters, we analyze the element distribution at the entrance and exit by using the flow inside a filter, confirming that the internal structure affects the filter efficiency. The flow in the pipe is predicted through computer simulations, and the filtration efficiency of each element is compared through experiments. The efficiency and lifetime of the filter are indirectly improved through the element distribution at the filter outlet according to the internal structure. Because pressure loss from the structure inevitably occurs, the efficiency and lifetime of filters against pressure loss must be considered.

Synchronous Interfusion of the Compensatory Filters Based on Multi-rate Sensors for the Control of the Autonomous Vehicle (자율주행 차량 제어를 위한 다중 주기 센서 기반의 상보 필터 동기 융합)

  • Bak, Jeong-Hyeon;Lee, Kwanghee;Lee, Chul-Hee
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.3
    • /
    • pp.220-227
    • /
    • 2014
  • This paper presents about multi-rate sensors' synchronization and filter fusion via a sigmoid function of the Kalman filter. To synchronize multi-rate sensors, the estimation states of the Kalman filter is modified. A specific matrix that makes the filter choose sensor values only updated is multiplied to measurement matrix. For the filter that has weak points on some criteria, filter fusion is suggested by using sigmoid function. Modified kalman filter is tested with practical case. A sigmoid function was designed for the test and the performance of the modified function is estimated with respect to conventional Kalman filter. Unscented Kalman filter is used to the base filter of the suggested filter because of its stability.

Analysis of Flow Characteristics of Multiple Filter System (다중 필터 시스템의 유동특성 해석)

  • In-Soo Son;Mi-Young Seo;Jun-Ho Kim;Jin-Soek Yu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.615-621
    • /
    • 2023
  • In this study, flow analysis of single, double, and triple filter systems of cylindrical structures was performed to analyze the flow characteristics of each filter. As a result of the flow analysis of the filter system, the number of filters and the pressure drop rate tend to be proportional to each other. It was found that the area passing through the inside of the filter had almost the same pressure. The maximum pressure drop rate of the triple filter system was about 14.9% for the forward-flow and about 12.4% for the reverse-flow. It was determined that the performance of the filter was stable within 20% of the allowable pressure drop rate of the filter system, which is the standard presented to the Korea Water Technology Certification Institute(KWTCI). In the future, a study on the decompression characteristics of the filter system according to the effect of the arrangement interval and filter density of the triple filter will be conducted.

Maneuvering Target Tracking Using Multiresolutional Interacting Multiple Model Filter

  • Yu, C,H.;Choi, J.W.;Song, T.L.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2340-2344
    • /
    • 2003
  • This paper considers a tracking filter algorithm which can track a maneuvering target. Multiresolutional Interacting Multiple Model (MRIMM) algorithm is proposed to reduce computational burden. In this paper multiresolutional state space model equation and multiresolutional measurement equation are derived by using wavelet transform. This paper shows the outline of MRIMM algorithm. Simulation results show that MRIMM algorithm maintains a good tracking performance and reduces computational burden.

  • PDF

Adaptive Suppression of Mechanical Resonance in High-Density Disk Drives (고밀도 디스크 드라이브의 적응형 공진 보상 알고리즘)

  • 강창익;김창환
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.9
    • /
    • pp.679-691
    • /
    • 2003
  • The band-width of disk drive servo system is rapidly increasing for the robustness to external disturbance as the track density is increasing. The increase of the band-width may cause mechanical resonance of an actuator. In disk drive servo system, a notch filter is usually used to suppress the mechanical resonance of the actuator. However, the resonance frequency differs from drive to drive because of manufacturing tolerance and varies with temperature even within a single drive. The variation of resonance frequency degrades the suppression performance of the notch filter. In this paper, we present an adaptive digital notch filter that identifies the resonance frequency of the disk drive servo actutaor precisely and adjusts automatically its center frequency. For this, we design an adaptive FIR digital filter for the estimation of the resonance frequency. The estimation filter identifies the resonance frequency adaptively using the output signal generated from the servo system, which is excited with an excitation signal including all the expected resonance frequency components. We prove mathematically the convergence of the resonance frequency estimation filter. Furthermore, in order to demonstrate the practical use of our work, we present some experimental results using a commercially available disk drive.

Effect of the Internal Shape of eDNA Filter Case made by the PBF method Metal 3D Printer on Water Sampling Performance (PBF 방식 금속 3D프린터로 제작된 환경DNA 필터 케이스의 내부 형상이 포집 성능에 미치는 영향)

  • Lee, Seung-Min;Park, Se-Hyun;Kwak, Ihn-Sil;Kim, Hyoung-Ho;Kwak, Tae-Soo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.8
    • /
    • pp.74-79
    • /
    • 2021
  • This study focuses on designing a filter case using a water pump for application in eDNA filtering systems. Filter cases, channel type and net type were designed based on the flow field and made using a 3D printer for metal. Flow analysis was conducted for each filter case, and the results were consistent with the pressure experiment results. Furthermore, the water sampling performance test showed that the channel-type filter case exhibited a high flow rate and low pressure through the filter. The eDNA extraction experiment showed that the channel type exhibited improved capture ability compared to the net type.

Measurement of Short Reverberation Times at Low Frequencies Using Wavelet Filter Bank

  • Lee, Sang-Kwon
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.511-520
    • /
    • 2003
  • In room acoustics, reverberation time is an important acoustic parameter. However it is often difficult to measure short reverberation times at low frequencies with a traditional band pass filter bank if the product of filter bandwidth (B) and reverberation time (T) is small. It it well known that the minimum permissible product of bandwidth and reverberation time of the traditional band pass filter is at least 16. This strict requirement makes it difficult to measure short reverberation times of an acoustic room at low frequencies exactly. In order to reduce this strict requirement, in the previous paper, the wavelet filter bank was developed and the minimum permissible product of bandwidth and reverberation time was replaced with 4. In the present paper it is demonstrated how the short reverberation times of an practical room at low frequencies are successfully measured by using the wavelet filter bank and the results are compared with the traditional method using a band past filer bank.

Fabrication of Low Density Sintered Stainless Steel Filter

  • Seok, Se-Hoon;Park, Dong-Kyu;Jung, Kwang-Chul
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.611-612
    • /
    • 2006
  • In a manufacturing technique of the sintered filter, pressureless sintering method has good permeability, it is not need the binder and lubricant used on compacting process, so it has little contamination and it is easy to control the pore size and shape but the mechanical strength is low relatively and it is difficult that parts of complicate form are manufactured. In the case of manufacturing the filter by press and sintering method, in order to be satisfactory characteristic of un-pressed filter, in this study sintered metal filter fabricated by using 30-40mesh stainless steel 316L powder and additive agents. Porosity and structure of pores, permeability and mechanical strength of the sintered filter were investigated with the variation sintering conditions. Porosity was nearly constant about $60{\sim}70%$, density, permeability and mechanical strength were changed markedly with quantity of additive materials and sintering conditions.

  • PDF

Performance of Respirator Filters Using Quality Factor (qF) (양질계수(Quality Factor)를 이용한 방진마스크 필터의 성능평가)

  • Han, Don-Hee;Jeong, Yoon-Sok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.170-178
    • /
    • 2000
  • Most of manufacturers try to produce the most efficient filter for respirators with the lowest breathing resistance. Filter performance depends on low penetration, i.e., high efficiency (%), and low pressure drop ($mmH_2O$). This study was performed to evaluate performance of respirator filters by quality factor ($q_F$) and suggest the direction for improvement of respirator filters of good quality in Korea. Two mechanical filters, S and K made in Korea, three filtering facepieces, S made in China, C made in Korea and M made in USA, which were widely used in the workplace, were selected and tested efficiency and pressure drop in accordance with flow rate, using with Automated Filter Tester Model 8110 (TSI, USA). The best quality factor within the same respirator filter categories was $0.0672cm^{-1}\;H_2O$ for mechanical filter S, $0.0698cm^{-1}\;H_2O$ for filtering facepiece M at flow rate of 32Lpm. Mechanical filter S would be the best suitable during heavy work since qulity factors decrease less sharply than any others as increased flow rates. It was necessary for mechanical filter S to lower pressure drop without increasing efficiency, but mechanical filter K should be increased efficiency and decreased pressure drop. While filtering facepiece M had the best quality performance of three ones, Sand C should get much higher efficiency and lower pressure for better performance.

  • PDF

Effect of Particle Loading on the Collection Performance of an Electret Cabin Air Filter for Submicron Particles (입자 퇴적이 승용차용 정전 필터의 미세 입자 포집 특성에 미치는 영향)

  • Ji, Jun-Ho;Gang, Seok-Hun;Hwang, Jeong-Ho;Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1102-1114
    • /
    • 2002
  • An electret filter is composed of permanently charged electret fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using poly-disperse particles when submicron particles were loaded. Long-term experiments were conducted by applying two different charging states, which were spray electrification and charge equilibrium by bipolar ionization. In order to investigate the effect of particle loading in filter media, NaCl particles were generated from 0.1% and 1% solutions by an atomizer. Liquid DOS particles were used to evaluate the effect of liquid particles on the collection efficiency of an electret filter. The results show significant effect of charge amount and size distribution of loading particles on the collection performance of a filter media in submicron region. Smaller particles loaded in electret fibers cause a more rapid degradation in collection efficiency and have lower minimum efficiency with time. The pressure drop of a filter media do rarely increase when the collection efficiency decreases to the minimum value. For the larger particles charged by spray electrification, which have charge amounts more than that of Boltzmann equilibrium charge distribution, the pressure drop of a filter media slowly increases in comparison with that of equilibrium charged particles. For DOS particles it is shown that the charging level of an electret filter severely decreases and the collection efficiency is below 10% in some particle size range.